948 resultados para Perceptual closure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations. OBJECTIVES: To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles, PAC and PACG. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library), MEDLINE, EMBASE and LILACS (Latin American and Caribbean Literature on Health Sciences). The databases were last searched on 11 February 2008. SELECTION CRITERIA: Only randomised controlled trials (RCTs) were eligible for inclusion in this review. Patients with narrow angles, PAC or PACG were eligible. Studies that included only patients with acute presentations, using laser peripheral iridoplasty to break acute crisis were excluded. DATA COLLECTION AND ANALYSIS: No analysis was carried out due to lack of trials. MAIN RESULTS: There were no RCTs assessing laser peripheral iridoplasty in the non-acute setting of angle-closure. AUTHORS' CONCLUSIONS: There is currently no strong evidence for laser peripheral iridoplasty's use in treating angle-closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care.

METHODS/DESIGN: EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate.

TRIAL REGISTRATION: ISRCTN44464607.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Cases of angle-closure glaucoma in patients with familial exudative vitreoretinopathy have been reported secondary to neovascularization of the anterior segment. Cases secondary to nonneovascular mechanisms have not been previously reported. Methods: Two cases are presented of angle-closure glaucoma as a result of a nonneovascular mechanism. Results: Neovascularization was found to be a very unlikely explanation for the angle closure in these two cases. Conclusion: There may be an association between familial exudative vitreoretinopathy and angle-closure glaucoma as a direct result of a retrolental process or more likely a relative lens-iris pupillary block with a large lens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In specific solid-state materials, under the right conditions, collections of magnetic dipoles are known to spontaneously form into a variety of rather complex geometrical patterns, exemplified by vortex and skyrmion structures. While theoretically, similar patterns should be expected to form from electrical dipoles, they have not been clearly observed to date: the need for continued experimental exploration is therefore clear. In this Letter we report the discovery of a rather complex domain arrangement that has spontaneously formed along the edges of a thin single crystal ferroelectric sheet, due to surface-related depolarizing fields. Polarization patterns are such that nanoscale “flux-closure” loops are nested within a larger mesoscale flux closure object. Despite the orders of magnitude differences in size, the geometric forms of the dual-scale flux closure entities are rather similar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambisonics is a scalable spatial audio technique that attempts to present a sound scene to listeners over as large an area as possi- ble. A localisation experiment was carried out to investigate the performance of a first and third order system at three listening positions - one in the centre and two off-centre. The test used a reverse target-pointer adjustment method to determine the error, both signed and absolute, for each combination of listening posi- tion and system. The signed error was used to indicate the direc- tion and magnitude of the shifts in panning angle introduced for the off-centre listening positions. The absolute error was used as a measure of the performance of the listening position and systems combinations for a comparison of their overall performance. A comparison was made between the degree of image shifting be- tween the two systems and the robustness of their off-centre per- formance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In noise repetition-detection tasks, listeners have to distinguish trials of continuously running noise from trials in which noise tokens are repeated in a cyclic manner. Recently, it has been shown that using the exact same noise token across several trials (“reference noise”) facilitates the detection of repetitions for this token [Agus et al. (2010). Neuron 66, 610–618]. This was attributed to perceptual learning. Here, the nature of the learning was investigated. In experiment 1, reference noise tokens were embedded in trials with or without cyclic presentation. Naïve listeners reported repetitions in both cases, thus responding to the reference noise even in the absence of an actual repetition. Experiment 2, with the same listeners, showed a similar pattern of results even after the design of the experiment was made explicit, ruling out a misunderstanding of the task. Finally, in experiment 3, listeners reported repetitions in trials containing the reference noise, even before ever hearing it presented cyclically. The results show that listeners were able to learn and recognize noise tokens in the absence of an immediate repetition. Moreover, the learning mandatorily interfered with listeners' ability to detect repetitions. It is concluded that salient perceptual changes accompany the learning of noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach for extracting stress intensity factors (SIFs) by the element-free Galerkin (EFG) class of methods through a modified crack closure integral (MCCI) scheme is proposed. Its primary feature is that it allows accurate calculation of mode I and mode II SIFs with a relatively simple and straightforward analysis even when a coarser nodal density is employed. The details of the adoption of the MCCI technique in the EFG method are described. Its performance is demonstrated through a number of case studies including mixed-mode and thermal problems in linear elastic fracture mechanics (LEFM). The results are compared with published theoretical solutions and those based on the displacement method, stress method, crack closure integral in conjunction with local smoothing (CCI–LS) technique, as well as the M-integral method. Its advantages are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using piezoresponse force microscopy, we have observed the progressive development of ferroelectric flux-closure domain structures and Landau−Kittel-type domain patterns, in 300 nm thick single-crystal BaTiO3 platelets. As the microstructural development proceeds, the rate of change of the domain configuration is seen to decrease exponentially. Nevertheless, domain wall velocities throughout are commensurate with creep processes in oxide ferroelectrics. Progressive screening of macroscopic destabilizing fields, primarily the surface-related depolarizing field, successfully describes the main features of the observed kinetics. Changes in the separation of domain-wall vertex junctions prompt a consideration that vertex−vertex interactions could be influencing the measured kinetics. However, the expected dynamic signatures associated with direct vertex−vertex interactions are not resolved. If present, our measurements confine the length scale for interaction between vertices to the order of a few hundred nanometers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The German Federal Constitutional Court (FCC) ruling of 14 January 2014 deserves a thorough evaluation on several accounts: It is the first ever reference by the FCC to the Court of Justice of the European Union (CJEU), it represents a continuation of FCC case law aimed at restricting the impact of European Union law as interpreted by the Court of Justices of the European Union (CJEU) on German law as well as questioning Germany’s participation in an ever closer European Union, and it has the potential to dictate the future course of the EU’s Economic and Monetary Union (EMU).

This case note discusses three aspects of this decision. First, it considers the aims of challenging the youngest measures to contain the euro currency crisis before the FCC, focusing on the question in how far the claims are based on national closure as opposed to an ever closer union of the peoples of Europe. Secondly it analyzes in how far the aims the claims pursue are reflected in the FCC’s response. Thirdly, it considers the substantive relevance of this reference, highlighting the surprisingly vague consequences the FCC envisages should the CJEU not re-interpret the OMT decision as the FCC suggests, and illuminating the strategic aims of the reference without deference. In conclusion, it sketches the remaining scope for the EU to engage in or at least facilitate transnational solidarity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new perceptual watermarking model for Discrete Shearlet transform (DST). DST provides the optimal representation [10] of the image features based on multi-resolution and multi-directional analysis. This property can be exploited on for watermark embedding to achieve the watermarking imperceptibility by introducing the human visual system using Chou’s model. In this model, a spatial JND profile is adapted to fit the sub-band structure. The combination of DST and the Just-Noticeable Distortion (JND) profile improves the levels of robustness against certain attacks while minimizing the distortion; by assigning a visibility threshold of distortion to each DST sub-band coefficient in the case of grey scale image watermarking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To intercept a moving object, one needs to be in the right place at the right time. In order to do this, it is necessary to pick up and use perceptual information that specifies the time to arrival of an object at an interception point. In the present study, we examined the ability to intercept a laterally moving virtual sound object by controlling the displacement of a sliding handle and tested whether and how the interaural time difference (ITD) could be the main source of perceptual information for successfully intercepting the virtual object. The results revealed that in order to accomplish the task, one might need to vary the duration of the movement, control the hand velocity and time to reach the peak velocity (speed coupling), while the adjustment of movement initiation did not facilitate performance. Furthermore, the overall performance was more successful when subjects employed a time-to-contact (tau) coupling strategy. This result shows that prospective information is available in sound for guiding goal-directed actions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors appreciate the discusser’s interest in the original paper and for the valuable discussion, which provides the opportunity to clarify and reiterate a few points made in the original paper. The comments and questions raised by the discusser are addressed in the following sections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter covers the indications, contraindications, techniques, outcomes, and complications of LPI. Its role is well defined in most of the areas, but no conclusion can be drawn at present regarding prophylactic use for glaucoma suspects. More studies are needed to define its safety and efficacy. Overall, LPI is a relatively safe procedure and the majority of complications can be avoided if it is performed properly.