922 resultados para Padrão de torque
Resumo:
Background: This study investigated the influence of estrogen deficiency and its treatment with estrogen and alendronate on the removal torque of osseointegrated titanium implants.Methods: Fifty-eight female Wistar rats received a titanium implant in the tibia metaphysis. After 60 days, which was needed for implant osseointegration, the animals were randomly divided into five groups: control (CTLE; N = 10), sham surgery (SHAM; N = 12), ovariectomy (OVX; N = 12), ovariectomy followed by hormone replacement (EST; N = 12), and ovariectomy followed by treatment with alendronate (ALE; N = 12). The CTLE group was sacrificed to confirm osseointegration, whereas the remaining groups were submitted to sham surgery or ovariectomy according to their designations. After 90 days, these animals were also sacrificed. Densitometry of femur and lumbar vertebrae was performed by dual-energy x-ray absorptiometry (DXA) to confirm systemic impairment of the animals. All implants were subjected to removal torque.Results: Densitometric analysis of the femur and lumbar vertebrae confirmed a systemic impairment of the animals, disclosing lower values of bone mineral density for OVX. Analysis of the removal torque of the implants showed statistically lower values (P <0.05) for the OVX group in relation to the other groups. However, the group treated with alendronate (ALE group) presented significantly higher torque values compared to the others.Conclusion: According to this study, estrogen deficiency was observed to have a negative influence on the removal torque of osseointegrated implants, whereas treatment with alendronate
Resumo:
An analytical approach for the spin stabilized satellite attitude propagation is presented using the non-singular canonical variables to describe the rotational motion. Two sets of variables were introduced for Fukushima in 1994 by a canonical transformation and they are useful when the angle between z-satellite axis of a coordinate system fixed in artificial satellite and the rotational angular momentum vector is zero or when the angle between Z-equatorial axis and rotation angular momentum vector is zero. Analytical solutions for rotational motion equations and torque-free motion are discussed in terms of the elliptic functions and by the application of some simplification to get an approximated solution. These solutions are compared with a numerical solution and the results show a good agreement for many rotation periods. When the mean Hamiltonian associated with the gravity gradient torque is included, an analytical solution is obtained by the application of the successive approximations' method for the satellite in an elliptical orbit. These solutions show that the magnitude of the rotation angular moment is not affected by the gravity gradient torque but this torque causes linear and periodic variations in the angular variables, long and short periodic variations in Z-equatorial component of the rotation angular moment and short periodic variations in x-satellite component of the rotation angular moment. The goal of this analysis is to emphasize the geometrical and physical meaning of the non-singular variables and to validate the approximated analytical solution for the rotational motion without elliptic functions for a non-symmetrical satellite. The analysis can be applied for spin stabilized satellite and in this case the general solution and the approximated solution are coincidence. Then the results can be used in analysis of the space mission of the Brazilian Satellites. (C) 2007 COSPAR. Published by Elsevier Ltd. All rights reserved.
Resumo:
The purpose of this study was to determine the accuracy of mechanical torque devices in delivering target torque values in dental offices in Salvador, Brazil. A team of researchers visited 16 dental offices, and the clinicians applied torque values (20 and 32 Ncm) to electronic torque controllers. Five repetitions were completed at each torque value and data were collected. When 20 Ncm of torque was used, 62.5% of measured values were accurate (within 10% of the target value). For 32 Ncm, however, only 37.5% of these values were achieved. Several of the tested mechanical torque devices were inaccurate. Int J Prosthodont 2011;24:38-39.
Resumo:
Objective The aim of this study was to compare intrapulpal temperature increases produced by a high-speed high-torque (speed-increasing) handpiece, a high-speed low-torque handpiece (air-turbine) and an Er: YAG (Erbium: Yttrium-Aluminum-Garnet) laser. Subject and methods Thirty bovine incisors were reduced to a dentine thickness of 2.0 mm. Class V preparations were prepared to a depth of 1.5 mm, measured with a caliper or by a mark on the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (C). Analysis was performed on the following groups (n = 10) treated with: G1, low-torque handpiece; G2, high-torque handpiece; and G3, Er: YAG laser (2.94 mu m at 250 mJ/4 Hz), all with water cooling. The temperature increases were recorded with a computer linked to the thermocouples. Results The data were submitted to ANOVA and Tukey statistical test. The average temperature rises were: 1.92 +/- 0.80 degrees C for G1, 1.34 +/- 0.86 degrees C for G2, and 0.75 +/- 0.39 degrees C for G3. There were significant statistical differences among the groups (p = 0.095). All the groups tested did not have a change of temperature that exceeds the threshold of 5.5 degrees C. Conclusion Temperature response to the low and high torque handpieces seemed to be similar, however the Er: YAG laser generated a lower temperature rise.
Resumo:
Using a canonical formulation, the stability of the rotational motion of artificial satellites is analyzed considering perturbations due to the gravity gradient torque. Here Andoyer's variables are used to describe the rotational motion. One of the approaches that allow the analysis of the stability of Hamiltonian systems needs the reduction of the Hamiltonian to a normal form. Firstly equilibrium points are found. Using generalized coordinates, the Hamiltonian is expanded in the neighborhood of the linearly stable equilibrium points. In a next step a canonical linear transformation is used to diagonalize the matrix associated to the linear part of the system. The quadratic part of the Hamiltonian is normalized. Based in a Lie-Hori algorithm a semi-analytic process for normalization is applied and the Hamiltonian is normalized up to the fourth order. Once the Hamiltonian is normalized up to order four, the analysis of stability of the equilibrium point is performed using the theorem of Kovalev and Savichenko. This semi-analytical approach was applied considering some data sets of hypothetical satellites. For the considered satellites it was observed few cases of stable motion. This work contributes for space missions where the maintenance of spacecraft attitude stability is required.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A semi-analytical approach is proposed to study the rotational motion of an artificial satellite under the influence of the torque due to the solar radiation pressure and taking into account the influence of Earth's shadow. The Earth's shadow is introduced in the equations for the rotational motion as a function depending on the longitude of the Sun, on the ecliptic's obliquity and on the orbital parameters of the satellite. By mapping and computing this function, we can get the periods in which the satellite is not illuminated and the torque due to the solar radiation pressure is zero. When the satellite is illuminated, a known analytical solution is used to predict the satellite's attitude. This analytical solution is expressed in terms of Andoyer's variables and depends on the physical and geometrical properties of the satellite and on the direction of the Sun radiation flux. By simulating a hypothetical circular cylindrical type satellite, an example is exhibited and the results agree quite well when compared with a numerical integration. © 1997 COSPAR. Published by Elsevier Science Ltd.
Resumo:
Enterobacter spp. are considered important causing agents of infection, specially in hospitalized individuals. The natural resistance of these microorganisms and the great facility to develop resistance to new antimicrobial agents make this genus an important object of study. In this work, 176 strains isolated from various clinical samples were used from hospitalized patients (University Hospital Domingos Leonardo Cerávolo) and from clinic patients (Clinical Laboratory from Unoeste), both situated in Presidente Prudente - SP. E. cloacae (78.9%), E. aerogenes (7.9%) and E. (pantoea) agglomerans (3.9%) were the ones more frequently isolated. Eleven antimicrobial agents were tested by the disk diffusion method and around 90% of the strains presented resistance to the cephalotin, ampicillin and cefaclor. Strains of E. (pantoea) agglomerans presented wide profile of sensibility However one strain of E. cloacae presented resistance to all the antimicrobial agents. The antimicrobial agents with greater inhibitory activity were imipenem and cefepime, for this reason these antimicrobial agents could be the treatment of choice in emergencial therapeutic. This emergencial therapy can be applied with relative security, whereas the data obtained in this study show homogeneity in the profile of sensibility to these antimicrobial agents, independent of the infection site and from the isolated species. The ESBL enzyme could not be detected in no one of the strains by the double diffusion test.
Resumo:
The aim of this study was the assessment of isolation frequency and antimicrobial susceptibility pattern of nonfermenting Gram-negative bacilli. Ninety eight strains of nonfermenting Gram-negative bacilli, isolated from several clinical materials of patients admited at the Dr. Domingos Leonardo Cerávolo University Hospital and at Dr. Odilo Antunes Siqueira State Hospital, as well as from every outpatient; assisted at Laboratory of Clinical Analysis of Unoeste University, Presidente Prudente, São Paulo, in the period of October 1999 to April 2001 were analyzed. The most frequent species were Pseudomonas aeruginosa (65.3%) and Acinetobacter baumannii (23.5%). The frequency of the other isolated species was smaller than 2.5%. In the antimicrobial susceptibility tests, the two species more prevalent showed high resistance. The antibiotic most active in vitro was the imipenem, with 79.6% in microdiluition method, and 76.6% in diffusion method, for Pseudomonas aeruginosa strains and 100.0% in both microdiluition and diffusion methods, for Acinetobacter baumannii. The cephalosporins of third generation, the ciprofloxacin and the aminoglycosides, presented percentage of susceptibility varying from 22.4 to 69.7%. These results bring implications to the emergency use of the antimicrobial agents in the treatment of patients with severe infection.
O novo padrão de desenvolvimento agroindustrial e a atuação das cooperativas agropecuárias no Paraná
Resumo:
This article aims at discussing the transformations in the cooperativist rural sector in the state of Paraná since 1970. Considerable active agents in the process of modernization in the agriculture from Paraná, the cooperatives developed also an important role in the productive restructuralization in the State of Paraná, when they started the agroindustrial activities. The verticalization represented a big growth of the cooperatives that act in the rural area, but it also implied in a redirection of the cooperatives' strategies, that started acting in an extremely competitive market.
Resumo:
Female broiler breeder productivity is based on the principles of thermal comfort that are directly related with the microclimate inside the housing. This research had the objective of monitoring the behavior of female broiler breeders, using the technology of radio-frequency, injectable transponders and readers in different existing microclimates inside a small scale distorted housing model. Eight birds with electronic identification were used. Three readers were used, in three different points inside the model: on the floor of the nest, in the passage besides the lateral wall and below the water facility. Dry bulb (DBT), wet bulb (WBT) and black globe (BGT) temperature were measured continuously. The results point out a distinct behavioral pattern of the birds regarding the environment exposition during the experiment. Three probabilistic models of behavior were developed from the recorded data: probabilistic model for the passage use: FP = 1.10 - 0.244 ln(DBT), probabilistic model for the water facility use: FB = 0.398 + 0.00866(DBT), and probabilistic model for the nest use: FN = 2.22 - 0.272 DBT + 0,011 DBT 2 - 0.000144 DBT 3.
Resumo:
Objective: To determine the accuracy of the variables related to the fixed-height stair-climbing test (SCT) using maximal oxygen uptake (V̇O 2 max) as the gold standard. Methods: The SCT was performed on a staircase consisting of 6 flights (72 steps; 12.16 m total height), with verbal encouragement, in 51 patients. Stair-climbing time was measured, the variables 'work' and 'power' also being calculated. The V̇O2 max was measured using ergospirometry according to the Balke protocol. We calculated the Pearson linear correlation (r), as well as the values of p, between the SCT variables and V̇O2 max. To determine accuracy, the V̇O 2 max cut-off point was set at 25 mL/kg/min, and individuals were classified as normal or altered. The cut-off points for the SCT variables were determined using the receiver operating characteristic curve. The Kappa statistic (k) was used in order to assess concordance. Results: The following values were obtained for the variable 'time': cut-off point = 40 s; mean = 41 ± 15.5 s; r = -0.707; p < 0.005; specificity = 89%; sensibility = 83%; accuracy = 86%; and k = 0.724. For 'power', the values obtained were as follows: cut-off point = 200 w; mean = 222.3 ± 95.2 w; r = 0.515; p < 0.005; specificity = 67%; sensibility= 75%; accuracy = 71%; and k = 0.414. Since the correlation between the variable 'work' and V̇O2 max was not significant, that variable was discarded. Conclusion: Of the SCT variables tested, using V̇O2 max as the gold standard, the variable 'time' was the most accurate.