987 resultados para PRESSURE MEASUREMENT
Resumo:
PURPOSE: 1. Identify differences in optic nerve sheath diameter (ONSD) as an indirect measure of intracranial pressure (ICP) in glaucoma patients and a healthy population. 2. Identify variables that may correlate with ONSD in primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG) patients. METHODS: Patients with NTG (n = 46) and POAG (n = 61), and healthy controls (n = 42) underwent B-scan ultrasound measurement of ONSD by an observer masked to the patient diagnosis. Intraocular pressure (IOP) was measured in all groups, with additional central corneal thickness (CCT) and visual field defect measurements in glaucomatous patients. Only one eye per patient was selected. Kruskal-Wallis or Mann-Whitney were used to compare the different variables between the diagnostic groups. Spearman correlations were used to explore relationships among these variables. RESULTS: ONSD was not significantly different between healthy, NTG and POAG patients (6.09 ± 0.78, 6.03 ± 0.69, and 5.71 ± 0.83 respectively; p = 0.08). Visual field damage and CCT were not correlated with ONSD in either of the glaucoma groups (POAG, p = 0.31 and 0.44; NTG, p = 0.48 and 0.90 respectively). However, ONSD did correlate with IOP in NTG patients (r = 0.53, p < 0.001), while it did not in POAG patients and healthy controls (p = 0.86, p = 0.46 respectively). Patient's age did not relate to ONSD in any of the groups (p > 0.25 in all groups). CONCLUSIONS: Indirect measurements of ICP by ultrasound assessment of the ONSD may provide further insights into the retrolaminar pressure component in glaucoma. The correlation of ONSD with IOP solely in NTG patients suggests that the translaminar pressure gradient may be of particular importance in this type of glaucoma.
Resumo:
The spinning rotor gauge (SRG) is one of the most interesting vacuum gauges ever made, covering a pressure range of over seven orders of magnitude, with minimal gas interference (no pumping, ionization or heating of the measured gas), and a great stability of less than 1% drift per year. But despite its remarkable properties, apparently the SRG has not been further developed since the eighties, when it gained commercial interest. In this context, this dissertation aims at providing a starting point for a new line of investigation regarding this instrument, focused on the rotor itself. A brief study of different rotor geometries is provided, including a comparison between a cylindrical rotor and a spherical one. A cylindrical spinning rotor gauge (CSRG) is then proposed, based on the original SRG, but requiring a completely new lateral damping system. A prototype was built and tested against a non calibrated reference gauge.
Resumo:
This paper reports the fabrication process and characterization of a flexible pressure sensor based on polydimethylsiloxane (PDMS) and multi-walled carbon nanotubes (CNT-PDMS). The proposed approach relies on patterned CNT-PDMS nanocomposite strain gauges fabricated with SU-8 microstructures (with the micropatterns) in a low‑cost and simple fabrication process. This nanocomposite polymer is mounted over a PDMS membrane, which, in turn, lies on top of a PDMS diaphragm like structure. This configuration enables the PDMS membrane to bend when pressure is applied, thereby affecting the nanocomposite strain gauges, effectively changing their electrical resistance. Carbon nanotubes have several advantages such as excellent mechanical properties, high electrical conductivity and thermal stability. Furthermore, the measurement range of the proposed sensor can be adapted according to the application by varying the CNTs content and geometry of microstructure. In addition, the sensor’s biocompatibility, low cost and simple fabrication makes it very appealing for biomechanical strain sensing. The sensor’s sensitivity was about 0.073%ΔR/mmHg.
Resumo:
Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.
Resumo:
Abstract Background: Labdane-type diterpenes induce lower blood pressure via relaxation of vascular smooth muscle; however, there are no studies describing the effects of labdanes in hypertensive rats. Objective: The present study was designed to investigate the cardiovascular actions of the labdane-type diterpene ent-3-acetoxy-labda-8(17), 13-dien-15-oic acid (labda-15-oic acid) in two-kidney 1 clip (2K-1C) renal hypertension. Methods: Vascular reactivity experiments were performed in aortic rings isolated from 2K-1C and normotensive (2K) male Wistar rats. Nitrate/nitrite (NOx) measurement was performed in aortas by colorimetric assay. Blood pressure measurements were performed in conscious rats. Results: Labda-15-oic acid (0.1-300 µmol/l) and forskolin (0.1 nmol/l - 1 µmol/l) relaxed endothelium-intact and endothelium-denuded aortas from both 2K-1C and 2K rats. Labda-15-oic acid was more effective at inducing relaxation in endothelium-intact aortas from 2K pre-contracted with phenylephrine when compared to the endothelium-denuded ones. Forskolin was more potent than labda-15-oic acid at inducing vascular relaxation in arteries from both 2K and 2K-1C rats. Labda-15-oic acid-induced increase in NOx levels was lower in arteries from 2K-1C rats when compared to 2K rats. Intravenous administration of labda-15-oic acid (0.3-3 mg/kg) or forskolin (0.1-1 mg/kg) induced hypotension in conscious 2K-1C and 2K rats. Conclusion: The present findings show that labda-15-oic acid induces vascular relaxation and hypotension in hypertensive rats.
Resumo:
Abstract Hypertension affects 25% of the world's population and is considered a risk factor for cardiovascular disorders and other diseases. The aim of this study was to examine the evidence regarding the acute effect of exercise on blood pressure (BP) using meta-analytic measures. Sixty-five studies were compared using effect sizes (ES), and heterogeneity and Z tests to determine whether the ES were different from zero. The mean corrected global ES for exercise conditions were -0.56 (-4.80 mmHg) for systolic BP (sBP) and -0.44 (-3.19 mmHg) for diastolic BP (dBP; z ≠ 0 for all; p < 0.05). The reduction in BP was significant regardless of the participant's initial BP level, gender, physical activity level, antihypertensive drug intake, type of BP measurement, time of day in which the BP was measured, type of exercise performed, and exercise training program (p < 0.05 for all). ANOVA tests revealed that BP reductions were greater if participants were males, not receiving antihypertensive medication, physically active, and if the exercise performed was jogging. A significant inverse correlation was found between age and BP ES, body mass index (BMI) and sBP ES, duration of the exercise's session and sBP ES, and between the number of sets performed in the resistance exercise program and sBP ES (p < 0.05). Regardless of the characteristics of the participants and exercise, there was a reduction in BP in the hours following an exercise session. However, the hypotensive effect was greater when the exercise was performed as a preventive strategy in those physically active and without antihypertensive medication.
Resumo:
OBJECTIVE: To reach a consensus on the clinical use of ambulatory blood pressure monitoring (ABPM). METHODS: A task force on the clinical use of ABPM wrote this overview in preparation for the Seventh International Consensus Conference (23-25 September 1999, Leuven, Belgium). This article was amended to account for opinions aired at the conference and to reflect the common ground reached in the discussions. POINTS OF CONSENSUS: The Riva Rocci/Korotkoff technique, although it is prone to error, is easy and cheap to perform and remains worldwide the standard procedure for measuring blood pressure. ABPM should be performed only with properly validated devices as an accessory to conventional measurement of blood pressure. Ambulatory recording of blood pressure requires considerable investment in equipment and training and its use for screening purposes cannot be recommended. ABPM is most useful for identifying patients with white-coat hypertension (WCH), also known as isolated clinic hypertension, which is arbitrarily defined as a clinic blood pressure of more than 140 mmHg systolic or 90 mmHg diastolic in a patient with daytime ambulatory blood pressure below 135 mmHg systolic and 85 mmHg diastolic. Some experts consider a daytime blood pressure below 130 mmHg systolic and 80 mmHg diastolic optimal. Whether WCH predisposes subjects to sustained hypertension remains debated. However, outcome is better correlated to the ambulatory blood pressure than it is to the conventional blood pressure. Antihypertensive drugs lower the clinic blood pressure in patients with WCH but not the ambulatory blood pressure, and also do not improve prognosis. Nevertheless, WCH should not be left unattended. If no previous cardiovascular complications are present, treatment could be limited to follow-up and hygienic measures, which should also account for risk factors other than hypertension. ABPM is superior to conventional measurement of blood pressure not only for selecting patients for antihypertensive drug treatment but also for assessing the effects both of non-pharmacological and of pharmacological therapy. The ambulatory blood pressure should be reduced by treatment to below the thresholds applied for diagnosing sustained hypertension. ABPM makes the diagnosis and treatment of nocturnal hypertension possible and is especially indicated for patients with borderline hypertension, the elderly, pregnant women, patients with treatment-resistant hypertension and patients with symptoms suggestive of hypotension. In centres with sufficient financial resources, ABPM could become part of the routine assessment of patients with clinic hypertension. For patients with WCH, it should be repeated at annual or 6-monthly intervals. Variation of blood pressure throughout the day can be monitored only by ABPM, but several advantages of the latter technique can also be obtained by self-measurement of blood pressure, a less expensive method that is probably better suited to primary practice and use in developing countries. CONCLUSIONS: ABPM or equivalent methods for tracing the white-coat effect should become part of the routine diagnostic and therapeutic procedures applied to treated and untreated patients with elevated clinic blood pressures. Results of long-term outcome trials should better establish the advantage of further integrating ABPM as an accessory to conventional sphygmomanometry into the routine care of hypertensive patients and should provide more definite information on the long-term cost-effectiveness. Because such trials are not likely to be funded by the pharmaceutical industry, governments and health insurance companies should take responsibility in this regard.
Resumo:
Measuring tissue oxygenation in vivo is of interest in fundamental biological as well as medical applications. One minimally invasive approach to assess the oxygen partial pressure in tissue (pO2) is to measure the oxygen-dependent luminescence lifetime of molecular probes. The relation between tissue pO2 and the probes' luminescence lifetime is governed by the Stern-Volmer equation. Unfortunately, virtually all oxygen-sensitive probes based on this principle induce some degree of phototoxicity. For that reason, we studied the oxygen sensitivity and phototoxicity of dichlorotris(1, 10-phenanthroline)-ruthenium(II) hydrate [Ru(Phen)] using a dedicated optical fiber-based, time-resolved spectrometer in the chicken embryo chorioallantoic membrane. We demonstrated that, after intravenous injection, Ru(Phen)'s luminescence lifetime presents an easily detectable pO2 dependence at a low drug dose (1 mg∕kg) and low fluence (120 mJ∕cm2 at 470 nm). The phototoxic threshold was found to be at 10 J∕cm2 with the same wavelength and drug dose, i.e., about two orders of magnitude larger than the fluence necessary to perform a pO2 measurement. Finally, an illustrative application of this pO2 measurement approach in a hypoxic tumor environment is presented.
Resumo:
AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.
Resumo:
Given the increasing use of ambulatory blood pressure monitoring (ABPM) in both clinical practice and hypertension research, a group of scientists, participating in the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability, in year 2013 published a comprehensive position paper dealing with all aspects of the technique, based on the available scientific evidence for ABPM. The present work represents an updated schematic summary of the most important aspects related to the use of ABPM in daily practice, and is aimed at providing recommendations for proper use of this technique in a clinical setting by both specialists and practicing physicians. The present article details the requirements and the methodological issues to be addressed for using ABPM in clinical practice, The clinical indications for ABPM suggested by the available studies, among which white-coat phenomena, masked hypertension, and nocturnal hypertension, are outlined in detail, and the place of home measurement of blood pressure in relation to ABPM is discussed. The role of ABPM in pharmacological, epidemiological, and clinical research is also briefly mentioned. Finally, the implementation of ABPM in practice is considered in relation to the situation of different countries with regard to the reimbursement and the availability of ABPM in primary care practices, hospital clinics, and pharmacies.
Resumo:
This study aimed to design and validate the measurement of ankle kinetics (force, moment, and power) during consecutive gait cycles and in the field using an ambulatory system. An ambulatory system consisting of plantar pressure insole and inertial sensors (3D gyroscopes and 3D accelerometers) on foot and shank was used. To test this system, 12 patients and 10 healthy elderly subjects wore shoes embedding this system and walked many times across a gait lab including a force-plate surrounded by seven cameras considered as the reference system. Then, the participants walked two 50-meter trials where only the ambulatory system was used. Ankle force components and sagittal moment of ankle measured by ambulatory system showed correlation coefficient (R) and normalized RMS error (NRMSE) of more than 0.94 and less than 13% in comparison with the references system for both patients and healthy subjects. Transverse moment of ankle and ankle power showed R>0.85 and NRMSE<23%. These parameters also showed high repeatability (CMC>0.7). In contrast, the ankle coronal moment of ankle demonstrated high error and lower repeatability. Except for ankle coronal moment, the kinetic features obtained by the ambulatory system could distinguish the patients with ankle osteoarthritis from healthy subjects when measured in 50-meter trials. The proposed ambulatory system can be easily accessible in most clinics and could assess main ankle kinetics quantities with acceptable error and repeatability for clinical evaluations. This system is therefore suggested for field measurement in clinical applications.
Resumo:
The blood pressure (BP), heart rate (HR), and humoral effects of single intravenous (i.v.) doses of the angiotensin-converting enzyme (ACE) inhibitor captopril was investigated in five normotensive healthy volunteers. Each subject received at 1-week intervals a bolus dose of either captopril (1, 5, and 25 mg) or its vehicle. The study was conducted in a single-blind fashion, and the order of treatment phases was randomized. The different doses of captopril had no acute effect on BP and HR. They induced a dose-dependent decrease in plasma ACE activity and plasma angiotensin II levels. The angiotensin-(1-8) octapeptide was isolated by solid-phase extraction and high-performance liquid chromatography (HPLC) prior to radioimmunoassay (RIA). All three doses of captopril reduced circulating angiotensin II levels within 15 min of drug administration. Only with the 25-mg dose was the angiotensin II concentration below the detection limit at 15 min and still significantly reduced 90 min after drug administration. Simultaneous and progressive decreases in plasma aldosterone levels were observed both with ACE inhibition and during vehicle injection, but the relative fall was more pronounced after captopril administration. No adverse reaction was noticed. These results demonstrate that captopril given parenterally blocks the renin-angiotensin system in a dose-dependent manner. Only with the dose of 25 mg was the inhibition of plasma-converting enzyme activity and the reduction of plasma angiotensin II sustained for at least 1 1/2 h.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
Introduction: Nasal continuous positive airways pressure (n-CPAP) is an effective treatment in premature infants with respiratory distress. The cardio-pulmonary interactions secondary to n-CPAP are well studied in adults, but less well described in premature infants. We postulated that there could be important interactions with regard to the patent ductus arteriosus (PDA). Methods: Prospective study, approved by the local ethic committee. Premature infants less than 32 weeks gestation, _7 days-old, needing n-CPAP for respiratory distress, but without the need of additional oxygen were included in the study. Every patient had a first echocardiography with n-CPAP and then n-CPAP was retrieved. 3 hours later the echocardiography was repeated by the same investigator and then the patient replaced on n-CPAP. Results: 14 premature newborn were included, mean gestational age of 28 _ 2 weeks, mean weight 1.1 _ 0.3 Kg and height 39 _ 3 cm. Echocardiographic measurements are depicted in Table 1. Significant finding were observed between measurement on n- CPAP or without n-CPAP: on end diastolic left ventricular diameter (12.8 _ 1.6 mm vs. 13.5 _ 2 mm), on end systolic left ventricular diameter (8.4 _ 1.3 mm vs. 9.1 _ 1.5 mm), left atrium diameter (8.9 _ 2.2 mm vs. 10.4 _ 2.5 mm), maximal velocity on tricuspid valve (46 _ 10 cm/s vs. 51 _ 9 cm/s), calculated Qp (3.7 _ 0.8 L/min/m2 vs. 4.3 _ 0.8 L/min/m2). Only three patients have demonstrated a PDA during the study. Conclusion: Positive end expiratory pressure (Peep) has hemodynamic effects which are: reduction of systemic and pulmonary venous return as shown by the changes on tricuspid valve inflow,on the calculated Qp and finally on the diameter of the left atrium and left ventricle.We found in premature infants the same hemodynamic effects than those described in adults but with lower Peep values. This could be due to the particular elasticity and weakness of the thoracic wall of premature infants. Interestingly the flow through a PDA seems also to be diminished with Peep, but the number of patients is insufficient to conclude. Further investigation will be needed to better understand these interactions. Table 1. Echocardiographic measurement (mean (SD)). With n-CPAP Without n-CPAP p value RV ED diameter (mm) 6.3 (1.7) 6.04 (1.1) NS LV ED diameter (mm) 12.8 (1.6) 13.5 (2.0) _0.05 LV ES diameter (mm) 8.4 (1.3) 9.1 (1.5) _0.05 SF (%) 34 (5) 33 (6) NS Ao valve diameter (mm) 7.4 (1.3) 7.4 (1.2) NS LA diameter (mm) 8.9 (2.2) 10.4 (2.5) _0.05 Vmax Ao (cm/s) 70 (16) 71 (18) NS Vmax PV (cm/s) 69 (15) 72 (16) NS Vmax TV (cm/s) 46 (10) 51 (9) _0.05 Vmax MV (cm/s) 53 (17) 54 (18) NS Qp (L/min/m2) 3.7 (0.8) 4.3 (0.8) _0.05 Qs (L/min/m2) 4.0 (0.8) 4.0 (0.7) NS Qp/Qs 0.92 (0.14) 1.09 (0.23) _0.05 RV: right ventricle, LV: left ventricle, ED: end diastolic, ES: end systolic, SF: shortening fraction,Ao: aortic valve, LA: left atrium,Vmax: maximum Doppler Velocity, Qp: pulmonary output, Qs: systemic output, NS: non significant.
Resumo:
Background: Recent reviews of randomized control trials have shown that pharmacist interventions improve cardiovascular diseases (CVD) risk factors in outpatients. Various interventions were evaluated in different settings, and a substantial heterogeneity was observed in the effect estimates. To better express uncertainties in the effect estimates, prediction intervals (PI) have been proposed but are, however, rarely reported. Objective: Pooling data from two systematic reviews, we estimated the effect of pharmacist interventions on systolic blood pressure (BP), computed PI, and evaluated potential causes of heterogeneity. Methods: Data were pooled from systematic reviews assessing the effect of pharmacist interventions on CVD risk factors in patients with or without diabetes, respectively. Effects were estimated using random effect models. Results: Systolic BP was the outcome in 31 trials including 12 373 patients. Pharmacist interventions included patient educational interventions, patient-reminder systems, measurement of BP, medication management and feedback to physician, or educational intervention to health care professionals. Pharmacist interventions were associated with a large reduction in systolic BP (-7.5 mmHg; 95% CI: -9.0 to -5.9). There was a substantial heterogeneity (I2: 66%). The 95% PI ranged from -13.9 to -1.0 mmHg. The effect tended to be larger if the intervention was conducted in a community pharmacy and if the pharmacist intervened at least monthly. Conclusion: On average, the effect of pharmacist interventions on BP was substantial. However, the wide PI suggests that the effect differed between interventions, with some having modest effects and others very large effects on BP. Part of the heterogeneity could be due to differences in the setting and in the frequency of the interventions.