995 resultados para Orthopedic fixation devices
Resumo:
In recent years, XML has been accepted as the format of messages for several applications. Prominent examples include SOAP for Web services, XMPP for instant messaging, and RSS and Atom for content syndication. This XML usage is understandable, as the format itself is a well-accepted standard for structured data, and it has excellent support for many popular programming languages, so inventing an application-specific format no longer seems worth the effort. Simultaneously with this XML's rise to prominence there has been an upsurge in the number and capabilities of various mobile devices. These devices are connected through various wireless technologies to larger networks, and a goal of current research is to integrate them seamlessly into these networks. These two developments seem to be at odds with each other. XML as a fully text-based format takes up more processing power and network bandwidth than binary formats would, whereas the battery-powered nature of mobile devices dictates that energy, both in processing and transmitting, be utilized efficiently. This thesis presents the work we have performed to reconcile these two worlds. We present a message transfer service that we have developed to address what we have identified as the three key issues: XML processing at the application level, a more efficient XML serialization format, and the protocol used to transfer messages. Our presentation includes both a high-level architectural view of the whole message transfer service, as well as detailed descriptions of the three new components. These components consist of an API, and an associated data model, for XML processing designed for messaging applications, a binary serialization format for the data model of the API, and a message transfer protocol providing two-way messaging capability with support for client mobility. We also present relevant performance measurements for the service and its components. As a result of this work, we do not consider XML to be inherently incompatible with mobile devices. As the fixed networking world moves toward XML for interoperable data representation, so should the wireless world also do to provide a better-integrated networking infrastructure. However, the problems that XML adoption has touch all of the higher layers of application programming, so instead of concentrating simply on the serialization format we conclude that improvements need to be made in an integrated fashion in all of these layers.
Resumo:
Of the many factors that govern the settling phenomenon, the flow velocity in the settling tanks can be controlled favorably by fixing suitably designed weirs at the outlets of the tanks. The velocity at the bottom should not dislodge the particles that have already settled. These requirements might be met with by velocities which are controlled to be constant with respect to the depth of flow, or velocities which reduce linearly with increasing depth or velocities that vary inversely with the depth. To achieve these types of velocity control, new proportional weirs have been designed. Very near to the outlet of the tank, over a small length, the flow was found to be turbulent and noncompliant with the expected type of velocity control. This small length of the disturbance may be provided over and above the theoretical settling length of the tank, for efficient sedimentation.
Resumo:
Purpose: This paper reviews the apparatus used for deformation of bone fracture fixation plates during orthopaedic surgeries including surgical irons, pliers and bending press tools. This paper extends the review to various machineries in non-medical industries and adopts their suitability to clinics-related applications and also covers the evolution of orthopaedic bone plates. This review confirms that none of the studied machineries can be implemented for the deformation of bone fracture fixation plates during orthopaedic surgeries. In addition, this paper also presents the novel apparatus that are designed from scratch for this specific purpose. Several conceptual designs have been proposed and evaluated recently. It has been found that Computer Numerical Control (CNC) systems are not the golden solution to this problem and one needs to attempt to design the robotic arm system. A new design of robotic arm that can be used for facilitating orthopaedic surgeries is being completed.
Resumo:
We report the material and electrical properties of Erbium Oxide (Er2O3) thin films grown on n-Ge (100) by RF sputtering. The properties of the films are correlated with the processing conditions. The structural characterization reveals that the films annealed at 550 degrees C, has densified as compared to the as-grown ones. Fixed oxide charges and interface charges, both of the order of 10(13)/cm(2) is observed.
Resumo:
Background and aims. Since 1999, hospitals in the Finnish Hospital Infection Program (SIRO) have reported data on surgical site infections (SSI) following major hip and knee surgery. The purpose of this study was to obtain detailed information to support prevention efforts by analyzing SIRO data on SSIs, to evaluate possible factors affecting the surveillance results, and to assess the disease burden of postoperative prosthetic joint infections in Finland. Methods. Procedures under surveillance included total hip (THA) and total knee arthroplasties (TKA), and the open reduction and internal fixation (ORIF) of femur fractures. Hospitals prospectively collected data using common definitions and written protocol, and also performed postdischarge surveillance. In the validation study, a blinded retrospective chart review was performed and infection control nurses were interviewed. Patient charts of deep incisional and organ/space SSIs were reviewed, and data from three sources (SIRO, the Finnish Arthroplasty Register, and the Finnish Patient Insurance Centre) were linked for capture-recapture analyses. Results. During 1999-2002, the overall SSI rate was 3.3% after 11,812 orthopedic procedures (median length of stay, eight days). Of all SSIs, 56% were detected after discharge. The majority of deep incisional and organ/space SSIs (65/108, 60%) were detected on readmission. Positive and negative predictive values, sensitivity, and specificity for SIRO surveillance were 94% (95% CI, 89-99%), 99% (99-100%), 75% (56-93%), and 100% (97-100%), respectively. Of the 9,831 total joint replacements performed during 2001-2004, 7.2% (THA 5.2% and TKA 9.9%) of the implants were inserted in a simultaneous bilateral operation. Patients who underwent bilateral operations were younger, healthier, and more often males than those who underwent unilateral procedures. The rates of deep SSIs or mortality did not differ between bi- and uni-lateral THAs or TKAs. Four deep SSIs were reported following bilateral operations (antimicrobial prophylaxis administered 48-218 minutes before incision). In the three registers, altogether 129 prosthetic joint infections were identified after 13,482 THA and TKA during 1999-2004. After correction with the positive predictive value of SIRO (91%), a log-linear model provided an estimated overall prosthetic joint infection rate of 1.6% after THA and 1.3% after TKA. The sensitivity of the SIRO surveillance ranged from 36% to 57%. According to the estimation, nearly 200 prosthetic joint infections could occur in Finland each year (the average from 1999 to 2004) after THA and TKA. Conclusions. Postdischarge surveillance had a major impact on SSI rates after major hip and knee surgery. A minority of deep incisional and organ/space SSIs would be missed, however, if postdischarge surveillance by questionnaire was not performed. According to the validation study, most SSIs reported to SIRO were true infections. Some SSIs were missed, revealing some weakness in case finding. Variation in diagnostic practices may also affect SSI rates. No differences were found in deep SSI rates or mortality between bi- and unilateral THA and TKA. However, patient materials between these two groups differed. Bilateral operations require specific attention paid to their antimicrobial prophylaxis as well as to data management in the surveillance database. The true disease burden of prosthetic joint infections may be heavier than the rates from national nosocomial surveillance systems usually suggest.
Resumo:
Reticulated porous Ti3AlC2 ceramic, a member of the MAX-phase family (Mn+1AXn phases, where M is an early transition metal, A is an A-group element, and X is carbon and/or nitrogen), was prepared from the highly dispersed aqueous suspension by a replica template method. Through a cathodic electrogeneration method, nanocrystalline catalytic CeO2 coatings were deposited on the conductive porous Ti 3AlC2 supports. By adjusting the pH value and cathodic deposition current, coatings exhibiting nanocellar, nanosheets-like, or bubble-free morphologies can be obtained. This work expects to introduce a novel practically feasible material system and a catalytic coating preparation technique for gas exhaust catalyst devices.
Resumo:
Accurate characterization and reporting of organic photovoltaic (OPV) device performance remains one of the important challenges in the field. The large spread among the efficiencies of devices with the same structure reported by different groups is significantly caused by different procedures and equipment used during testing. The presented article addresses this issue by offering a new method of device testing using “suitcase sample” approach combined with outdoor testing that limits the diversity of the equipment, and a strict measurement protocol. A round robin outdoor characterization of roll-to-roll coated OPV cells and modules conducted among 46 laboratories worldwide is presented, where the samples and the testing equipment were integrated in a compact suitcase that served both as a sample transportation tool and as a holder and test equipment during testing. In addition, an internet based coordination was used via plasticphotovoltaics.org that allowed fast and efficient communication among participants and provided a controlled reporting format for the results that eased the analysis of the data. The reported deviations among the laboratories were limited to 5% when compared to the Si reference device integrated in the suitcase and were up to 8% when calculated using the local irradiance data. Therefore, this method offers a fast, cheap and efficient tool for sample sharing and testing that allows conducting outdoor measurements of OPV devices in a reproducible manner.
Resumo:
An analysis and design study using Shape Memory Alloy (SMA) wire integrated beam and its buckling shape control are reported. The dynamical system performance is analyzed with a mathematical set-up involving nonlocal and rate sensitive kinetics of phase transformation in the SMA wire. A standard phenomenological constitutive model reported by Brinson (1993) is modified by considering certain consistency conditions in the material property tensors and by eliminating spurious singularity. Considering the inhomogeneity effects, a finite element model of the SMA wire is developed. Simulations are carried out to study the buckling shape control of a beam integrated with SMA wire.