993 resultados para OPTICAL-DETECTION
Resumo:
Sensing systems in living bodies offer a large variety of possible different configurations and philosophies able to be emulated in artificial sensing systems. Motion detection is one of the areas where different animals adopt different solutions and, in most of the cases, these solutions reflect a very sophisticated form. One of them, the mammalian visual system, presents several advantages with respect to the artificial ones. The main objective of this paper is to present a system, based on this biological structure, able to detect motion, its sense and its characteristics. The configuration adopted responds to the internal structure of the mammalian retina, where just five types of cells arranged in five layers are able to differentiate a large number of characteristics of the image impinging onto it. Its main advantage is that the detection of these properties is based purely on its hardware. A simple unit, based in a previous optical logic cell employed in optical computing, is the basis for emulating the different behaviors of the biological neurons. No software is present and, in this way, no possible interference from outside affects to the final behavior. This type of structure is able to work, once the internal configuration is implemented, without any further attention. Different possibilities are present in the architecture to be presented: detection of motion, of its direction and intensity. Moreover, some other characteristics, as symmetry may be obtained.
Resumo:
The field of optical label free biosensors has become a topic of interest during past years, with devices based on the detection of angular or wavelength shift of optical modes [1]. Common parameters to characterize their performance are the Limit of Detection (LOD, defined as the minimum change of refractive index upon the sensing surface that the device is able to detect, and also BioLOD, which represents the minimum amount of target analyte accurately resolved by the system; with units of concentration (common un its are p pm, ng/ml, or nM). LOD gives a first value to compare different biosensors, and is obtained both theoretically (using photonic calculation tools), and experimentally,covering the sensing area with fluids of different refractive indexes.
Resumo:
Recent advances in coherent optical receivers is reviewed. Digital-Signal-Processing (DSP) based phase and polarization management techniques make coherent detection robust and feasible. With coherent detection, the complex field of the received optical signal is fully recovered, allowing compensation of linear and nonlinear optical impairments including chromatic dispersion (CD) and polarization-mode dispersion (PMD) using digital filters. Coherent detection and advanced optical modulation formats have become a key ingredient to the design of modern dense wavelength-division multiplexed (DWDM) optical broadband networks. In this paper, firstly we present the different subsystems of a digital coherent optical receiver, and secondly, we will compare the performance of some multi-level and multi-dimensional modulation formats in some physical impairments and in high spectral-efficiency (SE) and high-capacity DWDM transmissions, simulating the DSP with Matlab and the optical network performance with OptiSystem software.
Resumo:
The analysis of the interference modes has an increasing application, especially in the field of optical biosensors. In this type of sensors, the displacement Δν of the interference modes of the transduction signal is observed when a particular biological agent is placed over the biosensor. In order to measure this displacement, the position of a maximum (or a minimum) of the signal must be detected before and after placing the agent over the sensor. A parameter of great importance for this kind of sensors is the period Pν of the signal, which is inversely proportional to the optical thickness h0 of the sensor in the absence of the biological agent. The increase of this period improves the sensitivity of the sensor but it worsens the detection of the maximum. In this paper, authors analyze the propagation of uncertainties in these sensors when using least squares techniques for the detection of the maxima (or minima) of the signal. Techniques described in supplement 2 of the ISO-GUM Guide are used. The result of the analysis allows a metrological educated answer to the question of which is the optimal period Pν of the signal. El análisis del comportamiento de los modos de interferencia tiene una aplicación cada vez más amplia, especialmente en el campo de los biosensores ópticos. En este tipo de sensores se observa el desplazamiento Δν de los modos de interferencia de la señal de transducción al reconocer un de-terminado agente biológico. Para medir ese desplazamiento se debe detectar la posición de un máximo o mínimo de la señal antes y después de dicho desplazamiento. En este tipo de biosensores un parámetro de gran importancia es el periodo Pν de la señal el cual es inversamente proporcional al espesor óptico h0 del sensor en ausencia de agente biológico. El aumento de dicho periodo mejora la sensibilidad del sensor pero parece dificultar la detección del mínimo o máximo. Por tanto, su efecto sobre la incertidumbre del resultado de la medida presenta dos efectos contrapuestos: la mejora de la sensibilidad frente a la dificultad creciente en la detección del mínimo ó máximo. En este trabajo, los autores analizan la propagación de incertidumbres en estos sensores utilizando herramientas de ajuste por MM.CC. para la detección de los mínimos o máximos de la señal y técnicas de propagación de incertidumbres descritas en el suplemento 2 de la Guía ISO-GUM. El resultado del análisis permite dar una respuesta, justificada desde el punto de vista metrológico, de en que condiciones es conveniente o no aumentar el periodo Pν de la señal.
Resumo:
Adjusting N fertilizer application to crop requirements is a key issue to improve fertilizer efficiency, reducing unnecessary input costs to farmers and N environmental impact. Among the multiple soil and crop tests developed, optical sensors that detect crop N nutritional status may have a large potential to adjust N fertilizer recommendation (Samborski et al. 2009). Optical readings are rapid to take and non-destructive, they can be efficiently processed and combined to obtain indexes or indicators of crop status. However, other physiological stress conditions may interfere with the readings and detection of the best crop nutritional status indicators is not always and easy task. Comparison of different equipments and technologies might help to identify strengths and weakness of the application of optical sensors for N fertilizer recommendation. The aim of this study was to evaluate the potential of various ground-level optical sensors and narrow-band indices obtained from airborne hyperspectral images as tools for maize N fertilizer recommendations. Specific objectives were i) to determine which indices could detect differences in maize plants treated with different N fertilizer rates, and ii) to evaluate its ability to identify N-responsive from non-responsive sites.
Resumo:
Synthetic Aperture Radar’s (SAR) are systems designed in the early 50’s that are capable of obtaining images of the ground using electromagnetic signals. Thus, its activity is not interrupted by adverse meteorological conditions or during the night, as it occurs in optical systems. The name of the system comes from the creation of a synthetic aperture, larger than the real one, by moving the platform that carries the radar (typically a plane or a satellite). It provides the same resolution as a static radar equipped with a larger antenna. As it moves, the radar keeps emitting pulses every 1/PRF seconds —the PRF is the pulse repetition frequency—, whose echoes are stored and processed to obtain the image of the ground. To carry out this process, the algorithm needs to make the assumption that the targets in the illuminated scene are not moving. If that is the case, the algorithm is able to extract a focused image from the signal. However, if the targets are moving, they get unfocused and/or shifted from their position in the final image. There are applications in which it is especially useful to have information about moving targets (military, rescue tasks,studyoftheflowsofwater,surveillanceofmaritimeroutes...).Thisfeatureiscalled Ground Moving Target Indicator (GMTI). That is why the study and the development of techniques capable of detecting these targets and placing them correctly in the scene is convenient. In this document, some of the principal GMTI algorithms used in SAR systems are detailed. A simulator has been created to test the features of each implemented algorithm on a general situation with moving targets. Finally Monte Carlo tests have been performed, allowing us to extract conclusions and statistics of each algorithm.
Resumo:
El objetivo de esta tesis es el desarrollo y caracterización de biosensores ópticos sin marcado basados en celdas sensoras biofotónicas (BICELLs). Éstas son un nuevo concepto de biosensor desarrollado por el grupo de investigación y consiste en la combinación de técnicas de interrogación vertical, junto a estructuras fotónicas producidas usando métodos de micro- y nanofabricación. Varias conclusiones son extraídas de este trabajo. La primera, que se ha definido una BICELL estándar basada en interferómetros Fabry-Perot (FP). Se ha demostrado su capacidad para la comparación de rendimiento entre BICELLs estructuradas y para la realización de inmunoensayos de bajo coste. Se han estudiado diferentes técnicas de fabricación disponibles para la producción de BICELLs. Se determinó que la litografía de contacto a nivel de oblea produce estructuras de bajo coste, reproducibles y de alta calidad. La resolución alcanzada ha sido de 700 nm. El estudio de la respuesta a inmunoensayos de las BICELLs producidas se ha desarrollado en este trabajo. Se estudió la influencia de BICELLs basadas en diferentes geometrías y tamaños. De aquí resulta un nuevo enfoque para predecir el comportamiento de respuesta para la detección biológica de cualquier biosensor óptico estructurado, relacionando su superficie efectiva y su sensibilidad óptica. También se demostró una técnica novedosa y de bajo coste para la caracterización experimental de la sensibilidad óptica, basada en el depósito de películas ultradelgadas. Finalmente, se ha demostrado el uso de BICELLs desarrolladas en esta tesis, en la detección de aplicaciones reales, tales como hormonas, virus y proteínas. ABSTRACT The objective of this thesis is the development and characterization of optical label-free biosensors based on Bio-Photonic sensing Cells (BICELLs). BICELL is a novel biosensor concept developed by the research group, and it consists of a combination of vertical interrogation optical techniques and photonic structures produced by using micro- and nano-fabrication methods. Several main conclusions are extracted from this work. Firstly, a standard BICELL is defined based on FP interferometers, which demonstrated its capacity for accomplishing performance comparisons among different structured BICELLs, as well as to achieve low-cost immunoassays. Different available fabrication techniques were studied for BICELL manufacturing. It is found that contact lithography at wafer scale produce cost-effective, reproducible and high quality structures. The resolution achieved was 700 nm. Study on the response of developed BICELLs to immunoassays is performed within this work. It is therefore studied the influence of BICELLs based on different geometries and sizes in the immunoassay, which resulted in a new approach to predict the biosensing behaviour of any structured optical biosensor relating to its effective surface and optical sensitivity. Also, it is demonstrated a novel and low-cost characterization technique of the experimental optical sensitivity, based on ultrathin-film deposition. Finally, it is also demonstrated the capability of using the developed BICELLs in this thesis for real applications detection of hormones, virus and proteins.
Resumo:
Many elementary chemical and physical processes such as the breaking of a chemical bond or the vibrational motion of atoms within a molecule take place on a femtosecond (fs = 10−15 s) or picosecond (ps = 10−12 s) time scale. It is now possible to monitor these events as a function of time with temporal resolution well below 100 fs. This capability is based on the pump-probe technique where one optical pulse triggers a reaction and a second delayed optical pulse probes the changes that ensue. To illustrate this capability, the dynamics of ligand motion within a protein are presented. Moving beyond casual observation of a reaction to active control of its outcome requires additional experimental and theoretical effort. To illustrate the concept of control, the effect of optical pulse duration on the vibrational dynamics of a tri-atomic molecule are discussed. The experimental and theoretical resources currently available are poised to make the dream of reaction control a reality for certain molecular systems.
Resumo:
The practical application of optical antennas in detection devices strongly depends on its ability to produce an acceptable signal-to-noise ratio for the given task. It is known that, due to the intrinsic problems arising from its sub-wavelength dimensions, optical antennas produce very small signals. The quality of these signals depends on the involved transduction mechanism. The contribution of different types of noise should be adapted to the transducer and to the signal extraction regime. Once noise is evaluated and measured, the specific detectivity, D*, becomes the parameter of interest when comparing the performance of antenna coupled devices with other detectors. However, this parameter involves some magnitudes that can be defined in several ways for optical antennas. In this contribution we are interested in the evaluation and comparison of D_ values for several bolometric optical antennas working in the infrared and involving two materials. At the same time, some material and geometrical parameters involved in the definition of noise and detectivity will be discussed to analyze the suitability of D_ to properly account for the performance of optical antennas.
Resumo:
Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) has been employed to carry out the determination of both major anions and cations in water samples. The anion quantification has been performed by means of a new automatic accessory. In this device chloride has been determined by continuously adding a silver nitrate solution. As a result solid silver chloride particles are formed and retained on a nylon filter inserted in the line. The emission intensity is read at a silver characteristic wavelength. By plotting the drop in silver signal versus the chloride concentration, a straight line is obtained. As regards bicarbonate, this anion has been on-line transformed into carbon dioxide with the help of a 2.0 mol L−1 nitric acid stream. Carbon signal is linearly related with bicarbonate concentration. Finally, information about sulfate concentration has been achieved by means of the measurement of sulfur emission intensity. All the steps have been simultaneously and automatically performed. With this setup detection limits have been 1.0, 0.4 and 0.09 mg L−1 for chloride, bicarbonate and sulfate, respectively. Furthermore, it affords good precision with RSD below 6 %. Cation (Ca, Mg, Na and K) concentration, in turn, has been obtained by simultaneously reading the emission intensity at characteristic wavelengths. The obtained limits of detection have been 8 × 10−3, 2 × 10−3, 8 × 10−4 and 10−2 mg L−1 for sodium, potassium, magnesium and calcium, respectively. As regards sample throughput, about 30 samples h−1 can be analysed. Validation results have revealed that the obtained concentrations for these anions are not significantly different as compared to the data provided by conventional methods. Finally, by considering the data for anions and cations, precise ion balances have been obtained for well and mineral water samples.
Resumo:
Object tracking with subpixel accuracy is of fundamental importance in many fields since it provides optimal performance at relatively low cost. Although there are many theoretical proposals that lead to resolution increments of several orders of magnitude, in practice this resolution is limited by the imaging systems. In this paper we propose and demonstrate through simple numerical models a realistic limit for subpixel accuracy. The final result is that maximum achievable resolution enhancement is connected with the dynamic range of the image, i.e., the detection limit is 1/2∧(nr.bits). The results here presented may aid in proper design of superresolution experiments in microscopy, surveillance, defense, and other fields.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06
Resumo:
It is shown that a linear superposition of two macroscopically distinguishable optical coherent states can be generated using a single photon source and simple all-optical operations. Weak squeezing on a single photon, beam mixing with an auxiliary coherent state, and photon detecting with imperfect threshold detectors are enough to generate a coherent state superposition in a free propagating optical field with a large coherent amplitude (alpha>2) and high fidelity (F>0.99). In contrast to all previous schemes to generate such a state, our scheme does not need photon number resolving measurements nor Kerr-type nonlinear interactions. Furthermore, it is robust to detection inefficiency and exhibits some resilience to photon production inefficiency.
Resumo:
Optical coherence tomography (OCT) is an emerging coherence-domain technique capable of in vivo imaging of sub-surface structures at millimeter-scale depth. Its steady progress over the last decade has been galvanized by a breakthrough detection concept, termed spectral-domain OCT, which has resulted in a dramatic improvement of the OCT signal-to-noise ratio of 150 times demonstrated for weakly scattering objects at video-frame-rates. As we have realized, however, an important OCT sub-system remains sub-optimal: the sample arm traditionally operates serially, i.e. in flying-spot mode. To realize the full-field image acquisition, a Fourier holography system illuminated with a swept-source is employed instead of a Michelson interferometer commonly used in OCT. The proposed technique, termed Fourier-domain OCT, offers a new leap in signal-to-noise ratio improvement, as compared to flying-spot OCT systems, and represents the main thrust of this paper. Fourier-domain OCT is described, and its basic theoretical aspects, including the reconstruction algorithm, are discussed. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Extraction and reconstruction of rectal wall structures from an ultrasound image is helpful for surgeons in rectal clinical diagnosis and 3-D reconstruction of rectal structures from ultrasound images. The primary task is to extract the boundary of the muscular layers on the rectal wall. However, due to the low SNR from ultrasound imaging and the thin muscular layer structure of the rectum, this boundary detection task remains a challenge. An active contour model is an effective high-level model, which has been used successfully to aid the tasks of object representation and recognition in many image-processing applications. We present a novel multigradient field active contour algorithm with an extended ability for multiple-object detection, which overcomes some limitations of ordinary active contour models—"snakes." The core part in the algorithm is the proposal of multigradient vector fields, which are used to replace image forces in kinetic function for alternative constraints on the deformation of active contour, thereby partially solving the initialization limitation of active contour for rectal wall boundary detection. An adaptive expanding force is also added to the model to help the active contour go through the homogenous region in the image. The efficacy of the model is explained and tested on the boundary detection of a ring-shaped image, a synthetic image, and an ultrasound image. The experimental results show that the proposed multigradient field-active contour is feasible for multilayer boundary detection of rectal wall