931 resultados para Nonblind receiver


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diagnosis of autoimmune hepatitis (AIH) may be challenging. However, early diagnosis is important because immunosuppression is life-saving. Diagnostic criteria of the International Autoimmune Hepatitis Group (IAIHG) were complex and purely meant for scientific purposes. This study of the IAIHG aims to define simplified diagnostic criteria for routine clinical practice. Candidate criteria included sex, age, autoantibodies, immunoglobutins, absence of viral hepatitis, and histology. The training set included 250 AIH patients and 193 controls from 11 centers worldwide. Scores were built from variables showing predictive ability in univariate analysis. Diagnostic value of each score was assessed by the area under the receiver operating characteristic (ROC) curve. The best score was validated using data of an additional 109 AIH patients and 284 controls. This score included autoantibodies, immunoglobulin G, histology, and exclusion of viral hepatitis. The area under the curve for prediction of AIH was 0.946 in the training set and 0.91 in the validation set. Based on the ROC curves, two cutoff points were chosen. The score was found to have 88% sensitivity and 97% specificity (cutoff >= 6) and 81% sensitivity and 99% specificity (cutoff 2:7) in the validation set. Conclusion: A reliable diagnosis of AIH can be made using a very simple diagnostic score. We propose the diagnosis of probable AIH at a cutoff point greater than 6 points and definite AIH 7 points or higher.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the abilities of scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) and variable corneal compensation (VCC) modes for detection of retinal nerve fiber layer (RNFL) loss in eyes with band atrophy (BA) of the optic nerve. DESIGN. Cross-sectional study. METHODS: Thirty-seven eyes from 37 patients with BA and temporal visual field defect from chiasmal compression and 40 eyes from 40 healthy subjects were studied. Subjects underwent standard automated perimetry and RNFL measurements using an SLP device equipped with VCC and ECC. Receiver operating characteristic (ROC) curves were calculated for each parameter. Pearson correlation coefficients were obtained to evaluate the relationship between RNFL thickness parameters and severity of visual field loss, as assessed by the temporal mean defect. RESULTS: All RNFL thickness parameters were significantly lower in eyes with BA compared with normal eyes with both compensation modes. However, no statistically significant differences were observed in the areas under the ROC curves for the different parameters between GDx VCC and ECC (Carl Zeiss Meditec, Inc, Dublin, California, USA). Structure-function relationships also were similar for both compensation modes. CONCLUSIONS: No significant differences were found between the diagnostic accuracy of GDx ECC and that of VCC for detection of BA of the optic nerve. The use of GDx ECC does not seem to provide a better evaluation of RNFL loss on the temporal and nasal sectors of the peripapillary retina in subjects with BA of the optic nerve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was designed to examine the use of the QuantiFERON-TB Gold assay as an aid in the diagnosis of active pulmonary tuberculosis (TB) in Brazilian patients. Using the receiver operating characteristic curve, the cutoff was adjusted to >= 0.20 IU/ml. The sensitivity increased to 86%, with 100% specificity. All TB patients with negative sputum smear microscopy and negative culture results were positive using this test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The purpose of this study was to evaluate the diagnostic usefulness of ulnar nerve sonography in leprosy neuropathy with electrophysiologic correlation. Methods. Twenty-one consecutive patients with leprosy (12 men and 9 women; mean age +/- SD, 47.7 +/- 17.2 years) and 20 control participants (14 men and 6 women; mean age, 46.5 +/- 16.2 years) were evaluated with sonography. Leprosy diagnosis was established on the basis of clinical, bacteriologic, and histopathologic criteria. The reference standard for ulnar neuropathy in this study was clinical symptoms in patients with proven leprosy The sonographic cross-sectional areas (CSAs) of the ulnar nerve in 3 different regions were obtained. Statistical analyses included Student t tests and receiver operating characteristic curve analysis. Results. The CSAs of the ulnar nerve were significantly larger in the leprosy group than the control group for all regions (P < .01). Sonographic abnormalities in leprosy nerves included focal thickening (90.5%), hypoechoic areas (81%), loss of the fascicular pattern (33.3%), and focal hyperechoic areas (4.7%). Receiver operating characteristic curve analysis showed that a maximum CSA cutoff value of 9.8 mm(2) was the best discriminator (sensitivity, 0.91; specificity, 0.90). Three patients with normal electrophysiologic findings had abnormal sonographic findings. Two patients had normal sonographic findings, of which 1 had abnormal electrophysiologic findings, and the other refused electrophysiologic testing. Conclusions. Sonography and electrophysiology were complementary for identifying ulnar nerve neuropathy in patients with leprosy, with clinical symptoms as the reference standard. This reinforces the role of sonography in the investigation of leprosy ulnar neuropathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Hypertension, a risk factor for cardiovascular diseases, and obesity are becoming a health problem in many developed and developing countries, as Brazil. Although hypertension and obesity are both closely associated, there is no universal anthropometric marker of this association. This is probably due to distinct population characteristics, and in the case of Brazil, the highly heterogeneous population. We evaluated which anthropometric measurement closely relates to high blood pressure in a sample of Brazilian factory workers. METHODS A cross-sectional study was designed. In this study, multiple logistic regression and receiver operating characteristics analysis were performed in order to obtain the precise relevance of each anthropometric measurement as a blood pressure marker. Nine hundred and thirteen men, 36 +/- 8 years-old, were submitted to a standardized questionnaire of demographic and risk factors knowledge, anthropometric and conventional blood pressure measurements were taken, and blood sample evaluations of glucose, total cholesterol, LDL-Cholesterol, and triglycerides were performed. RESULTS Overweightness or obesity was identified in 64, 11.1% were smokers and hypertension was detected in 29.2% of the participants. A linear correlation was significant (P < 0.001) between both the systolic and diastolic blood pressure and all anthropometric measurements, except for the systolic blood pressure and waist-to-hip ratio. Waist circumference (WC) was the only independent anthropometric measurement related to hypertension. Hypertensive patients presented all anthropometric measurements larger than normotensives. CONCLUSIONS Age and WC were the only independent predictors of hypertension, indicating that this simple measurement may be useful as a marker of hypertension in the Brazilian male, younger adult population. Am J Hypertens 2009; 22:980-984 (C) 2009 American Journal of Hypertension, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Methods: We assessed the outcome of 56 patients with Chagas` cardiomyopathy ([31 men]; mean age of 55 years; mean left ventricular ejection fraction [LVEF] 42%) presenting with either sustained ventricular tachycardia (VT) or nonsustained VT (NSVT), before therapy with implantable cardioverter-defibrillator was available at our center. Results: Over a mean follow-up of 38 +/- 16 months (range, 1-61 months), 16 patients (29%) died, 11 due to sudden cardiac death (SCD), and five from progressive heart failure. Survivors and nonsurvivors had comparable baseline characteristics, except for a lower LVEF (46 +/- 7% vs 31 +/- 9%, P < 0.001) and a higher New York Heart Association class (P = 0.003) in those who died during follow-up. Receiver-operator characteristic curve analysis showed that an LVEF cutoff value of 38% had the best accuracy for predicting all-cause mortality and an LVEF cutoff value of 40% had the best accuracy for prediction of SCD. Using the multivariate Cox regression analysis, LVEF < 40% was the only predictor of all-cause mortality (hazard ratio [HR] 12.22, 95% confidence interval [CI] 3.46-43.17, P = 0.0001) and SCD (HR 6.58, 95% CI 1.74-24.88, P = 0.005). Conclusions: Patients with Chagas` cardiomyopathy presenting with either sustained VT or NSVT run a major risk for mortality when had concomitant severe or even moderate LV systolic dysfunction. (PACE 2011; 54-62).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To demonstrate that the evaluation of erythrocyte dysmorphism by light microscopy with lowering of the condenser lens (LMLC) is useful to identify patients with a haematuria of glomerular or non-glomerular origin. Methods: A comparative double-blind study between phase contrast microscopy (PCM) and LMLC is reported to evaluate the efficacy of these techniques. Urine samples of 39 patients followed up for 9 months were analyzed, and classified as glomerular and non-glomerular haematuria. The different microscopic techniques were compared using receiver-operator curve (ROC) analysis and area under curve (AUC). Reproducibility was assessed by coefficient of variation (CV). Results: Specific cut-offs were set for each method according to their best rate of specificity and sensitivity as follows: 30% for phase contrast microscopy and 40% for standard LMLC, reaching in the first method the rate of 95% and 100% of sensitivity and specificity, respectively, and in the second method the rate of 90% and 100% of sensitivity and specificity, respectively. In ROC analysis, AUC for PCM was 0.99 and AUC for LMLC was 0.96. The CV was very similar in glomerular haematuria group for PCM (35%) and LMLC (35.3%). Conclusion: LMLC proved to be effective in contributing to the direction of investigation of haematuria, toward the nephrological or urological side. This method can substitute PCM when this equipment is not available.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context Novel therapies have improved the remission rate in chronic inflammatory disorders including juvenile idiopathic arthritis (JIA). Therefore, strategies of tapering therapy and reliable parameters for detecting subclinical inflammation have now become challenging questions. Objectives To analyze whether longer methotrexate treatment during remission of JIA prevents flares after withdrawal of medication and whether specific biomarkers identify patients at risk for flares. Design, Setting, and Patients Prospective, open, multicenter, medication-withdrawal randomized clinical trial including 364 patients (median age, 11.0 years) with JIA recruited in 61 centers from 29 countries between February 2005 and June 2006. Patients were included at first confirmation of clinical remission while continuing medication. At the time of therapy withdrawal, levels of the phagocyte activation marker myeloid-related proteins 8 and 14 heterocomplex (MRP8/14) were determined. Intervention Patients were randomly assigned to continue with methotrexate therapy for either 6 months (group 1 [n = 183]) or 12 months (group 2 [n = 181]) after induction of disease remission. Main Outcome Measures Primary outcome was relapse rate in the 2 treatment groups; secondary outcome was time to relapse. In a prespecified cohort analysis, the prognostic accuracy of MRP8/14 concentrations for the risk of flares was assessed. Results Intention-to-treat analysis of the primary outcome revealed relapse within 24 months after the inclusion into the study in 98 of 183 patients (relapse rate, 56.7%) in group 1 and 94 of 181 (55.6%) in group 2. The odds ratio for group 1 vs group 2 was 1.02 (95% CI, 0.82-1.27; P=.86). The median relapse-free interval after inclusion was 21.0 months in group 1 and 23.0 months in group 2. The hazard ratio for group 1 vs group 2 was 1.07 (95% CI, 0.82-1.41; P=.61). Median follow-up duration after inclusion was 34.2 and 34.3 months in groups 1 and 2, respectively. Levels of MRP8/14 during remission were significantly higher in patients who subsequently developed flares (median, 715 [IQR, 320-1110] ng/mL) compared with patients maintaining stable remission (400 [IQR, 220-800] ng/mL; P=.003). Low MRP8/14 levels indicated a low risk of flares within the next 3 months following the biomarker test (area under the receiver operating characteristic curve, 0.76; 95% CI, 0.62-0.90). Conclusions In patients with JIA in remission, a 12-month vs 6-month withdrawal of methotrexate did not reduce the relapse rate. Higher MRP8/14 concentrations were associated with risk of relapse after discontinuing methotrexate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To investigate the accuracy of the Brazilian version of the Addenbrooke Cognitive Examination-revised (ACE-R) in the diagnosis of mild Alzheimer disease (AD). Background: The ACE-R is an accurate and brief cognitive battery for the detection of mild dementia, especially for the discrimination between AD and frontotemporal dementia. Methods: The battery was administered to 31 patients with mild AD and 62 age-matched and education-matched cognitively healthy controls. Both groups were selected using the Dementia Rating Scale and were submitted to the ACE-R. Depression was ruled out in both groups by the Cornell Scale for Depression in Dementia. The performance of patients and controls in the ACE-R was compared and receiver operator characteristic curve analysis was undertaken to ascertain the accuracy of the instrument for the diagnosis of mild AD. Results: The mean scores at the ACE-R were 63.10 +/- 10.22 points for patients with AD and 83.63 +/- 7.90 points for controls. The cut-off score < 78 yielded high diagnostic accuracy (receiver operator characteristic area under the curve = 0.947), with 100% sensitivity, 82.26% specificity, 73.8% positive predictive value, and 100% negative predictive value. Conclusions: The Brazilian version of the ACE-R displayed high diagnostic accuracy for the identification of mild AD in the studied sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Acute kidney injury (AKI) is a frequent complication in hospitalized patients, especially in those in intensive care units (ICU). The RIFLE classification might be a valid prognostic factor for critically ill cancer patients. The present study aims to evaluate the discriminatory capacity of RIFLE versus other general prognostic scores in predicting hospital mortality in critically ill cancer patients. Methods: This is a single-center study conducted in a cancer-specialized ICU in Brazil. All of the 288 patients hospitalized from May 2006 to June 2008 were included. RIFLE classification, APACHE II, SOFA, and SAPS II scores were calculated and the area under receiver operating characteristic (AROC) curves and logistic multiple regression were performed using hospital mortality as the outcome. Results: AKI, defined by RIFLE criteria, was observed in 156 (54.2%) patients. The distribution of patients with any degree of AKI was: risk, n = 96 (33.3%); injury, n = 30 (10.4%), and failure, n = 30 (10.4%). Mortality was 13.6% for non-AKI patients, 49% for RIFLE `R` patients, 62.3% for RIFLE `I` patients, and 86.8% for RIFLE `F` patients (p = 0.0006). Logistic regression analysis showed that RIFLE criteria, APACHE II, SOFA, and SAPS II were independent factors for mortality in this population. The discrimination of RIFLE was good (AROC 0.801, 95% CI 0.748-0.854) but inferior compared to those of APACHE II (AROC 0.940, 95% CI 0.915-0.966), SOFA (AROC 0.910, 95% CI 0.876-0.943), and SAPS II (AROC 0.869, 95% CI 0.827-0.912). Conclusion: AKI is a frequent complication in ICU patients with cancer. RIFLE was inferior to commonly used prognostic scores for predicting mortality in this cohort of patients. Copyright (C) 2011 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To establish body mass index (BMI) norms for standard figural stimuli using a large Caucasian population-based sample. In addition, we sought to determine the effectiveness of the figural stimuli to identify individuals as obese or thin. DESIGN: All Caucasian twins born in Virginia between 1915 and 1971 were identified by public birth record. In addition, 3347 individual twins responded to a letter published in the newsletter of the American Association of Retired Persons (AARP). All adult twins (aged 18 and over) from both of these sources and their family members were mailed a 16 page 'Health and Lifestyle' questionnaire. SUBJECTS: BMI and silhouette data were available on 16 728 females and 11 366 males ranging in age from 18- 100. MEASUREMENTS: Self-report information on height-weight, current body size, desired body size and a discrepancy score using standard figural stimuli. RESULTS: Gender- and age-specific norms are presented linking BMI to each of the figural stimuli. Additional norms for desired body size and discrepancy scores are also presented. Receiver operating curves (ROC) indicate that the figural stimuli are effective in classifying individuals as obese or thin. CONCLUSIONS: With the establishment of these norms, the silhouettes used in standard body image assessment can now be linked to BMI. Differences were observed between women and men in terms of desired body size and discrepancy scores, with women preferring smaller sizes. The figural stimuli are a robust technique for classifying individuals as obese or thin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rectangular piezoceramic transducers are widely used in ultrasonic evaluation and health monitoring techniques and structural vibration control applications. In this paper the flexural waves excited by rectangular transducers adhesively attached to isotropic plates are investigated. In view of the difficulties in developing accurate analytical models describing the transfer characteristics of the transducer due to the complex electromechanical transduction processes and transducer-structure interactions involved, a combined theoretical-experimental approach is developed. A multiple integral transform method is used to describe the propagation behaviour of the waves in the plates, while a heterodyne Doppler laser vibrometer is employed as a non-contact receiver device. This combined theoretical-experimental approach enables the efficient characterization of the electromechanical transfer properties of the piezoelectric transducer which is essential for the development of optimized non-destructive evaluation systems. The results show that the assumption of a uniform contact pressure distribution between the transducer and the plate can accurately predict the frequency spectrum and time domain response signals of the propagating waves along the main axes of the rectangular transmitter element.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The acousto-ultrasonic (AU) input-output characteristics for contact-type transmitting and receiving transducers coupled to composite laminated plates are considered in this paper. Combining a multiple integral transform method, an ordinary discrete layer theory for the laminates and some simplifying assumptions for the electro-mechanical transduction behaviour of the transducers, an analytical solution is developed which can deal with all the wave processes involved in the AU measurement system, i.e, wave generation, wave propagation and wave reception. The spectral response of the normal contact pressure sensed by the receiving transducer due to an arbitrary input pulse excited by the transmitting transducer is obtained. To validate the new analytical-numerical spectral technique in the low-frequency regime, the results are compared with Mindlin plate theory solutions. Based on the analytical results, numerical calculations are carried out to investigate the influence of various external parameters such as frequency content of the input pulse, transmitter/receiver spacing and transducer aperture on the output of the measurement system. The results show that the presented analytical-numerical procedure is an effective tool for understanding the input-output characteristics of the AU technique for laminated plates. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The Edinburgh Postnatal Depression Scale (EPDS) has been validated and used extensively in screening for depression in new mothers, both in English speaking and non-English speaking communities. While some studies have reported the use of the EPDS with Fathers, none have validated it for this group, and thus the appropriate cut-off score for screening for depression or anxiety caseness for this population is not known. Method: Couples were recruited antenatally and interviewed at six weeks postpartum. EPDS scores and distress caseness (depression or anxiety disorders) for 208 fathers and 230 mothers were determined using the Diagnostic Interview Schedule. Results: Analyses of the EPDS for fathers using distress caseness (depression or anxiety disorders) as the criterion shows that a cut-off of 5/6 has optimum receiver operating characteristics. Furthermore acceptable reliability (split-half and internal consistency) and validity (concurrent) coefficients were obtained. For mothers the optimum cut-off screening value to detect distress caseness was 7/8. Item analysis revealed that fathers endorsed seven of the ten items at lower rates to mothers, with the most significant being that referring to crying. Conclusions: The EPDS is a reliable and valid measure of mood in fathers. Screening for depression or anxiety disorders in fathers requires a two point lower cut-off than screening for depression or anxiety in mothers, and we recommend this cut-off to he 5/6. (C) 2001 Elsevier Science B.V. All rights reserved.