976 resultados para NEEDLE-BIOPSY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Langerhans' cell histiocytosis (LCH) is a rare and enigmatic clonal disorder that affects mainly children. It is characterized by single or multiple granulomatous mass lesions composed of cells with the Langerhans' cell phenotype. Clinical presentation and behavior are heterogeneous and can range from a solitary lytic bone lesion (i.e., eosinophilic granuloma) with a favorable course to a fatal disseminated leukaemia-like form, with a wide spectrum of intermediate clinical presentations between these two extremes. Although LCH typically involves the bone, lesions can be found in almost all organs. We are reporting the case of a multisystem LCH in a 47-year-old patient who presented with a panhypopituitarism and diabetes insipidus, and who, 5 years later, developed mandibular, mastoid and femoral lesions. The final diagnosis of LCH was made on mandibular biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Etude de la valeur pronostique de la biopsie du ganglion sentinelle dans une étude prospective monocentrique de 327 patients atteints de mélanome malin But II s'agit de confirmer la validité de la biopsie du ganglion sentinelle, d'en définir la morbidité, d'investiguer les facteurs prédictifs pour le statut du ganglion sentinelle ainsi que de déterminer les facteurs pronostiques pour la survie sans récidive et la survie spécifique liée à la maladie. Matériel et méthode D'octobre 1997 à décembre 2004, 327 patients consécutifs présentant un mélanome cutané primaire des membres, du tronc et de la tête, sans adénopathie clinique ni métastase à distance ont été inclus. La biopsie du ganglion sentinelle a été réalisée selon la triple technique (lymphoscintigraphie, colorant bleu vital et sonde de détection gamma). Les paramètres et la survie ont été évalués par différentes analyses de régression logistique multiple selon Cox et la survie évaluée selon Kaplan Meier. Résultats Vingt-trois pour cent des patients présentaient au moins un ganglion sentinelle métastatique, ce qui était associé de façon significative à l'épaisseur selon Breslow (p<0.001). Le taux de succès de la biopsie du ganglion sentinelle était de 99.1% et sa morbidité de 7.6%. Avec une durée médiane de suivi de 33 mois, la survie sans récidive à 5 ans était de 43% pour les patients avec un ganglion sentinelle positif et de 83.5% pour ceux avec un ganglion sentinelle négatif. La survie spécifique liée à la maladie à 5 ans était de 49% pour les patients avec un ganglion sentinelle positif et de 87.4% pour ceux avec un ganglion sentinelle négatif. Le taux de faux négatif de la biopsie du ganglion sentinelle était de 8.6%. L'analyse multivariée a démontré que la survie sans récidive était significativement péjorée par :l'épaisseur selon Breslow (RR=5.6, p<0.001), un ganglion sentinelle positif (RR=5.0, p<0.001), et le sexe masculin (RR=2.9, p=0.001). La survie spécifique liée à la maladie était significativement diminuée par : un ganglion sentinelle métastatique (RR=8.4, p<O.OOI), le sexe masculin (RR=6.1, p<0.001), l'épaisseur selon Breslow (RR=3.2, p=0.013), et la présence d'une ulcération (RR=2.6, p=0.015). Conclusion La biopsie du ganglion sentinelle est une procédure fiable avec une haute sensibilité (91.4%) et une faible morbidité (7.6%). L'épaisseur selon Breslow était le seul facteur prédictif significatif pour le statut du ganglion sentinelle. La survie sans récidive était péjorée selon un ordre décroissant par :l'épaisseur selon Breslow, un ganglion sentinelle métastatique, et le sexe masculin. De façon similaire la survie spécifique liée à la maladie était péjorée par : un ganglion sentinelle métastatique, le sexe masculin, l'épaisseur selon Breslow, et une ulcération. Ces données renforcent le statut du ganglion sentinelle en tant que puissant moyen pour évaluer le stade tumoral ainsi que le pronostic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com o objetivo de avaliar o desempenho das agulhas de calibres 14 e 12 na obtenção de "core biopsies" da mama sob controle estereotáxico, os autores compararam biópsias de lesões mamárias impalpáveis obtidas com agulhas desses calibres quanto ao tamanho dos fragmentos e freqüência dos tipos de lesões diagnosticadas. De um total de 1.009 biópsias, os autores analisaram 900 obtidas por agulhas 14 e 109 obtidas por agulhas 12, para análise da freqüência das lesões. Os tamanhos dos fragmentos foram analisados nos 700 primeiros casos para os espécimes obtidos por agulhas 14. A utilização de agulhas 12 resultou em maior tamanho dos fragmentos (p < 0,001), ausência de material insatisfatório, redução na proporção das lesões benignas não-neoplásicas (p = 0,03) e aumento na freqüência de carcinomas (p < 0,001), tanto in situ como invasivos. Tais achados podem refletir aumento da acurácia do diagnóstico, em virtude da maior quantidade de material e/ou melhor seleção radiológica das biópsias obtidas por agulhas 12, pela utilização coincidente da mamografia digital em campo limitado (estereotaxia digital).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS: The beneficial effect of nonselective beta-blockers (NSBB) has recently been questioned in patients with end-stage cirrhosis. We analysed the impact of NSBB on outcomes in severe alcoholic hepatitis (AH). METHODS: This study was based on a prospective database of patients with severe, biopsy-proven AH. Patients admitted from July, 2006 to July, 2014 were retrospectively studied. Patients were divided into two groups (with and without NSBB) and assessed for the occurrence of Acute Kidney Injury (AKI) and transplant-free mortality during a 168-day follow-up period. RESULTS: One hundred thirty-nine patients were included, the mean Maddrey score was 71 ± 34 and 86 patients (61.9%) developed AKI. Forty-eight patients (34.5%) received NSBB. The overall 168-day transplant-free mortality was 50.5% (95%CI, 41.3-60.0%). The overall 168-day cumulative incidence of AKI was 61.9% (95%CI, 53.2-69.4%). When compared, patients with NSBB had a lower heart rate (65 ± 13 vs 92 ± 12, P < 0.0001) and a lower mean arterial pressure (MAP, 78 ± 3 vs 87 ± 5, P < 0.0001). Patients with NSBB had comparable MELD scores, Maddrey scores, and medical histories. The 168-day transplant-free mortality was 56.8% (95%CI, 41.3-69.7%) in patients with NSBB and 46.7% (95%CI, 35.0-57.6%) without NSBB (P = 0.25). The 168-day cumulative incidence of AKI was 89.6% (95%CI, 74.9-95.9%) with NSBB compared to 50.4% (95%CI: 39.0-60.7) for no NSBB (P = 0.0001). The independent factors predicting AKI were a higher MELD score and the presence of NSBB. CONCLUSIONS: The use of NSBB in patients with severe AH is independently associated with a higher cumulative incidence of AKI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Severe type III laryngomalacia LM is represented by a retroflexed epiglottis that touches the posterior pharyngeal wall and obstructs the laryngeal inlet. Endoscopic epiglottopexy is advised in such cases wherein pexy sutures are passed between the epiglottis and base of tongue. Using conventional needle carriers, it is difficult to pass such sutures that go deep enough into the tongue base. Such a pexy is prone to a break down. We describe a novel technique of placing these glossoepiglottic sutures using the Lichtenberger's needle carrier. We used this technique in three patients with excellent results and report no complications. We propose to use this technique in cases of epiglottic prolapse seen in severe LM and certain hypotonic conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. Study design: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle was used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm or an XL Monoprotect® 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was systematically recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the practitioner performing the technique, and blood aspiration (either positive or negative). Results: 346 needles were used in total. 190 were standard needles (27-gauge x 35-mm needle with an internal gauge of 0.215 mm) and 156 were XL Monoprotect®. Incidence of deflection was observed in 49.1% of cases (170 needles) where 94 were standard needles and 76 XL Monoprotect®. Needle torsion ranged from 0º and 6º. Conclusions: No significant differences were recorded in terms of deflection and internal gauge, operator, patient-extraction side, the anesthetic technique involved and the number of bone contacts during the procedure

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The advent of multiparametric MRI has made it possible to change the way in which prostate biopsy is done, allowing to direct biopsies to suspicious lesions rather than randomly. The subject of this review relates to a computer-assisted strategy, the MRI/US fusion software-based targeted biopsy, and to its performance compared to the other sampling methods. Different devices with different methods to register MR images to live TRUS are currently in use to allow software-based targeted biopsy. Main clinical indications of MRI/US fusion software-based targeted biopsy are re-biopsy in men with persistent suspicious of prostate cancer after first negative standard biopsy and the follow-up of patients under active surveillance. Some studies have compared MRI/US fusion software-based targeted versus standard biopsy. In men at risk with MRI-suspicious lesion, targeted biopsy consistently detects more men with clinically significant disease as compared to standard biopsy; some studies have also shown decreased detection of insignificant disease. Only two studies directly compared MRI/US fusion software-based targeted biopsy with MRI/US fusion visual targeted biopsy, and the diagnostic ability seems to be in favor of the software approach. To date, no study comparing software-based targeted biopsy against in-bore MRI biopsy is available. The new software-based targeted approach seems to have the characteristics to be added in the standard pathway for achieving accurate risk stratification. Once reproducibility and cost-effectiveness will be verified, the actual issue will be to determine whether MRI/TRUS fusion software-based targeted biopsy represents anadd-on test or a replacement to standard TRUS biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thyroid fine-needle aspiration (FNA) cytology is a fast growing field. One of the most developing areas is represented by molecular tests applied to cytological material. Patients that could benefit the most from these tests are those that have been diagnosed as 'indeterminate' on FNA. They could be better stratified in terms of malignancy risk and thus oriented with more confidence to the appropriate management. Taking in to consideration the need to improve and keep high the yield of thyroid FNA, professionals from various fields (i.e. molecular biologists, endocrinologists, nuclear medicine physicians and radiologists) are refining and fine-tuning their diagnostic instruments. In particular, all these developments aim at increasing the negative predictive value of FNA to improve the selection of patients for diagnostic surgery. These advances involve terminology, the application of next-generation sequencing to thyroid FNA, the use of immunocyto- and histo-chemistry, the development of new sampling techniques and the increasing use of nuclear medicine as well as molecular imaging in the management of patients with a thyroid nodule. Herein, we review the recent advances in thyroid FNA cytology that could be of interest to the 'thyroid-care' community, with particular focus on the indeterminate diagnostic category.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Prostate cancer (PCa) diagnosis relies on clinical suspicion leading to systematic transrectal ultrasound-guided biopsy (TRUSGB). Multiparametric magnetic resonance imaging (mpMRI) allows for targeted biopsy of suspicious areas of the prostate instead of random 12-core biopsy. This method has been shown to be more accurate in detecting significant PCa. However, the precise spatial accuracy of cognitive targeting is unknown. METHODS: Consecutive patients undergoing mpMRI-targeted TRUSGB with cognitive registration (MRTB-COG) followed by robot-assisted radical prostatectomy were included in the present analysis. The regions of interest (ROIs) involved by the index lesion reported on mpMRI were subsequently targeted by two experienced urologists using the cognitive approach. The 27 ROIs were used as spatial reference. Mapping on radical prostatectomy specimen was used as reference to determine true-positive mpMRI findings. Per core correlation analysis was performed. RESULTS: Forty patients were included. Overall, 40 index lesions involving 137 ROIs (mean ROIs per index lesion 3.43) were identified on MRI. After correlating these findings with final pathology, 117 ROIs (85 %) were considered as true-positive lesions. A total of 102 biopsy cores directed toward such true-positive ROIs were available for final analysis. Cognitive targeted biopsy hit the target in 82 % of the cases (84/102). The only identified risk factor for missing the target was an anterior situated ROI (p = 0.01). CONCLUSION: In experienced hands, cognitive MRTB-COG allows for an accuracy of 82 % in hitting the correct target, given that it is a true-positive lesion. Anterior tumors are less likely to be successfully targeted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renal biopsy is being increasingly proposed as a diagnostic tool to characterize small renal masses (SRM). Indeed, the wide adoption of imaging in the diagnostic workup of many diseases had led to a substantial increased incidence of SRM (diameter ≤4 cm). While modern ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) techniques have high sensitivity for detecting SRM, none is able to accurately and reliably characterize them in terms of histological features. This is currently of key importance in guiding clinical decision-making in some situations, and in these cases renal biopsy should be considered. In this review, we aim to summarize the technique, diagnostic performance, and predicting factors of nondiagnostic biopsy, as well as the future perspectives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recent discussions have focused on redefining noninvasive follicular variant of papillary thyroid carcinoma (NI-FVPTC) as a neoplasm rather than a carcinoma. This study assesses the potential impact of such a reclassification on the implied risk of malignancy (ROM) for the diagnostic categories of The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC). METHODS: The study consisted of consecutive fine-needle aspiration biopsy (FNAB) cases collected between January 1, 2013 and June 30, 2014 from 5 academic institutions. Demographic information, cytology diagnoses, and surgical pathology follow-up were recorded. The ROM was calculated with and without NI-FVPTC and was presented as a range: all cases (ie, overall risk of malignancy [OROM]) versus those with surgical follow-up only. RESULTS: The FNAB cohort consisted of 6943 thyroid nodules representing 5179 women and 1409 men with an average age of 54 years (range, 9-94 years). The combined average ROM and OROM for the diagnostic categories of TBSRTC were as follows: nondiagnostic, 4.4% to 25.3%; benign, 0.9% to 9.3%; atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS), 12.1% to 31.2%; follicular neoplasm (FN), 21.8% to 33.2%; suspicious for malignancy (SM), 62.1% to 82.6%; and malignant, 75.9% to 99.1%. The impact of reclassifying NI-FVPTC on the ROM and OROM was most pronounced and statistically significant in the 3 indeterminate categories: the AUS/FLUS category had a decrease of 5.2% to 13.6%, the FN category had a decrease of 9.9% to 15.1%, and the SM category had a decrease of 17.6% to 23.4% (P < .05), whereas the benign and malignant categories had decreases of 0.3% to 3.5% and 2.5% to 3.3%, respectfully. The trend of the effect on the ROM and OROM was similar for all 5 institutions. CONCLUSIONS: The results from this multi-institutional cohort indicate that the reclassification of NI-FVPTC will have a significant impact on the ROM for the 3 indeterminate categories of TBSRTC. Cancer Cytopathol 2016;124:181-187. © 2015 American Cancer Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the BI-RADS as a predictive factor of suspicion for malignancy in breast lesions by correlating radiological with histological results and calculating the positive predictive value for categories 3, 4 and 5 in a breast cancer reference center in the city of São Paulo. Materials and Methods Retrospective, analytical and cross-sectional study including 725 patients with mammographic and/or sonographic findings classified as BI-RADS categories 3, 4 and 5 who were referred to the authors' institution to undergo percutaneous biopsy. The tests results were reviewed and the positive predictive value was calculated by means of a specific mathematical equation. Results Positive predictive values found for categories 3, 4 and 5 were respectively the following: 0.74%, 33.08% and 92.95%, for cases submitted to ultrasound-guided biopsy, and 0.00%, 14.90% and 100% for cases submitted to stereotactic biopsy. Conclusion The present study demonstrated high suspicion for malignancy in lesions classified as category 5 and low risk for category 3. As regards category 4, the need for systematic biopsies was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combining headspace (HS) sampling with a needle-trap device (NTD) to determine priority volatile organic compounds (VOCs) in water samples results in improved sensitivity and efficiency when compared to conventional static HS sampling. A 22 gauge stainless steel, 51-mm needle packed with Tenax TA and Carboxen 1000 particles is used as the NTD. Three different HS-NTD sampling methodologies are evaluated and all give limits of detection for the target VOCs in the ng L−1 range. Active (purge-and-trap) HS-NTD sampling is found to give the best sensitivity but requires exhaustive control of the sampling conditions. The use of the NTD to collect the headspace gas sample results in a combined adsorption/desorption mechanism. The testing of different temperatures for the HS thermostating reveals a greater desorption effect when the sample is allowed to diffuse, whether passively or actively, through the sorbent particles. The limits of detection obtained in the simplest sampling methodology, static HS-NTD (5 mL aqueous sample in 20 mL HS vials, thermostating at 50 °C for 30 min with agitation), are sufficiently low as to permit its application to the analysis of 18 priority VOCs in natural and waste waters. In all cases compounds were detected below regulated levels