979 resultados para Mobile Bed Flow


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Providing QoS in the context of Ad Hoc networks includes a very wide field of application from the perspective of every level of the architecture in the network.In order for simulation studies to be useful, it is very important that the simulation results match as closely as possible with the test bed results. In this Paper, we study the throughput performance (parameter QoS) in Mobile Ad Hoc Networks (MANETs) and compares emulated test bed results with simulation results from NS2 (Network Simulator). The performance of the Mobile Ad Hoc Networks is very sensitive to the number of users and the offered load. When the number of users/offered load is high then the collisions increase resulting in larger wastage of the medium and lowering overall throughput. The aim of this research is to compare the throughput of Mobile Ad Hoc Networks using three different scenarios: 97, 100 and 120 users (nodes) using simulator NS2. By analyzing the graphs in MANETs, it is concluded When the number of users o nodes is increased beyond the certain limit, throughput decreases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most of the current evacuation plans are based on static signaling, fixed monitoring infrastructure, and limited user notification and feedback mechanisms. These facts lead to lower situation awareness, in the case event of an emergency, such as blocked emergency exits, while delaying the reaction time of individuals. In this context, we introduce the E-Flow communication system, which improves the user awareness by integrating personal, mobile and fixed devices with the existing monitoring infrastructure. Our system broadens the notification and monitoring alternatives, in real time, among, safety staff, end-users and evacuation related devices, such as sensors and actuators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluid flow and fabric compaction during vacuum assisted resin infusion (VARI) of composite materials was simulated using a level set-based approach. Fluid infusion through the fiber preform was modeled using Darcy’s equations for the fluid flow through a porous media. The stress partition between the fluid and the fiber bed was included by means of Terzaghi’s effective stress theory. Tracking the fluid front during infusion was introduced by means of the level set method. The resulting partial differential equations for the fluid infusion and the evolution of flow front were discretized and solved approximately using the finite differences method with a uniform grid discretization of the spatial domain. The model results were validated against uniaxial VARI experiments through an [0]8 E-glass plain woven preform. The physical parameters of the model were also independently measured. The model results (in terms of the fabric thickness, pressure and fluid front evolution during filling) were in good agreement with the numerical simulations, showing the potential of the level set method to simulate resin infusion

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modern functional neuroimaging methods, such as positron-emission tomography (PET), optical imaging of intrinsic signals, and functional MRI (fMRI) utilize activity-dependent hemodynamic changes to obtain indirect maps of the evoked electrical activity in the brain. Whereas PET and flow-sensitive MRI map cerebral blood flow (CBF) changes, optical imaging and blood oxygenation level-dependent MRI map areas with changes in the concentration of deoxygenated hemoglobin (HbR). However, the relationship between CBF and HbR during functional activation has never been tested experimentally. Therefore, we investigated this relationship by using imaging spectroscopy and laser-Doppler flowmetry techniques, simultaneously, in the visual cortex of anesthetized cats during sensory stimulation. We found that the earliest microcirculatory change was indeed an increase in HbR, whereas the CBF increase lagged by more than a second after the increase in HbR. The increased HbR was accompanied by a simultaneous increase in total hemoglobin concentration (Hbt), presumably reflecting an early blood volume increase. We found that the CBF changes lagged after Hbt changes by 1 to 2 sec throughout the response. These results support the notion of active neurovascular regulation of blood volume in the capillary bed and the existence of a delayed, passive process of capillary filling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thesis (Master, Civil Engineering) -- Queen's University, 2016-06-01 00:03:02.939

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Subaerial debris flows, with water contents ranging from as little as 10 wt% up to no more than about 25 wt% (Pierson, 1986; Pierson and Costa, 1987), are non-Newtonian fluids that move as fairly coherent masses with yield strength (owing to bulk densities and viscosity that are much greater than those of clear water), which enables them to suspend and transport large clasts. Their flow behavior is thought to be predominantly laminar, although the relative importance of laminar and turbulent flow has not been established and is debatable. They leave deposits (debrites) that are characteristically poorly sorted with large clasts in their middle portions and commonly protruding from their tops. Although generally ungraded or normally graded in their upper portions, many have centimeter- to decimeter-thick inversely graded basal zones (Arguden and Rodolfo, 1990, doi:10.1130/0016-7606(1990)102<0865:SADDBH>2.3.CO;2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of sand ripples in an oscillatory-flow water tunnel was observed in 104 laboratory experiments approximating conditions at the seabed under steady progressive surface waves. The period, T, and amplitude, a, of the water motion were varied over wide ranges. Three quartz sands were used, with mean grain diameters, D = 0.55, 0.21, and 0.18 millimeter. In 24 experiments, with the bed initially leveled, T was reduced until ripples appeared, and their development to final equilibrium form was observed without further change in T. The remaining 80 experiments investigated the response of previously established bed forms to changes in T or a or both. The ripple length, lambda, and height, eta, were measured from photos, except when bed forms were three dimensional.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A mathematical model that describes the operation of a sequential leach bed process for anaerobic digestion of organic fraction of municipal solid waste (MSW) is developed and validated. This model assumes that ultimate mineralisation of the organic component of the waste occurs in three steps, namely solubilisation of particulate matter, fermentation to volatile organic acids (modelled as acetic acid) along with liberation of carbon dioxide and hydrogen, and methanogenesis from acetate and hydrogen. The model incorporates the ionic equilibrium equations arising due to dissolution of carbon dioxide, generation of alkalinity from breakdown of solids and dissociation of acetic acid. Rather than a charge balance, a mass balance on the hydronium and hydroxide ions is used to calculate pH. The flow of liquid through the bed is modelled as occurring through two zones-a permeable zone with high flushing rates and the other more stagnant. Some of the kinetic parameters for the biological processes were obtained from batch MSW digestion experiments. The parameters for flow model were obtained from residence time distribution studies conducted using tritium as a tracer. The model was validated using data from leach bed digestion experiments in which a leachate volume equal to 10% of the fresh waste bed volume was sequenced. The model was then tested, without altering any kinetic or flow parameters, by varying volume of leachate that is sequenced between the beds. Simulations for sequencing/recirculating 5 and 30% of the bed volume are presented and compared with experimental results. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vermicompost filtration is a new on-site waste treatment system. Consequently, little is known about the filter medium properties. The aim of this preliminary study was to quantify physical and compositional properties of vermicompost filter beds that had been used to treat domestic solid organic waste and wastewater. This paper presents the trials performed on pilot-scale reactors filled with vermicompost from a full-scale vermicompost filtration system. Household solid organic waste and raw wastewater at the rate of 130 L/m(2)/d was applied to the reactor bed surface over a four-month period. It was found that fresh casts laid on the bed surface had a BOD of 1290 mg/g VS while casts buried to a depth of 10 cm had a BOD of 605 mg/g VS. Below this depth there was little further biodegradation of earthworm casts despite cast ages of up to five years. Solid material in the reactor accounted for only 7-10% of the reactor volume. The total voidage comprised of large free-draining pores, which accounted for 15-20% of the reactor volume and 60-70% micropores, able to hold up water against gravity. It was shown that water could flow through the medium micropores and macropores following a wastewater application. The wastewater flow characteristics were modeled by a two-region model based on the Richards Equation, an equation used to describe porous spatially heterogeneous materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the value of cusum analysis in hospital bed management. Design: Comparative analysis of medical patient flows, bed occupancy, and emergency department admission rates and access block over 2 years. Setting: Internal Medicine Services and Emergency Department in a teaching hospital. Interventions: Improvements in bed use and changes in the level of available beds. Main outcome measures: Average length of stay; percentage occupancy of available beds; number of patients waiting more than 8 hours for admission (access block); number of medical patients occupying beds in non-medical wards; and number of elective surgical admissions. Results: Cusum analysis provided a simple means of revealing important trends in patient flows that were not obvious in conventional time-series data. This prompted improvements in bed use that resulted in a decrease of 9500 occupied bed-days over a year. Unfortunately and unexpectedly, after some initial improvement, the levels of access block, medical ward congestion and elective surgical admissions all then deteriorated significantly. This was probably caused by excessive bed closures in response to the initial improvement in bed use. Conclusion: Cusum analysis is a useful technique for the early detection of significant changes in patient flows and bed use, and in determining the appropriate number of beds required for a given rate of patient flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An X-ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two-dimensional (2-D) packed bed. A medical diagnostic X-ray unit has been used to image the local holdups in a 2-D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X-ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X-ray method, has been compared with two conventional methods: drainage and tracer response. The X-ray technique, after validation, has been used to visualize and quantify, the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. (c) 2005 American Institute of Chemical Engineers

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Applications of the axisymmetric Boussinesq equation to groundwater hydrology and reservoir engineering have long been recognised. An archetypal example is invasion by drilling fluid into a permeable bed where there is initially no such fluid present, a circumstance of some importance in the oil industry. It is well known that the governing Boussinesq model can be reduced to a nonlinear ordinary differential equation using a similarity variable, a transformation that is valid for a certain time-dependent flux at the origin. Here, a new analytical approximation is obtained for this case. The new solution,, which has a simple form, is demonstrated to be highly accurate. (c) 2005 Elsevier Ltd. All rights reserved.