959 resultados para Minimum Inductance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this work is to predict the minimum fluidization velocity Umf in a gas-solid fluidized bed. The study was carried out with an experimental apparatus for sand particles with diameters between 310μm and 590μm, and density of 2,590kg/m3. The experimental results were compared with numerical simulations developed in MFIX (Multiphase Flow with Interphase eXchange) open source code [1], for three different sizes of particles: 310mum, 450μm and 590μm. A homogeneous mixture with the three kinds of particles was also studied. The influence of the particle diameter was presented and discussed. The Ergun equation was also used to describe the minimum fluidization velocity. The experimental data presented a good agreement with Ergun equation and numerical simulations. Copyright © 2011 by ASME.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the inverter input current but this also affects the load with low-order harmonics and generate disturbances at the input voltage. This paper applies the P+RES controller to solve the challenge of regulating the output current by means of controlling the magnitude of the current space vector, keeping it constant thus rejecting harmonic disturbances that would otherwise propagate to the load. This work presents a discussion of the switching and control strategy. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports the effects of dexmedetomidine on the minimum alveolar concentration of isoflurane (MAC iso) in cats. Six healthy adult female cats were used. MAC iso and dexmedetomidine pharmacokinetics had previously been determined in each individual. Cats were anesthetized with isoflurane in oxygen. Dexmedetomidine was administered intravenously using target-controlled infusions to maintain plasma concentrations of 0.16, 0.31, 0.63, 1.25, 2.5, 5, 10, and 20ng/mL. MAC iso was determined in triplicate at each target plasma dexmedetomidine concentration. Blood samples were collected and analyzed for dexmedetomidine concentration. The following model was fitted to the concentration-effect data: where MAC iso.c is MAC iso at plasma dexmedetomidine concentration C, MAC iso.0 is MAC iso in the absence of dexmedetomidine, I max is the maximum possible reduction in MAC iso, and IC 50 is the plasma dexmedetomidine concentration producing 50% of I max. Mean±SE MAC iso.0, determined in a previous study conducted under conditions identical to those in this study, was 2.07±0.04. Weighted mean±SE I max, and IC 50 estimated by the model were 1.76±0.07%, and 1.05±0.08ng/mL, respectively. Dexmedetomidine decreased MAC iso in a concentration-dependent manner. The lowest MAC iso predicted by the model was 0.38±0.08%, illustrating that dexmedetomidine alone is not expected to result in immobility in response to noxious stimulation in cats at any plasma concentration. © 2011 Blackwell Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To compare five different protocols for estimating the lactate minimum speed (LMS) with that for estimating the maximal lactate steady state (MLSS) in Arabian horses, in order to obtain a more rapid method for monitoring aerobic capacity and prescribing training schedules. METHODS: Eight purebred Arabian horses were conditioned to exercise on a treadmill for 12 days then submitted to three to five exercise sessions to determine the MLSS. Blood samples were collected from a jugular catheter at specific intervals for measurement of lactate concentrations. The MLSS was the velocity maintained during the last 20 minutes of constant submaximal exercise, at which the concentration of lactate increased by no more than 1.0 mmol/L. The LMS test protocols (P1 - P5) included a warm-up period followed by a high-intensity gallop. The speed was then reduced to 4 m/s, and the incremental portion of the test was initiated. In P1, P2, and P3, the velocity increment was 0.5 m/s, and the duration of each incremental stage was three, five and seven minutes, respectively. In P4 and P5, the velocity increments were 1.0 and 1.5 m/s, respectively, and the duration of the stages was fixed at five minutes each. A second-degree polynomial function was fitted to the lactate-velocity curve, and the velocity corresponding to the lowest concentration of lactate was the LMS. RESULTS: Only the mean LMS determined by P1 and P2 did not differ from the velocity determined by the MLSS test (p > 0.1). There was a strong correlation (r >0.6) between P1 and the MLSS velocity. A limits of agreement plot revealed that the best agreement occurred between the MLSS test and P1 (mean bias = 0.14 m/s), followed by P2 (bias = -0.22 m/s). The lactate concentrations associated with the various LMS protocols did not differ. CONCLUSIONS: This study shows the variation between protocols of the LMS test for determining the onset of blood lactate accumulation but also reveals that, at least for Arabian horses, the P1 protocol of the LMS has good agreement with the MLSS. © 2013 Copyright New Zealand Veterinary Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel segmentation method for cuboidal cell nuclei in images of prostate tissue stained with hematoxylin and eosin. The proposed method allows segmenting normal, hyperplastic and cancerous prostate images in three steps: pre-processing, segmentation of cuboidal cell nuclei and post-processing. The pre-processing step consists of applying contrast stretching to the red (R) channel to highlight the contrast of cuboidal cell nuclei. The aim of the second step is to apply global thresholding based on minimum cross entropy to generate a binary image with candidate regions for cuboidal cell nuclei. In the post-processing step, false positives are removed using the connected component method. The proposed segmentation method was applied to an image bank with 105 samples and measures of sensitivity, specificity and accuracy were compared with those provided by other segmentation approaches available in the specialized literature. The results are promising and demonstrate that the proposed method allows the segmentation of cuboidal cell nuclei with a mean accuracy of 97%. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to validate the lactate minimum test as a specific aerobic evaluation protocol for table tennis players. Using the frequency of 72 balls·min-1 for 90 sec, an exercise-induced metabolic acidosis was determined in 8 male table tennis players. The evaluation protocol began with a frequency of 40 balls·min-1 followed by an increase of 8 balls·min-1 every 3 min until exhaustion. The mean values that corresponded to the subjects' lactate minimum (Lacmin) were equal to 53.1 ± 1.5 balls·min-1 [adjusted for the time test (Lacmin_time)] and 51.6 ± 1.6 balls·min-1 [adjusted for the frequency of balls (Lacmin_Freq)], which resulted in a high correlation between the two forms of adjustment (r = 0.96 and (P = 0.01). The mean maximum lactate steady state (MLSS) was 52.6 ± 1.6 balls·min-1. Pearson's correlations between Lacmin_time vs. MLSS and Lacmin_freq vs. MLSS were statistically significant (P = 0.03 and r = 0.86, P = 0.03 and r = 0.85, respectively). These findings indicate that the Lacmin test predicts MLSS. Therefore, it is an excellent method to obtain the athletes' anaerobic threshold. Also, there is the advantage that it can be performed in 1 day in the game area. However, the Lacmin value does not depend on the Lacpeak value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Researches concerning cooling-lubrication optimization in grinding have been conducted to contribute to a more sustainable process. An alternative to flood coolant is minimum quantity lubrication (MQL), which spray oil droplets in a compressed air jet. However, problems related to wheel cleaning were reported, due to wheel loading by a mixture of chips and oil, resulting in worsening of surface quality. This work aims to evaluate the viability of Teflon and aluminum oxide for wheel cleaning, compared to MQL without cleaning and MQL with cleaning by compressed air, through the following output variables: surface roughness, roundness, wheel wear, grinding power and acoustic emission. Vickers microhardness measurements and optical microscopy were also carried out. The results showed that both materials were efficient in cleaning the wheel, compared to MQL without cleaning, but not as satisfactory as compressed air. Much work is to be done in order to select the right material for wheel cleaning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zagatto, AM, Padulo, J, Muller, PTG, Miyagi, WE, Malta, ES, and Papoti, M. Hyperlactemia induction modes affect the lactate minimum power and physiological responses in cycling. J Strength Cond Res 28(10): 2927-2934, 2014The aim of this study was to verify the influence of hyperlactemia and blood acidosis induction on lactate minimum intensity (LMI). Twenty recreationally trained males who were experienced in cycling (15 cyclists and 5 triathletes) participated in this study. The athletes underwent 3 lactate minimum tests on an electromagnetic cycle ergometer. The hyperlactemia induction methods used were graded exercise test (GXT), Wingate test (WAnT), and 2 consecutive Wingate tests (2 x WAnTs). The LMI at 2 x WAnTs (200.3 +/- 25.8 W) was statistically higher than the LMI at GXT (187.3 +/- 31.9 W) and WAnT (189.8 +/- 26.0 W), with similar findings for blood lactate, oxygen uptake, and pulmonary ventilation at LMI. The venous pH after 2 x WAnTs was lower (7.04 +/- 0.24) than in (p <= 0.05) the GXT (7.19 +/- 0.05) and WAnT (7.19 +/- 0.05), whereas the blood lactate response was higher. In addition, similar findings were observed for bicarbonate concentration [HCO3] (2 x WAnTs lower than WAnT; 15.3 +/- 2.6 mmol center dot L-1 and 18.2 +/- 2.7 mmol center dot L(-)1, respectively) (p <= 0.05). However, the maximal aerobic power and total time measured during the incremental phase also did not differ. Therefore, we can conclude that the induction mode significantly affects pH, blood lactate, and [HCO3] and consequently they alter the LMI and physiological parameters at LMI.