313 resultados para Microparticles


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to obtain plasma thin film composites with hydrophobic/hydrophilic alternated regions, which are useful for the production of miniaturized mixers. These regions were acquired by two different strategies: either the codeposition of TEOS and HFE plasma thin films or the exposition of TEOS plasma films to ultraviolet radiation (UVA and UVC). These films were characterized by several chemical and physical techniques. The refractive indexes vary from 1.4 to 1.7; infrared and photoelectron spectroscopy detect Si-O-Si and CHn species. Silicone-like structures with high or low number of amorphous carbon microparticles and with fluorinated organic clusters were produced. Cluster dimensions were in the 1-5 mm range and they are made of graphite or COF (carbon/oxygen/fluorine) compounds. Scanning electron and optical microscopy showed rough surfaces. Water contact angles were 90º; however, for TEOS films that value changed after 6 hr of UVC exposure. Moreover, after UV exposure, organic polar compounds could be adsorbed in those films and water was not. The passive mixer performance was simulated using the FemLab 3.2® program and was tested with 20 nm thick films on a silicon wafer, showing the capacity of these films to be used in such devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a clinical case report of a patient who presented with dental stains in the buccal and proximal aspects of the anterior teeth. Buccal stains were removed using the enamel microabrasion technique, and vital tooth bleaching with carbamide peroxide was also performed. Restorative procedures employing composite resin were done for a better result in the proximal aspect of teeth. Clinical significance: The authors observed the combination of these esthetic techniques improved the patient's smile. Today, dental esthetics attempts to imitate natural teeth by making them white, well-shaped, and aligned with no spots. This has enabled the development of several esthetic techniques, such as microabrasion to remove dental enamel surface stains and surface irregularities,1-6 and vital tooth bleaching to treat yellowish teeth.7 The enamel microabrasion technique uses different abrasive agents associated with chemical solutions,1,2,4,6 allowing the removal of intrinsic, hard-texture stains, and different coloring spots on the enamel surface, as well as correction of irregularities on the dental buccal surface.1,8 The various microabrasive products include the Opalustre® (Ultradent Products, http://www.ultradent.com)or Prema® Compound (Premier Dental Products, http://www.premusa.com), a low-concentration hydrochloric acid product associated with silica microparticles that is certainly effective for microabrasion technique,4,6,9,10 providing a good safety profile for the patient and professional. The microabrasion technique also promotes micro-reduction on the adamantine surface.4,5,10 In some cases, after its completion, microabrasion may cause teeth to become darker or yellowish because of the thinner remaining enamel surface, leading to more evident observation of the dentinal tissue, which in general determines tooth color. In these clinical conditions, correction of the color pattern of dental elements can be obtained with carbamide peroxide products applied in custom trays, such as the bleaching products Whiteness Perfect at 10% or 16% (FGM Productos Odontologicos, http://www.fgm.ind.br) or Opalescence® at 10% or 15% (Ultradent Products), with a considerable margin of clinical success, provided it is well indicated, well performed, and supervised by the professional.4,6,9,10 Considering all the aforementioned aspects, the authors present a clinical case about a dental-enamel microabrasion technique used to remove buccal enamel surface stains associated with dental vital bleaching and restorative procedures in the proximal aspect of anterior teeth. - See more at: https://www.dentalaegis.com/cced/2010/08/different-esthetic-techniques-used-in-combination-to-recover-the-smile#sthash.McFoH7El.dpuf

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We studied the effect of silica surface on luminescence properties of terbium complex by spectroscopy characterization, where microparticles of mesoporous silica type MSU-X was prepared. We used silica with different surface: calcined, washed, functionalized with 3- aminopropyl-triethoxysilane (APTES), and 3-glycidoxypropyl-trimethoxysilane (GPTMS); impregnated with Tb3+-glutamic acid complex. The obtained materials were characterized by scanning electron microscopy, porosity measurements, small-angle X-ray scattering, as structural characterization; Fourier transform infrared and luminescence spectroscopy, as spectroscopy characterization. Finally, we observed that functional groups at the silica surface lead to changes on luminescent properties of the final materials. The observed shift of the absorption and emission bands can be assigned to the effect of the functional groups of mesoporous silica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different types of shed vesicles as, for example, exosomes, plasma-membrane-derived vesicles or microparticles, are the focus of intense research in view of their potential role in cell cell communication and under the perspective that they might be good tools for immunotherapy, vaccination or diagnostic purposes. This review discusses ways employed by pathogenic trypanosomatids to interact with the host by shedding vesicles that contain molecules important for the establishment of infection, as opposed to previous beliefs considering them as a waste of cellular metabolism. Trypanosomatids are compared with Apicomplexa, which circulate parasite antigens bound to vesicles shed by host cells. The knowledge of the origin and chemical composition of these different vesicles might lead to the understanding of the mechanisms that determine their biological function. (C) 2012 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents a study on the effects of the particle size, material concentration and radiation energy on the X-ray absorption. CuO nanoparticles and microparticles were incorporated separately into a polymeric resin in concentrations of 5%, 10% and 30% relative to the resin mass. X-ray absorption by these materials was analyzed with a CdTe detector. The X-ray absorption is higher for the nanostructured material compared to the microstructured one for low energy X-ray beams for all CuO concentrations. (c) 2011 Elsevier Ltd. All rights reserved.