872 resultados para Micro Tomography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis®. Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO:Os recentes progressos na imagiologia médica possibilitaram um papel de destaque para a Tomografia Axial Computorizada Multicorte no estadiamento do carcinoma do estômago (GA). Foi objetivo deste estudo avaliar a acuidade desta técnica no estadiamento T (invasão mural) e N (ganglionar) e avaliar fatores de prognóstico como fatores de representação/substituição para melhorar a referida acuidade. Sessenta e nove pacientes operados a carcinoma gástrico (GA) entre Janeiro de 2010 e Julho de 2012 e avaliados por Tomografia Computorizada, a maioria recorrendo a técnica de multicorte com distensão gástrica, foram estadiados retrospetivamente por três imagiologistas. Utilizaram-se critérios de avaliação referidos na literatura especializada e fatores de substituição/representação nos estadios menos eficazes. O estadiamento T revelou acuidade de 66,7% e sensibilidade de 92% e a acuidade, sensibilidade e especificidade obtidas para o estadiamento N foram respetivamente 49%, 40,9% e 64%. Usando um fator de substituição de estadiamento diagnóstico T4/N2 para mudar o estadiamento N2 obtido por MDCT para estadiamento N3A aumentaria a acuidade do estadiamento N para 59% e a sensibilidade para 58,1% e baixaria a especificidade para 61,5%, embora essa mudança não fosse estatisticamente significativa (Teste exato de Fisher 0,159). Em conclusão a acuidade de uma técnica simples de MDCT com distensão gástrica no estadiamento T e N do GA está dentro dos valores citados na literatura e fatores de substituição/representação como o estadiamento T4 e o tipo Difuso da classificação de Lauren podem melhorar a acuidade do estadiamento N.-------------- ABSTRACT: Recent innovations in medical sectional imaging have allowed a major role of multi-detector computed tomography (MDCT) in staging of gastric adenocarcinoma (GA). The purpose of this study was to evaluate the accuracy of this technique in depth of mural invasion (T) and nodal (N) staging of GA and to evaluate prognostic factors as surrogate factors to improve such accuracy. Sixty nine patients operated to GA between January 2010 and July 2012 that underwent Computed Tomography, the majority through Multidetector Computed Tomography (MDCT) with gastric distention, were staged retrospectively by three imagiologists with state-of-the-art criteria and surrogate prognostic factors were analyzed for less accurate stages. MDCT T-staging was 66,7 % accurate with a sensibility of 92 % and there was a 49 % accuracy, 40,9 % sensibility and 64 % specificity for N Staging. Using a surrogate factor of T4/N2 diagnostic staging to change diagnostic MDCT N2 disease to N3A disease would increase accuracy of N staging to 59% and sensibility to 58,1% and would decrease specificity to 61,5 %, although that change was not statistically significant (Fisher´s Exact Test 0,159)In conclusion the accuracy of a simple hydro-MDCT technique in T and N staging of GA is in the range of values cited in the literature and surrogate factors as diagnostic T4 disease and diffuse type of Lauren´s Classification may improve the accuracy of N staging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Do Ceará, estado com problema de Doença de Chagas, Russas tem recebido a maior soma de investigações, verificando-se 11,6% de infecção humana, em 1959. Recentemente foram examinados cães, gatos e outros animais encontrando-se altas taxas de infecção. Selecionou-se, na presente pesquisa, uma micro-área (Fazenda Boa Vista) na região, onde haviam sido antes examinados 52 cães e 21 gatos, com 11 cães e 10 gatos positivos. Foram examinados mais 12 cães e 10 gatos, com 1 e 5 positivos, respectivamente, elevando-se a taxa de positividade global para 29,5%. Nessa micro-área foram examinados 125 pessoas pela RFC e pelo xenodiagnóstico, encontrando-se uma positividade de 7,2%. Desses positivos, 55% residem em casas com animal positivo, sendo que duas casas apresentaram duas pessoas positivas cada. Do total de xenos somente dois foram positivos. Na micro-área foram capturados 405 triatomíneos, com 27,7% positivos, dentro e fora das casas (galinheiros, currais, paredes externas, telheiros e alpendres). A espécie prevalente é o Triatoma brasiliensis (93,5%), encontrada dentro das casas (52,8%) com taxa de infecção de 30,2% e fora das casas (47,2%) com 24,6% de infecção. No total da região examinada na pesquisa anterior, as taxas de infecção foram 19,6% dentro das casas e 21,8% fora. A segunda espécie é o T. pseudomaculata (5,4%), encontrado mais fora das casas (72,8%) e infectado 25%. Foram capturados 8 exemplares de P. megistus sempre fora das casas, sendo 4 na micro-área; 5 exemplares estavam infectados. Na micro-área, tal como em 2 outras áreas da região, foram encontrados roedores domésticos e marsupiais com T. cruzi: 4 em 10 Rattus rattus e 1 em 3 Didelphis azarae, tal como já havia sido verificado por um dos AA. em outras áreas do Estado. Conclui-se pela existência de um dinâmico ciclo doméstico e paradoméstico de circulação do T. cruzi na micro-área, com abundantes oportunidades de infecção do homem e dos animais domésticos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary optical coherence tomography has emerged as the most powerful in-vivo imaging modality to evaluate vessel structure in detail. It is a useful research tool that provides insights into the pathogenesis of coronary artery disease. This technology has an important clinical role that is still being developed. We review the evidence on the wide spectrum of potential clinical applications for coronary optical coherence tomography, which encompass the successive stages in coronary artery disease management: accurate lesion characterization and quantification of stenosis, guidance for the decision to perform percutaneous coronary intervention and subsequent planning, and evaluation of immediate and long-term results following intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

International Seminar on Seismic Risk and Rehabilitation of Stone Masonry Housing, Azores, Portugal, 1998

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Probing micro-/nano-sized surface conformations, which are ubiquitous in biological systems, by using liquid crystal droplets, which change their ordering and optical appearance in response to the presence of more than ten times smaller cellulose based micro/nano fibers, might find new uses in a range of biological environments and sensors. Previous studies indicate that electrospun micro/nano cellulosic fibers produced from liquid crystalline solutions could present a twisted form [1]. In this work, we study the structures of nematic liquid crystal droplets threaded by cellulose fibers prepared from liquid crystalline and isotropic solutions as well as droplets pierced by spider-made fibers [2]. Planar anchoring at the fibers and planar and homeotropic at the drop surfaces allowed probing cellulose fibers different helical structures as well as aligned filaments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro/nano wrinkled patterns on cross-linked urethane/urea polymeric flexible free standing films with two soft segments, polypropylene oxide and polybutadiene, can be induced by UV-irradiation. The ability to write/erase these 3D structures, in a controlled manner, is the main focus of this work. The imprinting of the wrinkled structures was accomplished by swelling in an appropriate solvent followed by drying the membranes after the cross-linking process and UV irradiation. The surface tailoring of the elastomeric membranes was imaged by optical microscopy, scanning electronic microscopy and by atomic force microscopy. To erase the wrinkled structures the elastomers were swollen. The swelling as well as the sol/gel fraction and the UV radiation were tuned in order to control the wrinkles characteristics. It was found that the wrinkles wavelength, in the order of microns (1±0,25μm), was stamped by the UV radiation intensity and exposure time while the wrinkles' amplitude, in the order of nanometers (150-450 nm), was highly dependent on the swelling and sol/gel fraction. A prototype for volatile organic compounds detection was developed taking advantage of the unique 3D micro/nano wrinkles features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As Micro e Pequenas Empresas (MPE) possuem na sua essência recursos limitados. Raramente possuem um Sistema Integrado de Gestão (SIG) que lhes permita gerir o seu negócio de forma transversal e que mapeie todos os processos da empresa. Devido ao número reduzido de colaboradores, não dispõem internamente alguns serviços. O seu espaço de mercado é em geral limitado. As suas competências específicas raramente permitem apresentar uma oferta global. Por serem pequenas, não têm força negocial perante os seus fornecedores e eventuais parceiros estratégicos. A Arquitetura de Sistemas de Informação (ASI) permite representar e mapear os diversos aspetos da gestão das empresas e alinhar as Tecnologias de Informação e Comunicação (TIC) com as necessidades destas empresas. Este trabalho pretende apresentar e descrever uma Macro Arquitetura para a construção de SIG, orientados para as MPE, e que inclua um conjunto de serviços integrados numa única plataforma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Programmes supporting micro and small enterprises in developing countries have been showing that capital is not enough to allow business success: survival and growth. Literature does not provide comprehensive and practical tool to support business development in this context, but allowed the collection of forty-nine success variables that were studied in a sample of successful and unsuccessful businesses in the Island of Mozambique to discover what were the key factors affecting those businesses’ performance. Empirical data gave the insights for the development of a model to screen and improve business potential of micro and small enterprises in this context.