989 resultados para Maxillofacial, Prosthesis.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to investigate the relationship among radiographic features observed on panoramic radiographs of sickle cell disease patients and analyze their relationship with history of systemic severity of the disease. Panoramic radiographs of 71 subjects with sickle cell disease were evaluated for the presence of the following radiographic bony alterations: radiopaque areas, increased spacing of bony trabeculae, horizontal arrangement of bony trabeculae and corticalization of mandibular canal. History of clinical systemic severity was assessed through direct questioning about the frequency of vaso-occlusive crisis, history of stroke, clinical jaundice, femur head necrosis, and leg ulceration. Chi-square or Fisher's exact test were applied in order to analyze possible associations between radiographic features and history of complications, with < 0.05 significance level. Increased spacing of bony trabeculae was statistically associated with absence of corticalization of mandibular canal ( < 0.01) and horizontal arrangement of bony trabeculae ( = 0.04). Statistically significant associations were demonstrated between history of clinical jaundice and presence of increased spacing of bony trabeculae ( = 0.02) and between history of stroke and presence of horizontal arrangement of bony trabeculae ( = 0.04). Based on the results of the current study, maxillofacial radiographic features may be associated with clinical parameters of systemic complications in sickle cell disease patients. The relationship between radiographic features and history of complications associated with clinical severity of sickle cell disease has not been demonstrated in the literature. Acknowledgment of such possible association may help establish prognosis and influence clinical treatment of systemic and oral complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the colour stability of paints used for ocular prosthesis iris painting submitted for accelerated artificial ageing (AAA). Materials and methods: Forty specimens of acrylic resin for sclera (16 x 2 mm) were made and separated into eight groups (n = 10) according to the type of paint (gouache, GP; oil, OP; acrylic AP; and composite resin for characterisation, CR) and the colours used (blue/brown). After drying (72 h), a new layer of colourless acrylic resin was applied and the initial colour readout was performed (Spectrophotometer PCB 6807). New colour readouts were performed after AAA, and Delta E was calculated. Results: Statistical analysis (two-way ANOVA-Bonferroni, p < 0.05) demonstrated that the brown colour showed lower Delta E means in comparison with the blue colour, with statistically significant difference for AP only. Blue colour showed no statistically significant difference with regard to the type of paint used. Brown AP showed lower Delta E than the other groups, with significant difference for OP and GP. GP showed greater alteration in Delta E for the brown colour, being statistically similar only to OP. Conclusions: Only the AP group for brown pigment shows clinically acceptable values for colour stability after AAA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to analyze the criteria employed for the requesting of preoperative tests among maxillofacial surgeons. Materials and methods: Thirty maxillofacial surgeons working in Aracaju (Brazil) received a questionnaire to fill out. The study inquired about the practice of requesting preoperative tests for healthy patients scheduled to undergo elective surgery. Results: Most of the surgeons interviewed requested tests that are not recommended for the case in question. The highest frequency of requests was a complete blood count, coagulation test, blood glucose test and chest radiograph. Conclusion: The absence of strict rules for the requesting of preoperative tests causes uncertainty and a lack of criteria regarding pre-surgical conduct. It was not possible to clearly define the criteria used by surgeons for requesting such tests, as the clinical characteristics of the hypothetical case presented suggest a smaller number of tests. (C) 2011 European Association for Cranio-Maxillo-Facial Surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this retrospective study was to clarify the occurrence and types of dental injuries in 389 patients who had been diagnosed with facial fractures, and to analyze whether the occurrence of dental injury correlates to gender, age, trauma mechanism and type of facial fracture. Dental injuries were observed in 62 patients (16%). The most common type of injury was a crown fracture (48%). Dental injuries were multiple in most patients (63%). Almost half (48%) of all injured teeth were severely injured. Most injured teeth (61%) were in the maxilla. The incisor region was the most prevalent site in both the mandible (45%) and the maxilla (56%). The occurrence of dental injury correlated significantly with trauma mechanism and fracture type: motor vehicle accidents and mandibular fracture were significant predictors for dental trauma. The notable rate of dental injury observed in the present study emphasizes the importance of a thorough examination of the oral cavity in all patients who have sustained facial fracture. Referral to a dental practice for further treatment and follow up as soon as possible after discharge from hospital is fundamental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present the case of an 81-year-old patient with severe aortic stenosis who experienced left ventricular embolization of an aortic bioprosthesis during transapical aortic valve implantation. The authors discuss reasons for prosthesis embolization and reinforce the attention to technical details and the widespread use of multimodality imaging techniques. In this context, transesophageal echocardiography appears indispensable in the detection and management of procedure-related complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a computationally efficient and biomechanically relevant soft-tissue simulation method for cranio-maxillofacial (CMF) surgery. A template-based facial muscle reconstruction was introduced to minimize the efforts on preparing a patient-specific model. A transversely isotropic mass-tensor model (MTM) was adopted to realize the effect of directional property of facial muscles in reasonable computation time. Additionally, sliding contact around teeth and mucosa was considered for more realistic simulation. Retrospective validation study with postoperative scan of a real patient showed that there were considerable improvements in simulation accuracy by incorporating template-based facial muscle anatomy and sliding contact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To date, transapical aortic valve implantation has required a balloon-expandable stented valve prosthesis. More recently, a novel self-expanding sutureless stented bovine pericardial prosthesis has been developed which allows rapid aortic valve replacement via an open transaortic approach in humans. The aim of this animal study was to develop a reliable protocol to facilitate the transapical implantation of this self-expanding valve in a porcine model.