897 resultados para Mandibular fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Pressure ulcer (PU) is a frequent complication of hip fracture. Studies were carried out to identify the risk factors of PU development after hip fractures. The objective of the study was to determine the role of anthropometric measurements and handgrip strength as predictors of PUs in patients with hip fractures during their hospital stay and 30 d after discharge, which has not yet been established.Methods: Ninety-two consecutive patients with hip fractures who were older than 65 y old and admitted to an orthopedic unit were prospectively evaluated. Within the first 72 h of admission, each patient's characteristics were recorded, anthropometric measurements were taken (circumferences of the arm, waist, thigh, calf, triceps, and biceps and subscapular and suprailiac skinfolds), handgrip strength was measured, and blood samples were collected. PU evaluations were performed during the hospital stay and 30 d after hospital discharge.Results: Three patients were excluded because of PUs before hospitalization. Eighty-nine patients (average age 80.6 +/- 7.5 y) were studied; 70.8% were women, and 49.4% developed PUs during their hospital stay. In a univariate analysis, length of hospital stay (P = 0.001) and handgrip strength (P = 0.02), but not body circumferences and skinfolds, were associated with PUs during a hospital stay. Only handgrip strength (P = 0.007) was associated with PUs 30 d after hospital discharge. In a multivariate analysis, only handgrip strength was found to predict PU development at these points.Conclusion: Handgrip strength was found to predict PU development in patients with hip fractures during their hospital stay and 30 d after discharge. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Descreve-se um surto de abscesso mandibular em ovelhas da raça Bergamácia no município de Botucatu, estado de São Paulo. do rebanho de 120 animais, 35 apresentaram aumento de volume mandibular com a presença de nódulos únicos, de consistência pétrea, de diferentes tamanhos, fistulados ou não e sem indicativos de inflamação dos tecidos moles adjacentes. Os animais eram criados em pasto de Panicum maximum cv. Tanzânia com água e sal mineral ad libitum e everminados, via oral, com pistolas dosificadoras. O material para diagnóstico microbiológico e antibiograma foi coletado de cinco animais acometidos, por punção e aspiração dos nódulos. Dos 35 animais acometidos, 19 foram submetidos ao exame radiográfico, um ao exame tomográfico e outro à biópsia óssea da região submandibular. O único ovino que morreu, encontrava-se em estado de caquexia provavelmente devido à localização do aumento de volume que afetou a implantação dos dentes molares daquela região impedindo a apreensão e mastigação adequadas levando a perda da condição corporal e morte. Ao exame necroscópico, observaram-se áreas de necrose caseosa na mandíbula direita de onde isolou-se Pseudomonas aeruginosa. O tratamento utilizado foi baseado na aplicação de iodeto de sódio a 10% por via intramuscular e antibioticoterapia segundo antibiograma com enrofloxacina por via intramuscular, porém com pouca eficácia. Diante do quadro clínico, dos dados de anamnese, da localização das lesões no tecido ósseo mandibular, do resultado do cultivo microbiológico, das alterações radiográficas e tomográficas foi feito o diagnóstico de abscesso mandibular causado por Pseudomonas aeruginosa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivou-se, com este experimento, avaliar a ação da ropivacaína a 0,5% no bloqueio do nervo alveolar mandibular de gatos. Vinte gatos adultos, sem raça definida, machos ou fêmeas, receberam clorpromazina (1,0mg kg-1, VO) e propofol (3,0mg kg-1, IV). Ropivacaína a 0,5% foi administrada com uma agulha 13x3,8 em forma de L, inserida no ângulo da mandíbula direita, aproximadamente 1,0cm rostral ao processo angular e 0,5cm dorsal à superfície medial do ramo da mandíbula, a fim de depositá-la próximo ao nervo alveolar mandibular, no forame mandibular. As freqüências cardíaca e respiratória foram mensuradas antes da administração da clorpromazina, 20 minutos após administração desta (T0), 20 minutos após o bloqueio do nervo alveolar mandibular com ropivacaína (T20) e, em intervalos de 20 minutos, até a volta da sensibilidade na região anestesiada. Observou-se o período de latência e a duração da anestesia por meio do pinçamento da pele e gengiva da região lateral direita da mandíbula. Encontrou-se início da anestesia após 22 minutos, com duração de 164,25 minutos. Os parâmetros de freqüência cardíaca e freqüência respiratória tiveram alterações, porém sem significado clínico para a espécie. A ropivacaína a 0,5% anestesia a região dos dentes pré-molares, molares, caninos, incisivos, pele e mucosa oral e lábio inferior, sem causar efeitos colaterais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern techniques for surgical treatment of midfacial and panfacial fractures in maxillofacial trauma lead to special problems for airway management. Usually, in perioperative management of panfacial fractures, the surgeon needs to control the dental occlusion and nasal pyramid assessment. For these reasons, oral and nasal endotracheal intubations are contraindicated for the management of panfacial fractures. Tracheotomy is considered by many as the preferred route for airway management in patients with severe maxillofacial fractures, but there are often perioperative and postoperative complications concerning this technique. The submental route for endotracheal intubation has been proposed as an alternative to tracheotomy in the surgical management of patients with panfacial fractures, besides it is accompanied by low morbidity. Thus, this paper aimed to describe the submental endotracheal intubation technique in a patient experiencing panfacial fracture. The subject was well treated using the submental endotracheal intubation to get good reconstruction of the fractures because the authors obtained free access of all facial fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study verified the resistance to displacement of six miniplate fixation methods after sagittal split osteotomy (SSO). SSO was performed in 30 polyurethane synthetic mandible replicas. The distal segments were advanced (4 mm) and specimens were grouped according to the fixation method: four-hole standard miniplate; four-hole locking miniplate; six-hole standard miniplate; six-hole locking miniplate; six-hole standard sagittal miniplate; six-hole locking sagittal miniplate. Biomechanical evaluation was performed by applying compression loads to three points on the second molar region, using an Instron universal testing machine until a 3 mm displacement of the segments occurred. Compression loads able to produce 3 mm displacement were recorded in kN and subjected to analysis of variance (P < 0.01) and Tukey's tests for comparison between groups (P < 0.05). The locking sagittal miniplate showed higher resistance to displacement than the regular four- and six-hole locking and standard miniplates. No significant differences were observed between the locking sagittal miniplate and the regular sagittal or the four-hole locking miniplates. Two of the three groups with the best results had locking plate fixation methods. Fixation of SSO with a single miniplate is better accomplished using six-hole locking sagittal miniplates, six-hole standard sagittal miniplates, or four-hole locking miniplates; these methods are more resistant to displacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of the study was to analyze 2-flap designs for surgical extraction of third molar, evaluating the periodontal status of the second lower molar.Study Design: Forty-five lower third molars were extracted from 24 patients. In 23 teeth, a vertical incision to the mandibular ramus was used (technique A), whereas 22 teeth were submitted to classic L-shaped flap (technique B) with controls at 60 and 90 days postoperatively.Results: Pearson correlation coefficient analysis showed a significant correlation only between immediate preoperative probing depth variables from techniques A and B in the studied surfaces. Statistical significances in the preoperative (vestibular) and postoperative day 60 (distovestibular and vestibular) were noted. In contrast, Student t-test showed no statistical difference in probing depths between preoperative and postoperative values, as well as no statistically significant difference regarding the type of incision alone.Conclusions: Technique A allowed a less traumatic surgery, guaranteeing a more comfortable postoperative period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traumatic tooth injuries involve function and aesthetics and cause damage that range from minimal enamel loss to complex fractures involving the pulp tissue and even loss of the tooth crown. Technical knowledge and clinical experience are essential to establish an accurate diagnosis and provide a rational treatment. The purpose of this study was to evaluate the knowledge of Restorative Dentistry specialists about the management of crown and crown-root fractures based on treatment plans proposed by these professionals for these cases. A descriptive questionnaire was mailed to 245 Restorative Dentistry specialists with questions referring to their professional profile and the treatment plans they would propose for the management of crown and crow-root fractures resulting from dental trauma. One hundred and fifty-four questionnaires were returned properly filled. The data were subjected to descriptive statistics and the chi-square test was used to determine the frequency and the level of the significance among the variables. The analysis of data showed that in spite of having a specialist title, all interviewees had great difficulty in planning the treatments. As much as 42.8% of the participants were unable to treat all types of dental trauma. Complicated and uncomplicated crown-root fractures posed the greatest difficulties for the dentists to establish adequate treatment plans because these fractures require multidisciplinary knowledge and approach for a correct case planning and prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Noncarious cervical lesions (NCCLs) are a frequent challenge in clinical dental practice, given the variety of opinions regarding their etiology, diagnosis, and treatment.Purpose. The purpose of this study was to assess the potential relationship between occlusal forces and the occurrence of NCCLs.Material and methods. The participant population consisted of 111 volunteers (30 male and 81 female, mean age 23.6 years). General personal information was recorded, after which participants were examined for the presence and location of NCCLs, gingival recession, fracture lines, dental and restoration fractures, presence and location of tooth wear, type of occlusal guidance scheme for lateral mandibular movements, and existence of occlusal interference or premature contacts. The participants were divided according to the presence or absence of NCCLs, and data were statistically analyzed with the Independent t test, the Chi-square test, and the Fisher exact test (alpha=.05).Results. A significant association was found between the presence of NCCLs and age (P=.008), gingival recession (P<.001), occlusal trauma (P<.001), presence (P<.001) and location of tooth wear, and group function as occlusal guidance scheme in lateral excursive movements (P<.001).Conclusions. A strong relationship between the presence of NCCLs and occlusal overload was found. (J Prosthet Dent 2012;108:298-303)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed at reporting a clinical and surgical case of bilateral coronoidectomy, using an intraoral approach. The patient is a 26-year-old man, who sought attendance complaining of a gradual reduction of his oral opening in the past 3 years; however, he had an aggravation in the last 2 months. After clinical examination and imaging evaluation, the diagnosis of coronoid process hyperplasia was confirmed, and the surgical treatment was proposed. Under general anesthesia, with nasotracheal intubation guided by a nasofiberendoscope, using an intraoral approach, the bilateral coronoidectomy was performed. In the immediate postoperative period, an increase of the buccal opening measured 29 mm, representing an enhancement of 11 mm, and in the 30th postoperative day, it measured 31.12 mm. During the clinical follow-up period, a reestablishment of the mandibular movements was observed. Therefore, coronoidectomy by an intraoral approach and the physiotherapy performed in the postoperative period were efficient procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tendency of displacement of the supporting structures of the distal extension removable partial denture (DERPD) associated to the implant with different inclinations of alveolar ridge and implant localizations through a two-dimensional finite-element method. Sixteen mandibular models were fabricated, presenting horizontal, distally descending, distally ascending, or descending-ascending ridges. All models presented the left canine and were rehabilitated with conventional DERPD or implant-retained prosthesis with the ERA system. The models were obtained by the AutoCAD software and transferred to the finite-element software ANSYS 9.0 for analysis. A force of 50 N was applied on the cusp tips of the teeth, with 5 points of loading of 10 N. The results were visualized by displacement maps. For all ridge inclinations, the assembly of the DERPD with distal plate retained by an anterior implant exhibited the lowest requisition of the supporting structures. The highest tendency of displacement occurred in the model with distally ascending ridge with incisal rest. It was concluded that the association of the implant decreased the displacement of the DERPD, and the anterior positioning of the implant associated to the DERPD with the distal plate preserved the supporting structures for all ridges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to use two-dimensional finite element method to evaluate the displacement and stress distribution transmitted by a distal extension removable partial denture (DERPD) associated with an implant placed at different inclinations (0, 5, 15, and 30 degrees) in the second molar region of the edentulous mandible ridge. Six hemimandibular models were created: model A, only with the presence of the natural tooth 33; model B, similar to model A, with the presence of a conventional DERPD replacing the missing teeth; model C, similar to the previous model, with a straight implant (0 degrees) in the distal region of the ridge, under the denture base; model D, similar to model C, with the implant angled at 5 degrees in the mesial direction; model E, similar to model C, with the implant angled at 15 degrees in the mesial direction; and model F, similar to ME, with the implant angled at 30 degrees in the mesial direction. The models were created with the use of the AutoCAD 2000 program (Autodesk, Inc, San Rafael, CA) and processed for finite element analysis by the ANSYS 8.0 program (Swanson Analysis Systems, Houston, PA). The force applied was vertical of 50 N on each cusp tip. The results showed that the introduction of the RPD overloaded the supporting structures of the RPD and that the introduction of the implant helped to relieve the stresses of the mucosa alveolar, cortical bone, and trabecular bone. The best stress distribution occurred in model D with the implant angled at 5 degrees. The use of an implant as a support decreased the displacement of alveolar mucosa for all inclinations simulated. The stress distribution transmitted by the DERPD to the supporting structures was improved by the use of straight or slightly inclined implants. According to the displacement analysis and von Mises stress, it could be expected that straight or slightly inclined implants do not represent biomechanical risks to use.