1000 resultados para Madrid Protocol


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study the benefits of a low-dose stimulation (LDS) protocol with purified urinary follicle-stimulating hormone in patients with polycystic ovaries who have presented previously with a very high ovarian response to a standard hMG stimulation. DESIGN: Cohort study. SETTING: Fertility center in a university hospital. PATIENT(S): Sixty-one patients involved in an IVF/ICSI program from January 1995 to December 1996. INTERVENTION(S): The patients were first stimulated with a standard protocol using hMG and presented with a very high ovarian response. These patients were then stimulated a second time using a low-dose protocol. Cryopreserved embryos were transferred in later artificial or natural cycles until to December 1999. MAIN OUTCOME MEASURE(S): Number of gonadotropin ampules; estradiol level on the day of ovulation induction; follicles, oocytes, and cryopreserved zygotes; fertilization, implantation, and pregnancy rates; and number of ovarian hyperstimulation syndromes (OHSS). RESULT(S): The number of ampules used, the estradiol level reached, and the number of oocytes obtained were significantly lower under the LDS than the standard protocol. High implantation (21.8%) and clinical pregnancy (38.4%) rates were obtained after LDS. The cumulated deliveries per cycle started and per patient were, respectively, 41.6% and 52.5%. Five patients suffered OHSS with the standard protocol, and none with the LDS. CONCLUSION(S): The LDS protocol offers a safe and efficient treatment for patients who present with echographic polycystic ovaries and are at risk of an excessive ovarian response to standard IVF stimulation protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purposes of this study were to characterize the performance of a 3-dimensional (3D) ordered-subset expectation maximization (OSEM) algorithm in the quantification of left ventricular (LV) function with (99m)Tc-labeled agent gated SPECT (G-SPECT), the QGS program, and a beating-heart phantom and to optimize the reconstruction parameters for clinical applications. METHODS: A G-SPECT image of a dynamic heart phantom simulating the beating left ventricle was acquired. The exact volumes of the phantom were known and were as follows: end-diastolic volume (EDV) of 112 mL, end-systolic volume (ESV) of 37 mL, and stroke volume (SV) of 75 mL; these volumes produced an LV ejection fraction (LVEF) of 67%. Tomographic reconstructions were obtained after 10-20 iterations (I) with 4, 8, and 16 subsets (S) at full width at half maximum (FWHM) gaussian postprocessing filter cutoff values of 8-15 mm. The QGS program was used for quantitative measurements. RESULTS: Measured values ranged from 72 to 92 mL for EDV, from 18 to 32 mL for ESV, and from 54 to 63 mL for SV, and the calculated LVEF ranged from 65% to 76%. Overall, the combination of 10 I, 8 S, and a cutoff filter value of 10 mm produced the most accurate results. The plot of the measures with respect to the expectation maximization-equivalent iterations (I x S product) revealed a bell-shaped curve for the LV volumes and a reverse distribution for the LVEF, with the best results in the intermediate range. In particular, FWHM cutoff values exceeding 10 mm affected the estimation of the LV volumes. CONCLUSION: The QGS program is able to correctly calculate the LVEF when used in association with an optimized 3D OSEM algorithm (8 S, 10 I, and FWHM of 10 mm) but underestimates the LV volumes. However, various combinations of technical parameters, including a limited range of I and S (80-160 expectation maximization-equivalent iterations) and low cutoff values (< or =10 mm) for the gaussian postprocessing filter, produced results with similar accuracies and without clinically relevant differences in the LV volumes and the estimated LVEF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selecció de textos presentáis pels ponents espanyols al segon Congreso Internacional de Bibliotecas y Bibliografía, organitzat per I'IFLA i celebrat a Madrid i Barcelona el maig del 1935. Precedeix els textos una introducció histórica sob,re el desenvolupament i continguts generals del Congrés.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The purpose of the optic nerve sheath diameter (ONSD) research group project is to establish an individual patient-level database from high quality studies of ONSD ultrasonography for the detection of raised intracranial pressure (ICP), and to perform a systematic review and an individual patient data meta-analysis (IPDMA), which will provide a cutoff value to help physicians making decisions and encourage further research. Previous meta-analyses were able to assess the diagnostic accuracy of ONSD ultrasonography in detecting raised ICP but failed to determine a precise cutoff value. Thus, the ONSD research group was founded to synthesize data from several recent studies on the subject and to provide evidence on the diagnostic accuracy of ONSD ultrasonography in detecting raised ICP. METHODS: This IPDMA will be conducted in different phases. First, we will systematically search for eligible studies. To be eligible, studies must have compared ONSD ultrasonography to invasive intracranial devices, the current reference standard for diagnosing raised ICP. Subsequently, we will assess the quality of studies included based on the QUADAS-2 tool, and then collect and validate individual patient data. The objectives of the primary analyses will be to assess the diagnostic accuracy of ONSD ultrasonography and to determine a precise cutoff value for detecting raised ICP. Secondly, we will construct a logistic regression model to assess whether patient and study characteristics influence diagnostic accuracy. DISCUSSION: We believe that this IPD MA will provide the most reliable basis for the assessment of diagnostic accuracy of ONSD ultrasonography for detecting raised ICP and to provide a cutoff value. We also hope that the creation of the ONSD research group will encourage further study. TRIAL REGISTRATION: PROSPERO registration number: CRD42012003072.