981 resultados para MULTICENTER TRIAL
Resumo:
PURPOSE: The purpose of this analysis was to investigate trastuzumab-associated cardiac adverse effects in breast cancer patients after completion of (neo)adjuvant chemotherapy with or without radiotherapy. PATIENTS AND METHODS: The Herceptin Adjuvant (HERA) trial is a three-group, multicenter, open-label randomized trial that compared 1 or 2 years of trastuzumab given once every 3 weeks with observation in patients with HER-2-positive breast cancer. Only patients who after completion of (neo)adjuvant chemotherapy with or without radiotherapy had normal left ventricular ejection fraction (LVEF > or = 55%) were eligible. A repeat LVEF assessment was performed in case of cardiac dysfunction. RESULTS: Data were available for 1,693 patients randomly assigned to 1 year trastuzumab and 1,693 patients randomly assigned to observation. The incidence of trastuzumab discontinuation due to cardiac disorders was low (4.3%). The incidence of cardiac end points was higher in the trastuzumab group compared with observation (severe congestive heart failure [CHF], 0.60% v 0.00%; symptomatic CHF, 2.15% v 0.12%; confirmed significant LVEF drops, 3.04% v 0.53%). Most patients with cardiac dysfunction recovered in fewer than 6 months. Patients with trastuzumab-associated cardiac dysfunction were treated with higher cumulative doses of doxorubicin (287 mg/m(2) v 257 mg/m(2)) or epirubicin (480 mg/m(2) v 422 mg/m(2)) and had a lower screening LVEF and a higher body mass index. CONCLUSION: Given the clear benefit in disease-free survival, the low incidence of cardiac adverse events, and the suggestion that cardiac dysfunction might be reversible, adjuvant trastuzumab should be considered for treatment of breast cancer patients who fulfill the HERA trial eligibility criteria.
Resumo:
BACKGROUND: To determine the activity and tolerability of adding cetuximab to the oxaliplatin and capecitabine (XELOX) combination in first-line treatment of metastatic colorectal cancer (MCC). PATIENTS AND METHODS: In a multicenter two-arm phase II trial, patients were randomized to receive oxaliplatin 130 mg/m(2) on day 1 and capecitabine 1000 mg/m(2) twice daily on days 1-14 every 3 weeks alone or in combination with standard dose cetuximab. Treatment was limited to a maximum of six cycles. RESULTS: Seventy-four patients with good performance status entered the trial. Objective partial response rates after external review and radiological confirmation were 14% and 41% in the XELOX and in the XELOX + Cetuximab arm, respectively. Stable disease has been observed in 62% and 35% of the patients, with 76% disease control in both arms. Cetuximab led to skin rash in 65% of the patients. The median overall survival was 16.5 months for arm A and 20.5 months for arm B. The median time to progression was 5.8 months for arm A and 7.2 months for arm B. CONCLUSION: Differences in response rates between the treatment arms indicate that cetuximab may improve outcome with XELOX. The correct place of the cetuximab, oxaliplatin and fluoropyrimidine combinations in first-line treatment of MCC has to be assessed in phase III trials.
Resumo:
STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation. PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function. MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05). RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types. CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.
Resumo:
BACKGROUND AND PURPOSE Mechanical thrombectomy using stent retriever devices have been advocated to increase revascularization in intracranial vessel occlusion. We present the results of a large prospective study on the use of the Solitaire Flow Restoration in patients with acute ischemic stroke. METHODS Solitaire Flow Restoration Thrombectomy for Acute Revascularization was an international, multicenter, prospective, single-arm study of Solitaire Flow Restoration thrombectomy in patients with large vessel anterior circulation strokes treated within 8 hours of symptom onset. Strict criteria for site selection were applied. The primary end point was the revascularization rate (thrombolysis in cerebral infarction ≥2b) of the occluded vessel as determined by an independent core laboratory. The secondary end point was the rate of good functional outcome (defined as 90-day modified Rankin scale, 0-2). RESULTS A total of 202 patients were enrolled across 14 comprehensive stroke centers in Europe, Canada, and Australia. The median age was 72 years, 60% were female patients. The median National Institute of Health Stroke Scale was 17. Most proximal intracranial occlusion was the internal carotid artery in 18%, and the middle cerebral artery in 82%. Successful revascularization was achieved in 79.2% of patients. Device and procedure-related severe adverse events were found in 7.4%. Favorable neurological outcome was found in 57.9%. The mortality rate was 6.9%. Any intracranial hemorrhagic transformation was found in 18.8% of patients, 1.5% were symptomatic. CONCLUSIONS In this single-arm study, treatment with the Solitaire Flow Restoration device in intracranial anterior circulation occlusions results in high rates of revascularization, low risk of clinically relevant procedural complications, and good clinical outcomes in combination with low mortality at 90 days. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.
Resumo:
BACKGROUND In patients with acute pulmonary embolism, systemic thrombolysis improves right ventricular (RV) dilatation, is associated with major bleeding, and is withheld in many patients at risk. This multicenter randomized, controlled trial investigated whether ultrasound-assisted catheter-directed thrombolysis (USAT) is superior to anticoagulation alone in the reversal of RV dilatation in intermediate-risk patients. METHODS AND RESULTS Fifty-nine patients (63±14 years) with acute main or lower lobe pulmonary embolism and echocardiographic RV to left ventricular dimension (RV/LV) ratio ≥1.0 were randomized to receive unfractionated heparin and an USAT regimen of 10 to 20 mg recombinant tissue plasminogen activator over 15 hours (n=30; USAT group) or unfractionated heparin alone (n=29; heparin group). Primary outcome was the difference in the RV/LV ratio from baseline to 24 hours. Safety outcomes included death, major and minor bleeding, and recurrent venous thromboembolism at 90 days. In the USAT group, the mean RV/LV ratio was reduced from 1.28±0.19 at baseline to 0.99±0.17 at 24 hours (P<0.001); in the heparin group, mean RV/LV ratios were 1.20±0.14 and 1.17±0.20, respectively (P=0.31). The mean decrease in RV/LV ratio from baseline to 24 hours was 0.30±0.20 versus 0.03±0.16 (P<0.001), respectively. At 90 days, there was 1 death (in the heparin group), no major bleeding, 4 minor bleeding episodes (3 in the USAT group and 1 in the heparin group; P=0.61), and no recurrent venous thromboembolism. CONCLUSIONS In patients with pulmonary embolism at intermediate risk, a standardized USAT regimen was superior to anticoagulation with heparin alone in reversing RV dilatation at 24 hours, without an increase in bleeding complications. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01166997.
Resumo:
Background Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents (DES) aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt chromium DES with silicon carbide coating releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) in an all-comers patient population. Design The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer SES or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least one lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary endpoint target lesion failure (TLF) is a composite of cardiac death, target-vessel myocardial infarction, and clinically-driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for non-inferiority, inclusion of 2,060 patients would provide 80% power to detect non-inferiority of the biodegradable polymer SES compared with the durable polymer EES at a one-sided type I error of 0.05. Clinical follow-up will be continued through five years. Conclusion The BIOSCIENCE trial will determine whether the biodegradable polymer SES is non-inferior to the durable polymer EES with respect to TLF.
Resumo:
OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).
Resumo:
BACKGROUND Biodegradable polymers for release of antiproliferative drugs from drug-eluting stents aim to improve vascular healing. We assessed noninferiority of a novel ultrathin strut drug-eluting stent releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) compared with the durable polymer Xience Prime everolimus-eluting stent (X-EES) in terms of the primary end point in-stent late lumen loss at 9 months. METHODS AND RESULTS A total of 452 patients were randomly assigned 2:1 to treatment with O-SES (298 patients, 332 lesions) or X-EES (154 patients, 173 lesions) in a multicenter, noninferiority trial. The primary end point was in-stent late loss at 9 months. O-SES was noninferior to X-EES for the primary end point (0.10±0.32 versus 0.11±0.29 mm; difference=0.00063 mm; 95% confidence interval, -0.06 to 0.07; Pnoninferiority<0.0001). Clinical outcome showed similar rates of target-lesion failure at 1 year (O-SES 6.5% versus X-EES 8.0%; hazard ratio=0.82; 95% confidence interval, 0.40-1.68; log-rank test: P=0.58) without cases of stent thrombosis. A subgroup of patients (n=55) underwent serial optical coherence tomography at 9 months, which demonstrated similar neointimal thickness among lesions allocated to O-SES and X-EES (0.10±0.04 mm versus 0.11±0.04 mm; -0.01 [-0.04, -0.01]; P=0.37). Another subgroup of patients (n=56) underwent serial intravascular ultrasound at baseline and 9 months indicating a potential difference in neointimal area at follow-up (O-SES, 0.16±0.33 mm(2) versus X-EES, 0.43±0.56 mm(2); P=0.04). CONCLUSIONS Compared with durable polymer X-EES, novel biodegradable polymer-based O-SES was found noninferior for the primary end point in-stent late lumen loss at 9 months. Clinical event rates were comparable without cases of stent thrombosis throughout 1 year of follow-up. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01356888.
Resumo:
While bisphosphonates reduce fracture risk over 3 to 5 years, the optimal duration of treatment is uncertain. In a randomized extension study (E1) of the Health Outcomes and Reduced Incidence with Zoledronic Acid Once Yearly - Pivotal Fracture Trial (HORIZON-PFT), zoledronic acid (ZOL) 5 mg annually for 6 years showed maintenance of bone mineral density (BMD), decrease in morphometric vertebral fractures, and a modest reduction in bone turnover markers (BTMs) compared with discontinuation after 3 years. To investigate the longer-term efficacy and safety of ZOL, a second extension (E2) was conducted to 9 years in which women on ZOL for 6 years in E1 were randomized to either ZOL (Z9) or placebo (Z6P3) for 3 additional years. In this multicenter, randomized, double-blind study, 190 women were randomized to Z9 (n=95) and Z6P3 (n=95). The primary endpoint was change in total hip BMD at year 9 vs. year 6 in Z9 compared with Z6P3. Other secondary endpoints included fractures, BTMs, and safety. From year 6 to 9, the mean change in total hip BMD was -0.54% in Z9 vs. -1.31% in Z6P3 (difference 0.78%; 95% confidence interval [CI]: -0.37%, 1.93%; p=0.183). BTMs showed small, non-significant increases in those who discontinued after 6 years compared with those who continued for 9 years. The number of fractures was low and did not significantly differ by treatment. While generally safe, there was a small increase in cardiac arrhythmias (combined serious and non-serious) in the Z9 group but no significant imbalance in other safety parameters. The results suggest almost all patients who have received six annual ZOL infusions can stop medication for up to 3 years with apparent maintenance of benefits. This article is protected by copyright. All rights reserved.
Resumo:
IMPORTANCE High-dose immunosuppressive therapy and autologous hematopoietic stem cell transplantation (HSCT) have shown efficacy in systemic sclerosis in phase 1 and small phase 2 trials. OBJECTIVE To compare efficacy and safety of HSCT vs 12 successive monthly intravenous pulses of cyclophosphamide. DESIGN, SETTING, AND PARTICIPANTS The Autologous Stem Cell Transplantation International Scleroderma (ASTIS) trial, a phase 3, multicenter, randomized (1:1), open-label, parallel-group, clinical trial conducted in 10 countries at 29 centers with access to a European Group for Blood and Marrow Transplantation-registered transplant facility. From March 2001 to October 2009, 156 patients with early diffuse cutaneous systemic sclerosis were recruited and followed up until October 31, 2013. INTERVENTIONS HSCT vs intravenous pulse cyclophosphamide. MAIN OUTCOMES AND MEASURES The primary end point was event-free survival, defined as time from randomization until the occurrence of death or persistent major organ failure. RESULTS A total of 156 patients were randomly assigned to receive HSCT (n = 79) or cyclophosphamide (n = 77). During a median follow-up of 5.8 years, 53 events occurred: 22 in the HSCT group (19 deaths and 3 irreversible organ failures) and 31 in the control group (23 deaths and 8 irreversible organ failures). During the first year, there were more events in the HSCT group (13 events [16.5%], including 8 treatment-related deaths) than in the control group (8 events [10.4%], with no treatment-related deaths). At 2 years, 14 events (17.7%) had occurred cumulatively in the HSCT group vs 14 events (18.2%) in the control group; at 4 years, 15 events (19%) had occurred cumulatively in the HSCT group vs 20 events (26%) in the control group. Time-varying hazard ratios (modeled with treatment × time interaction) for event-free survival were 0.35 (95% CI, 0.16-0.74) at 2 years and 0.34 (95% CI, 0.16-0.74) at 4 years. CONCLUSIONS AND RELEVANCE Among patients with early diffuse cutaneous systemic sclerosis, HSCT was associated with increased treatment-related mortality in the first year after treatment. However, HCST conferred a significant long-term event-free survival benefit. TRIAL REGISTRATION isrctn.org Identifier: ISRCTN54371254.
Resumo:
PURPOSE This study assessed whether a cycle of "routine" therapeutic drug monitoring (TDM) for imatinib dosage individualization, targeting an imatinib trough plasma concentration (C min) of 1,000 ng/ml (tolerance: 750-1,500 ng/ml), could improve clinical outcomes in chronic myelogenous leukemia (CML) patients, compared with TDM use only in case of problems ("rescue" TDM). METHODS Imatinib concentration monitoring evaluation was a multicenter randomized controlled trial including adult patients in chronic or accelerated phase CML receiving imatinib since less than 5 years. Patients were allocated 1:1 to "routine TDM" or "rescue TDM." The primary endpoint was a combined outcome (failure- and toxicity-free survival with continuation on imatinib) over 1-year follow-up, analyzed in intention-to-treat (ISRCTN31181395). RESULTS Among 56 patients (55 evaluable), 14/27 (52 %) receiving "routine TDM" remained event-free versus 16/28 (57 %) "rescue TDM" controls (P = 0.69). In the "routine TDM" arm, dosage recommendations were correctly adopted in 14 patients (median C min: 895 ng/ml), who had fewer unfavorable events (28 %) than the 13 not receiving the advised dosage (77 %; P = 0.03; median C min: 648 ng/ml). CONCLUSIONS This first target concentration intervention trial could not formally demonstrate a benefit of "routine TDM" because of small patient number and surprisingly limited prescriber's adherence to dosage recommendations. Favorable outcomes were, however, found in patients actually elected for target dosing. This study thus shows first prospective indication for TDM being a useful tool to guide drug dosage and shift decisions. The study design and analysis provide an interesting paradigm for future randomized TDM trials on targeted anticancer agents.
Resumo:
BACKGROUND Drug-eluting balloons (DEB) may reduce infrapopliteal restenosis and reintervention rates versus percutaneous transluminal angioplasty (PTA) and improve wound healing/limb preservation. OBJECTIVES The goal of this clinical trial was to assess the efficacy and safety of IN.PACT Amphirion drug-eluting balloons (IA-DEB) compared to PTA for infrapopliteal arterial revascularization in patients with critical limb ischemia (CLI). METHODS Within a prospective, multicenter, randomized, controlled trial with independent clinical event adjudication and angiographic and wound core laboratories 358 CLI patients were randomized 2:1 to IA-DEB or PTA. The 2 coprimary efficacy endpoints through 12 months were clinically driven target lesion revascularization (CD-TLR) and late lumen loss (LLL). The primary safety endpoint through 6 months was a composite of all-cause mortality, major amputation, and CD-TLR. RESULTS Clinical characteristics were similar between the 2 groups. Significant baseline differences between the IA-DEB and PTA arms included mean lesion length (10.2 cm vs. 12.9 cm; p = 0.002), impaired inflow (40.7% vs. 28.8%; p = 0.035), and previous target limb revascularization (32.2% vs. 21.8%; p = 0.047). Primary efficacy results of IA-DEB versus PTA were CD-TLR of 9.2% versus 13.1% (p = 0.291) and LLL of 0.61 ± 0.78 mm versus 0.62 ± 0.78 mm (p = 0.950). Primary safety endpoints were 17.7% versus 15.8% (p = 0.021) and met the noninferiority hypothesis. A safety signal driven by major amputations through 12 months was observed in the IA-DEB arm versus the PTA arm (8.8% vs. 3.6%; p = 0.080). CONCLUSIONS In patients with CLI, IA-DEB had comparable efficacy to PTA. While primary safety was met, there was a trend towards an increased major amputation rate through 12 months compared to PTA. (Study of IN.PACT Amphirion™ Drug Eluting Balloon vs. Standard PTA for the Treatment of Below the Knee Critical Limb Ischemia [INPACT-DEEP]; NCT00941733).
Resumo:
Treatment allocation by epidermal growth factor receptor mutation status is a new standard in patients with metastatic nonesmall-cell lung cancer. Yet, relatively few modern chemotherapy trials were conducted in patients characterized by epidermal growth factor receptor wild type. We describe the results of a multicenter phase II trial, testing in parallel 2 novel combination therapies, predefined molecular markers, and tumor rebiopsy at progression. Objective: The goal was to demonstrate that tailored therapy, according to tumor histology and epidermal growth factor receptor (EGFR) mutation status, and the introduction of novel drug combinations in the treatment of advanced nonesmall-cell lung cancer are promising for further investigation. Methods: We conducted a multicenter phase II trial with mandatory EGFR testing and 2 strata. Patients with EGFR wild type received 4 cycles of bevacizumab, pemetrexed, and cisplatin, followed by maintenance with bevacizumab and pemetrexed until progression. Patients with EGFR mutations received bevacizumab and erlotinib until progression. Patients had computed tomography scans every 6 weeks and repeat biopsy at progression. The primary end point was progression-free survival (PFS) ≥ 35% at 6 months in stratum EGFR wild type; 77 patients were required to reach a power of 90% with an alpha of 5%. Secondary end points were median PFS, overall survival, best overall response rate (ORR), and tolerability. Further biomarkers and biopsy at progression were also evaluated. Results: A total of 77 evaluable patients with EGFR wild type received an average of 9 cycles (range, 1-25). PFS at 6 months was 45.5%, median PFS was 6.9 months, overall survival was 12.1 months, and ORR was 62%. Kirsten rat sarcoma oncogene mutations and circulating vascular endothelial growth factor negatively correlated with survival, but thymidylate synthase expression did not. A total of 20 patients with EGFR mutations received an average of 16.
Resumo:
PURPOSE To determine the safety and efficacy of AL-8309B (tandospirone) in the management of patients with geographic atrophy (GA) secondary to age-related macular degeneration (AMD) and obtain standardized data on GA lesion growth progression. DESIGN Prospective, controlled, double-masked, randomized, multicenter phase 3 clinical trial. METHODS Setting: 48 clinical sites. PATIENTS Patients with GA associated with AMD were enrolled. All patients were followed for a minimum of 30 months, and up to 36 months. Intervention Procedures: Patients were randomized (1:1:1) to receive AL-8309B ophthalmic solution 1.0%, 1.75%, or vehicle, administered as a twice-daily topical ocular drop. MAIN OUTCOME MEASURES The primary efficacy endpoint was mean annualized lesion enlargement from baseline as assessed with fundus autofluorescence (FAF) imaging. RESULTS A total of 768 eyes of 768 patients were enrolled and treated with AL-8309B 1.0% (N=250), AL-8309B 1.75% (N=258), or vehicle (N= 260). An increase in mean lesion size was observed in both the AL-8309B and vehicle treatment groups, and growth rates were similar in all treatment groups. Annualized lesion growth rates were 1.73, 1.76 and 1.71 mm(2) for AL-8309B 1.0%, AL-8309B 1.75%, and vehicle, respectively. CONCLUSIONS AL-8309B 1.0% and 1.75% did not affect lesion growth in eyes with GA secondary to AMD. There were no clinically relevant safety issues identified for AL-8309B. The large natural history dataset from this study is a valuable repository for future comparisons.
Resumo:
BACKGROUND Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium metal alloy platform with an ultrathin bioabsorbable Poly(D,L-lactide-co-glycolide) abluminal everolimus-eluting polymer. We performed a multicenter, randomized controlled trial for regulatory approval to determine noninferiority of the SYNERGY stent to the durable polymer PROMUS Element Plus everolimus-eluting stent. METHODS AND RESULTS Patients (n=1684) scheduled to undergo percutaneous coronary intervention for non-ST-segment-elevation acute coronary syndrome or stable coronary artery disease were randomized to receive either the SYNERGY stent or the PROMUS Element Plus stent. The primary end point of 12-month target lesion failure was observed in 6.7% of SYNERGY and 6.5% PROMUS Element Plus treated subjects by intention-to-treat (P=0.83 for difference; P=0.0005 for noninferiority), and 6.4% in both the groups by per-protocol analysis (P=0.0003 for noninferiority). Clinically indicated revascularization of the target lesion or definite/probable stent thrombosis were observed in 2.6% versus 1.7% (P=0.21) and 0.4% versus 0.6% (P=0.50) of SYNERGY versus PROMUS Element Plus-treated subjects, respectively. CONCLUSIONS In this randomized trial, the SYNERGY bioabsorbable polymer everolimus-eluting stent was noninferior to the PROMUS Element Plus everolimus-eluting stent with respect to 1-year target lesion failure. These data support the relative safety and efficacy of SYNERGY in a broad range of patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01665053.