998 resultados para MP3 (Audio coding standard)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subterranean clover stunt disease is an economically important aphid-borne virus disease affecting certain pasture and grain legumes in Australia. The virus associated with the disease, subterranean clover stunt virus (SCSV), was previously found to be representative of a new type of single-stranded DNA virus. Analysis of the virion DNA and restriction mapping of double-stranded cDNA synthesized from virion DNA suggested that SCSV has a segmented genome composed of 3 or 4 different species of circular ssDNA each of about 850-880 nucleotides. To further investigate the complexity of the SCSV genome, we have isolated the replicative form DNA from infected pea and from it prepared putative full-length clones representing the SCSV genome segments. Analysis of these clones by restriction mapping indicated that clones representing at least 4 distinct genomic segments were obtained. This method is thus suitable for generating an extensive genomic library of novel ssDNA viruses containing multiple genome segments such as SCSV and banana bunchy top virus. The N-terminal amino acid sequence and amino acid composition of the coat protein of SCSV were determined. Comparison of the amino acid sequence with partial DNA sequence data, and the distinctly different restriction maps obtained for the full-length clones suggested that only one of these clones contained the coat protein gene. The results confirmed that SCSV has a functionally divided genome composed of several distinct ssDNA circles each of about 1 kb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irradiance profile around the receiver tube (RT) of a parabolic trough collector (PTC) is a key effect of optical performance that affects the overall energy performance of the collector. Thermal performance evaluation of the RT relies on the appropriate determination of the irradiance profile. This article explains a technique in which empirical equations were developed to calculate the local irradiance as a function of angular location of the RT of a standard PTC using a vigorously verified Monte Carlo ray tracing model. A large range of test conditions including daily normal insolation, spectral selective coatings and glass envelop conditions were selected from the published data by Dudley et al. [1] for the job. The R2 values of the equations are excellent that vary in between 0.9857 and 0.9999. Therefore, these equations can be used confidently to produce realistic non-uniform boundary heat flux profile around the RT at normal incidence for conjugate heat transfer analyses of the collector. Required values in the equations are daily normal insolation, and the spectral selective properties of the collector components. Since the equations are polynomial functions, data processing software can be employed to calculate the flux profile very easily and quickly. The ultimate goal of this research is to make the concentrating solar power technology cost competitive with conventional energy technology facilitating its ongoing research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Occupational exposures of healthcare workers tend to occur because of inconsistent compliance with standard precautions. Also, incidence of occupational exposure is underreported among operating room personnel. The purpose of this project was to develop national estimates for compliance with standard precautions and occupational exposure reporting practices among operating room nurses in Australia. Data was obtained utilizing a 96-item self-report survey. The Standard Precautions and Occupational Exposure Reporting survey was distributed anonymously to 500 members of the Australian College of Operating Room Nurses. The Health Belief Model was the theoretical framework used to guide the analysis of data. Data was analysed to examine relationships between specific constructs of the Health Belief Model to identify factors that might influence the operating room nurse to undertake particular health behaviours to comply with standard precautions and occupational exposure reporting. Results of the study revealed compliance rates of 55.6% with double gloving, 59.1% with announcing sharps transfers, 71.9% with using a hands-free sharps pass technique, 81.9% with no needle recapping and 92.0% with adequate eye protection. Although 31.6% of respondents indicated receiving an occupational exposure in the past 12 months, only 82.6% of them reported their exposures. The results of this study provide national estimates of compliance with standard precautions and occupational exposure reporting among operating room nurses in Australia. These estimates can now be used as support for the development and implementation of measures to improve practices in order to reduce occupational exposures and, ultimately, disease transmission rates among this high-risk group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Occupational exposures of health care workers occur because of inconsistent compliance with standard precautions. The purpose of this study was to develop national estimates of compliance with standard precautions and occupational exposure reporting among operating room nurses (specifically, scrub nurses) in Australia and to assess variables that influence compliance. Methods A descriptive correlation design was used to investigate relationships between variables and compliance, using a theoretical framework, the Health Belief Model, to give meaning to the variables. Data collection was done through mail-out surveys to members of the Australian College of Operating Room Nurses. Results This article reports the results of compliance with the following 2 specific self-protective behaviors: double-gloving and wearing adequate eye protection. Mean compliance rates were 55.6% with always double-gloving during surgical procedures and 92% with always wearing adequate eye protection. In addition, the variable that had the most influence on compliance was the perception of barriers to compliance, specifically, that adhering to standard precautions interfered with duties. Conclusion These results have implications for the development of multifaceted perioperative infection control programs, including strategies for prevention, education, and policy development, to improve practices aimed at reducing occupational exposures among this high-risk group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malignant Pleural Mesothelioma (MPM) is an aggressive cancer that is often diagnosed at an advanced stage and is characterized by a long latency period (20-40 years between initial exposure and diagnosis) and prior exposure to asbestos. Currently accurate diagnosis of MPM is difficult due to the lack of sensitive biomarkers and despite minor improvements in treatment, median survival rates do not exceed 12 months. Accumulating evidence suggests that aberrant expression of long non-coding RNAs (lncRNAs) play an important functional role in cancer biology. LncRNAs are a class of recently discovered non-protein coding RNAs >200 nucleotides in length with a role in regulating transcription. Here we used NCode long noncoding microarrays to identify differentially expressed lncRNAs potentially involved in MPM pathogenesis. High priority candidate lncRNAs were selected on the basis of statistical (P<0.05) and biological significance (>3-fold difference). Expression levels of 9 candidate lncRNAs were technically validated using RT-qPCR, and biologically validated in three independent test sets: (1) 57 archived MPM tissues obtained from extrapleural pneumonectomy patients, (2) 15 cryopreserved MPM and 3 benign pleura, and (3) an extended panel of 10 MPM cell lines. RT-qPCR analysis demonstrated consistent up-regulation of these lncRNAs in independent datasets. ROC curve analysis showed that two candidates were able to separate benign pleura and MPM with high sensitivity and specificity, and were associated with nodal metastases and survival following induction chemotherapy. These results suggest that lncRNAs have potential to serve as biomarkers in MPM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molecular mechanisms involved in non‑small cell lung cancer tumourigenesis are largely unknown; however, recent studies have suggested that long non-coding RNAs (lncRNAs) are likely to play a role. In this study, we used public databases to identify an mRNA-like, candidate long non-coding RNA, GHSROS (GHSR opposite strand), transcribed from the antisense strand of the ghrelin receptor gene, growth hormone secretagogue receptor (GHSR). Quantitative real-time RT-PCR revealed higher expression of GHSROS in lung cancer tissue compared to adjacent, non-tumour lung tissue. In common with many long non-coding RNAs, GHSROS is 5' capped and 3' polyadenylated (mRNA-like), lacks an extensive open reading frame and harbours a transposable element. Engineered overexpression of GHSROS stimulated cell migration in the A549 and NCI-H1299 non-small cell lung cancer cell lines, but suppressed cell migration in the Beas-2B normal lung-derived bronchoepithelial cell line. This suggests that GHSROS function may be dependent on the oncogenic context. The identification of GHSROS, which is expressed in lung cancer and stimulates cell migration in lung cancer cell lines, contributes to the growing number of non-coding RNAs that play a role in the regulation of tumourigenesis and metastatic cancer progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental monitoring is becoming critical as human activity and climate change place greater pressures on biodiversity, leading to an increasing need for data to make informed decisions. Acoustic sensors can help collect data across large areas for extended periods making them attractive in environmental monitoring. However, managing and analysing large volumes of environmental acoustic data is a great challenge and is consequently hindering the effective utilization of the big dataset collected. This paper presents an overview of our current techniques for collecting, storing and analysing large volumes of acoustic data efficiently, accurately, and cost-effectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We construct an efficient identity based encryption system based on the standard learning with errors (LWE) problem. Our security proof holds in the standard model. The key step in the construction is a family of lattices for which there are two distinct trapdoors for finding short vectors. One trapdoor enables the real system to generate short vectors in all lattices in the family. The other trapdoor enables the simulator to generate short vectors for all lattices in the family except for one. We extend this basic technique to an adaptively-secure IBE and a Hierarchical IBE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Network coding is a method for achieving channel capacity in networks. The key idea is to allow network routers to linearly mix packets as they traverse the network so that recipients receive linear combinations of packets. Network coded systems are vulnerable to pollution attacks where a single malicious node floods the network with bad packets and prevents the receiver from decoding correctly. Cryptographic defenses to these problems are based on homomorphic signatures and MACs. These proposals, however, cannot handle mixing of packets from multiple sources, which is needed to achieve the full benefits of network coding. In this paper we address integrity of multi-source mixing. We propose a security model for this setting and provide a generic construction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The notion of certificateless public-key encryption (CL-PKE) was introduced by Al-Riyami and Paterson in 2003 that avoids the drawbacks of both traditional PKI-based public-key encryption (i.e., establishing public-key infrastructure) and identity-based encryption (i.e., key escrow). So CL-PKE like identity-based encryption is certificate-free, and unlike identity-based encryption is key escrow-free. In this paper, we introduce simple and efficient CCA-secure CL-PKE based on (hierarchical) identity-based encryption. Our construction has both theoretical and practical interests. First, our generic transformation gives a new way of constructing CCA-secure CL-PKE. Second, instantiating our transformation using lattice-based primitives results in a more efficient CCA-secure CL-PKE than its counterpart introduced by Dent in 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An encryption scheme is non-malleable if giving an encryption of a message to an adversary does not increase its chances of producing an encryption of a related message (under a given public key). Fischlin introduced a stronger notion, known as complete non-malleability, which requires attackers to have negligible advantage, even if they are allowed to transform the public key under which the related message is encrypted. Ventre and Visconti later proposed a comparison-based definition of this security notion, which is more in line with the well-studied definitions proposed by Bellare et al. The authors also provide additional feasibility results by proposing two constructions of completely non-malleable schemes, one in the common reference string model using non-interactive zero-knowledge proofs, and another using interactive encryption schemes. Therefore, the only previously known completely non-malleable (and non-interactive) scheme in the standard model, is quite inefficient as it relies on generic NIZK approach. They left the existence of efficient schemes in the common reference string model as an open problem. Recently, two efficient public-key encryption schemes have been proposed by Libert and Yung, and Barbosa and Farshim, both of them are based on pairing identity-based encryption. At ACISP 2011, Sepahi et al. proposed a method to achieve completely non-malleable encryption in the public-key setting using lattices but there is no security proof for the proposed scheme. In this paper we review the mentioned scheme and provide its security proof in the standard model. Our study shows that Sepahi’s scheme will remain secure even for post-quantum world since there are currently no known quantum algorithms for solving lattice problems that perform significantly better than the best known classical (i.e., non-quantum) algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most existing marinas are boat parking/storing and servicing facilities that have been built over a long period of time for the convenience of local boat owners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the problem of increasing the threshold parameter of a secret-sharing scheme after the setup (share distribution) phase, without further communication between the dealer and the shareholders. Previous solutions to this problem require one to start off with a nonstandard scheme designed specifically for this purpose, or to have communication between shareholders. In contrast, we show how to increase the threshold parameter of the standard Shamir secret-sharing scheme without communication between the shareholders. Our technique can thus be applied to existing Shamir schemes even if they were set up without consideration to future threshold increases. Our method is a new positive cryptographic application for lattice reduction algorithms, inspired by recent work on lattice-based list decoding of Reed-Solomon codes with noise bounded in the Lee norm. We use fundamental results from the theory of lattices (geometry of numbers) to prove quantitative statements about the information-theoretic security of our construction. These lattice-based security proof techniques may be of independent interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the design and implementation of a wireless neural telemetry system that enables new experimental paradigms, such as neural recordings during rodent navigation in large outdoor environments. RoSco, short for Rodent Scope, is a small lightweight user-configurable module suitable for digital wireless recording from freely behaving small animals. Due to the digital transmission technology, RoSco has advantages over most other wireless modules of noise immunity and online user-configurable settings. RoSco digitally transmits entire neural waveforms for 14 of 16 channels at 20 kHz with 8-bit encoding which are streamed to the PC as standard USB audio packets. Up to 31 RoSco wireless modules can coexist in the same environment on non-overlapping independent channels. The design has spatial diversity reception via two antennas, which makes wireless communication resilient to fading and obstacles. In comparison with most existing wireless systems, this system has online user-selectable independent gain control of each channel in 8 factors from 500 to 32,000 times, two selectable ground references from a subset of channels, selectable channel grounding to disable noisy electrodes, and selectable bandwidth suitable for action potentials (300 Hz–3 kHz) and low frequency field potentials (4 Hz–3 kHz). Indoor and outdoor recordings taken from freely behaving rodents are shown to be comparable to a commercial wired system in sorting for neural populations. The module has low input referred noise, battery life of 1.5 hours and transmission losses of 0.1% up to a range of 10 m.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim The International Classification of Diseases, version 10, Australian modification (ICD-10-AM) is used to classify diseases in hospital patients in Australia and New Zealand. ICD-10-AM defines malnutrition as ‘[body mass index] BMI <18.5 kg/m2 or unintentional weight loss of ≥5% with evidence of suboptimal intake resulting in subcutaneous fat loss and/or muscle wasting’. The Australasian Nutrition Care Day Survey (ANCDS) is the most comprehensive survey to evaluate malnutrition prevalence in acute care patients from Australian and New Zealand hospitals. This study determined if malnourished participants were assigned malnutrition-related codes according to ICD-10-AM. Methods The ANCDS recruited acute care patients from 56 hospitals. Hospital-based dietitians evaluated participants' nutritional status using BMI and Subjective Global Assessment (SGA). In keeping with the ICD-10-AM definition, malnutrition was defined as BMI <18.5 kg/m2, SGA-B (moderately malnourished) or SGA-C (severely malnourished). After 3 months, in this prospective cohort study, staff members from each hospital's health information/medical records department provided coding results for malnourished participants. Results Malnutrition was prevalent in 30% (n = 869) of the cohort (n = 2976) and a significantly small number of malnourished patients were coded for malnutrition (n = 162, 19%, P < 0.001). In 21 hospitals, none of the malnourished participants were coded. Conclusions This is the largest study to provide a snapshot of malnutrition coding in Australian and New Zealand hospitals. Findings highlight gaps in malnutrition documentation and/or subsequent coding, which could potentially result in significant loss of casemix-related revenue for hospitals. Dietitians must lead the way in developing structured processes for malnutrition identification, documentation and coding.