952 resultados para Lente intraocular multifocal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To report a case of multifocal fibrosclerosis with a nine-year follow up, and to discuss this disease's radiological appearance and management. The disease is a rare systemic disorder of unknown cause characterised by fibrous proliferation involving multiple anatomical sites. Case report: A 50-year-old woman presented with histological findings characterised by similar inflammatory processes involving the meninges, pituitary gland, peritoneum, retroperitoneum and orbits, prompting a search for a common pathophysiology. A diagnosis of multifocal fibrosclerosis was postulated. Symptom improvement was noted after treatment with prednisone and azathioprine. Conclusion: This is the first documented case of involvement of the cochleovestibular nerve in a patient with multifocal fibrosclerosis. The rare association between fibrotic diseases and masses showing various clinical patterns should be kept in mind by otolaryngologists, and imaging performed to investigate for multifocal fibrosclerosis. However, diagnosis can only be confirmed with tissue biopsy and histopathological examination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate alignment of a toric intraocular lens (IOL) is a requisite to achieving the intended reduction in astigmatism at the time of cataract surgery. However, it requires a reasonably clear view of the limbal vascular anatomy, which is sometimes altered by chemosis from a subconjunctival anesthetic injection or a hemorrhage. We describe a technique that can quickly restore vascular anatomy and facilitate toric IOL alignment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To evaluate the ability of multifocal transient pattern electroretinography (mfPERG) to detect neural loss and assess the relationship between mfPERG and visual-field (VF) loss in eyes with chiasmal compression. Methods 23 eyes from 23 patients with temporal VF defects and band atrophy of the optic nerve and 21 controls underwent standard automated perimetry and mfPERG using a stimulus pattern of 19 rectangles, each consisting of 12 squares. The response was determined for the central rectangle, for the nasal and temporal hemifields (eight rectangles each) and for each quadrant (three rectangles) in both patients and controls. Comparisons were made using variance analysis. Correlations between VF and mfPERG measurements were verified by linear regression analysis. Results Mean +/- SD mfPERG amplitudes from the temporal hemifield (0.50 +/- 0.17 and 0.62 +/- 0.32) and temporal quadrants (superior 0.42 +/- 0.21 and 0.52 +/- 0.35, inferior 0.51 +/- 0.23 and 0.74 +/- 0.40) were significantly lower in eyes with band atrophy than in controls (0.78 +/- 0.24, 0.89 +/- 0.28, 0.73 +/- 60.26, 0.96 +/- 0.36, 0.79 +/- 0.26 and 0.91 +/- 0.31, respectively). No significant difference was observed in nasal hemifield measurements. Significant correlations (0.36-0.73) were found between VF relative sensitivity and mfPERG amplitude in different VF sectors. Conclusions mfPERG amplitude measurements clearly differentiate eyes with temporal VF defect from controls. The good correlation between mfPERG amplitudes and the severity of VF defect suggests that mfPERG may be used as an indicator of ganglion cell dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pretendo, neste artigo, abordar um caso de Binswanger privilegiado por Merleau-Ponty. Nesse caso, o filósofo desenvolve a questão do estatuto do sintoma como uma forma de elaboração de vida, mas chega num impasse: como pensar essa elaboração sem que isso nos leve a negar que o sujeito se reestrutura totalmente diante de um impasse? Além do que, o que significa dizer que o sujeito elabora uma nova forma de vida? Veremos como a análise merleau-pontyana da psicanálise é peculiar, levando-o a negar um conceito chave da metapsicologia freudiana: o inconsciente.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Like other vascular tumors, epithelioid hemangioendothelioma (EHE) is multifocal in approximately 50% of cases, and it is unclear whether the separate lesions represent multifocal disease or metastases. We hypothesized that the identification of an identical WWTR1-CAMTA1 rearrangement in different EHEs from the same patient supports the monoclonal origin of EHE. To test our hypothesis, we undertook a molecular analysis of two multicentric EHEs of the liver, including separate tumor samples from each patient. Matherial and Methods: We retrieved two cases of EHE with available tissue for molecular analysis. In both cases, fluorescence in situ hybridization (FISH) was performed to identify the presence of the WWTR1-CAMTA1 rearrangement to confirm the histologic diagnosis of EHE, as previously described. The reverse transcription-polymerase chain reaction (RT-PCR) products were analyzed by electrophoresis and the RT-PCR–amplified products were sequenced using the Sanger method. Results: FISH analysis revealed signal abnormalities in both WWTR1 and CAMTA1. Combined results confirmed the presence of the t(1;3)(1p36.23;3q25.1) translocation in both cases of EHE. Using RT-PCR analysis, we found that the size of the rearranged bands was identical in the different tumors from each patient. The sequence of the fusion gene confirmed a different WWTR1-CAMTA1 rearrangement in each patient, but an identical WWTR1-CAMTA1 rearrangement in the different lesions from each patient. Discussion: Because of its generally indolent clinical course, EHE is commonly classified as a multifocal, rather than metastatic, disease. In this study, we examined two cases of multifocal liver EHE and found an identical WWTR1-CAMTA1 rearrangement in each lesion from the same patient, but not between the two patients. These findings suggest that multifocal EHE arises from metastasis of the same neoplastic clone rather than from the simultaneous formation of multiple neoplastic clones, which supports the monoclonal origin of multifocal EHE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reports on intraocular pressure (IOP) changes at high altitudes have provided inconsistent and even conflicting

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pathogenesis of multifocal motor neuropathy (MMN) has yet to be established. MMN patients often carry anti-GM1 IgM antibodies, suggesting an autoimmune process involving complement. Intravenous immunoglobulin (IVIG) is the first line treatment, but its action mechanism is unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravenous immunoglobulin (IVIG) is the first-line therapy for multifocal motor neuropathy (MMN). This open-label multi-centre study (NCT00701662) assessed the efficacy, safety, and convenience of subcutaneous immunoglobulin (SCIG) in patients with MMN over 6 months, as an alternative to IVIG. Eight MMN patients (42-66 years), on stable IVIG dosing, received weekly SCIG at doses equivalent to previous IVIG using a "smooth transition protocol". Primary efficacy endpoint was the change from baseline to week 24 in muscle strength. Disability, motor function, and health-related quality of life (HRQL) endpoints were also assessed. One patient deteriorated despite dose increase and was withdrawn. Muscle strength, disability, motor function, and health status were unchanged in all seven study completers who rated home treatment as extremely good. Four experienced 18 adverse events, of which only two were moderate. This study suggests that MMN patients with stable clinical course on regular IVIG can be switched to SCIG at the same monthly dose without deterioration and with a sustained overall improvement in HRQL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To observe the excursions of short-term intraocular pressure (IOP) after 20-G pars-plana vitrectomy (ppV).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eye injuries are a large societal problem in both the military and civilian sectors. Eye injury rates are increasing in recent military conflicts, and there are over 1.9 million eye injuries in the United States civilian sector annually. In order to develop a better understanding of eye injury risk, several previous studies have developed eye injury criteria based on projectile characteristics. While these injury criteria have been used to estimate eye injury potential of impact scenarios, they require that the mass, size and velocity of the projectile are known. It is desirable to develop a method to assess the severity of an eye impact in environments where it would be difficult or impossible to determine these projectile characteristics. The current study presents a measurement technique for monitoring intraocular pressure of the eye under impactloading. Through experimental tests with a custom pressure chamber, a subminiature pressure transducer was validated to be thermally stable and suitable for testing in an impact environment.Once validated, the transducer was utilized intraocularly, inserted through the optic nerve, to measure the pressure of the eye during blunt-projectile impacts. A total of 150 impact tests were performed using projectiles ranging from 3.2 mm to 17.5 mm in diameter. Investigation of the relationship between projectile energy and intraocular pressure lead to the identification of at least two distinct trends. Intraocular pressure and normalized energy measurements indicated a different response for penetrating-type globe rupture injuries with smaller diameter (d < 1 cm)projectiles, and blunt-type globe rupture injuries with larger diameter (d > 1 cm) projectiles. Furthermore, regression analysis indicates that relationships exist between intraocular pressureand projectile energy that may allow quantification of eye injury risk based on pressure data, and also that intraocular pressure measurements of impact may lead to a better understanding of thetransition between penetrating and blunt globe rupture injury mechanisms.