961 resultados para Labor insertion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly Labor Force Data report produced by the Iowa Workforce Development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly Labor Force Data report produced by the Iowa Workforce Development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Isolated avulsion fracture at the plantar lateral base of the first metatarsal (M1) is very rare. Case report: A 35 year old overweight woman sustained an eversion strain of her right foot. Despite pain along M1 she was able to continue walking for three days before presenting to her family doctor. Swelling on the plantar aspect of the foot was noticed, there was also pain at eversion of the foot and extension of the ankle. Plain X-ray showed no abnormalities. A MRI showed minimal bone bruise at the basis of M1 and a partial rupture of the peroneus longus tendon at its insertion. The patient was allowed to walk with partial weight bearing with a soft ankle brace. After 6 months she presented at our hospital because of persistent pain. There was still a painful insertion of the peroneus longus but active plantarflexion of M1 was possible. Plain X-rays were poorly contributive except for a discrete flattening of the longitunal arch. CT-scan showed a non displaced fracture at the M1-basis. A protocol with partial weight-bearing in a short-leg cast and partial weight-bearing orthosis each for 6 weeks was unsuccessfully attempted. Therefore, an excision of the non healed bone fragment at the basis of M1 and a first tarsometatarsal joint arthrodesis were performed. Postoperatively the patient wore a partial weight-bearing short leg cast for 6 weeks followed by a weight-bearing short leg cast for 6 weeks with favourable outcome. Discussion: Initial internal fixation has been reported to lead to good results [1, 2]. In our case the conservative treatment failed and leaded to non union. At that time we considered as too risky (overweight) to excise the fragment and reattach the peroneus longus tendon. Therefore, we excised the fragment and fused the first tarsometatarsal joint. This procedure allowed, at least partially, to compensate for the function of the peroneus longus tendon. 1 Murakami T, et al. Avulsion fracture of the peroneus longus at the first metatarsal insertion: a case report. Br J Sports Med. 2004. 2 Kwak HY, and Bae SW. Isolated avulsion fracture at the plantar lateral base of the first metatarsal: a case report. Foot Ankle Int 2000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly Labor Force Data report produced by the Iowa Workforce Development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Partitioning of proteins in cholesterol and sphingolipid enriched plasma membrane microdomains, called lipid rafts, is critical for many signal transduction and protein sorting events. Although raft partitioning of many signaling molecules remains to be determined, glycosylphosphatidyl-inositol (GPI)-anchored proteins possess high affinity for lipid rafts and are currently exploited as markers to investigate fundamental mechanisms in protein sorting and signal transduction events. In this study, we demonstrate that two recombinant GPI-anchored green fluorescent proteins (GFP-GPIs) that differ in their GPI signal sequence confer distinct localization in plasma membrane microdomains. GFP fused to the GPI signal of the decay accelerating factor GFP-GPI(DAF) partitioned exclusively in lipid rafts, whereas GFP fused to the GPI signal of TRAIL-R3, GFP-GPI(TRAIL-R3), associated only minimally with microdomains. In addition, we investigated the unique ability of purified GFP-GPIs to insert into membrane microdomains of primary lymphocytes. This cell surface painting allows rapid, stable, and functional association of the GPI-anchored proteins with the target cell plasma membrane. The distinct membrane localization of the two GFP-GPIs was observed irrespective of whether the GPI-anchored molecules were painted or transfected. Furthermore, we show that painted GFP-GPI(DAF) was totally dependent on the GPI anchor and that the membrane insertion was increased by the addition of raft-associated lipids such as cholesterol, sphingomyelin, and dipalmitoyl-phosphatidylethanolamine. Thus, this study provides evidence that different GPI signal sequences lead to distinct membrane microdomain localization and that painted GFP-GPI(DAF) serves as an excellent fluorescent marker for lipid rafts in live cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly Labor Force Data report produced by the Iowa Workforce Development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly Labor Force Data report produced by the Iowa Workforce Development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly Labor Force Data report produced by the Iowa Workforce Development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly Labor Force Data report produced by the Iowa Workforce Development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly Labor Force Data report produced by the Iowa Workforce Development.