911 resultados para Knee Extension
Resumo:
BACKGROUND: The ideal local anesthetic regime for femoral nerve block that balances analgesia with mobility after total knee arthroplasty (TKA) remains undefined. QUESTIONS/PURPOSES: We compared two volumes and concentrations of a fixed dose of ropivacaine for continuous femoral nerve block after TKA to a single injection femoral nerve block with ropivacaine to determine (1) time to discharge readiness; (2) early pain scores and analgesic consumption; and (3) functional outcomes, including range of motion and WOMAC scores at the time of recovery. METHODS: Ninety-nine patients were allocated to one of three continuous femoral nerve block groups for this randomized, placebo-controlled, double-blind trial: a high concentration group (ropivacaine 0.2% infusion), a low concentration group (ropivacaine 0.1% infusion), or a placebo infusion group (saline 0.9% infusion). Infusions were discontinued on postoperative Day (POD) 2. The primary outcome was time to discharge readiness. Secondary outcomes included opioid consumption, pain, and functional outcomes. Ninety-three patients completed the study protocol; the study was halted early because of unanticipated changes to pain protocols at the host institution, by which time only 61% of the required number of patients had been enrolled. RESULTS: With the numbers available, the mean time to discharge readiness was not different between groups (high concentration group, 62 hours [95% confidence interval [CI], 51-72 hours]; low concentration group, 73 hours [95% CI, 63-83 hours]; placebo infusion group 65 hours [95% CI, 56-75 hours]; p = 0.27). Patients in the low concentration group consumed significantly less morphine during the period of infusion (POD 1, high concentration group, 56 mg [95% CI, 42-70 mg]; low concentration group, 35 mg [95% CI, 27-43 mg]; placebo infusion group, 48 mg [95% CI, 38-59 mg], p = 0.02; POD 2, high concentration group, 50 mg [95% CI, 41-60 mg]; low concentration group, 33 mg [95% CI, 24-42 mg]; placebo infusion group, 39 mg [95% CI, 30-48 mg], p = 0.04); however, there were no important differences in pain scores or opioid-related side effects with the numbers available. Likewise, there were no important differences in functional outcomes between groups. CONCLUSIONS: Based on this study, which was terminated prematurely before the desired sample size could be achieved, we were unable to demonstrate that varying the concentration and volume of a fixed-dose ropivacaine infusion for continuous femoral nerve block influences time to discharge readiness when compared with a conventional single-injection femoral nerve block after TKA. A low concentration of ropivacaine infusion can reduce postoperative opioid consumption but without any important differences in pain scores, side effects, or functional outcomes. These pilot data may be used to inform the statistical power of future randomized trials. LEVEL OF EVIDENCE: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Resumo:
BACKGROUND: Extension of retinoblastoma cells into the posterior chamber is a criterion for group E according to the international classification of intraocular retinoblastoma. Currently, the anterior extension of retinoblastoma is based on the presence of tumour cells in the anterior chamber assessed by biomicroscopy. AIM: To determine the value of ultrasound biomicroscopy (UBM) in the assessment of posterior chamber involvement in advanced retinoblastoma. METHODS: Retrospective review of all retinoblastoma cases enucleated at the Jules Gonin Eye Hospital from January 1996 to December 2009 for which UBM (35 MHz) evaluation was available. The patients' records were reviewed for patient and tumour features and histopathological findings. UBM findings were compared with histopathological features. RESULTS: UBM documentation was available in 31 cases. Retinoblastoma was detected by UBM in the posterior chamber in 18 cases and was absent in 13 cases while histopathological analysis demonstrated its presence in the posterior chamber in 22 cases and its absence in 9 cases. Among the 18 UBM-positive cases, 7 had biomicroscopic detectable involvement of the anterior chamber. There was a significant correlation between echodensities consistent with retinoblastoma on UBM in the posterior chamber and histopathological tumorous involvement of the posterior chamber (p=0.0001). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity was 100%. CONCLUSION: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the precise evaluation of anterior extension of disease, with good sensitivity and specificity for the assessment of posterior chamber involvement. UBM may provide useful criteria governing the indication for enucleation.
Resumo:
Popliteal pseudoaneurysm is a rare but important complication of knee arthroplasties. To our knowledge, this complication has not been reported previously in the literature after unicompartmental knee arthroplasty. Apart from intraoperatively caused arterial injuries, obese patients and other previous cardiovascular diseases may be potential factors of risks for pseudoaneurysm in knee surgeries. As it is an uncommon complication and it has inconspicuous symptoms, both diagnosis and treatment can be delayed. This means that a high level of suspicion is necessary to prevent serious complications derived from pseudoaneurysms. LEVEL OF EVIDENCE Level IV.
Resumo:
BACKGROUND The purpose of the present study is to translate and validate the "Hip and Knee Outcomes Questionnaire", developed in English, into Spanish. The 'Hip and Knee Outcomes Questionnaire is a questionnaire planned to evaluate the impact in quality of life of any problem related to the human musculoskeletal system. 10 scientific associations developed it. METHODS The questionnaire underwent a validated translation/retro-translation process. Patients undergoing primary knee arthroplasty, before and six months postoperative, tested the final version in Spanish. Psychometric properties of feasibility, reliability, validity and sensitivity to change were assessed. Convergent validity with SF-36 and WOMAC questionnaires was evaluated. RESULTS 316 patients were included. Feasibility: a high number of missing items in questions 3, 4 and 5 were observed. The number of patients with a missing item was 171 (51.35%) in the preoperative visit and 139 (44.0%) at the postoperative. Internal validity: revision of coefficients in the item-rest correlation recommended removing question 6 during the preoperative visit (coefficient <0.20). Convergent validity: coefficients of correlation with WOMAC and SF-36 scales confirm the questionnaire's validity. Sensitivity to change: statistically significant differences were found between the mean scores of the first visit compared to the postoperative. CONCLUSION The proposed translation to Spanish of the 'Hip and Knee Questionnaire' is found to be reliable, valid and sensible to changes produced at the clinical practice of patients undergoing primary knee arthroplasty. However, some changes at the completion instructions are recommended. LEVEL OF EVIDENCE Level I. Prognostic study.
Resumo:
Aims: To investigate the long-term efficacy and safety of denosumab (DMAb) for the treatment of postmenopausal women with osteoporosis in an open-label extension to the 3-year FREEDOM study.1Methods: All women who completed the FREEDOM study were eligible to enter a long-term open-label extension (up to 10 years). After providing informed consent, participants received 6-monthly subcutaneous injections of DMAb (60 mg). Here we report data from the first year of followup. For women randomized to DMAb in the FREEDOM study ('long-term group'), this represents up to 48 months of DMAb exposure (eight 6-monthly injections). For those randomized to placebo ('de novo group') the data are from up to 12 months of exposure (two injections). All participants continued to take calcium (1 g) and vitamin D (≥400 IU) supplements daily. Changes in bone mineral density (BMD) and bone turnover markers (BTM) are reported for subjects enrolled in the extension. No formal statistical testing was planned for this interim report. P-values are descriptive.Results: Overall, 4,550 eligible women (70.2%) who completed the FREEDOM study entered the open-label extension study (long-term, n=2,343; de novo, n=2,207). During the first year of the extension, lumbar spine (LS) BMD in the long-term group further increased by 2.0% (12.1% increase vs. FREEDOM baseline at 48 months), and total hip (TH) BMD further increased by 0.8% (6.5% increase at 48 months) (p<0.0001 for both BMD gains during year 4; Fig. 1). During the first year of the extension, LS and TH BMD increased by 5.4% and 3.0%, respectively in the de novo group (both p<0.0001). After DMAb initiation, serum C-telopeptide (CTX) in the de novo group decreased rapidly and similarly to the long-term group (Fig. 2). Reductions in BTMs continue to attenuate at the end of the dosing interval as previously reported. Adverse event (AE) rates were similar (70.4% of women in the longterm group and 67.9% in the de novo group). Serious Aes were also similar (9.8% and 11.2% of women, respectively). During year 4, osteoporotic nonvertebral fractures were reported in 31 women in the long-term group and 51 in the denovo group.Fig. 1. Percentage change in BMD with denosumab for4 years (long-term) or 1 year (de novo)Fig. 2. Percentage change in sCTX over timeConclusions: These interim results suggest that continuation of DMAb treatment through 48 months is associated with further significant increases in spine and hip BMD with sustained reduction of bone turnover. The de-novo treatment group results confirm the first year active treatment findings previously reported1.Acknowledgements: Amgen Inc. sponsored this study. Figure ©2010, American Society for Bone and Mineral Research, used by permission, all rights reserved. Disclosure of Interest: H. Bone Grant/Research Support from: Amgen, Eli Lilly, Merck, Nordic Bioscience, Novartis, Takeda Pharmaceuticals, Consultant/Speaker's bureau/ Advisory activities with: Amgen, Merck, Takeda Pharmaceuticals, Zelos, S. Papapoulos Consultant/Speaker's bureau/ Advisory activities with: Amgen, Merck, Novartis, Lilly, Procter and Gamble, GSK, M.-L. Brandi Grant/Research Support from: MSD, GSK, Nycomed, NPS, Amgen, J. Brown Grant/Research Support from: Abbott, Amgen, Bristol Myers Squibb, Eli Lilly, Pfizer, Roche, Consultant/ Speaker's bureau/Advisory activities with: Abbott, Amgen, Eli Lilly, Novartis, Merck, Warner Chilcott,, R. Chapurlat Grant/Research Support from: Servier, Sanofi-Aventis, Warner-Chilcott, Novartis, Merck, Consultant/Speaker's bureau/Advisory activities with: Servier, Novartis, Amgen, E. Czerwinski: None Declared, N. Daizadeh Employee of: Amgen Inc., Stock ownership or royalties of: Amgen Inc., A. Grauer Employee of: Amgen Inc., Stock ownership or royalties of: Amgen Inc., C. Haller Employee of: Amgen Inc., Stock ownership or royalties of: Amgen Inc., M.-A. Krieg: None Declared, C. Libanati Employee of: Amgen Inc., Stock ownership or royalties of: Amgen Inc., Z. Man Grant/Research Support from: Amgen, D. Mellström: None Declared, S. Radominski Grant/Research Support from: Amgen, Pfizer, Roche, BMS, J.-Y. Reginster Grant/Research Support from: Bristol Myers Squibb, Merck Sharp & Dohme, Rottapharm, Teva, Lilly, Novartis, Roche, GlaxoSmithKline, Amgen, Servier, Consultant/Speaker's bureau/ Advisory activities with: Servier, Novartis, Negma, Lilly,Wyeth, Amgen, GlaxoSmithKline, Roche, Merckle, Nycomed, NPS, Theramex, UCB, Merck, Sharpe & Dohme, Rottapharm, IBSA, Genvrier, Teijin, Teva, Ebewee Pharma, Zodiac, Analis, Theramex, Novo-Nordisk, H. Resch: None Declared, J. A. Román Grant/Research Support from: Roche, Pharma, C. Roux Grant/Research Support from: Amgen, MSD, Novartis, Servier, Roche, Consultant/ Speaker's bureau/Advisory activities with: Amgen, MSD, Novartis, Servier, Roche, S. Cummings Grant/ Research Support from: Amgen, Lilly, Consultant/Speaker's bureau/Advisory activities with: Amgen, Lilly, Novartis, Merck
Resumo:
Introduction.- Knee injuries are frequent in a young and active population. Most of the patients resume their professional activity but few studies were interested in factors that predict a return to work. The aim of this study is to identify these predictors from a large panel of bio-psychosocial variables. We postulated that the return to work 3 months and 2 years after discharge is mostly predicted by psychosocial variables.Patients and methods.- Prospective study, patients hospitalized for a knee injury. Variables measured: the abbreviated injury score (AIS) for the gravity of the injuries, analog visual scale for the intensity of pain, INTERMED for the bio-psychosocial complexity, SF-36 for the quality of life, HADs for the anxiety/depression symptoms and IKDC score for the knee function. Univariate logistic regressions, adjusted for age and gender, were performed in order to predict return to work.Results.- One hundred and twenty-six patients hospitalized during 8 months after the accident were included into this prospective study. A total of 73 (58%) and 75 (59%) questionnaires were available after 3 months and 2 years, respectively. The SF-36 pain was the sole predictor of return to work at 3 months (odds Ratio 1.06 [1.02-1.10], P = 0.01; for a one point increase) and 2 years (odds Ratio 1.06 [1.02-1.10], P = 0.01). At three months, other factors are SF-36 (physic sub-scale), IKDC score, the presence of a work contract and the presence of litigation. The bio-psychosocial complexity, the presence of depressive symptoms predicts the return to work at two years.Discussion.- Our working hypothesis was partially confirmed: some psychosocial factors (i.e. depressive symptoms, work contract, litigation, INTERMED) predict the return to work but the physical health and the knee function, perceived by the patient, are also correlated. Pain is the sole factor isolated at both times (i.e. 3 months and 2 years) and, consequently, appears a key element in the prediction of the return to work. Some factors are accessible to the rehabilitation program but only if an interdisciplinary approach is performed.
Resumo:
Tectonic observations in the Tethyan Himalaya reveal an important extensional event that succeeds the emplacement of SW-verging nappes. A major thrust, called the Kum Tso Thrust, has been backfolded and reactivated by normal faulting associated with this event. Measurements of the Kubler index, coupled with characterization of clay-size paragenesis show the effect of normal faulting on the regional metamorphic zonation and indicate that important extension zones, like the Sarchu-Lachung La Normal Fault Zone (SLFZ), exist within the Tethyan Himalaya. Diagenetic limestones from within the SLFZ are characterized by the occurrence of mixed-layered clay phases, kaolinite and an illite with a 001 peak >0.4 Delta degrees2 theta. This zone is bordered by two anchizonal-to-epizonal zones, where illite peaks become narrower. Further to the NE the successive appearance of biotite, chloritoid, garnet and garnet-staurolite-kyanite assemblapes testifies to an increase in metamorphic grade. The cataclastic samples from the normal faults contain kaolinite, smectite and a `broad' illite, indicating that extension occurs under diagenetic conditions.
Resumo:
Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.
Resumo:
Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.