971 resultados para Immunologic Tests -- methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cyst-based ecotoxicological tests are simple and low-cost methods for assessing acute toxicity. Nevertheless, only a few comparative studies on their sensitivity are known. In the present study, the suitability of the use of two freshwater Anostracan species, Streptocephalus rubricaudatus and S. texanus, was assessed. The impact of 16 priority pollutants (4 heavy metals, 11 organic, and 1 organometallic compounds) on these two species, as well as on Artemia salina (Artoxkit M), Daphnia magna (International Organization for Standardization 6341), and S. proboscideus (Streptoxkit F) was assessed. For indicative comparison, bioassays using Brachionus calyciflorus (Rotoxkit F) and Photobacterium phosphoreum (Microtox) were also performed. For heavy metals (K2Cr2O7, Cd2+, Zn2+, Cu2+), the sensitivity of the two studied Streptocephalus species was slightly higher than that of D. magna. It was significantly more elevated than for the marine A. salina. For organic and organometallic micropollutants [phenol, 3,5-dichlorophenol, pentachlorophenol (PCP), hydroquinone, linear alkylbenzene sulfonate, sodium dodecyl sulfate, tributylphosphate, dimethylphthalate, atrazine, lindane, malathion, tributyltin chloride (TBT-Cl)], the sensitivity of the 4 anostracan species was of the same order of magnitude as that of D. magna. Artemia salina was slightly less sensitive to some organic compounds (PCP, hydroquinone, TBT-Cl). The sensitivity of S. rubricaudatus to organic solvents was low. On the other hand, this anostracan was quite sensitive to NaCl. Thus, its use is restricted to freshwater samples. The evaluation of global practicability of these two tests confirms that cyst-based freshwater anostracans may be used to perform low-cost tests at a sensitivity comparable to that of D. magna (24 h immobilization test).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to compare two different maximal incremental tests with different time durations [a maximal incremental ramp test with a short time duration (8-12 min) (STest) and a maximal incremental test with a longer time duration (20-25 min) (LTest)] to investigate whether an LTest accurately assesses aerobic fitness in class II and III obese men. Twenty obese men (BMI≥35 kg.m-2) without secondary pathologies (mean±SE; 36.7±1.9 yr; 41.8±0.7 kg*m-2) completed an STest (warm-up: 40 W; increment: 20 W*min-1) and an LTest [warm-up: 20% of the peak power output (PPO) reached during the STest; increment: 10% PPO every 5 min until 70% PPO was reached or until the respiratory exchange ratio reached 1.0, followed by 15 W.min-1 until exhaustion] on a cycle-ergometer to assess the peak oxygen uptake [Formula: see text] and peak heart rate (HRpeak) of each test. There were no significant differences in [Formula: see text] (STest: 3.1±0.1 L*min-1; LTest: 3.0±0.1 L*min-1) and HRpeak (STest: 174±4 bpm; LTest: 173±4 bpm) between the two tests. Bland-Altman plot analyses showed good agreement and Pearson product-moment and intra-class correlation coefficients showed a strong correlation between [Formula: see text] (r=0.81 for both; p≤0.001) and HRpeak (r=0.95 for both; p≤0.001) during both tests. [Formula: see text] and HRpeak assessments were not compromised by test duration in class II and III obese men. Therefore, we suggest that the LTest is a feasible test that accurately assesses aerobic fitness and may allow for the exercise intensity prescription and individualization that will lead to improved therapeutic approaches in treating obesity and severe obesity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plutonium and Sr-90 are considered to be among the most radiotoxic nuclides produced by the nuclear fission process. In spite of numerous studies on mammals and humans there is still no general agreement on the retention half time of both radionuclides in the skeleton in the general population. Here we determined plutonium and Sr-90 in human vertebrae in individuals deceased between 1960 and 2004 in Switzerland. Plutonium was measured by sensitive SF-ICP-MS techniques and Sr-90 by radiometric methods. We compared our results to the ones obtained for other environmental compartments to reveal the retention half time of NBT fallout Pu-239 and Sr-90 in trabecular bones of the Swiss population. Results show that plutonium has a retention half time of 40 +/- 14 years. In contrast Sr-90 has a shorter retention half time of 13.5 +/- 1.0 years. Moreover Sr-90 retention half time in vertebrae is shown to be linked to the retention half time in food and other environmental compartments. These findings demonstrate that the renewal of the vertebrae through calcium homeostatic control is faster for Sr-90 excretion than for plutonium excretion. The precise determination of the retention half time of plutonium in the skeleton will improve the biokinetic model of plutonium metabolism in humans. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

DnaSP is a software package for the analysis of DNA polymorphism data. Present version introduces several new modules and features which, among other options allow: (1) handling big data sets (~5 Mb per sequence); (2) conducting a large number of coalescent-based tests by Monte Carlo computer simulations; (3) extensive analyses of the genetic differentiation and gene flow among populations; (4) analysing the evolutionary pattern of preferred and unpreferred codons; (5) generating graphical outputs for an easy visualization of results. Availability: The software package, including complete documentation and examples, is freely available to academic users from: http://www.ub.es/dnasp

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The identification of CTL-defined tumor-associated Ags has allowed the development of new strategies for cancer immunotherapy. To potentiate the CTL responses, peptide-based vaccines require the coadministration of adjuvants. Because oligodeoxynucleotides (ODN) containing CpG motifs are strong immunostimulators, we analyzed the ability of CpG ODN to act as adjuvant of the CTL response against tumor-derived synthetic peptide in the absence or presence of IFA. Mice transgenic for a chimeric MHC class I molecule were immunized with a peptide analog of MART-1/Melan-A(26-35) in the presence of CpG ODN alone or CpG ODN emulsified in IFA. The CTL response was monitored ex vivo by tetramer staining of lymphocytes. In blood, spleen, and lymph nodes, peptide mixed with CpG ODN alone was able to elicit a stronger systemic CTL response as compared with peptide emulsified in IFA. Moreover, CpG ODN in combination with IFA further enhanced the CTL response in terms of the frequency of tetramer+CD8+ T cells ex vivo. The CTL induced in vivo against peptide analog in the presence of CpG ODN are functional, as they were able to recognize and kill melanoma cells in vitro. Overall, these results indicate that CpG ODN by itself is a good candidate adjuvant of CTL response and can also enhance the effect of classical adjuvant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the use of supplementary cementing materials (SCMs) in concrete mixtures, salt scaling tests such as ASTM C672 have been found to be overly aggressive and do correlate well with field scaling performance. The reasons for this are thought to be because at high replacement levels, SCM mixtures can take longer to set and to develop their properties: neither of these factors is taken into account in the standard laboratory finishing and curing procedures. As a result, these variables were studied as well as a modified scaling test, based on the Quebec BNQ scaling test that had shown promise in other research. The experimental research focused on the evaluation of three scaling resistance tests, including the ASTM C672 test with normal curing as well as an accelerated curing regime used by VDOT for ASTM C1202 rapid chloride permeability tests and now included as an option in ASTM C1202. As well, several variations on the proposed draft ASTM WK9367 deicer scaling resistance test, based on the Quebec Ministry of Transportation BNQ test method, were evaluated for concretes containing varying amounts of slag cement. A total of 16 concrete mixtures were studied using both high alkali cement and low alkali cement, Grade 100 slag and Grade 120 slag with 0, 20, 35 and 50 percent slag replacement by mass of total cementing materials. Vinsol resin was used as the primary air entrainer and Micro Air® was used in two replicate mixes for comparison. Based on the results of this study, a draft alternative test method to ASTM C762 is proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Long-term treatment of primary HIV-1 infection (PHI) may allow the immune reconstitution of responses lost during the acute viremic phase and decrease of peripheral reservoirs. This in turn may represent the best setting for the use of therapeutic vaccines in order to lower the viral set-point or control of viral rebound upon ART discontinuation. Methods We investigated a cohort of 16 patients who started ART at PHI, with treatment duration of ≥4 years and persistent aviremia (<50 HIV-1 copies/ml). The cohort was characterized in terms of viral subtype, cell-associated RNA, proviral DNA and HLA genotype. Secretion of IFN-γ, IL-2 and TNF-α by CD8 T-cells was analysed by polychromatic flowcytometry using a panel of 192 HIV-1-derived epitopes. Results This cohort is highly homogenous in terms of viral subtype: 81% clade B. We identified 44 epitope-specific responses: all patients had detectable responses to >1 epitope and the mean number of responding epitopes per patient was 3. The mean frequency of cytokines-secreting CD8 T-cells was 0.32%. CD8 T-cells secreting simultaneously IFN-γ, IL-2 and TNF-α made up for about 40% of the response and cells secreting at least 2 cytokines for about 80%, consistent with a highly polyfunctional CD8 T-cell profile. There was no difference in term of polyfunctionality when HLA restriction, or recognized viral regions and epitopes were considered. Proviral DNA was detectable in all patients but at low levels (mean = 108 copies/1 million PBMCs) while cell-associated mRNA was not detectable in 19% of patients (mean = 11 copies/1 million PBMCs when detectable). Conclusion Patients with sustained virological suppression after initiation of ART at PHI show polyfunctional CD8 T-cell and low levels of proviral DNA with an absence of residual replication in a substantial percentage of patients. The use of therapeutic vaccines in this population may promote low level of rebound viremia or control of viral replication upon ART cessation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Expansion joints increase both the initial cost and the maintenance cost of bridges. Integral abutment bridges provide an attractive design alternative because expansion joints are eliminated from the bridge itself. However, the piles in these bridges are subjected to horizontal movement as the bridge expands and contracts during temperature changes. The objective of this research was to develop a method of designing piles for these conditions. Separate field tests simulating a pile and a bridge girder were conducted for three loading cases: (1) vertical load only, (2) horizontal displacement of pile head only, and (3) combined horizontal displacement of pile head with subsequent vertical load. Both tests (1) and (3) reached the same ultimate vertical load, that is, the horizontal displacement had no effect on the vertical load capacity. Several model tests were conducted in sand with a scale factor of about 1:10. Experimental results from both the field and model tests were used to develop the vertical and horizontal load-displacement properties of the soil. These properties were input into the finite element computer program Integral Abutment Bridge Two-Dimensional (IAB2D), which was developed under a previous research contract. Experimental and analytical results compared well for the test cases. Two alternative design methods, both based upon the American Association of State Highway and Transportation Officials (AASHTO) Specification, were developed. Alternative One is quite conservative relative to IAB2D results and does not permit plastic redistribution of forces. Alternative Two is also conservative when compared to IAB2D, but plastic redistribution is permitted. To use Alternative Two, the pile cross section must have sufficient inelastic rotation capacity before local buckling occurs. A design example for a friction pile and an end-bearing pile illustrates both alternatives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report is formatted to independently present four individual investigations related to similar web gap fatigue problems. Multiple steel girder bridges commonly exhibit fatigue cracking due to out-of-plane displacement of the web near the diaphragm connections. This fatigue-prone web gap area is typically located in negative moment regions of the girders where the diaphragm stiffener is not attached to the top flange. In the past, the Iowa Department of Transportation has attempted to stop fatigue crack propagation in these steel girder bridges by drilling holes at the crack tips. Other nondestructive retrofits have been tried; in a particular case on a two-girder bridge with floor beams, angles were bolted between the stiffener and top flange. The bolted angle retrofit has failed in the past and may not be a viable solution for diaphragm bridges. The drilled hole retrofit is often only a temporary solution, so a more permanent and effective retrofit is required. A new field retrofit has been developed that involves loosening the bolts in the connection between the diaphragm and the girders. Research on the retrofit has been initiated; however, no long-term studies of the effects of bolt loosening have been performed. The intent of this research is to study the short-term effects of the bolt loosening retrofit on I-beam and channel diaphragm bridges. The research also addressed the development of a continuous remote monitoring system to investigate the bolt loosening retrofit on an X-type diaphragm bridge over a number of months, ensuring that the measured strain and displacement reductions are not affected by time and continuous traffic loading on the bridge. The testing for the first three investigations is based on instrumentation of web gaps in a negative moment region on Iowa Department of Transportation bridges with I-beam, channel, and X-type diaphragms. One bridge of each type was instrumented with strain gages and deflection transducers. Field tests, using loaded trucks of known weight and configuration, were conducted on the bridges with the bolts in the tight condition and after implementing the bolt loosening retrofit to measure the effects of loosening the diaphragm bolts. Long-term data were also collected on the X-diaphragm bridge by a data acquisition system that collected the data continuously under ambient truck loading. The collected data were retrievable by an off-site modem connection to the remote data acquisition system. The data collection features and ruggedness of this system for remote bridge monitoring make it viable as a pilot system for future monitoring projects in Iowa. Results indicate that loosening the diaphragm bolts reduces strain and out-of-plane displacement in the web gap, and that the reduction is not affected over time by traffic or environmental loading on the bridge. Reducing the strain in the web gap allows the bridge to support more cycles of loading before experiencing fatigue, thus increase the service life of the bridge. Two-girder floor beam bridges may also exhibit fatigue cracking in girder webs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tumour immunologists strive to develop efficient tumour vaccination and adoptive transfer therapies that enlarge the pool of tumour-specific and -reactive effector T-cells in vivo. To assess the efficiency of the various strategies, ex vivo assays are needed for the longitudinal monitoring of the patient's specific immune responses providing both quantitative and qualitative data. In particular, since tumour cell cytolysis is the end goal of tumour immunotherapy, routine immune monitoring protocols need to include a read-out for the cytolytic efficiency of Ag-specific cells. We propose to combine current immune monitoring techniques in a highly sensitive and reproducible multi-parametric flow cytometry based cytotoxicity assay that has been optimised to require low numbers of Ag-specific T-cells. The possibility of re-analysing those T-cells that have undergone lytic activity is illustrated by the concomitant detection of CD107a upregulation on the surface of degranulated T-cells. To date, the LiveCount Assay provides the only possibility of assessing the ex vivo cytolytic activity of low-frequency Ag-specific cytotoxic T-lymphocytes from patient material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With ever tightening budgets and limitations of demolition equipment, states are looking for cost-effective, reliable, and sustainable methods for removing concrete decks from bridges. The goal of this research was to explore such methods. The research team conducted qualitative studies through a literature review, interviews, surveys, and workshops and performed small-scale trials and push-out tests (shear strength evaluations). Interviews with bridge owners and contractors indicated that concrete deck replacement was more economical than replacing an entire superstructure under the assumption that the salvaged superstructure has adequate remaining service life and capacity. Surveys and workshops provided insight into advantages and disadvantages of deck removal methods, information that was used to guide testing. Small-scale trials explored three promising deck removal methods: hydrodemolition, chemical splitting, and peeling

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes new methodologies for evaluating out-of-sample forecastingperformance that are robust to the choice of the estimation window size. The methodologies involve evaluating the predictive ability of forecasting models over a wide rangeof window sizes. We show that the tests proposed in the literature may lack the powerto detect predictive ability and might be subject to data snooping across differentwindow sizes if used repeatedly. An empirical application shows the usefulness of themethodologies for evaluating exchange rate models' forecasting ability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diagnosis in allergology is facing novel challenges because of the availability not only of purified or recombinant allergens, but also of multitests such as allergen micro-arrays. These new diagnostic opportunities contribute to a better understanding of crossreactivities between respiratory and food allergens. In comparison to current diagnosis based on whole allergen extracts, this novel generation of specific IgE tests is expected to provide better information on the risk of reaction to allergens as well as on its severity. However these new technologies are expensive, and will have to be carefully analyzed in terms of medical usefulness and public health costs.