975 resultados para Imaging diagnostic agents


Relevância:

30.00% 30.00%

Publicador:

Resumo:

MRI has evolved into an important diagnostic technique in medical imaging. However, reliability of the derived diagnosis can be degraded by artifacts, which challenge both radiologists and automatic computer-aided diagnosis. This work proposes a fully-automatic method for measuring image quality of three-dimensional (3D) structural MRI. Quality measures are derived by analyzing the air background of magnitude images and are capable of detecting image degradation from several sources, including bulk motion, residual magnetization from incomplete spoiling, blurring, and ghosting. The method has been validated on 749 3D T(1)-weighted 1.5T and 3T head scans acquired at 36 Alzheimer's Disease Neuroimaging Initiative (ADNI) study sites operating with various software and hardware combinations. Results are compared against qualitative grades assigned by the ADNI quality control center (taken as the reference standard). The derived quality indices are independent of the MRI system used and agree with the reference standard quality ratings with high sensitivity and specificity (>85%). The proposed procedures for quality assessment could be of great value for both research and routine clinical imaging. It could greatly improve workflow through its ability to rule out the need for a repeat scan while the patient is still in the magnet bore.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Stem cell labeling with iron oxide (ferumoxide) particles allows labeled cells to be detected by magnetic resonance imaging (MRI) and is commonly used to track stem cell engraftment. However, the validity of MRI for distinguishing surviving ferumoxide-labeled cells from other sources of MRI signal, for example, macrophages containing ferumoxides released from nonsurviving cells, has not been thoroughly investigated. We sought to determine the relationship between the persistence of iron-dependent MRI signals and cell survival 3 weeks after injection of syngeneic or xenogeneic ferumoxides-labeled stem cells (cardiac-derived stem cells) in rats. METHODS AND RESULTS: We studied nonimmunoprivileged human and rat cardiac-derived stem cells and human mesenchymal stem cells doubly labeled with ferumoxides and beta-galactosidase and injected intramyocardially into immunocompetent Wistar-Kyoto rats. Animals were imaged at 2 days and 3 weeks after stem cell injection in a clinical 3-T MRI scanner. At 2 days, injection sites of xenogeneic and syngeneic cells (cardiac-derived stem cells and mesenchymal stem cells) were identified by MRI as large intramyocardial signal voids that persisted at 3 weeks (50% to 90% of initial signal). Histology (at 3 weeks) revealed the presence of iron-containing macrophages at the injection site, identified by CD68 staining, but very few or no beta-galactosidase-positive stem cells in the animals transplanted with syngeneic or xenogeneic cells, respectively. CONCLUSIONS: The persistence of significant iron-dependent MRI signal derived from ferumoxide-containing macrophages despite few or no viable stem cells 3 weeks after transplantation indicates that MRI of ferumoxide-labeled cells does not reliably report long-term stem cell engraftment in the heart.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Advisa MRI system is designed to safely undergo magnetic resonance imaging (MRI). Its influence on image quality is not well known. OBJECTIVE: To evaluate cardiac magnetic resonance (CMR) image quality and to characterize myocardial contraction patterns by using the Advisa MRI system. METHODS: In this international trial with 35 participating centers, an Advisa MRI system was implanted in 263 patients. Of those, 177 were randomized to the MRI group and 150 underwent MRI scans at the 9-12-week visit. Left ventricular (LV) and right ventricular (RV) cine long-axis steady-state free precession MR images were graded for quality. Signal loss along the implantable pulse generator and leads was measured. The tagging CMR data quality was assessed as the percentage of trackable tagging points on complementary spatial modulation of magnetization acquisitions (n=16) and segmental circumferential fiber shortening was quantified. RESULTS: Of all cine long-axis steady-state free precession acquisitions, 95% of LV and 98% of RV acquisitions were of diagnostic quality, with 84% and 93%, respectively, being of good or excellent quality. Tagging points were trackable from systole into early diastole (360-648 ms after the R-wave) in all segments. During RV pacing, tagging demonstrated a dyssynchronous contraction pattern, which was not observed in nonpaced (n = 4) and right atrial-paced (n = 8) patients. CONCLUSIONS: In the Advisa MRI study, high-quality CMR images for the assessment of cardiac anatomy and function were obtained in most patients with an implantable pacing system. In addition, this study demonstrated the feasibility of acquiring tagging data to study the LV function during pacing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite a low positive predictive value, diagnostic tests such as complete blood count (CBC) and C-reactive protein (CRP) are commonly used to evaluate whether infants with risk factors for early-onset neonatal sepsis (EOS) should be treated with antibiotics. We investigated the impact of implementing a protocol aiming at reducing the number of diagnostic tests in infants with risk factors for EOS in order to compare the diagnostic performance of repeated clinical examination with CBC and CRP measurement. The primary outcome was the time between birth and the first dose of antibiotics in infants treated for suspected EOS. Among the 11,503 infants born at ≥35 weeks during the study period, 222 were treated with antibiotics for suspected EOS. The proportion of infants receiving antibiotics for suspected EOS was 2.1% and 1.7% before and after the change of protocol (p = 0.09). Reduction of diagnostic tests was associated with earlier antibiotic treatment in infants treated for suspected EOS (hazard ratio 1.58; 95% confidence interval [CI] 1.20-2.07; p <0.001), and in infants with neonatal infection (hazard ratio 2.20; 95% CI 1.19-4.06; p = 0.01). There was no difference in the duration of hospital stay nor in the proportion of infants requiring respiratory or cardiovascular support before and after the change of protocol. Reduction of diagnostic tests such as CBC and CRP does not delay initiation of antibiotic treatment in infants with suspected EOS. The importance of clinical examination in infants with risk factors for EOS should be emphasised.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intracellular bacteria are common causes of community-acquired pneumonia that grow poorly or not at all on standard culture media and do not respond to beta-lactam antibiotic therapy. Apart from well-established agents of pneumonia such as Legionella pneumophila, Mycoplasma pneumoniae, Chlamydia pneumoniae, Chlamydia psittaci and Coxiella burnetii, some new emerging pathogens have recently been recognized, mainly Parachlamydia acanthamoebae and Simkania negevensis, two Chlamydia-related bacteria. Most of them are causes of benign and self-limited infections. However, they may cause severe pneumonia in some cases (i.e., Legionnaires' disease) and they may cause outbreaks representing a public health problem deserving prompt recognition and appropriate therapy. Although extrapulmonary manifestations are often present, no clinical features allow them to be distinguished from classical bacterial agents of pneumonia such as Streptococcus pneumoniae. Thus, specific molecular diagnostic tools are very helpful for early recognition of the offending bacteria, whereas serology often only allows retrospective or late diagnosis. Macrolides remain the best empirical treatment of intracellular respiratory pathogens, although some observational studies suggest that quinolones may be superior for the treatment of legionellosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Charcot neuropathic osteoarthropathy (CNO) is a destructive process affecting the bone and joint structure of diabetic patients and resulting from peripheral neuropathy. It is a limb threatening condition resulting in dramatic deformities associated with severe morbi-mortality. The diagnosis is mostly made by the observation of inflammatory signs and higlight the importance of prompt foot evaluation. Imaging studies may help confirm the diagnosis and the severity of the condition but lack of specificity. The goal of the treatment is to maintain or achieve structural stability of the foot and ankle to prevent further deformity and plantar dislocation. The scientific evidences aren't strong enough to recommend bisphosphonates or acute surgical treatment. Surgery is unanimusly recommended to prevent secondary ulceration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Noninvasive imaging of atherosclerosis is being increasingly used in clinical practice, with some experts recommending to screen all healthy adults for atherosclerosis and some jurisdictions mandating insurance coverage for atherosclerosis screening. Data on the impact of such screening have not been systematically synthesized. OBJECTIVES: We aimed to assess whether atherosclerosis screening improves cardiovascular risk factors (CVRF) and clinical outcomes. DESIGN: This study is a systematic review. DATA SOURCES: We searched MEDLINE and the Cochrane Clinical Trial Register without language restrictions. STUDY ELIGIBILITY CRITERIA: We included studies examining the impact of atherosclerosis screening with noninvasive imaging (e.g., carotid ultrasound, coronary calcification) on CVRF, cardiovascular events, or mortality in adults without cardiovascular disease. RESULTS: We identified four randomized controlled trials (RCT, n=709) and eight non-randomized studies comparing participants with evidence of atherosclerosis on screening to those without (n=2,994). In RCTs, atherosclerosis screening did not improve CVRF, but smoking cessation rates increased (18% vs. 6%, p=0.03) in one RCT. Non-randomized studies found improvements in several intermediate outcomes, such as increased motivation to change lifestyle and increased perception of cardiovascular risk. However, such data were conflicting and limited by the lack of a randomized control group. No studies examined the impact of screening on cardiovascular events or mortality. Heterogeneity in screening methods and studied outcomes did not permit pooling of results. CONCLUSION: Available evidence about atherosclerosis screening is limited, with mixed results on CVRF control, increased smoking cessation in one RCT, and no data on cardiovascular events. Such screening should be validated by large clinical trials before widespread use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For the past decade, PET and PET/CT have been widely studied for myocardial perfusion imaging. Several studies demonstrated the incremental value of PET for the diagnostic and prognostic assessment of patients with coronary artery disease. Moreover, PET allows for non-invasively quantifying myocardial blood flow and myocardial flow reserve, that both are recognized as surrogate marker of cardiac event free survival. By enabling the exploration of epicardial disease and the microvasculature, PET constitutes a unique tool to study pathophysiogical mechanisms leading to atherosclerosis genesis. The recent emergence of high-tech hybrid machines may even provide further incremental information about coronary function and morphology. By taking the best of each modality, a better assessment of patients with coronary artery disease is expected. (C) 2011 Elsevier Masson SAS. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical Impedance Tomography (EIT) is an imaging method which enables a volume conductivity map of a subject to be produced from multiple impedance measurements. It has the potential to become a portable non-invasive imaging technique of particular use in imaging brain function. Accurate numerical forward models may be used to improve image reconstruction but, until now, have employed an assumption of isotropic tissue conductivity. This may be expected to introduce inaccuracy, as body tissues, especially those such as white matter and the skull in head imaging, are highly anisotropic. The purpose of this study was, for the first time, to develop a method for incorporating anisotropy in a forward numerical model for EIT of the head and assess the resulting improvement in image quality in the case of linear reconstruction of one example of the human head. A realistic Finite Element Model (FEM) of an adult human head with segments for the scalp, skull, CSF, and brain was produced from a structural MRI. Anisotropy of the brain was estimated from a diffusion tensor-MRI of the same subject and anisotropy of the skull was approximated from the structural information. A method for incorporation of anisotropy in the forward model and its use in image reconstruction was produced. The improvement in reconstructed image quality was assessed in computer simulation by producing forward data, and then linear reconstruction using a sensitivity matrix approach. The mean boundary data difference between anisotropic and isotropic forward models for a reference conductivity was 50%. Use of the correct anisotropic FEM in image reconstruction, as opposed to an isotropic one, corrected an error of 24 mm in imaging a 10% conductivity decrease located in the hippocampus, improved localisation for conductivity changes deep in the brain and due to epilepsy by 4-17 mm, and, overall, led to a substantial improvement on image quality. This suggests that incorporation of anisotropy in numerical models used for image reconstruction is likely to improve EIT image quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Patients with magnetic resonance (MR)-negative focal epilepsy (MRN-E) have less favorable surgical outcomes (between 40% and 70%) compared to those in whom an MRI lesion guides the site of surgical intervention (60-90%). Patients with extratemporal MRN-E have the worst outcome (around 50% chance of seizure freedom). We studied whether electroencephalography (EEG) source imaging (ESI) of interictal epileptic activity can contribute to the identification of the epileptic focus in patients with normal MRI. METHODS: We carried out ESI in 10 operated patients with nonlesional MRI and a postsurgical follow-up of at least 1 year. Five of the 10 patients had extratemporal lobe epilepsy. Evaluation comprised surface and intracranial EEG monitoring of ictal and interictal events, structural MRI, [(18)F]fluorodeoxyglucose positron emission tomography (FDG-PET), ictal and interictal perfusion single photon emission computed tomography (SPECT) scans. Eight of the 10 patients also underwent intracranial monitoring. RESULTS: ESI correctly localized the epileptic focus within the resection margins in 8 of 10 patients, 9 of whom experienced favorable postsurgical outcomes. DISCUSSION: The results highlight the diagnostic value of ESI and encourage broadening its application to patients with MRN-E. If the surface EEG contains fairly localized spikes, ESI contributes to the presurgical decision process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite using modern microbiological diagnostic approaches, the aetiological agents of pneumonia remain unidentified in about 50% of cases. Some bacteria that grow poorly or not at all in axenic media used in routine clinical bacteriology laboratory but which can develop inside amoebae may be the agents of these lower respiratory tract infections (RTIs) of unexplained aetiology. Such amoebae-resisting bacteria, which coevolved with amoebae to resist their microbicidal machinery, may have developed virulence traits that help them survive within human macrophages, i.e. the first line of innate immune defence in the lung. We review here the current evidence for the emerging pathogenic role of various amoebae-resisting microorganisms as agents of RTIs in humans. Specifically, we discuss the emerging pathogenic roles of Legionella-like amoebal pathogens, novel Chlamydiae (Parachlamydia acanthamoebae, Simkania negevensis), waterborne mycobacteria and Bradyrhizobiaceae (Bosea and Afipia spp.).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Personal results are presented to illustrate the development of immunoscintigraphy for the detection of cancer over the last 12 years, from the early experimental results in nude mice grafted with human colon carcinoma to the most modern form of immunoscintigraphy applied to patients, using I123 labeled Fab fragments from monoclonal anti-CEA antibodies detected by single photon emission computerized tomography (SPECT). The first generation of immunoscintigraphy used I131 labeled, immunoadsorbent purified, polyclonal anti-CEA antibodies and planar scintigraphy, as the detection system. The second generation used I131 labeled monoclonal anti-CEA antibodies and SPECT, while the third generation employed I123 labeled fragments of monoclonal antibodies and SPECT. The improvement in the precision of tumor images with the most recent forms of immunoscintigraphy is obvious. However, we think the usefulness of immunoscintigraphy for routine cancer management has not yet been entirely demonstrated. Further prospective trials are still necessary to determine the precise clinical role of immunoscintigraphy. A case report is presented on a patient with two liver metastases from a sigmoid carcinoma, who received through the hepatic artery a therapeutic dose (100 mCi) of I131 coupled to 40 mg of a mixture of two high affinity anti-CEA monoclonal antibodies. Excellent localisation in the metastases of the I131 labeled antibodies was demonstrated by SPECT and the treatment was well tolerated. The irradiation dose to the tumor, however, was too low at 4300 rads (with 1075 rads to the normal liver and 88 rads to the bone marrow), and no evidence of tumor regression was obtained. Different approaches for increasing the irradiation dose delivered to the tumor by the antibodies are considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To describe a large family with autosomal dominant parkinsonism. BACKGROUND: Seven genes are directly implicated in autosomally inherited parkinsonism. However, there are several multigenerational large families known with no identifiable mutation. MATERIAL AND METHODS: Family members were evaluated clinically, by history and chart review. Genetic investigation included SCA2, SCA3, UCHL1, SNCA, LRRK2, PINK1, PRKN, PGRN, FMR1 premutation, and MAPT. The proband underwent brain fluorodopa PET (FD-PET) scan, and one autopsy was available. RESULTS: Eleven patients had a diagnosis of Parkinson's disease (PD), nine women. Mean age of onset was 52 with tremor-predominant dopa-responsive parkinsonism. Disease progression was slow but severe motor fluctuations occurred. One patient required subthalamic nucleus deep-brain stimulation with a good motor outcome. One patient had mental retardation, schizophrenia and became demented, and another patient was demented. Three patients and also two unaffected subjects had mild learning difficulties. All genetic tests yielded negative results. FD-PET showed marked asymmetric striatal tracer uptake deficiency, consistent with PD. Pathological examination demonstrated no Lewy bodies and immunostaining was negative for alpha-synuclein. CONCLUSION: Apart from a younger age of onset and a female predominance, the phenotype was indistinguishable from sporadic tremor-predominant PD, including FD-PET scan results. As known genetic causes of autosomal dominant PD were excluded, this family harbors a novel genetic defect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since January 2008-de facto 2012-medical physics experts (MPEs) are, by law, to be involved in the optimisation process of radiological diagnostic procedures in Switzerland. Computed tomography, fluoroscopy and nuclear medicine imaging units have been assessed for patient exposure and image quality. Large spreads in clinical practice have been observed. For example, the number of scans per abdominal CT examination went from 1 to 9. Fluoroscopy units showed, for the same device settings, dose rate variations up to a factor of 3 to 7. Quantitative image quality for positron emission tomography (PET)/CT examinations varied significantly depending on the local image reconstruction algorithms. Future work will be focused on promoting team cooperation between MPEs, radiologists and radiographers and on implementing task-oriented objective image quality indicators.