946 resultados para High-frequency induction
Resumo:
A 30-basepair (bp) deletion in the Epstein-Barr virus (EBV) latent membrane protein 1 (LMP1) gene has been reported in nasopharyngeal carcinoma and EBV-associated malignant lymphomas. Prior studies have found the deletion in about 10% to 28% of cases of Hodgkin's disease (HD), particularly in cases with aggressive histology. We studied the prevalence of 30-bp LMP1 gene deletion in EBV-positive HD in the United States (US) (12 cases) and Brazil (26 cases) with comparison to reactive lymphoid tissues (21 cases) and HD without EBV-positive Reed-Sternberg cells (15 cases). We studied the status of the LMP1 gene by Southern blot hybridization of polymerase chain reaction (PCR) products obtained after amplification with primers spanning the site of the deletion. We also performed EBV typing, EBER1 in situ hybridization, and LMP1 protein immunohistochemistry. EBV was detected in 12/26 (46%) cases of HD from the US and 26/27 (96%) cases of Brazilian HD. The 30-bp LMP1 gene deletion was observed in 4/12 (33%) cases of EBV-positive HD from US, and 12/26 (46%) cases of Brazilian EBV-positive HD, including 3 cases of type B EBV, as compared with 12/21 (57%) reactive lymphoid tissues and 9/15 (60%) cases of EBV-negative HD. US and Brazilian HD showed a higher prevalence of the 30-bp LMP1 gene deletion, compared with studies of others. The unexpected finding of high incidence of 30-bp deletion in LMP1 gene in reactive lymphoid tissue and HD without EBV-positive Reed-Sternberg cells suggests that this deletion may not be relevant to HD pathogenesis in most cases. Copyright (C) 1997 by W.B. Saunders Company.
Resumo:
Polycrystalline or single-crystal ferroelectric materials present dielectric dispersion in the frequency range 100 MHz-1 GHz that has been attributed to a dispersive ( relaxation-like) mechanism as well as a resonant mechanism. Particularly in 'normal' ferroelectric materials, a dielectric response that is indistinguishable from dispersion or a resonance has been reported. Nevertheless, the reported results are not conclusive enough to distinguish each mechanism clearly. A detailed study of the dielectric dispersion phenomenon has been carried out in PbTiO3-based ferroelectric ceramics, with the composition Pb1-xLaxTiO3 (x = 0.15), over a wide range of temperatures and frequencies, including microwave frequencies. The dielectric response of La-modified lead titanate ferroelectric ceramics, in 'virgin' and poled states, has been investigated in the temperature and frequency ranges 300-450 K and 1 kHz-2 GHz, respectively. The results revealed that the frequency dependence of the dielectric anomalies, depending on the measuring direction with respect to the orientation of the macroscopic polarization, may be described as a general mechanism related to an 'over-damped' resonant process. Applying either a uniaxial stress along the measurement field direction or a poling electric field parallel and/or perpendicular to the measuring direction, a resonant response of the real and imaginary components of the dielectric constant is observed, in contrast to the dispersion behavior obtained in the absence of the stress, for the 'virgin' samples. Both results, resonance and/or dispersion, can be explained by considering a common mechanism involving a resonant response (damped and/or over-damped) which is strongly affected by a ferroelastic-ferroelectric coupling, contributing to the low-field dielectric constant.
Resumo:
A robust 12 kW rectifier with low THD in the line currents, based on an 18-pulse transformer arrangement with reduced kVA capacities followed by a high-frequency isolation stage is presented in this work. Three full-bridge (buck-based) converters are used to allow galvanic isolation and to balance the dc-link currents, without current sensing or current controller. The topology provides a regulated dc output with a very simple and well-known control strategy and natural three-phase power factor correction. The phase-shift PWM technique, with zero-voltage switching is used for the high-frequency dc-dc stage. Analytical results from Fourier analysis of winding currents and the vector diagram of winding voltages are presented. Experimental results from a 12 kW prototype are shown in the paper to verify the efficiency, robustness and simplicity of the command circuitry to the proposed concept.
Resumo:
The research evaluated the efficacy of high frequency waves in the treatment of onychomycosis in three patients during twelve months through the clinical examination of nails and also through mycological examination. The causative agent of the mycosis, in the three patients, was the dermatophyte Trichophyton rubrum and after application of high frequency, it was possible to notice a great improvement in the appearance of nails and also growth inhibition in culture despite the fact that the mycological examination remained positive. The preliminary study of the three cases demonstrated that the fungistatic activity of high frequency waves is a promising method to be used in combination with conventional drugs.
Resumo:
We have studied the effects of niobium beam filtration on absorbed doses, on image density and contrast, and on photon spectra with conventional and high-frequency dental x-ray generators. Added niobium reduced entry and superficial absorbed doses in periapical radiography by 9% to 40% with film and digital image receptors, decreased the radiation necessary to produce a given image density on E-speed film and reduced image contrast on D- and E-speed films. As shown by increased half-value layers for aluminum, titanium, and copper and by pulse-height analyses of beam spectra, niobium increased average beam energy by 6% to 19%. Despite the benefits of adding niobium on patient dose reduction and on narrowing the beams' energy spectra, the beam can be overhardened. Adding niobium, therefore, strikes the best balance between radiation dose reduction and beam attenuation, with its risks of increased exposure times, motion blur, and diminished image contrast, when it is used at modest thicknesses (30 μm) and at lower kVp (70) settings. © 1995 Mosby-Year Book, Inc.
Resumo:
This work proposes a new isolated high power factor 12kW power supply based on an 18-pulse transformer arrangement. Three full-bridge converters are used for isolation and to balance the DC-link currents, without current sensing or a current controller. The topology provides a regulated DC output with a very simple control strategy. Simulation and experimental results are presented in this paper.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
High-frequency ultrasound is a non-invasive tool used in skin ageing research to assess dermis thickness and echogenicity. This study evaluated the reliability of a range of high-frequency ultrasound parameters and tested their correlation with age and a validated clinical scale for the assessment of forearm skin photoageing; the difference between two body sites according to environmental exposition patterns was also investigated. Twenty-three volunteers aged 28-82 years were divided into three groups according to forearm photoageing degree. A 20 MHz ultrasound unit was used to obtain cross-sectional images of the skin by two trained investigators on two different sites: the dorsal forearm (chronically photoexposed skin) and the proximal medial arm (non-photoexposed skin). Several echogenicity parameters were studied for each skin compartment: total dermis, upper dermis and lower dermis, and the ratio between upper and lower dermis. The intraclass correlation coefficient (for complete agreement) between investigators was higher for upper and total dermis echogenicity measures compared with the lower dermis. At the non-photoexposed site, the upper and lower dermis parameter ratio was better correlated with age. At the photoexposed area, total dermis parameters demonstrated higher correlations with clinical score. The authors discuss the choice of parameters for forearm photoageing assessment using high-frequency ultrasound.
Resumo:
Bone mass was only previously studied in juvenile dermatomyositis/polymyositis (DM/PM) patients. Therefore, the objective this study was to evaluate the prevalence of osteoporosis and fractures in adult DM/PM. Forty female DM/PM and 78 age-, gender-, and BMI-matched healthy controls were studied. Medical charts and clinical interviews of all patients were evaluated for demographic and clinical data, including disease activity, cumulative doses of glucocorticoid, menarche and menopause age, and fractures. Bone mineral density (BMD) using dual X-ray absorptiometry (DXA) were measured at lumbar spine (L1-L4) and hip. A decreased BMD in lumbar spine [0.902 (0.136) vs. 0.965 (0.141) g/cm(2), P = 0.022] and femoral neck [0.729 (0.12) vs. 0.784 (0.127) g/cm(2), P = 0.027] was observed in patients compared to controls. In addition, osteoporosis was more frequent in patients than in controls in both lumbar spine (20 vs. 3.8%, P = 0.007) and the femoral neck (27.5 vs. 10.3%, P = 0.016). Moreover, a high prevalence of fractures was found in patients in comparison to healthy subjects (17.9 vs. 5.1%, P = 0.040; OR = 3.92; CI 95%: 1.07-14.33). Comparing DM/PM patients with (n = 17) and without (n = 23) osteoporosis/fractures, significant differences were observed regarding age [56.8 (11.9) vs. 48.3 (13.2) years, P = 0.042], weight [62.05 (13.56) vs. 71.51 (11.46) kg, P = 0.022] and frequency of post menopausal women (94.1 vs. 65.2%, P = 0.0002). No differences were observed concerning height, lean mass, total fat mass, disease activity, mean value of creatine kinase, cumulative glucocorticoid dose, or bisphosphonate use. Logistic regression analysis revealed a negative association between the presence of osteoporosis/fractures and weight (OR: 0.92, 95% CI: 0.85-0.98; P = 0.016). This is the first study that analyzed bone mass in adult DM/PM patients and it demonstrated that about one quarter of these patients have osteoporosis/fracture.