Resumo:
Objectives: We performed a prospective clinical study of the cochleovestibular symptoms and the risk cofactors and characteristics of hearing loss in patients with type 1 diabetes.Methods: Group I consisted of 40 patients with type I diabetes, and group 2 consisted of 20 control subjects without diabetes. All participants answered a questionnaire, and their medical records were reviewed. They also were submitted to otorhinolaryngological examinations and to auditory tests (pure tone audiometry and acoustic immitance and auditory brain stem response [ABR] tests).Results: Dyslipidemia, hypertension, retinopathy, and diabetic neuropathy were not frequent in the patients of group 1, but incipient nephropathy was present in 47.5% of them. The most frequent cochleovestibular symptoms were tinnitus and hearing loss. Sensorineural hearing loss was found in 4 patients of group I and was predominantly bilateral, symmetric, and affecting the high frequencies, coexisting with normal vocal discrimination. These patients had a longer time from diabetes diagnosis and had poor glycemia control. A delay of ABR interpeak latency I-III was observed in 11.25% of the group I ears. All patients of group 2 presented normal audiograms and ABR tests.Conclusions: In group 1, the most frequent cochleovestibular symptoms were tinnitus and hearing loss. The sensorineural hearing loss was mild, symmetric, and predominantly high-frequency. A delay of ABR interpeak latencies was detected in the patients of group I who had normal audiometric thresholds.
Resumo:
A thrombin-like enzyme, named BjussuSP-I, isolated from Bothrops jararacussu snake venom, is an acidic single-chain glycoprotein with M-r = 61,000, pI similar to 3.8 and 6% sugar. BjussuSP-I shows high proteolytic activity upon synthetic substrates, such as S-2238 and S-2288. It also shows procoagulant and kallikrein-like activity, but is unable to act on platelets and plasmin. These activities are inhibited by specific inhibitors of this class of enzymes. The complete cDNA sequence of BjussuSP-I with 696 bp encodes open reading frames of 232 amino acid residues, which conserve the common domains of thrombin-like serine proteases. BjussuSP-I shows a high structural homology with other thrombin-like enzymes from snake venoms where common amino acid residues are identified as those corresponding to the catalytic site and subsites S1, S2 and S3 already reported. In this study, we also demonstrated the importance of N-linked glycans, to improve thrombin-like activity of BjussuSP-I toxin. (c) 2007 Elsevier Masson SAS. All rights reserved.
Resumo:
Statement of problem. The use of ultrasonic tips has become an alternative for cavity preparation. However, there are concerns about this type of device, particularly with respect to intrapulpal temperatures and cavity preparation time.Purpose. The purpose of this study was to analyze pulpal temperature increases generated by an ultrasonic cavity preparation with chemical vapor deposition (CVD) tips, in comparison to preparation with a high-speed handpiece with a diamond rotary cutting instrument. The time required to complete the cavity preparation with each system was also evaluated.Material and methods. Thermocouples were positioned in the pulp chamber of 20 extracted human third molars. Slot-type cavities (3 x 3 x 2 mm) were prepared on the buccal and the lingual surfaces of each tooth. The test groups were: high-speed cavity preparation with diamond rotary cutting instruments (n = 20) and ultrasonic cavity preparation with CVD points (n = 20). During cavity preparation, the increases In pulpal temperature, and the time required for the preparation, were recorded and analyzed by Student's t test for paired samples (alpha = .05).Results. The average pulpal temperature increases were 4.3 degrees C for the high-speed preparation and 3.8 degrees C for the ultrasonic preparation, which were statistically similar (P = .052). However, significant differences were found (P < .001) for the time expended (3.3 minutes for the high-speed bur and 13.77 minutes for the ultrasound device).Conclusions. The intrapulpal temperatures produced during cavity preparation by ultrasonic tips versus high-speed bur preparation were similar. However, the use of the ultrasonic device required 4 times longer for the completion of a cavity preparation.
Resumo:
The phenomenon of Fermi acceleration is addressed for a dissipative bouncing ball model with external stochastic perturbation. It is shown that the introduction of energy dissipation (inelastic collisions of the particle with the moving wall) is a sufficient condition to break down the process of Fermi acceleration. The phase transition from bounded to unbounded energy growth in the limit of vanishing dissipation is characterized.
Resumo:
The pressure field in a high-power klystron amplifier is investigated to scale the ionic vacuum pump used to maintain the ultra high-vacuum in the device in order to increase its life-time. The investigation is conducted using an 1.3 GHz, 100 A - 240 keV high-power klystron with five reentrant coaxial cavities, assembled in a cylindrical drift tube 1.2 m long. The diffusion equation is solved to the regime molecular flow to obtain the pressure profile along the axis of the klystron drift tube. The model, solved by both analytical and numerical procedures, is able to determine the pressure values in steady-state case. This work considers the specific conductance and all important gas sources, as in the degassing of the drift tube and cavities walls, cathode, and collector. For the drift tube degassing rate equals to q(deg) = 2x10(-12) (-)mbar.L.s(-1) cm(-2) (degassing rate per unit area), to cavities q(cavity) = 3x10(-13) mbar.L.s(-1)cm(-2), to the cathode q(cathode) = 6x10(-9)_mbar.L.s(-1) and to the collector q(collector) = 6x10(-9) mbar.L.s(-1), it was found that a 10 L.s(-1) ionic vacuum pump connected in the output waveguide wall is suitable. In this case, the pressure obtained in the cathode is p(cathode) = 6.3x10(-9) mbar, in the collector p(collector) = 2.7x10(-9) mbar, and in the output waveguide p = 2.1x10(-9) mbar. Although only the steady-state case is analyzed, some aspects that may be relevant in a transient situation, for instance, when the beam hits the drift tube walls, producing a gas burst, is also commented.
Resumo:
E-cadherin is a cell-cell adhesion molecule and low e-cadherin expression is related to invasiveness and may indicate a bad prognosis in mammary neoplasms. The expression of cell proliferation markers PCNA and especially Ki-67, has also proved to have a strong prognostic value in this tumor class. The expression of these markers was related to the clinical-pathological characteristics of 73 surgically removed mammary tumors in female dogs by immunohistochemistry. There was no statistical correlation between these markers and death by neoplasm, survival time and disease-free interval. However, the loss of e-cadherin expression and marked Ki-67 expression (p=0.016) were considered statistically significant for the diagnosis (p=0.032). When evaluated as independent factors, there was evidence of the relationship between the loss of e-cadherin expression and high PCNA expression with changes in the body status (divided into obese, normal and cachectic) of female dogs (p=0.030); there was also evidence of the relationship between pseudopregnancy and e-cadherin alone (p=0.021) and for ulceration and PCNA alone (p=0.035). The significant correlation between the markers expression and these well known prognostic factors used individually or in combination suggests their prognostic value in canine mammary tumors.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The pressure field of a high-power klystron amplifier in the cathode and anode region was investigated. The investigation was performed using a 1.3 GHz, 100 A and 240 kV high-power klystron with five reentrant coaxial cavities, assembled in cylindrical drift tube 1.2 m long. The diffusion equation in mathematical model was also solved by using a 3-D finite element method code, in order to obtain pressure profile in region of interest. The results show that density profile of molecules between cathode-anode region was determined, where cathode pressure is approximately 10% higher than anode pressure.
Resumo:
Objectives: This study measured the water flow commonly used in high-speed handpieces to evaluate the water flow's influence on temperature generation. Different flow speeds were evaluated between turbines that had different numbers of cooling apertures. Method and materials: Two water samples were collected from each high-speed handpiece at private practices and at the School of Dentistry at São José dos Campos. The first sample was collected at the customary flow and the second was collected with the terminal opened for maximum flow. The two samples were collected into weighed glass receptacles after 15 seconds of turbine operation. The glass receptacles were reweighed and the difference between weights was recorded to calculate the water flow in mL/min and for further statistical analysis. Results: The average water flow for 137 samples was 29.48 mL/min. The flow speeds obtained were 42.38 mL/min for turbines with one coolant aperture; 34.31 mL/min for turbines with two coolant apertures; and 30.44 mL/min for turbines with three coolant apertures. There were statistical differences between turbines with one and three coolant apertures (Tukey-Kramer multiple comparisons test with P < .05). Conclusion: Turbine handpieces with one cooling aperture distributed more water for the burs than high-speed handpieces with more than one aperture.
Resumo:
The possibility to install a getter vacuum pump and its feasible in the anode of a high-power klystron amplifier is investigated in order to decrease of the pressure in the gun and consequently increasing its lifetime. The study is conducted using a 1.3 GHz, 100 A and 240 kV high-power klystron with five reentrant coaxial cavities, assembled in a cylindrical drift tube 1.2 m long. This work takes into account the specific conductance of components of gun and all important gas sources, like the degassing of the drift tube, the cavity walls, the cathode, the anode, and the collector, as well the position and pumping speed of the getter vacuum pump in anode region. © 2006 IEEE.
Resumo:
This paper presents the development and experimental analysis of a special input stage converter for a Trolleybus type vehicle allowing its operation in AC (two wires, single-phase) or DC distribution networks. The architecture of proposed input stage converter is composed by five interleaved boost rectifiers operating in discontinuous conduction mode. Furthermore, due to the power lines characteristics, the proposed input power structure can act as AC to DC or as DC to DC converter providing a proper DC output voltage range required to the DC bus. When operation is AC to DC, the converter is capable to provide high power factor with reduced harmonic distortion for the input current, complying with the restrictions imposed by IEC 61000-3-4 standard. Finally, the main experimental results are presented in order to verify the feasibility of the proposed converter, demonstrating the benefits and the possibility for AC feeding system for trolleybus type vehicle. © 2010 IEEE.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Não disponível
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)