927 resultados para High Performance liquid chromatography coupled with mass spectrometry (LC-MS)
Resumo:
BACKGROUND: Flavonoid metabolites remain in blood for periods of time potentially long enough to allow interactions with cellular components of this tissue. It is well-established that flavonoids are metabolised within the intestine and liver into methylated, sulphated and glucuronidated counterparts, which inhibit platelet function. METHODOLOGY/PRINCIPAL FINDINGS: We demonstrate evidence suggesting platelets which contain metabolic enzymes, as an alternative location for flavonoid metabolism. Quercetin and a plasma metabolite of this compound, 4'-O-methyl quercetin (tamarixetin) were shown to gain access to the cytosolic compartment of platelets, using confocal microscopy. High performance liquid chromatography (HPLC) and mass spectrometry (MS) showed that quercetin was transformed into a compound with a mass identical to tamarixetin, suggesting that the flavonoid was methylated by catechol-O-methyl transferase (COMT) within platelets. CONCLUSIONS/SIGNIFICANCE: Platelets potentially mediate a third phase of flavonoid metabolism, which may impact on the regulation of the function of these cells by metabolites of these dietary compounds.
Resumo:
The microbiological bioassay, the UV-spectrophotometry and the high performance liquid chromatography (HPLC) methods for assaying sparfloxacin in tablets were compared. The accuracy, repeatability, and precision of each method was assessed and precise. All methods were reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate and precise. The microbiological bioassay and HPLC are more specific than UV-spectrophotometric analysis. However, the microbiological bioassay requires 20 h to get results, and HPLC is the most expensive analysis. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.
Resumo:
Two highly sensitive and selective methods based on gas chromatography coupled to mass spectrometry (GC-MS) in the selected ion monitoring (SIM) mode have been developed for the quantification of 2,6-dichlorophenol (2,6-DCP), a sex pheromone of the tick females of Anocentor nitens. Standard addition method and calibration curve techniques using 5-bromine-4-hydroxy-3- methoxybenzaldehyde (5-BrV) as internal standard (IS) afforded detection limit of 0.1ngml-1. The calibration curve was linear over the concentration range from 0.5 to 500ngml-1 for 2,6-DCP. Results show that the concentration range of sex pheromone in the extracts samples was 1.08-10.35ngml-1. The methods developed provided reliable procedures to determine amounts of 2,6-DCP present in ticks. © 2003 Elsevier B.V. All rights reserved.
Resumo:
Azo dyes, the most widely used family of synthetic dyes, are often employed as colorants in areas such as textiles, plastics, foods/drugs/cosmetics, and electronics. Following their use in industrial applications, azo dyes have been found in effluents and various receiving waters. Chemical treatment of effluents containing azo dyes includes disinfection using chlorine, which can generate compounds of varying eco/genotoxicity. Among the widely known commercial azo dyes for synthetic fibers is C.I. Disperse Red 1. While this dye is known to exist as a complex mixture, reports of eco/genotoxicity involve the purified form. Bearing in mind the potential for adverse synergistic effects arising from exposures to chemical mixtures, the aim of the present study was to characterize the components of commercial Disperse Red 1 and its chlorine-mediated decoloration products and to evaluate their ecotoxicity and mutagenicity. In conducting the present study, Disperse Red 1 was treated with chlorine gas, and the solution obtained was analyzed with the aid of LC-ESI-MS/MS to identify the components present, and then evaluated for ecotoxicity and mutagenicity, using Daphnia similis and Salmonella/microsome assays, respectively. The results of this study indicated that chlorination of Disperse Red 1 produced four chlorinated aromatic compounds as the main products and that the degradation products were more ecotoxic than the parent dye. These results suggest that a disinfection process using chlorine should be avoided for effluents containing hydrophobic azo dyes such commercial Disperse Red 1. © 2012 Elsevier B.V..
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The reproductive performance of cattle may be influenced by several factors, but mineral imbalances are crucial in terms of direct effects on reproduction. Several studies have shown that elements such as calcium, copper, iron, magnesium, selenium, and zinc are essential for reproduction and can prevent oxidative stress. However, toxic elements such as lead, nickel, and arsenic can have adverse effects on reproduction. In this paper, we applied a simple and fast method of multi-element analysis to bovine semen samples from Zebu and European classes used in reproduction programs and artificial insemination. Samples were analyzed by inductively coupled plasma spectrometry (ICP-MS) using aqueous medium calibration and the samples were diluted in a proportion of 1:50 in a solution containing 0.01% (vol/vol) Triton X-100 and 0.5% (vol/vol) nitric acid. Rhodium, iridium, and yttrium were used as the internal standards for ICP-MS analysis. To develop a reliable method of tracing the class of bovine semen, we used data mining techniques that make it possible to classify unknown samples after checking the differentiation of known-class samples. Based on the determination of 15 elements in 41 samples of bovine semen, 3 machine-learning tools for classification were applied to determine cattle class. Our results demonstrate the potential of support vector machine (SVM), multilayer perceptron (MLP), and random forest (RF) chemometric tools to identify cattle class. Moreover, the selection tools made it possible to reduce the number of chemical elements needed from 15 to just 8.
Resumo:
This thesis reports an integrated analytical approach for the study of physicochemical and biological properties of new synthetic bile acid (BA) analogues agonists of FXR and TGR5 receptors. Structure-activity data were compared with those previous obtained using the same experimental protocols on synthetic and natural occurring BA. The new synthetic BA analogues are classified in different groups according also to their potency as a FXR and TGR5 agonists: unconjugated and steroid modified BA and side chain modified BA including taurine or glycine conjugates and pseudo-conjugates (sulphonate and sulphate analogues). In order to investigate the relationship between structure and activity the synthetic analogues where admitted to a physicochemical characterization and to a preliminary screening for their pharmacokinetic and metabolism using a bile fistula rat model. Sensitive and accurate analytical methods have been developed for the quali-quantitative analysis of BA in biological fluids and sample used for physicochemical studies. Combined High Performance Liquid Chromatography Electrospray tandem mass spectrometry with efficient chromatographic separation of all studied BA and their metabolites have been optimized and validated. Analytical strategies for the identification of the BA and their minor metabolites have been developed. Taurine and glycine conjugates were identified in MS/MS by monitoring the specific ion transitions in multiple reaction monitoring (MRM) mode while all other metabolites (sulphate, glucuronic acid, dehydroxylated, decarboxylated or oxo) were monitored in a selected-ion reaction (SIR) mode with a negative ESI interface by the following ions. Accurate and precise data where achieved regarding the main physicochemical properties including solubility, detergency, lipophilicity and albumin binding . These studies have shown that minor structural modification greatly affect the pharmacokinetics and metabolism of the new analogues in respect to the natural BA and on turn their site of action, particularly where their receptor are located in the enterohepatic circulation.
Resumo:
One gram of onion added to the food of rats inhibits significantly (p < 0.05) bone resorption as assessed by the urinary excretion of tritium released from bone of 9-week-old rats prelabeled with tritiated tetracycline from weeks 1 to 6. To isolate and identify the bone resorption inhibiting compound from onion, onion powder was extracted and the extract fractionated by column chromatography and medium-pressure liquid chromatography. A single active peak was finally obtained by semipreparative high-performance liquid chromatography. The biological activity of the various fractions was tested in vitro on the activity of osteoclasts to form resorption pits on a mineralized substrate. Medium, containing the various fractions or the pure compound, was added to osteoclasts of new-born rats settled on ivory slices. After 24 h of incubation, the tartrate-resistant acid phosphatase positive multinucleated cells, that is, osteoclasts, were counted. Subsequently, the number of resorption pits was determined. Activity was calculated as the ratio of resorption pits/osteoclasts and was compared to a negative control, that is, medium containing 10% fetal bovine serum only and to calcitonin (10(-12) M) as a positive control. Finally, a single peak inhibited osteoclast activity significantly (p < 0.05). The structure of this compound was elucidated with high-performance liquid chromatography-electrospray ionization-mass spectrometry, time-of-flight electrospray ionization mass spectrometry, and nuclear magnetic resonance spectroscopy. The single peak was identified as gamma-L-glutamyl-trans-S-1-propenyl-L-cysteine sulfoxide (GPCS). It has a molecular mass of 306 Da and inhibits dose-dependently the resorption activity of osteoclasts, the minimal effective dose being approximately 2 mM. As no other peak displayed inhibitory activity, it likely is responsible for the effect of onion on bone resorption.
Resumo:
O objetivo do presente estudo foi utilizar o extrato de jabuticaba microencapsulado como corante e avaliar o seu potencial antimicrobiano e antioxidante em produtos cárneos embutidos do tipo linguiça frescal e mortadela, em substituição ao corante tradicionalmente utilizado carmim de cochonilha. Uma primeira etapa consistiu na avaliação in vitro da capacidade antioxidante e antimicrobiana do extrato de jabuticaba aquoso e microencapsulado. O extrato de jabuticaba foi obtido a partir do resíduo do despolpamento da fruta, com posterior desidratação (microencapsulação) por spray dryer, utilizando maltodextrina como agente carreador. A caracterização foi efetuada por determinação do teor de antocianinas e identificação destas por cromatografia líquida de alta eficiência (CLAE) e espectrometria de massas (MS), determinação da sua capacidade antioxidante pelos métodos Folin-Ciocalteu, capacidade redutora do ferro no plasma (FRAP) e capacidade antioxidante pelo radical DPPH. As características físicas avaliadas no extrato aquoso foram o valor de pH e o teor de sólidos solúveis. O potencial antimicrobiano foi determinado pelo método da concentração inibitória mínima (CIM) sobre as bactérias Staphylococcus aureus, Escherichia coli e Salmonella Enteritidis. O extrato de jabuticaba microencapsulado (EJM) foi utilizado para a elaboração de linguiça frescal e mortadela em duas diferentes concentrações: 2 e 4% de EJM para a linguiça frescal e 2% para mortadela. A linguiça frescal (à base de carne suína) e a mortadela (à base de carne bovina e carne mecanicamente separada de frango) foram avaliadas quanto à estabilidade durante armazenamento refrigerado a 1±1 e 4±1°C, por 15 e 56 dias, respectivamente. Os produtos foram caracterizados quanto à composição centesimal e foram realizadas análises físico-químicas, microbiológicas e sensoriais. Os resultados encontrados para a linguiça frescal confirmaram que o uso de 2% e 4% de EJM contribuíram para reduzir a oxidação lipídica durante os 15 dias de armazenamento e nas análises microbiológicas o EJM contribuiu para reduzir a contagem de microrganismos por quatro dias quando comparado com a linguiça controle (sem adição de EJM). A análise sensorial comprovou que 2% de EJM não comprometeu a maioria dos atributos sensoriais avaliados, com exceção da coloração mais escura. Recomenda-se, portanto, a utilização de 2% de EJM na produção de linguiça frescal. Nas mortadelas, os resultados não diferiram quando se comparou os produtos com 2% de EJM e sem adição do extrato (controle), porém, a utilização de 2% de EJM pode ser considerada uma alternativa interessante devido as demandas atuais por novas fontes de baixo custo e a utilização de pigmentos naturais que possam ser benéficos à saúde. Com estes resultados, pode-se dizer que o aproveitamento de cascas de jabuticaba oriundos do processamento da fruta, na forma de extrato microencapsulado, pode representar uma boa alternativa como corante natural, trazendo uma nova concepção da utilização de produtos mais saudáveis em linguiça frescal e mortadela.
Resumo:
O setor agroindustrial tem se expandido muito nos últimos anos, levando o país a um aumento na geração de resíduos agroindustriais, sendo que a maior parte deles ainda é descartada no meio ambiente, sem tratamento adequado, ou utilizada na alimentação animal, destinos que a priori, não geram ganhos econômicos para a agroindústria além de representarem gargalos logísticos e ambientais na sua disposição. Nesse sentido, o presente trabalho teve como objetivos otimizar o processo de extração de compostos bioativos, avaliar in vitro as atividades antioxidante, por meio da desativação de espécies reativas de oxigênio, e anti-inflamatória, bem como determinar a composição fenólica dos resíduos agroindustriais a saber: película de amendoim (Arachis hypogaea) (cultivares IAC886 e IAC505), pimenta-rosa (Schinus terebinthifolius Raddi) e pimenta-do-reino (Piper Nigrum L). O processo de otimização da extração de compostos antioxidantes foi realizado utilizando dois processos de extração, extração convencional e subcrítica, em delineamento composto central rotacional, utilizando como variáveis a temperatura e tempo e a pressão e temperatura, respectivamente, com os solventes etanol 80%, água e propilenoglicol 80%. Durante o processo de otimização a atividade antioxidante foi avaliada pelo método de sequestro do radical ABTS. Os melhores resultados foram obtidos para a extração convencional com os solventes etanol 80%, água e propilenoglicol 80%. A película de amendoim (IAC505) apresentou as maiores atividades antioxidantes (1.396,67, 580,44 e 859,89 μmol.g-1 em equivalentes de trolox, para os solventes etanol 80%, água e propilenoglicol 80%, respectivamente). A partir dos resultados obtidos para os solventes testados, utilizando a extração convencional, foram feitas outras análises de atividade antioxidante considerando o tempo e temperatura ideal de extração. Foram realizadas análises de avaliação da capacidade de redução de Folin-Ciocalteau e potencial de desativação dos radicais livres sintéticos (DPPH e ABTS) e espécies reativas de oxigênio (radicais peroxila, superóxido e ácido hipocloroso). O solvente de extração que apresentou melhores resultados em todos os ensaios foi o etanol 80%, sendo, portanto o solvente utilizado nas análises subsequentes. A partir da definição do melhor sistema extrator foram realizadas análises da composição fenólica, por meio das técnicas de cromatografia líquida de alta eficiência em modo analítico (HPLC-RP), cromatografia gasosa acoplada com espectrometria de massas (GC-MS), e avaliação in vitro da atividade anti-inflamatória. Foram identificados nos resíduos estudados procianidinas B1 e B2, ácido p-cumárico, miricetina, ácido ferúlico, ácido siríngico, ácido sinápico, epicatequina e catequina. A pimenta-do-reino diminui significativamente os níveis de TNF-α e nitritos, reduzindo assim o processo inflamatório gerado. Os resultados obtidos neste trabalho demonstram que estes resíduos agroindústrias possuem grande potencial biológico, podendo assim ser melhores aproveitados tanto pela indústria de alimentos quanto pela indústria farmacêutica.
Resumo:
The complex nature of venom from spider species offers a unique natural source of potential pharmacological tools and therapeutic leads. The increased interest in spider venom molecules requires reproducible and precise identification methods. The current taxonomy of the Australian Funnel-web spiders is incomplete, and therefore, accurate identification of these spiders is difficult. Here, we present a study of venom from numerous morphologically similar specimens of the Hadronyche infensa species group collected from a variety of geographic locations in southeast Queensland. Analysis of the crude venoms using online reversed-phase high performance liquid chromatography/electrospray ionisation mass spectrometry (rp-HPLC/ESI-MS) revealed that the venom profiles provide a useful means of specimen identification, from the species level to species variants. Tables defining the descriptor molecules for each group of specimens were constructed and provided a quick reference of the relationship between one specimen and another. The study revealed that the morphologically similar specimens from the southeast Queensland region are a number of different species/species variants. Furthermore, the study supports aspects of the current taxonomy with respect to the H. infensa species group. Analysis of Australian Funnel-web spider venom by rp-HPLC/ESI-MS provides a rapid and accurate method of species/species variant identification. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
This work describes the construction and testing of a simple pressurized solvent extraction (PSE) system. A mixture of acetone:water (80:20), 80 ºC and 103.5 bar, was used to extract two herbicides (Diuron and Bromacil) from a sample of polluted soil, followed by identification and quantification by high-performance liquid chromatography coupled with diode array detector (HPLC-DAD). The system was also used to extract soybean oil (70 ºC and 69 bar) using pentane. The extracted oil was weighed and characterized through the fatty acid methyl ester analysis (myristic (< 0.3%), palmitic (16.3%), stearic (2.8%), oleic (24.5%), linoleic (46.3%), linolenic (9.6%), araquidic (0.3%), gadoleic (< 0.3%), and behenic (0.3%) acids) using high-resolution gas chromatography with flame ionization detection (HRGC-FID). PSE results were compared with those obtained using classical procedures: Soxhlet extraction for the soybean oil and solid-liquid extraction followed by solid-phase extraction (SLE-SPE) for the herbicides. The results showed: 21.25 ± 0.36% (m/m) of oil in the soybeans using the PSE system and 21.55 ± 0.65% (m/m) using the soxhlet extraction system; extraction efficiency (recovery) of herbicides Diuron and Bromacil of 88.7 ± 4.5% and 106.6 ± 8.1%, respectively, using the PSE system, and 96.8 ± 1.0% and 94.2 ± 3.9%, respectively, with the SLP-SPE system; limit of detection (LOD) and limit of quantification (LOQ) for Diuron of 0.012 mg kg-1 and 0.040 mg kg-1, respectively; LOD and LOQ for Bromacil of 0.025 mg kg-1 and 0.083 mg kg-1, respectively. The linearity used ranged from 0.04 to 1.50 mg L-1 for Diuron and from 0.08 to 1.50 mg L-1 for Bromacil. In conclusion, using the PSE system, due to high pressure and temperature, it is possible to make efficient, fast extractions with reduced solvent consumption in an inert atmosphere, which prevents sample and analyte decomposition.
Resumo:
In the International Olympic Committee (IOC) accredited laboratories, specific methods have been developed to detect anabolic steroids in athletes' urine. The technique of choice to achieve this is gas-chromatography coupled with mass spectrometry (GC-MS). In order to improve the efficiency of anti-doping programmes, the laboratories have defined new analytical strategies. The final sensitivity of the analytical procedure can be improved by choosing new technologies for use in detection, such as tandem mass spectrometry (MS-MS) or high resolution mass spectrometry (HRMS). A better sample preparation using immuno-affinity chromatography (IAC) is also a good tool for improving sensitivity. These techniques are suitable for the detection of synthetic anabolic steroids whose structure is not found naturally in the human body. The more and more evident use, on a large scale, of substances chemically similar to the endogenous steroids obliges both the laboratory and the sports authorities to use the steroid profile of the athlete in comparison with reference ranges from a population or with intraindividual reference values.
Resumo:
«Quel est l'âge de cette trace digitale?» Cette question est relativement souvent soulevée au tribunal ou lors d'investigations, lorsque la personne suspectée admet avoir laissé ses empreintes digitales sur une scène de crime mais prétend l'avoir fait à un autre moment que celui du crime et pour une raison innocente. Toutefois, aucune réponse ne peut actuellement être donnée à cette question, puisqu'aucune méthodologie n'est pour l'heure validée et acceptée par l'ensemble de la communauté forensique. Néanmoins, l'inventaire de cas américains conduit dans cette recherche a montré que les experts fournissent tout de même des témoignages au tribunal concernant l'âge de traces digitales, même si ceux-‐ci sont majoritairement basés sur des paramètres subjectifs et mal documentés. Il a été relativement aisé d'accéder à des cas américains détaillés, ce qui explique le choix de l'exemple. Toutefois, la problématique de la datation des traces digitales est rencontrée dans le monde entier, et le manque de consensus actuel dans les réponses données souligne la nécessité d'effectuer des études sur le sujet. Le but de la présente recherche est donc d'évaluer la possibilité de développer une méthode de datation objective des traces digitales. Comme les questions entourant la mise au point d'une telle procédure ne sont pas nouvelles, différentes tentatives ont déjà été décrites dans la littérature. Cette recherche les a étudiées de manière critique, et souligne que la plupart des méthodologies reportées souffrent de limitations prévenant leur utilisation pratique. Néanmoins, certaines approches basées sur l'évolution dans le temps de composés intrinsèques aux résidus papillaires se sont montrées prometteuses. Ainsi, un recensement détaillé de la littérature a été conduit afin d'identifier les composés présents dans les traces digitales et les techniques analytiques capables de les détecter. Le choix a été fait de se concentrer sur les composés sébacés détectés par chromatographie gazeuse couplée à la spectrométrie de masse (GC/MS) ou par spectroscopie infrarouge à transformée de Fourier. Des analyses GC/MS ont été menées afin de caractériser la variabilité initiale de lipides cibles au sein des traces digitales d'un même donneur (intra-‐variabilité) et entre les traces digitales de donneurs différents (inter-‐variabilité). Ainsi, plusieurs molécules ont été identifiées et quantifiées pour la première fois dans les résidus papillaires. De plus, il a été déterminé que l'intra-‐variabilité des résidus était significativement plus basse que l'inter-‐variabilité, mais que ces deux types de variabilité pouvaient être réduits en utilisant différents pré-‐ traitements statistiques s'inspirant du domaine du profilage de produits stupéfiants. Il a également été possible de proposer un modèle objectif de classification des donneurs permettant de les regrouper dans deux classes principales en se basant sur la composition initiale de leurs traces digitales. Ces classes correspondent à ce qui est actuellement appelé de manière relativement subjective des « bons » ou « mauvais » donneurs. Le potentiel d'un tel modèle est élevé dans le domaine de la recherche en traces digitales, puisqu'il permet de sélectionner des donneurs représentatifs selon les composés d'intérêt. En utilisant la GC/MS et la FTIR, une étude détaillée a été conduite sur les effets de différents facteurs d'influence sur la composition initiale et le vieillissement de molécules lipidiques au sein des traces digitales. Il a ainsi été déterminé que des modèles univariés et multivariés pouvaient être construits pour décrire le vieillissement des composés cibles (transformés en paramètres de vieillissement par pré-‐traitement), mais que certains facteurs d'influence affectaient ces modèles plus sérieusement que d'autres. En effet, le donneur, le substrat et l'application de techniques de révélation semblent empêcher la construction de modèles reproductibles. Les autres facteurs testés (moment de déposition, pression, température et illumination) influencent également les résidus et leur vieillissement, mais des modèles combinant différentes valeurs de ces facteurs ont tout de même prouvé leur robustesse dans des situations bien définies. De plus, des traces digitales-‐tests ont été analysées par GC/MS afin d'être datées en utilisant certains des modèles construits. Il s'est avéré que des estimations correctes étaient obtenues pour plus de 60 % des traces-‐tests datées, et jusqu'à 100% lorsque les conditions de stockage étaient connues. Ces résultats sont intéressants mais il est impératif de conduire des recherches supplémentaires afin d'évaluer les possibilités d'application de ces modèles dans des cas réels. Dans une perspective plus fondamentale, une étude pilote a également été effectuée sur l'utilisation de la spectroscopie infrarouge combinée à l'imagerie chimique (FTIR-‐CI) afin d'obtenir des informations quant à la composition et au vieillissement des traces digitales. Plus précisément, la capacité de cette technique à mettre en évidence le vieillissement et l'effet de certains facteurs d'influence sur de larges zones de traces digitales a été investiguée. Cette information a ensuite été comparée avec celle obtenue par les spectres FTIR simples. Il en a ainsi résulté que la FTIR-‐CI était un outil puissant, mais que son utilisation dans l'étude des résidus papillaires à des buts forensiques avait des limites. En effet, dans cette recherche, cette technique n'a pas permis d'obtenir des informations supplémentaires par rapport aux spectres FTIR traditionnels et a également montré des désavantages majeurs, à savoir de longs temps d'analyse et de traitement, particulièrement lorsque de larges zones de traces digitales doivent être couvertes. Finalement, les résultats obtenus dans ce travail ont permis la proposition et discussion d'une approche pragmatique afin d'aborder les questions de datation des traces digitales. Cette approche permet ainsi d'identifier quel type d'information le scientifique serait capable d'apporter aux enquêteurs et/ou au tribunal à l'heure actuelle. De plus, le canevas proposé décrit également les différentes étapes itératives de développement qui devraient être suivies par la recherche afin de parvenir à la validation d'une méthodologie de datation des traces digitales objective, dont les capacités et limites sont connues et documentées. -- "How old is this fingermark?" This question is relatively often raised in trials when suspects admit that they have left their fingermarks on a crime scene but allege that the contact occurred at a time different to that of the crime and for legitimate reasons. However, no answer can be given to this question so far, because no fingermark dating methodology has been validated and accepted by the whole forensic community. Nevertheless, the review of past American cases highlighted that experts actually gave/give testimonies in courts about the age of fingermarks, even if mostly based on subjective and badly documented parameters. It was relatively easy to access fully described American cases, thus explaining the origin of the given examples. However, fingermark dating issues are encountered worldwide, and the lack of consensus among the given answers highlights the necessity to conduct research on the subject. The present work thus aims at studying the possibility to develop an objective fingermark dating method. As the questions surrounding the development of dating procedures are not new, different attempts were already described in the literature. This research proposes a critical review of these attempts and highlights that most of the reported methodologies still suffer from limitations preventing their use in actual practice. Nevertheless, some approaches based on the evolution of intrinsic compounds detected in fingermark residue over time appear to be promising. Thus, an exhaustive review of the literature was conducted in order to identify the compounds available in the fingermark residue and the analytical techniques capable of analysing them. It was chosen to concentrate on sebaceous compounds analysed using gas chromatography coupled with mass spectrometry (GC/MS) or Fourier transform infrared spectroscopy (FTIR). GC/MS analyses were conducted in order to characterize the initial variability of target lipids among fresh fingermarks of the same donor (intra-‐variability) and between fingermarks of different donors (inter-‐variability). As a result, many molecules were identified and quantified for the first time in fingermark residue. Furthermore, it was determined that the intra-‐variability of the fingermark residue was significantly lower than the inter-‐variability, but that it was possible to reduce both kind of variability using different statistical pre-‐ treatments inspired from the drug profiling area. It was also possible to propose an objective donor classification model allowing the grouping of donors in two main classes based on their initial lipid composition. These classes correspond to what is relatively subjectively called "good" or "bad" donors. The potential of such a model is high for the fingermark research field, as it allows the selection of representative donors based on compounds of interest. Using GC/MS and FTIR, an in-‐depth study of the effects of different influence factors on the initial composition and aging of target lipid molecules found in fingermark residue was conducted. It was determined that univariate and multivariate models could be build to describe the aging of target compounds (transformed in aging parameters through pre-‐ processing techniques), but that some influence factors were affecting these models more than others. In fact, the donor, the substrate and the application of enhancement techniques seemed to hinder the construction of reproducible models. The other tested factors (deposition moment, pressure, temperature and illumination) also affected the residue and their aging, but models combining different values of these factors still proved to be robust. Furthermore, test-‐fingermarks were analysed with GC/MS in order to be dated using some of the generated models. It turned out that correct estimations were obtained for 60% of the dated test-‐fingermarks and until 100% when the storage conditions were known. These results are interesting but further research should be conducted to evaluate if these models could be used in uncontrolled casework conditions. In a more fundamental perspective, a pilot study was also conducted on the use of infrared spectroscopy combined with chemical imaging in order to gain information about the fingermark composition and aging. More precisely, its ability to highlight influence factors and aging effects over large areas of fingermarks was investigated. This information was then compared with that given by individual FTIR spectra. It was concluded that while FTIR-‐ CI is a powerful tool, its use to study natural fingermark residue for forensic purposes has to be carefully considered. In fact, in this study, this technique does not yield more information on residue distribution than traditional FTIR spectra and also suffers from major drawbacks, such as long analysis and processing time, particularly when large fingermark areas need to be covered. Finally, the results obtained in this research allowed the proposition and discussion of a formal and pragmatic framework to approach the fingermark dating questions. It allows identifying which type of information the scientist would be able to bring so far to investigators and/or Justice. Furthermore, this proposed framework also describes the different iterative development steps that the research should follow in order to achieve the validation of an objective fingermark dating methodology, whose capacities and limits are well known and properly documented.