978 resultados para Hedwig and the Angry Inch (Motion picture)
Resumo:
Coxsackie B viruses types 1-6 (CVB1-6) occur worldwide and cause a broad spectrum of diseases, including myocarditis and aseptic meningitis. Although renal damage due to CVB has been suspected since the 1950s, these agents are only rarely searched for in today's clinical nephrological practice. Nevertheless, CVB can infect mesangial cells. Furthermore, infections with these viruses lead to a histological picture resembling mesangioproliferative glomerulonephritis and IgA-nephropathy in mice. In the present article, we provide an overview of this largely neglected topic, and of the slowly and steadily increasing evidence suggesting a link between coxsackieviral infections and kidney diseases.
Resumo:
Femoroacetabular impingement due to metaphyseal prominence is associated with the slippage in patients with slipped capital femoral epiphysis (SCFE), but it is unclear whether the changes in femoral metaphysis morphology are associated with range of motion (ROM) changes or type of impingement. We asked whether the femoral head-neck junction morphology influences ROM analysis and type of impingement in addition to the slip angle and the acetabular version. We analyzed in 31 patients with SCFE the relationship between the proximal femoral morphology and limitation in ROM due to impingement based on simulated ROM of preoperative CT data. The ROM was analyzed in relation to degree of slippage, femoral metaphysis morphology, acetabular version, and pathomechanical terms of "impaction" and "inclusion." The ROM in the affected hips was comparable to that in the unaffected hips for mild slippage and decreased for slippage of more than 30 degrees. The limitation correlated with changes in the metaphysic morphology and changed acetabular version. Decreased head-neck offset in hips with slip angles between 30 degrees and 50 degrees had restricted ROM to nearly the same degree as in severe SCFE. Therefore, in addition to the slip angle, the femoral metaphysis morphology should be used as criteria for reconstructive surgery.
Resumo:
The emergence of the state in Europe is a topic that has engaged historians since the establishment of the discipline of history. Yet the primary focus of has nearly always been to take a top-down approach, whereby the formation and consolidation of public institutions is viewed as the outcome of activities by princes and other social elites. Yet, as the essays in this collection show, such an approach does not provide a complete picture. By investigating the importance of local and individual initiatives that contributed to state building from the late middle ages through to the nineteenth century, this volume shows how popular pressure could influence those in power to develop new institutional structures. By not privileging the role of warfare and of elite coercion for state building, it is possible to question the traditional top-down model and explore the degree to which central agencies might have been more important for state representation than for state practice. The studies included in this collection treat many parts of Europe and deal with different phases in the period between the late middle ages and the nineteenth century. Beginning with a critical review of state historiography, the introduction then sets out the concept of 'empowering interactions' which is then explored in the subsequent case studies and a number of historiographical, methodological and theoretical essays. Taken as a whole this collection provides a fascinating platform to reconsider the relationships between top-down and bottom-up processes in the history of the European state.
Resumo:
The Austrian philosopher Ludwig Wittgenstein famously proposed a style of philosophy that was directed against certain pictures [bild] that tacitly direct our language and forms of life. His aim was to show the fly the way out of the fly bottle and to fight against the bewitchment of our intelligence by means of language: “A picture held us captive. And we could not get outside it, for it lay in our language and language seemed to repeat it to us inexorably” (Wittgenstein 1953, 115). In this context Wittgenstein is talking of philosophical pictures, deep metaphors that have structured our language but he does also use the term picture in other contexts (see Owen 2003, 83). I want to appeal to Wittgenstein in my use of the term ideology to refer to the way in which powerful underlying metaphors in neoclassical economics have a strong rhetorical and constitutive force at the level of public policy. Indeed, I am specifically speaking of the notion of ‘the performative’ in Wittgenstein and Austin. The notion of the knowledge economy has a prehistory in Hayek (1937; 1945) who founded the economics of knowledge in the 1930s, in Machlup (1962; 1970), who mapped the emerging employment shift to the US service economy in the early 1960s, and to sociologists Bell (1973) and Touraine (1974) who began to tease out the consequences of these changes for social structure in the post-industrial society in the early 1970s. The term has been taken up since by economists, sociologists, futurists and policy experts recently to explain the transition to the so-called ‘new economy’. It is not just a matter of noting these discursive strands in the genealogy of the ‘knowledge economy’ and related or cognate terms. We can also make a number of observations on the basis of this brief analysis. First, there has been a succession of terms like ‘postindustrial economy’, ‘information economy’, ‘knowledge economy’, ‘learning economy’, each with a set of related concepts emphasising its social, political, management or educational aspects. Often these literatures are not cross-threading and tend to focus on only one aspect of phenomena leading to classic dichotomies such as that between economy and society, knowledge and information. Second, these terms and their family concepts are discursive, historical and ideological products in the sense that they create their own meanings and often lead to constitutive effects at the level of policy. Third, while there is some empirical evidence to support claims concerning these terms, at the level of public policy these claims are empirically underdetermined and contain an integrating, visionary or futures component, which necessarily remains untested and is, perhaps, in principle untestable.
Resumo:
Methods for optical motion capture often require timeconsuming manual processing before the data can be used for subsequent tasks such as retargeting or character animation. These processing steps restrict the applicability of motion capturing especially for dynamic VR-environments with real time requirements. To solve these problems, we present two additional, fast and automatic processing stages based on our motion capture pipeline presented in [HSK05]. A normalization step aligns the recorded coordinate systems with the skeleton structure to yield a common and intuitive data basis across different recording sessions. A second step computes a parameterization based on automatically extracted main movement axes to generate a compact motion description. Our method does not restrict the placement of marker bodies nor the recording setup, and only requires a short calibration phase.
Resumo:
The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.
Resumo:
Hereditary thrombotic thrombocytopenic purpura, Upshaw-Schulman syndrome, ADAMTS13 Hereditary thrombotic thrombocytopenic purpura (TTP), also known as Upshaw-Schulman syndrome, is a rare recessively inherited disease. Underlying is a severe constitutional deficiency of the von Willebrand factor-cleaving protease, ADAMTS13, due to compound heterozygous or homozygous mutations in the ADAMTS13 gene. The clinical picture is variable and more and more patients with an adult-onset are diagnosed. In the majority of countries the only available treatment is plasma, which when administered regularly can efficiently prevent acute disease bouts. The decision to initiate regular prophylaxis is often not easy, as evidence based guidelines and long term outcome data are lacking. Through the hereditary TTP registry (www.ttpregistry.net, ClinicalTrials.gov identifier: NCT01257269), which was initiated in 2006 and is open to all patients diagnosed with Upshaw-Schulman syndrome and their family members, we aim to gain further information and insights into this rare disease, which eventually will help to improve clinical management of affected patients.
Resumo:
This chapter is a contribution to the Palgrave Handbook of European Media Policy (co-edited by Pauwels, Donders & Loisen). It is the chapter’s purpose to examine the proponents of the cultural exception policy, their strategies and demands, and to explore how they came to be reflected in the law and policy of the World Trade Organization (WTO). The chapter also looks at the current state of affairs, as although WTO law has not undergone any substantial amendments since its entry into force in 1995, the media landscape has in the meantime been truly transformed, in some aspects in a revolutionary manner. The broader picture of global governance has not remained still either, with new and emergent powers, changing mechanisms of rule-making and taking.
Resumo:
The Princeton Ocean Model is used to study the circulation in the South China Sea (SCS) and its seasonal transition. Kuroshio enters ( leaves) the SCS through the southern ( northern) portion of the Luzon Strait. The annually averaged net volume flux through the Luzon Strait is similar to2 Sv into the SCS with seasonal reversals. The inflow season is from May to January with the maximum intrusion of Kuroshio water reaching the western SCS during fall in compensation of summertime surface offshore transport associated with coastal upwelling. From February to April the net transport reverses from the SCS to the Pacific. The intruded Kuroshio often forms an anticyclonic current loop west of the Luzon Strait. The current loop separates near the Dongsha Islands with the northward branch continuously feeding the South China Sea Warm Current (SCSWC) near the shelf break and the westward branch becoming the South China Sea Branch of Kuroshio on the slope, which is most apparent in the fall. The SCSWC appears from December to February on the seaward side of the shelf break, flowing eastward against the prevailing wind. Diagnosis shows that the onshore Ekman transport due to northeasterly monsoon generates upwelling when moving upslope, and the particular distributions of the density and sea level associated with the cross shelf motion supports the SCSWC.
Resumo:
OBJECTIVE To compare the archwires inserted during the final stages of the orthodontic treatment with the generated moments at 0.018- and 0.022-inch brackets. MATERIALS AND METHODS The same bracket type, in terms of prescription, was evaluated in both slot dimensions. The brackets were bonded on two identical maxillary acrylic resin models, and each model was mounted on the orthodontic measurement and simulation system. Ten 0.017 × 0.025-inch TMA and ten 0.017 × 0.025-inch stainless steel archwires were evaluated in the 0.018-inch brackets. In the 0.022-inch brackets, ten 0.019 × 0.025-inch TMA and ten 0.019 × 0.025-inch stainless steel archwires were measured. A 15° buccal root torque (+15°) and then a 15° palatal root torque (-15°) were gradually applied to the right central incisor bracket, and the moments were recorded at these positions. A t-test was conducted to compare the generated moments between wires within the 0.018- and 0.022-inch bracket groups separately. RESULTS The 0.017 × 0.025-inch archwire in the 0.018-inch brackets generated mean moments of 9.25 Nmm and 14.2 Nmm for the TMA and stainless steel archwires, respectively. The measured moments in the 0.022-inch brackets with the 0.019 × 0.025-inch TMA and stainless steel archwires were 6.6 Nmm and 9.3 Nmm, respectively. CONCLUSION The 0.017 × 0.025-inch stainless steel and β-Ti archwires in the 0.018-inch slot generated higher moments than the 0.019 × 0.025-inch archwires because of lower torque play. This difference is exaggerated in steel archwires, in comparison with the β-Ti, because of differences in stiffness. The differences of maximum moments between the archwires of the same cross-section but different alloys were statistically significant at both slot dimensions.
Resumo:
BACKGROUND Knee pain is associated with radiographic knee osteoarthritis, but the relationships between physical examination, pain and radiographic features are unclear. OBJECTIVE To examine whether deficits in knee extension or flexion were associated with radiographic severity and pain during clinical examination in persons with knee pain or radiographic features of osteoarthritis. DESIGN Cross-sectional data of the Somerset and Avon Survey of Health (SASH) cohort study. METHODS Participants with knee pain or radiographic features of osteoarthritis were included. We assessed the range of passive knee flexion and extension, pain on movement and Kellgren and Lawrence (K/L) grades. Odds ratios were calculated for the association between range of motion and pain as well as radiographic severity. RESULTS/FINDINGS Of 1117 participants with a clinical assessment, 805 participants and 1530 knees had complete data and were used for this analysis. Pain and radiographic changes were associated with limited range of motion. In knees with pain on passive movement, extension and flexion were reduced per one grade of K/L by -1.4° (95% CI -2.2 to -0.5) and -1.6° (95% CI -2.8 to -0.4), while in knees without pain the reduction was -0.3° (95% CI -0.6 to -0.1) (extension) and -1.1° (-1.8 to -0.3) (flexion). The interaction of pain with K/L was significant (p = 0.021) for extension but not for flexion (p = 0.333). CONCLUSIONS Pain during passive movement, which may be an indicator of reversible soft-tissue changes, e.g., reversible through physical therapy, is independently associated with reduced flexion and extension of the knee.
Resumo:
We investigated the effects of angry prosody, varying focus of attention, and laterality of presentation of angry prosody on peripheral nervous system activity. Participants paid attention to either their left or their right ear while performing a sex discrimination task on dichotically presented pseudo-words. These pseudo-words were characterized by either angry or neutral prosody and presented stereophonically (anger/neutral, neutral/anger, or neutral/neutral, for the left/right ear, respectively). Reaction times and physiological responses (heart period, skin conductance, finger and forehead temperature) in this study were differentially sensitive to the effects of anger versus neutral prosody, varying focus of attention, and laterality of presentation of angry prosody.
Resumo:
In this chapter I explore the ambiguous, contradictory and often transient ways the past enters into our lives. I shed light on the interplay of mobility and temporality in the lifeworlds of two Somalis who left Mogadishu with the outbreak of the war in the 1990s. Looking into the ways they actively make sense of this crucial ‘memory-place’ (Ricoeur 2004), a place that that has been turned into a landscape of ruins and rubble, alternative understandings of memory and temporality will emerge. Instead of producing a continuum between here and there, and now and then, the stories and photographs discussed in this chapter form dialectical images – images that refuse to be woven into a coherent picture of the past. By emphasising the dialectical ways these two individuals make sense of Mogadishu’s past and presence, I am following Walter Benjamin’s cue to rethink deeply modern analytical categories such as history, memory and temporality by highlighting the brief, fragmented moments of their appearance in everyday life.
Resumo:
Alexander's Dictum--"to be is to have causal powers"--appears to furnish an argument against the reality of familiar medium-sized objects. For every time a familiar object appears to cause a familiar macro-event, it sets up a rival claim by its component microparticles to have caused the complex swarm of microphysical events that composes into that macro-event. But this argument, argues this paper, wrongly assumes that even after familiar objects are removed from the picture, there is a phenomenon of joint causation which unites all and only the microparticles within each familiar object.
Resumo:
Las técnicas de cirugía de mínima invasión (CMI) se están consolidando hoy en día como alternativa a la cirugía tradicional, debido a sus numerosos beneficios para los pacientes. Este cambio de paradigma implica que los cirujanos deben aprender una serie de habilidades distintas de aquellas requeridas en cirugía abierta. El entrenamiento y evaluación de estas habilidades se ha convertido en una de las mayores preocupaciones en los programas de formación de cirujanos, debido en gran parte a la presión de una sociedad que exige cirujanos bien preparados y una reducción en el número de errores médicos. Por tanto, se está prestando especial atención a la definición de nuevos programas que permitan el entrenamiento y la evaluación de las habilidades psicomotoras en entornos seguros antes de que los nuevos cirujanos puedan operar sobre pacientes reales. Para tal fin, hospitales y centros de formación están gradualmente incorporando instalaciones de entrenamiento donde los residentes puedan practicar y aprender sin riesgos. Es cada vez más común que estos laboratorios dispongan de simuladores virtuales o simuladores físicos capaces de registrar los movimientos del instrumental de cada residente. Estos simuladores ofrecen una gran variedad de tareas de entrenamiento y evaluación, así como la posibilidad de obtener información objetiva de los ejercicios. Los diferentes estudios de validación llevados a cabo dan muestra de su utilidad; pese a todo, los niveles de evidencia presentados son en muchas ocasiones insuficientes. Lo que es más importante, no existe un consenso claro a la hora de definir qué métricas son más útiles para caracterizar la pericia quirúrgica. El objetivo de esta tesis doctoral es diseñar y validar un marco de trabajo conceptual para la definición y validación de entornos para la evaluación de habilidades en CMI, en base a un modelo en tres fases: pedagógica (tareas y métricas a emplear), tecnológica (tecnologías de adquisición de métricas) y analítica (interpretación de la competencia en base a las métricas). Para tal fin, se describe la implementación práctica de un entorno basado en (1) un sistema de seguimiento de instrumental fundamentado en el análisis del vídeo laparoscópico; y (2) la determinación de la pericia en base a métricas de movimiento del instrumental. Para la fase pedagógica se diseñó e implementó un conjunto de tareas para la evaluación de habilidades psicomotoras básicas, así como una serie de métricas de movimiento. La validación de construcción llevada a cabo sobre ellas mostró buenos resultados para tiempo, camino recorrido, profundidad, velocidad media, aceleración media, economía de área y economía de volumen. Adicionalmente, los resultados obtenidos en la validación de apariencia fueron en general positivos en todos los grupos considerados (noveles, residentes, expertos). Para la fase tecnológica, se introdujo el EVA Tracking System, una solución para el seguimiento del instrumental quirúrgico basado en el análisis del vídeo endoscópico. La precisión del sistema se evaluó a 16,33ppRMS para el seguimiento 2D de la herramienta en la imagen; y a 13mmRMS para el seguimiento espacial de la misma. La validación de construcción con una de las tareas de evaluación mostró buenos resultados para tiempo, camino recorrido, profundidad, velocidad media, aceleración media, economía de área y economía de volumen. La validación concurrente con el TrEndo® Tracking System por su parte presentó valores altos de correlación para 8 de las 9 métricas analizadas. Finalmente, para la fase analítica se comparó el comportamiento de tres clasificadores supervisados a la hora de determinar automáticamente la pericia quirúrgica en base a la información de movimiento del instrumental, basados en aproximaciones lineales (análisis lineal discriminante, LDA), no lineales (máquinas de soporte vectorial, SVM) y difusas (sistemas adaptativos de inferencia neurodifusa, ANFIS). Los resultados muestran que en media SVM presenta un comportamiento ligeramente superior: 78,2% frente a los 71% y 71,7% obtenidos por ANFIS y LDA respectivamente. Sin embargo las diferencias estadísticas medidas entre los tres no fueron demostradas significativas. En general, esta tesis doctoral corrobora las hipótesis de investigación postuladas relativas a la definición de sistemas de evaluación de habilidades para cirugía de mínima invasión, a la utilidad del análisis de vídeo como fuente de información y a la importancia de la información de movimiento de instrumental a la hora de caracterizar la pericia quirúrgica. Basándose en estos cimientos, se han de abrir nuevos campos de investigación que contribuyan a la definición de programas de formación estructurados y objetivos, que puedan garantizar la acreditación de cirujanos sobradamente preparados y promocionen la seguridad del paciente en el quirófano. Abstract Minimally invasive surgery (MIS) techniques have become a standard in many surgical sub-specialties, due to their many benefits for patients. However, this shift in paradigm implies that surgeons must acquire a complete different set of skills than those normally attributed to open surgery. Training and assessment of these skills has become a major concern in surgical learning programmes, especially considering the social demand for better-prepared professionals and for the decrease of medical errors. Therefore, much effort is being put in the definition of structured MIS learning programmes, where practice with real patients in the operating room (OR) can be delayed until the resident can attest for a minimum level of psychomotor competence. To this end, skills’ laboratory settings are being introduced in hospitals and training centres where residents may practice and be assessed on their psychomotor skills. Technological advances in the field of tracking technologies and virtual reality (VR) have enabled the creation of new learning systems such as VR simulators or enhanced box trainers. These systems offer a wide range of tasks, as well as the capability of registering objective data on the trainees’ performance. Validation studies give proof of their usefulness; however, levels of evidence reported are in many cases low. More importantly, there is still no clear consensus on topics such as the optimal metrics that must be used to assess competence, the validity of VR simulation, the portability of tracking technologies into real surgeries (for advanced assessment) or the degree to which the skills measured and obtained in laboratory environments transfer to the OR. The purpose of this PhD is to design and validate a conceptual framework for the definition and validation of MIS assessment environments based on a three-pillared model defining three main stages: pedagogical (tasks and metrics to employ), technological (metric acquisition technologies) and analytical (interpretation of competence based on metrics). To this end, a practical implementation of the framework is presented, focused on (1) a video-based tracking system and (2) the determination of surgical competence based on the laparoscopic instruments’ motionrelated data. The pedagogical stage’s results led to the design and implementation of a set of basic tasks for MIS psychomotor skills’ assessment, as well as the definition of motion analysis parameters (MAPs) to measure performance on said tasks. Validation yielded good construct results for parameters such as time, path length, depth, average speed, average acceleration, economy of area and economy of volume. Additionally, face validation results showed positive acceptance on behalf of the experts, residents and novices. For the technological stage the EVA Tracking System is introduced. EVA provides a solution for tracking laparoscopic instruments from the analysis of the monoscopic video image. Accuracy tests for the system are presented, which yielded an average RMSE of 16.33pp for 2D tracking of the instrument on the image and of 13mm for 3D spatial tracking. A validation experiment was conducted using one of the tasks and the most relevant MAPs. Construct validation showed significant differences for time, path length, depth, average speed, average acceleration, economy of area and economy of volume; especially between novices and residents/experts. More importantly, concurrent validation with the TrEndo® Tracking System presented high correlation values (>0.7) for 8 of the 9 MAPs proposed. Finally, the analytical stage allowed comparing the performance of three different supervised classification strategies in the determination of surgical competence based on motion-related information. The three classifiers were based on linear (linear discriminant analysis, LDA), non-linear (support vector machines, SVM) and fuzzy (adaptive neuro fuzzy inference systems, ANFIS) approaches. Results for SVM show slightly better performance than the other two classifiers: on average, accuracy for LDA, SVM and ANFIS was of 71.7%, 78.2% and 71% respectively. However, when confronted, no statistical significance was found between any of the three. Overall, this PhD corroborates the investigated research hypotheses regarding the definition of MIS assessment systems, the use of endoscopic video analysis as the main source of information and the relevance of motion analysis in the determination of surgical competence. New research fields in the training and assessment of MIS surgeons can be proposed based on these foundations, in order to contribute to the definition of structured and objective learning programmes that guarantee the accreditation of well-prepared professionals and the promotion of patient safety in the OR.