999 resultados para Heart -- Contraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heart failure (HF) incidence in diabetes in both the presence and absence of CHD is rising. Prospective population-based studies can help describe the relationship between HbA(1c), a measure of glycaemia control, and HF risk. We studied the incidence of HF hospitalisation or death among 1,827 participants in the Atherosclerosis Risk in Communities (ARIC) study with diabetes and no evidence of HF at baseline. Cox proportional hazard models included age, sex, race, education, health insurance status, alcohol consumption, BMI and WHR, and major CHD risk factors (BP level and medications, LDL- and HDL-cholesterol levels, and smoking). In this population of persons with diabetes, crude HF incidence rates per 1,000 person-years were lower in the absence of CHD (incidence rate 15.5 for CHD-negative vs 56.4 for CHD-positive, p < 0.001). The adjusted HR of HF for each 1% higher HbA(1c) was 1.17 (95% CI 1.11-1.25) for the non-CHD group and 1.20 (95% CI 1.04-1.40) for the CHD group. When the analysis was limited to HF cases which occurred in the absence of prevalent or incident CHD (during follow-up) the adjusted HR remained 1.20 (95% CI 1.11-1.29). These data suggest HbA(1c) is an independent risk factor for incident HF in persons with diabetes with and without CHD. Long-term clinical trials of tight glycaemic control should quantify the impact of different treatment regimens on HF risk reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE-This study sought to investigate an association of HbA1c (A1C) with incident heart failure among individuals without diabetes and compare it to fasting glucose. RESEARCH DESIGN AND METHODS-We studied 11,057 participants of the Atherosclerosis Risk in Communities (ARIC) Study without heart failure or diabetes at baseline and estimated hazard ratios of incident heart failure by categories of A1C (<5.0, 5.0-5.4 [reference], 5 5-59, and 6.0-6.4%) and fasting glucose (<90, 90-99 [reference], 100-109, and 110-125 mg/dl) using Cox proportional hazards models. RESULTS-A total of 841 cases of incident heart failure hospitalization or deaths (International Classification of Disease, 9th/10th Revision, 428/150) occurred during a median follow-up of 14.1 years (incidence rate 5.7 per 1,000 person-years). After the adjustment for covariates including fasting glucose, the hazard ratio of incident heart failure was higher in individuals with A1C 6.0-6.4% (1.40 [95% CI, 1 09-1.79]) and 5.5-6.0% (1.16 [0.98-1 37]) as compared with the reference group. Similar results were observed when adjusting for insulin level or limiting to heart failure cases without preceding coronary events or developed diabetes during follow-up. In contrast, elevated fasting glucose was not associated with heart failure after adjustment for covariates and A1C. Similar findings were observed when the top quartile (A1C, 5.7-6.4%, and fasting glucose, 108-125 mg/dl) was compared with the lowest quartile (<5 2% and <95 mg/dl, respectively). CONCLUSIONS-Elevated A1C (>= 5.5-6 0%) was associated with incident heart failure in a middle-aged population without diabetes, suggesting that chronic hyperglycemia prior to the development of diabetes contributes to development of heart failure. Diabetes 59:2020-2026, 2010