290 resultados para HEEL PRICK


Relevância:

10.00% 10.00%

Publicador:

Resumo:

To test the comparative effectiveness of 2 nonpharmacologic pain-relieving interventions administered alone or in combination across time for repeated heel sticks in preterm infants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Petasin (Ze 339) was recently introduced on the market as a potent herbal antiallergic drug for treatment of respiratory allergies such as hay fever. Few clinical studies have been performed so far addressing the clinical effectiveness of Ze 339. OBJECTIVE: To evaluate the antiallergic properties of Ze 339 using skin prick tests with different stimuli, such as codeine, histamine, methacholine, and a relevant inhalant allergen. METHODS: A randomized, double-blind, placebo-controlled study was performed in which Ze 339 was compared to acrivastine, a short-acting antihistamine, in 8 patients with respiratory allergy and in 10 nonatopic, healthy volunteers. Antiallergic activity of Ze 339 was determined by analyzing inhibitory potency in skin prick tests with codeine, histamine, methacholine, and an inhalant allergen. Wheal-and-flare reactions were assessed 90 minutes after a double dose of Ze 339, acrivastine, or placebo. An interval of at least 3 days was left between the skin tests. RESULTS: Acrivastine was identified as the only substance that significantly inhibited skin test reactivity to all solutions analyzed in all study subjects. In contrast, no significant inhibition could be demonstrated for Ze 339 with any test solution. Moreover, the results of Ze 339 did not differ significantly from placebo. CONCLUSIONS: In this study we found no antiallergic, particularly antihistaminic, effect of Ze 339 in skin tests using a variety of stimuli often used to evaluate immediate skin test reactivity. The mechanism by which Ze 339 is effective in the treatment of seasonal allergic rhinitis still needs to be elucidated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: IL-18 is a pleiotrophic cytokine involved in both, T-helper type 1 (Th1) and Th2 differentiation. Recently genetic variants in the IL-18 gene have been associated with increased risk of atopy and asthma. OBJECTIVE: To examine the relationship of a genetic, haplotype-tagging promotor variant -137G/C in the IL-18 gene with atopic asthma in a large, well-characterized and population-based study of adults. METHODS: Prospective cohort study design was used to collect interview and biological measurement data at two examination time-points 11 years apart. Multivariate logistic regression analysis was used to assess the association of genotype with asthma and atopy. RESULTS: The G-allele of the IL-18 promotor variant (-137G/C) was associated with a markedly increased risk for the prevalence of physician-diagnosed asthma with concomitant skin reactivity to common allergens. Stratification of the asthma cases by skin reactivity to common allergens revealed an exclusive association of IL-18 -137 G-allele with an increased prevalence of atopic asthma (adjusted odds ratio (OR): 3.63; 95% confidence interval: (1.64-8.02) for GC or GG carriers vs. CC carriers), and no according association with asthma and concomitant negative skin reactivity (adjusted OR: 1.13; 0.66-1.94). The interaction between IL-18 -137G/C genotype and positive skin prick test was statistically significant (P=0.029). None of 74 incident asthma cases with atopy at baseline exhibited the CC genotype. CONCLUSION: Our results strongly suggest that this variant of the IL-18 gene is an important genetic determinant involved in the development of atopic asthma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The process of epidermal renewal persists throughout the entire life of an organism. It begins when a keratinocyte progenitor leaves the stem cell compartment, undergoes a limited number of mitotic divisions, exits the cell cycle, and commits to terminal differentiation. At the end of this phase, the postmitotic keratinocytes detach from the basement membrane to build up the overlaying stratified epithelium. Although highly coordinated, this sequence of events is endowed with a remarkable versatility, which enables the quiescent keratinocyte to reintegrate into the cell cycle and become migratory when necessary, for example after wounding. It is this versatility that represents the Achilles heel of epithelial cells allowing for the development of severe pathologies. Over the past decade, compelling evidence has been provided that epithelial cancer cells achieve uncontrolled proliferation following hijacking of a "survival program" with PI3K/Akt and a "proliferation program" with growth factor receptor signaling at its core. Recent insights into adhesion receptor signaling now propose that integrins, but also cadherins, can centrally control these programs. It is suggested that the two types of adhesion receptors act as sensors to transmit extracellular stimuli in an outside-in mode, to inversely modulate epidermal growth factor receptor signaling and ensure cell survival. Hence, cell-matrix and cell-cell adhesion receptors likely play a more powerful and wide-ranging role than initially anticipated. This Perspective article discusses the relevance of this emerging field for epidermal growth and differentiation, which can be of importance for severe pathologies such as tumorigenesis and invasive metastasis, as well as psoriasis and Pemphigus vulgaris.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To explore the variability in pain response in preterm infants across time who received sucrose during routine heel stick. METHOD: Single group, exploratory repeated measures design. SETTING: Two tertiary level neonatal intensive care units (NICU) in Switzerland. SUBJECTS: Nine preterm infants born between 28 2/7 and 31 4/7 weeks of gestation during their first 14 days of life. MEASUREMENTS: Pain was assessed by the Bernese Pain Scale for Neonates (BPSN), the Premature Infant Pain Profile (PIPP) and the Visual Analogue Scale (VAS). Salivary cortisol was analysed. RESULTS: 72-94% of the variability was within-subject variability, indicating inconsistency of pain responses across the 5 heel sticks. Interrater agreement was highest during heel sticks 1-3 and decreased during heel stick 4 and 5, indicating a possible alteration of pain patterns. No significant differences in the amount of cortisol could be detected before and after the heel sticks (p = 0.55), indicating no stress-induced peak after the painful intervention. However, a general gradual decrease of cortisol levels across time could be detected. CONCLUSION: A high variability in pain response among preterm neonates across time could be described. Consistency of cortisol levels before and after the heel sticks could indicate the effectiveness of sucrose across time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extended lateral L-shaped approach for the treatment of displaced intra-articular fractures of the calcaneum may be complicated by wound infection, haematoma, dehiscence and injury to the sural nerve. In an effort to reduce the risk of problems with wound healing a technique was developed that combined open reduction and fixation of the joint fragments and of the anterior process with percutaneous reduction and screw fixation of the tuberosity. A group of 24 patients with unilateral isolated closed Sanders type II and III fractures was treated using this technique and compared to a similar group of 26 patients managed by the extended approach and lateral plating. The operation was significantly shorter (p < 0.001) in the first group, but more minor secondary procedures and removal of heel screws were necessary. There were no wound complications in this group, whereas four minor complications occurred in the second group. The accuracy and maintenance of reduction, and ultimate function were equivalent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Airway disease in childhood comprises a heterogeneous group of disorders. Attempts to distinguish different phenotypes have generally considered few disease dimensions. The present study examines phenotypes of childhood wheeze and chronic cough, by fitting a statistical model to data representing multiple disease dimensions. From a population-based, longitudinal cohort study of 1,650 preschool children, 319 with parent-reported wheeze or chronic cough were included. Phenotypes were identified by latent class analysis using data on symptoms, skin-prick tests, lung function and airway responsiveness from two preschool surveys. These phenotypes were then compared with respect to outcome at school age. The model distinguished three phenotypes of wheeze and two phenotypes of chronic cough. Subsequent wheeze, chronic cough and inhaler use at school age differed clearly between the five phenotypes. The wheeze phenotypes shared features with previously described entities and partly reconciled discrepancies between existing sets of phenotype labels. This novel, multidimensional approach has the potential to identify clinically relevant phenotypes, not only in paediatric disorders but also in adult obstructive airway diseases, where phenotype definition is an equally important issue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soft tissue coverage of the medial ankle and foot remains a difficult, challenging, and often frustrating problem to patients as well as surgeons. To our knowledge, the abductor hallucis muscle flap is not frequently used and only a few well documented cases were found in literature. The purpose of this paper is to report and to present the long-term results of a series of four patients who underwent reconstruction of foot and ankle defects with the abductor hallucis muscle flap.In two cases, the abductor hallucis muscle flap was transposed in combination with a medialis pedis flap to cover a medial ankle defect, whereas in another case it was combined with a medial plantar flap. In this latter case, the muscle flap served to fill up a calcaneal dead space after osteomyelitis debridement, whereas the cutaneous flap was used to replace debrided skin at the heel. The abductor hallucis flap was used as a distally-based turnover flap to cover a large forefoot defect in a fourth case. Follow-up period ranged between 18 and 64 months (mean 43.3). In the early postoperative period, two flaps healed completely In two patients marginal flap necrosis occurred which was subsequently skin grafted. No donor-site complication occurred in any of the patients. In all cases, protective sensation of the skin was satisfactory as early as 6 months. In two cases mild hyperkeratosis at the skin graft border to the sole skin (non-weight bearing area of medial plantar and medialis pedis flap donor site) was present, but probably related to poor foot care. All patients were fully mobile as early as 3 months after treatment. In the long-term follow-up (43.3 months), all flaps provided with durable coverage. Functional gait deficit due to consumtion of the abductor hallucis muscle was not apparent.Our long-term results demonstrated that the abductor hallucis muscle flap is a versatile, and reliable flap suitable for the reconstruction of foot and ankle defects. Utilizing the abductor hallucis muscle as a pedicled flap (distally or proximally-based) with or without conjoined regional fasciocutaneous flaps offers a successful and durable alternative to microsurgical tree flaps for small to moderate defects over the calcaneus region, medial ankle, medial foot, and forefoot with exposed bone, tendon, or joint.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During locomotion, turning is a common and recurring event which is largely neglected in the current state-of-the-art ankle-foot prostheses, forcing amputees to use different steering mechanisms for turning, compared to non-amputees. A better understanding of the complexities surrounding lower limb prostheses will lead to increased health and well-being of amputees. The aim of this research is to develop a steerable ankle-foot prosthesis that mimics the human ankle mechanical properties. Experiments were developed to estimate the mechanical impedance of the ankle and the ankles angles during straight walk and step turn. Next, this information was used in the design of a prototype, powered steerable ankle-foot prosthesis with two controllable degrees of freedom. One of the possible approaches in design of the prosthetic robots is to use the human joints’ parameters, especially their impedance. A series of experiments were conducted to estimate the stochastic mechanical impedance of the human ankle when muscles were fully relaxed and co-contracting antagonistically. A rehabilitation robot for the ankle, Anklebot, was employed to provide torque perturbations to the ankle. The experiments were performed in two different configurations, one with relaxed muscles, and one with 10% of maximum voluntary contraction (MVC). Surface electromyography (sEMG) was used to monitor muscle activation levels and these sEMG signals were displayed to subjects who attempted to maintain them constant. Time histories of ankle torques and angles in the lateral/medial (LM) directions, inversion-eversion (IE), and dorsiflexionplantarflexion (DP) were recorded. Linear time-invariant transfer functions between the measured torques and angles were estimated providing an estimate of ankle mechanical impedance. High coherence was observed over a frequency range up to 30 Hz. The main effect of muscle activation was to increase the magnitude of ankle mechanical impedance in all degrees of freedom of the ankle. Another experiment compared the three-dimensional angles of the ankle during step turn and straight walking. These angles were measured to be used for developing the control strategy of the ankle-foot prosthesis. An infrared camera system was used to track the trajectories and angles of the foot and leg. The combined phases of heel strike and loading response, mid stance, and terminal stance and pre-swing were determined and used to measure the average angles at each combined phase. The Range of motion (ROM) in IE increased during turning while ML rotation decreased and DP changed the least. During the turning step, ankle displacement in DP started with similar angles to straight walk and progressively showed less plantarflexion. In IE, the ankle showed increased inversion leaning the body toward the inside of the turn. ML rotation initiated with an increased medial rotation during the step turn relative to the straight walk transitioning to increased lateral rotation at the toe off. A prototype ankle-foot prosthesis capable of controlling both DP and IE using a cable driven mechanism was developed and assessed as part of a feasibility study. The design is capable of reproducing the angles required for straight walk and step turn; generates 712N of lifting force in plantarflexion, and shows passive stiffness comparable to a nonload bearing ankle impedance. To evaluate the performance of the ankle-foot prosthesis, a circular treadmill was developed to mimic human gait during steering. Preliminary results show that the device can appropriately simulate human gait with loading and unloading the ankle joint during the gait in circular paths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Aeroallergens from house dust mite (HDM) may be an important trigger in a subgroup of patients with atopic dermatitis (AD). HDM and cockroach (CR) contain cross-reactive allergens, such as tropomyosin. OBJECTIVE: To investigate the diagnostic value of patch testing with an aeroallergen and the role of CR allergen and HDM allergen in persons with AD. METHODS: We performed skin prick tests (SPT) with a panel of common aeroallergens and total serum immunoglobulin (Ig)E and specific IgE tests for CR and HDM on 23 patients with AD and 9 nonatopic control participants. Atopy patch tests (APT) were performed with CR and HDM extracts on clinically uninvolved skin on the back, and evaluated after 48 and 72 hours. RESULTS: A positive APT reaction to CR was found in 10/23 (43%) patients with AD. No positive reactions were observed in the nonatopic control participants. Positive APT reactions for CR showed no significant correlation with SPT or specific IgE levels for this allergen. Twelve of the 23 (52%) patients with AD were also sensitized to HDM. There was no significant correlation between positive results for SPT, APT, and specific IgE to CR and HDM. CONCLUSION: We demonstrate that CR allergens can induce positive patch test reactions in patients with AD. The absence of a significant correlation to SPT and specific IgE antibodies suggests that T-cell- and IgE-sensitization may be mediated by different allergens. There was no significant relationship between CR and HDM sensitivity, thus indicating no major cross-reactivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone ultrasound measures (QUSs) can assess fracture risk in the elderly. We compared three QUSs and their association with nonvertebral fracture history in 7562 Swiss women 70-80 years of age. The association between nonvertebral fracture was higher for heel than phalangeal QUS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND In Chopart-level amputations the heel often deviates into equinus and varus when, due to the lack of healthy anterior soft tissue, rebalancing tendon transfers to the talar head are not possible. Consequently, anterior and lateral wound dehiscence and ulceration may occur requiring higher-level amputation to achieve wound closure, with considerable loss of function for the patients. METHODS Twenty-four consecutive patients (15 diabetes, 6 trauma, and 3 tumor) had Chopart's amputation and simultaneous or delayed additional ankle dorsiflexion arthrodesis to allow for tension-free wound closure or soft tissue reconstruction, or to treat secondary recurrent ulcerations. Percutaneous Achilles tendon lengthening and subtalar arthrodesis were added as needed. Wound healing problems, time to fusion and full weight-bearing in the prosthesis, complications in the prosthesis, and the ambulatory status were assessed. Satisfaction and function were evaluated by the AmpuPro score and the validated Prosthesis Evaluation Questionnaire scale. RESULTS Five patients had successful soft tissue healing and fusions but died of their underlying disease 2 to 46 months after the operation. Two diabetic patients required a transtibial amputation. The other 17 patients were followed for 27 months (range, 13-63). The average age of the 4 women and 13 men was 53.9 years (range, 16-87). Postoperative complications included minor wound healing problems in 8 patients, wound breakdown requiring revision in 4, phantom pain in 3, residual equinus in 1, and adjacent scar carcinoma in 1 patient. The time to full weight-bearing in the prosthesis ranged from 6 to 24 weeks (mean 10). The mean AmpuPro score was 107 points (of 120), and the mean Prosthesis Evaluation Questionnaire scale was 147 points (of 200). No complications occurred with the prosthesis. Twelve patients lost 1 to 2 mobility classes (mean 0.9). The arthrodeses all healed within 2.5 months (range, 1.5 to 5 months). CONCLUSION Adding an ankle arthrodesis to a Chopart's amputation either immediately or in a delayed fashion to treat anterior soft tissue complications was a successful salvage in most patients at this amputation level. It enabled the patients to preserve the advantages of a full-length limb with terminal weight-bearing. LEVEL OF EVIDENCE Level IV, retrospective case series.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bei Medikamentenallergien kommt es zu Immunreaktionen, die gegen das Medikament gerichtet sind und klinische Symptome verursachen. Man unterscheidet zwischen Hapten- und p-i-bedingten Reaktionen, wobei letztere nur für T-Zell-Reaktionen nachgewiesen wurden. Die häufigsten Immunmechanismen, welche Medikamentenallergien zugrunde liegen, sind Vermehrung von spezifischen IgE-produzierenden B- und/oder spezifischen T-Zellen. IgG-vermittelte Reaktionen, die z.B. eine hämolytische Anämie verursachen können, sind selten. Spezifische IgE können mittels CAP-Technologie nachgewiesen werden. Das Medikament muss an eine Trägersubstanz covalent gebunden werden, was den Nachteil mit sich bringt, dass die entsprechende Bindungsstelle im Medikament für IgE nicht erkennbar ist. Der Basophilenaktivierungstest (BAT) arbeitet meist mit freiem, ungebundenem Medikament. Wie die IgE-Vernetzung stattfindet, ist allerdings unklar. Beide Teste sind nicht genügend sensitiv um den In-vivo-Test (Prick oder i.d.) zu ersetzen. Bei T-Zell-Reaktionen wird in vitro meist die Proliferation der durch das Medikament stimulierten T-Zellen erfasst. Die Blutzellen (antikoaguliertes Blut) sollte innerhalb von 24 h im Labor zur Verarbeitung ankommen, wo die Zellseparation durchgeführt wird, um die Zellen mit dem Medikament zu stimulieren. Diese Stimulation kann durch Messung von Aktivierungsmarker (mittels Flow-Zytometrie), sezernierter Zytokine (ELISA) oder 3H-Thymidin Einbau in die sich teilende Zellen (Lymphozytentransformations- Test, LTT) erfasst werden. Am meisten Erfahrung liegt für den LTT vor. Die Sensitivität wird bei eindeutigen Fällen auf 50 – 70% geschätzt, hängt aber stark vom Krankheitsbild und Medikament ab. Schwere makulopapulöse Reaktionen und DRESS (Drug Rash with Eosinophilia and Systemic Symptoms), AGEP (acute generalized exanthematous pustulosis) sind meist positiv im LTT, aber schwere bullöse Reaktionen (SJS/TEN; Stevens-Johnson Syndrom/toxische epidermale Nekrolyse) werden besser mittels Zytotoxteste und Zytokinsekretion erfasst, da eine T-Zell-Proliferation weniger prominent ist. Trotz der limitierten Sensitivität sind diese Teste gut geeignet um Kreuzreaktionen zu erfassen, bzw. für mechanistische Studien. Da Provokationsteste bei verzögerten Medikamentenallergien nicht zur Verfügung stehen (es ist unklar, wie lange und wie hoch dosiert man das Medikament bei verzögerten Reaktionen geben muss), werden diese Teste in Zukunft eher mehr eingesetzt werden. Wichtig ist, dass sie selten falsch positiv sind, und ein positives Resultat als relevant angesehen werden kann. Für die Abklärung seltener IgG-vermittelter Reaktionen kann man einen modifizierten Coombs-Test versuchen.