990 resultados para GUIDED BONE REGENERATION
Resumo:
The aim of the present study was to determine the action of AsGA laser irradiation on bone repair in the tibia of osteopenic rats. The animals were randomly divided into eight experimental groups according to the presence of ovarian hormone (sham group) or the absence of the hormone (OVX group), as well as being irradiated or non-irradiated. Low-level 904-nm laser (50 mJ/cm(2)) accelerated the repair process of osteopenic fractures, especially in the initial phase of bone regeneration.Introduction The development of new techniques to speed the process of bone repair has provided significant advances in the treatment of fractures. Some attention recently focused on the effects of biostimulation on bone.Methods Forty-eight adult rats were randomly divided into eight experimental groups (six animals in each group) according to the presence of ovarian hormone (sham group) or absence of the hormone (ovariectomized (OVX) group) as well as being irradiated or non-irradiated. For the application of low-level laser therapy, the animals were anesthetized with one third of the dose sufficient to immobilize the animal and irradiated with AsGa laser (904 nm, 50 mJ/cm(2) for 2s, point form and in contact). The control animals received the same type of manipulation as the irradiated animals, but with the laser turned off. Half of the animals were killed 7 days following the confection of the bone defect, and the other half were killed 21 days after the surgery. After complete demineralization, the tibias were cut cross-sectionally in the central region of the bone defect and embedded in paraffin blocks. The blocks were then cut in semi-seriated slices and stained with hematoxylin and eosin.Results There was new bone formation in the animals in the OVX group with laser treatment killed after 7 days (p<0.001). The lowest percentage of bone formation was observed in the OVX without laser killed after 7 days (p>0.05). All animals killed after 21 days exhibited linear closure of the lesion.Conclusion Low-level 904-nm laser (50 mJ/cm(2)) accelerated the repair process of osteopenic fractures, especially in the initial phase of bone regeneration.
Resumo:
Background and objective: The purpose of this study was to analyze histologically the influence of autologous platelet-rich plasma on bone healing in surgically created critical-size defects in rat calvaria.Material adn Methods: Thirty-two rats were divided into two groups: the control group (group C) and the platelet-rich plasma group. An 8-mm-diameter critical-size defect was created in the calvarium of each animal. In group C the defect was filled by a blood clot only. In the platelet-rich plasma group, 0.35 mL of platelet-rich plasma was placed in the defect and covered by 0.35 mL of platelet-poor plasma. Both groups were divided into subgroups (n = 8) and killed at either 4 or 12 wk postoperatively. Histometric (using image-analysis software) and histologic analyses were performed. The amount of new bone formed was calculated as a percentage of the total area of the original defect. Percentage data were transformed into arccosine for statistical analysis (analysis of variance, Tukey, p < 0.05).Results: No defect completely regenerated with bone. The platelet-rich plasma group had a statistically greater amount of bone formation than group C at both 4 wk (17.68% vs. 7.20%, respectively) and 12 wk (24.69% vs. 11.65%, respectively) postoperatively.Conclusion: Within the limits of this study, it can be concluded that platelet-rich plasma placed in the defects and covered by platelet-poor plasma significantly enhanced bone healing in critical-size defects in rat calvaria.
Resumo:
Mineral trioxide aggregate (MTA) is a powder aggregate containing mineral oxides with a good biological action and may facilitate the regeneration of the periodontal ligament and formation of bone. Calcium hydroxide demonstrates antibacterial properties, enhances tissue dissolution, and induces bone formation. The objective of this study was to evaluate the MTA in the bone healing process and verify if the calcium hydroxide P.A. can improve and accelerate this process. It was used forty rnale Wistar rats, which were divided into two groups, considering or not the use of calcium hydroxide P.A. solution before treatment. Thus, each one of these groups was divided in four groups with five animals each, according to the treatment and the defect filled by: animal's coagulum, monoolein gel, MTA in aqueous solution, and MTA combined with monoolein gel. After 10 days, the animals were perfused and the right hemimandibles removed for histological analysis. Statistical analysis of the data showed significant difference between all analyzed groups when it was made comparisons using or not calcium hydroxide P.A. (p < 0.0001). There was found statistical difference between the groups that was inserted or not MTA, independently the calcium hydroxide application (p < 0.05). Results showed that the MTA used was able to induce bone regeneration and had its action optimized when combined to calcium hydroxide P.A. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
We have developed a biodegradable composite scaffold for bone tissue engineering applications with a pore size and interconnecting macroporosity similar to those of human trabecular bone. The scaffold is fabricated by a process of particle leaching and phase inversion from poly(lactide-co-glycolide) (PLGA) and two calcium phosphate (CaP) phases both of which are resorbable by osteoclasts; the first a particulate within the polymer structure and the second a thin ubiquitous coating. The 3-5 mu m thick osteoconductive surface CaP abrogates the putative foreign body giant cell response to the underlying polymer, while the internal CaP phase provides dimensional stability in an otherwise highly compliant structure. The scaffold may be used as a biomaterial alone, as a carrier for cells or a three-phase drug delivery device. Due to the highly interconnected macroporosity ranging from 81% to 91%, with macropores of 0.8 similar to 1.8 mm, and an ability to wick up blood, the scaffold acts as both a clot-retention device and an osteoconductive support for host bone growth. As a cell delivery vehicle, the scaffold can be first seeded with human mesenchymal cells which can then contribute to bone formation in orthotopic implantation sites, as we show in immune-compromised animal hosts. We have also employed this scaffold in both lithomorph and particulate forms in human patients to maintain alveolar bone height following tooth extraction, and augment alveolar bone height through standard sinus lift approaches. We provide a clinical case report of both of these applications; and we show that the scaffold served to regenerate sufficient bone tissue in the wound site to provide a sound foundation for dental implant placement. At the time of writing, such implants have been in occlusal function for periods of up to 3 years in sites regenerated through the use of the scaffold.
Resumo:
The effects of Tissucol and Tissucol/EACA on bone healing were evaluated histologically. Experimental defects were made in both tibias of 25 rats. Test materials were placed in defects in right tibias and left tibias served as control. Five animals in each group were killed at 1, 3, 7, 14 and 21 days after surgery. Results showed that: a) Tissucol did not interfere with connective and osseous tissue formation; b) Tissucol allowed new bone formation; c) Tissue residues in Tissucol groups in sections of 21-day specimens did not impair healing; d) Tissucol/EACA was usually completely resorbed and healing was complete 21 days after surgery in the Tissucol/EACA group.
Resumo:
In orofacial implantology there are many types of implants for the different systems. Among these is the implant surface type, e.g., a screw type, cylindrical and laminar. Furthermore, the implants are different in their dimensions, their metal composition, their surface condition, such as smooth, grit or layered surfaces and in their methods of application. Two different self-tapping implants, one smooth and the other grit-blasted, are screwed into the bone, and another one with a plasma of titanium coating, which is also in a screw form but with greater spaces between the screw threads are compared. The greatest amount of bone deposition in the bone/implant interface was encountered in the latter one, the smooth surfaced implant being in second place. All of these systems can alter the implant healing process and to demonstrate this, we injected bone markers in the rabbits over different periods of time so as to observe the different areas of bone deposition in the tibias where the implants had been inserted. The bone tracers used were Alizarin, Calcein and Xylenol-orange. The amount of deposition was calculated by using the method of surface morphometry.
Resumo:
The objective of this study was to investigate the effects of ultrasound treatment and physical exercise on the velocity of bone consolidation and resistance to deformation. We performed osteotomy in the upper third of the right tibia of rats. Physical training consisted of swimming 1 h per day with a load of 5% b.w. for 30 days. Therapy with medium-intensity ultrasound was applied daily on the damaged area. Wistar rats were divided into the following groups: osteotomized sedentary animals with no ultrasound treatment (1.OSnUS), osteotomized trained animals with no ultrasound treatment (2.OTnUS), osteotomized sedentary animals with ultrasound treatment (3.OSwUS). and osteotomized trained animals with ultrasound treatment (4.OTwUS). The animals were sacrificed for the following analyses: muscle glycogen, serum alkaline phosphatase at the 5th, 10th, 20th, and 30th days, test of maximum resistance to flexion, rupture flexion and mean tibial rigidity at the 30th day. Muscle glycogen was increased at the 20th day: alkaline phosphatase was elevated at the 5th and 20th days in groups 3.OSwUS and 4.OTwUS. and decreased at the 10th day. Groups1.OSnUS and 2.OTnUS did not show significant variations. In the mechanical resistance tests, we noted that ultrasound therapy and the association of physical activity used in the present study showed significant differences in bone resistance and bone rigidity after 30 days of treatment. These facts suggest that ultrasound or physical activity, or their combination may accelerate the process of bone tissue repair.
Resumo:
Purpose: The aim of this work was to evaluate the effectiveness of homogenous demineralized dentin matrix (HDDM) slices in surgical bone defects created in the mandibles of rabbits and occluded with a polytetrafluoroethylene (PTFE) membrane in the promotion of bone growth. Materials and Methods: Surgical bone defects were created in 36 adult rabbits and divided into 4 groups: bone defect (control), bone defect with PTFE membrane, bone defect with HDDM, and bone defect with both HDDM and a PTFE membrane (HDDM + PTFE). The rabbits were sacrificed after 30, 60, and 90 days, and the bone defects were examined histologically and by histomorphometric analysis (analysis of variance and the Tukey test). Results: The volume of newly formed bone matrix was significantly greater in the HDDM and HDDM + PTFE groups than in the control and PTFE groups. The discrete inflammatory reaction found in the HDDM and HDDM + PTFE groups did not prevent the osteopromotive activity of the dentin matrix. Discussion: HDDM slices were biocompatible and were resorbed during the bone remodeling process. They stimulated the newly formed bone until 30 days after implantation. Conclusion: Bone repair was accelerated in the bone defects treated with HDDM in comparison to the control group.
Resumo:
Purpose: The aim of the present study was to evaluate zygomatic bone thickness considering a possible relationship between this parameter and cephalic index (Cl) for better use of Cl in the implant placement technique. Materials and Methods: Cl was calculated for 60 dry Brazilian skulls. The zygo matic bones of the skulls were divided into 13 standardized sections for measurement. Bilateral measurements of zygomatic bone thickness were made on dry skulls. Results: Sections 5, 6, 8, and 9 were appropriate for implant anchorage in terms of location. The mean thicknesses of these sections were 6.05 mm for section 5, 3.15 mm for section 6, 6.13 mm for section 8, and 4.75 mm for section 9. In only 1 section, section 8, did mean thickness on 1 side of of the skull differ significantly from mean thickness on the other side (P <.001). Discussion: For the relationship between quadrant thick ness and Cl, sections 6 and 8 varied independently of Cl. Section 5 associated with brachycephaly, and section 9 associated with subbrachycephaly, presented variations in the corresponding thickness. Conclusion: Based on the results, implants should be placed in sections 5 and 8, since they presented the greatest thickness, except in brachycephalic subjects, where thickness was greatest in section 5, and in subbrachycephalic subjects, where thickness was greatest in section 9. Cl did not prove to be an appropriate parameter for evaluating zygomatic bone thickness for this sampling.
Resumo:
This study investigated, both histologically and histometrically, the efficacy of enamel matrix derived proteins (EMD) associated with bioactive glass (BG) and an absorbable membrane in the treatment of class III furcation defects in mongrel dogs. After surgical defect creation and chronification, the lesions were randomly divided into three groups according to the treatment employed: Test Group 1 - EMD + BG + membrane, Test Group 2 - EMD + membrane and Control Group - BG + membrane. After a 90-day healing period, the dogs were sacrificed. The descriptive analysis and the histometric data showed similar results for the experimental groups in all studied parameters (MANOVA, p > 0.05). The association of Emdogain® with bioglass and GTR, or with GTR only, showed similar results when compared with the ones obtained with bioglass associated with membrane in the treatment of class III furcation defects in dogs. The three modalities of treatment showed partial filling of the furcations, with bone and cementum regeneration limited to the apical portion of the defects.
Resumo:
Background: Recent clinical studies have described maxillary sinus floor augmentation by simply elevating the maxillary sinus membrane without the use of adjunctive grafting materials. Purpose: This experimental study aimed at comparing the histologic outcomes of sinus membrane elevation and simultaneous placement of implants with and without adjunctive autogenous bone grafts. The purpose was also to investigate the role played by the implant surface in osseointegration under such circumstances. Materials and Methods: Four tufted capuchin primates had all upper premolars and the first molar extracted bilaterally. Four months later, the animals underwent maxillary sinus membrane elevation surgery using a replaceable bone window technique. The schneiderian membrane was kept elevated by insertion of two implants (turned and oxidized, Brånemark System®, Nobel Biocare AB, Göteborg, Sweden) in both sinuses. The right sinus was left with no additional treatment, whereas the left sinus was filled with autogenous bone graft. Implant stability was assessed through resonance frequency analysis (Osstell™, Integration Diagnostics AB, Göteborg, Sweden) at installation and at sacrifice. The pattern of bone formation in the experimental sites and related to the different implant surfaces was investigated using fluorochromes. The animals were sacrificed 6 months after the maxillary sinus floor augmentation procedure for histology and histomorphometry (bone-implant contact, bone area in threads, and bone area in rectangle). Results: The results showed no differences between membrane-elevated and grafted sites regarding implant stability, bone-implant contacts, and bone area within and outside implant threads. The oxidized implants exhibited improved integration compared with turned ones as higher values of bone-implant contact and bone area within threads were observed. Conclusions: The amount of augmented bone tissue in the maxillary sinus after sinus membrane elevation with or without adjunctive autogenous bone grafts does not differ after 6 months of healing. New bone is frequently deposited in contact with the schneiderian membrane in coagulum-alone sites, indicating the osteoinductive potential of the membrane. Oxidized implants show a stronger bone tissue response than turned implants in sinus floor augmentation procedures. © 2006 Blackwell Publishing, Inc.
Resumo:
The aim of this study is to compare polyurethanes containing castor oil (soft segment) in granular form compared to cancellous bone autograft applied to a segmental bone defect. Norfolk adult female rabbits - approximately 13 months of age with a mean body weight of 4.5 kg - are used. In both radial diaphyses, 1 cm osteoperiosteal segmental defects are created. The defect in the left radius is filled with the castor-oil-based polyurethane, and the right one, filled with cancellous bone autograft, collected from the left proximal humerus. The rabbits are euthanazed at 15, 30, 60, and 120 days postsurgery (5 animals/ period), for histological analyses. By radiographic analyses, at these time points, the bone regeneration is more evident and accelerated in the bone defects treated with the cancellous bone autograft. At 120 days postsurgery, the segmental bone defects treated with the cancellous bone autograft are totally reconstituted and remodeled, while the bone defects treated with polyurethane polymer have bone formation of 79%. Histological study shows that the polyurethane acts as a space filler, minimizing the local production of fibrous tissue. No granule degradation, resorption or any inflammatory reaction is detected. Thus, it is possible to conclude that the castor-oil-plant-based polyurethane - in the granule presentation - is biocompatible and osteointegrated, but does not show the same bone regeneration capacity as the cancellous bone autograft. © 2007 SAGE Publications.
Resumo:
Objective: The purpose of this study was to analyze histologically the influence of bioactive glass (BG) with or without a calcium sulfate (CS) barrier on bone healing in surgically created critical-size defects (CSD) in rat calvaria. Material and methods: A CSD was made in each calvarium of 48 rats. They were divided into three groups: C (control): blood clot only; BG: defect filled with BG; and BG/CS: defect filled with BG covered by a CS barrier. Animals were euthanized at 4 or 12 weeks. Formation of new bone was evaluated histomorphometrically. Results: No defect completely regenerated with bone. BG particles were observed in Groups BG and BG/CS at both periods of analysis. The thickness throughout the healing area in Groups BG and BG/CS was similar to the original calvarium, while Group C presented a thin connective tissue in the center of the defect in both periods of analysis. At 4 weeks, Groups C and BG/CS presented significantly more bone formation than Group BG. No significant differences were found between Groups C and BG/CS. At 12 weeks, no significant differences in the amount of bone formation were observed among the three groups. When comparing 4 and 12 weeks, there was a significant increase in new bone formation within groups BG and BG/CS, but not C. Conclusion: BG particles, used with or without a CS barrier, maintained the volume and contour of the area grafted in CSD. However, they did not lead to a significant difference in bone formation when compared with control at 12 weeks post-operative. © 2007 Blackwell Munksgaard.
Resumo:
Purpose: The aim of this work was to evaluate the bone-repair process after implantation of homogenous demineralized dentin matrix (HDDM) slices in surgical defects created in the parietal bones of rabbits with alloxan-induced diabetes. Materials and Methods: Forty-eight rabbits were selected and divided into 4 groups of 12 rabbits: the control group, diabetic rabbits (D), diabetic rabbits with a PTFE barrier (D-PTFE), and diabetic rabbits with a PTFE barrier and with slices of homogenous demineralized dentin matrix (D-PTFE+HDDM). The diabetic animals received a single dose of alloxan monohydrate (90 mg/kg) intravenously on the marginal ear vein, and their blood glucose was verified daily. The rabbits were sacrificed after 15, 30, 60, and 90 days. The histologic findings show both better bone structure and significantly greater bone density, as determined by histomorphometric analysis, for the D-PTFE + HDDM group than for the other 3 groups (P < .01). It was also observed that the mean bone density increased gradually from 15 to 90 days (except in the D-PTFE group). Conclusion: It was concluded that the HDDM was biocompatible with the bone repair of diabetic rabbits and that HDDM slices stimulated bone tissue formation. Facilitation of bone repair with HDDM could be useful in diabetic patients.
Resumo:
Background: Previous studies have shown that membrane elevation results in predictable bone formation in the maxillary sinus provided that implants can be placed as tent poles. In situations with an extremely thin residual crest which impairs implant placement, it is possible that a space-making device can be used under the sinus membrane to promote bone formation prior to placement of implants. Purpose: The present study was conducted to test the hypothesis that the use of a space-making device for elevation of the sinus membrane will result in predictable bone formation at the maxillary sinus floor to allow placement of dental implants. Materials and Methods: Eight tufted capuchin primates underwent bilateral sinus membrane elevation surgery, and a bioresorbable space-making device, about 6 mm wide and 6 mm in height, was placed below the elevated membrane on the sinus floor. An oxidized implant (Nobel Biocare AB, Gothenburg, Sweden) was installed in the residual bone protruding into the created space at one side while the other side was left without an implant. Four animals were sacrificed after 6 months of healing. The remaining four animals received a second implant in the side with a space-making device only and followed for another 3 months before sacrifice. Implant stability was assessed through resonance frequency analysis (RFA) using the Osstell™ (Osstell AB, Gothenburg, Sweden) at installation, 6 months and 9 months after the first surgery. The bone-implant contact (BIC) and bone area inside the threads (BA) were histometrically evaluated in ground sections. Results: Histologically there were only minor or no signs of bone formation in the sites with a space-making device only. Sites with simultaneous implant placement showed bone formation along the implant surface. Sites with delayed implant placement showed minor or no bone formation and/or formation of a dense fibrous tissue along the apical part of the implant surface. In the latter group the apical part of the implant was not covered with the membrane but protruded into the sinus cavity. Conclusions: The use of a space-making device, with the design used in the present study, does not result in bone formation at the sinus floor. However, membrane elevation and simultaneous placement of the device and an implant does result in bone formation at the implant surface while sites with implants placed 6 months after membrane elevation show only small amounts of bone formation. It is suggested that lack of stabilization of the device and/or a too extensive elevation of the membrane may explain the results. © 2009, Wiley Periodicals, Inc.