918 resultados para Fine needle aspiration biopsy (FNAB)
Resumo:
A new device was developed to hold linear transducers for transvaginal follicle aspiration. Efficacy of follicle aspiration was compared using a linear 6 MHz and a convex 5 MHz transducer. Fifty-five cows were submitted to follicle aspiration at random days of the estrous cycle. Aspirations were conducted with linear (n = 28) and convex (n = 38) transducers with 18 G needles at a negative pressure corresponding to 13 ml H2O/min. A greater number of follicles were aspirated using convex than to linear probe (12.4 versus 7.8, respectively, P < 0.05). Mean number of oocytes and recovery rates were similar for convex (5.4 and 48.6%) and linear (4.6 and 59.3%) transducers. Limited space between the linear transducer and needle guide restricted access to some portions of the ovary, reducing the number of follicles aspirated using a linear transducer. The newly developed adaptor allowed greater stability, holding the ovaries firmly against the linear transducer. This diminished mobility permitted a similar number of oocytes to be recovered with both transducers. In conclusion, this new adaptor provided a low cost alternative for routine follicle aspiration and oocyte recovery in cattle. (C) 2002 Elsevier B.V. All rights reserved.
Resumo:
O presente estudo objetivou analisar a qualidade do diagnóstico de biopsias colhidas com agulhas tipo aspirativa e cortante, comparando-as ao exame histológico post-mortem do fígado de cães portadores de afecções hepáticas. Foram utilizados 60 cães, sem distinção de sexo, raça ou idade. As biopsias foram procedidas com agulhas tipo MenghiniÒ (de natureza aspirativa) e agulhas tipo Tru-CutÒ (de natureza cortante). As biopsias foram colhidas utilizando-se a técnica percutânea transabdominal. O diagnóstico referente à agulha tipo Tru-CutÒ não diferiu do diagnóstico referente à agulha tipo MenghiniÒ. O referente à agulha tipo Tru-CutÒ foi o que apresentou maior índice de concordância, 88,3% de acertos. A agulha tipo Tru-CutÒ apresentou excelentes resultados independente da natureza das lesões, enquanto que a agulha tipo MenghiniÒ falhou nos casos de fibrose.
Resumo:
The duct of the swine sweat gland crosses the dermis and epidermis in sequence. The cells of the dermic segment seem to be related with cellular secretion and absorption. In the epidermic segment of the duct the whole morphology of the cells resembles the cellular morphology of the epidermic cells.
Resumo:
Sequelae due to testicular biopsy such as hemorrhage, adhesion and fibrosis may be limiting factors to the use of this surgical procedure. Fibrin glue (FG) derived from snake venom was used to minimize these sequelae, as well as to evaluate its healing property in tunica vaginalis and scrotal skin of rams. Applicability of fibrin glue derived from snake venom was tested in different tissues of other animals such as in sciatic nerve and colon of rats and skin of rabbits. In the present study, 30 healthy adult rams were used. They were divided into 3 groups of 10 animals each as follows: G1: fibrin glue group (application of fibrin glue on puncture sites and skin incisions after bilateral testicular biopsy with a Tru-Cut needle); G2: swab/nylon group (hemostasis by compression with a swab on puncture sites and skin suturing with nylon after biopsy) and G3: control group (the animals were not subjected either to biopsy or to surgery). On the 20th day after biopsy, the presence of adhesion strands between the sites of skin incision and testicle was evaluated by palpation Adhesion strands were found in three testicles (15%) in G1 and in two testicles (10%) in G2. One hundred days after biopsy, orchiectomy was carried out and the material collected was assessed for subcutaneous (SC) and/or tunica vaginalis adhesions. G3 did not present any abnormality. Groups G1 and G2 presented four testicles each (20%) with adhesion between the tunics at biopsy site. On the other hand, subcutaneous adhesions were found once (5%) in G1 and three times (15%) in G2. Fibrin glue showed to be of easy application, required short postoperative monitoring, presented fast and good-quality healing property and tended to reduce formation of subcutaneous adhesion.
Resumo:
Background: We evaluated the presence of ductal carcinoma in situ (DCIS) in core needle biopsies (CNB) from invasive ductal lesions. Methods: Retrospective study, which analyzed 90 cases of invasive ductal carcinoma lesions. The percentage of DCIS was quantified in each specimens obtained from CNB, which were compared to the surgical specimens. CNB and surgical specimens were evaluated by the same pathologist, and the percentage of DCIS in CNB was evaluated (percentage) and divided into categories. We considered the following parameters regarding the amount of DCIS: 1 = 0; 2 = 1 for 5%; 3 = 6 for 24%; 4 = 25 for 50%; 5 = 51 for 75% and 6 = 76 for 99%. The number of fragments and the histological pattern of DCIS was found. Results: We found the following results regarding the distribution of the percentage of DCIS in the CNB: 1 = 63.3%; 2 = 12.2%; 3 = 12.2%; 4 = 5.6%; 5 = 1.1% and 6 = 5.6%. The logistic regression analysis showed that CNB percentages above 45% reflected the presence of DCIS in the surgical specimen in 100% of the cases (p<0.001), with a specificity of 100%, accuracy of 83.3% and false positive rate of 0% (p <0.001). Conclusion: There is direct relationship between extensive intraductal component in the surgical specimen when the core biopsy shows 45% or more of the DCI or microinvasive in the material examined. © 2012 Barbalaco Neto et al.
Resumo:
To assess the pain intensity of patients administered midazolam and fentanyl citrate before undergoing transrectal ultrasound-guided prostate biopsy. This was a study in patients with different indications for prostate biopsy in whom 5 mg of midazolam and 50 µg of fentanyl citrate was administered intravenously 3 minutes before the procedure. After biopsy, pain was assessed by use of a visual analogue scale (VAS) in three stages: VAS 1, during probe introduction; VAS 2, during needle penetration into prostate tissue; and VAS 3, in the weeks following the exam. Pain intensity at these different times was tested with stratification by age, race, education, prostate volume, rebiopsy, and anxiety before biopsy. Pain was ranked according to the following scores: 0 (no pain), 1-3 (mild pain), 4-7 (moderate pain), and 8-10 (severe pain). Statistical analysis was performed by using Kruskal-Wallis and Wilcoxon two-tailed tests with a significance of 5%. Pain intensity was not influenced by any risk factors. The mean VAS 1 score was 1.95±1.98, the mean VAS 2 score was 2.73±2.55, and the mean VAS 3 score was 0.3±0.9, showing greater pain at the time of needle penetration than in other situations (VAS 2>VAS 1>VAS 3, p=0.0013, p=0.0001, respectively). Seventy-five percent of patients reported a VAS pain scale of less than 3.1 or mild pain. Intravenous sedation and analgesia with midazolam and fentanyl citrate is a good method for reducing pain caused by prostate biopsy, even during probe insertion.
Resumo:
We report a case of a 78-year-old female with a proximal femur fracture caused by an accidental fall who died suddenly 1h after orthopaedic prosthesis insertion. Post-mortem computed tomography (CT) scan and histological examination of samples obtained with post-mortem percutaneous needle biopsies of both lungs were performed. Analysis of the medical history and the clinical scenario immediately before death, imaging data, and biopsy histology established the cause of death without proceeding to traditional autopsy. It was determined to be acute right ventricular failure caused by massive pulmonary fat embolism. Although further research in post-mortem imaging and post-mortem tissue sampling by needle biopsies is necessary, we conclude that the use of CT techniques and percutaneous biopsy, as additional tools, can offer a viable alternative to traditional autopsy in selected cases and may increase the number of minimally invasive forensic examinations performed in the future.
Resumo:
To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT).
Resumo:
INTRODUCTION: Recent advances in medical imaging have brought post-mortem minimally invasive computed tomography (CT) guided percutaneous biopsy to public attention. AIMS: The goal of the following study was to facilitate and automate post-mortem biopsy, to suppress radiation exposure to the investigator, as may occur when tissue sampling under computer tomographic guidance, and to minimize the number of needle insertion attempts for each target for a single puncture. METHODS AND MATERIALS: Clinically approved and post-mortem tested ACN-III biopsy core needles (14 gauge x 160 mm) with an automatic pistol device (Bard Magnum, Medical Device Technologies, Denmark) were used for probe sampling. The needles were navigated in gelatine/peas phantom, ex vivo porcine model and subsequently in two human bodies using a navigation system (MEM centre/ISTB Medical Application Framework, Marvin, Bern, Switzerland) with guidance frame and a CT (Emotion 6, Siemens, Germany). RESULTS: Biopsy of all peas could be performed within a single attempt. The average distance between the inserted needle tip and the pea centre was 1.4mm (n=10; SD 0.065 mm; range 0-2.3 mm). The targets in the porcine liver were also accurately punctured. The average of the distance between the needle tip and the target was 0.5 mm (range 0-1 mm). Biopsies of brain, heart, lung, liver, pancreas, spleen, and kidney were performed on human corpses. For each target the biopsy needle was only inserted once. The examination of one body with sampling of tissue probes at the above-mentioned locations took approximately 45 min. CONCLUSIONS: Post-mortem navigated biopsy can reliably provide tissue samples from different body locations. Since the continuous update of positional data of the body and the biopsy needle is performed using optical tracking, no control CT images verifying the positional data are necessary and no radiation exposure to the investigator need be taken into account. Furthermore, the number of needle insertions for each target can be minimized to a single one with the ex vivo proven adequate accuracy and, in contrast to conventional CT guided biopsy, the insertion angle may be oblique. Navigation for minimally invasive tissue sampling is a useful addition to post-mortem CT guided biopsy.
Resumo:
OBJECTIVE This study presents the first in vivo real-time optical tissue characterization during image-guided percutaneous intervention using near-infrared diffuse optical spectroscopy sensing at the tip of a needle. The goal of this study was to indicate transition boundaries from healthy tissue to tumors, namely, hepatic carcinoma, based on the real-time feedback derived from the optical measurements. MATERIALS AND METHODS Five woodchucks with hepatic carcinoma were used for this study. The woodchucks were imaged with contrast-enhanced cone beam computed tomography with a flat panel detector C-arm system to visualize the carcinoma in the liver. In each animal, 3 insertions were performed, starting from the skin surface toward the hepatic carcinoma under image guidance. In 2 woodchucks, each end point of the insertion was confirmed with pathologic examination of a biopsy sample. While advancing the needle in the animals under image guidance such as fluoroscopy overlaid with cone beam computed tomography slice and ultrasound, optical spectra were acquired at the distal end of the needles. Optical tissue characterization was determined by translating the acquired optical spectra into clinical parameters such as blood, water, lipid, and bile fractions; tissue oxygenation levels; and scattering amplitude related to tissue density. The Kruskal-Wallis test was used to study the difference in the derived clinical parameters from the measurements performed within the healthy tissue and the hepatic carcinoma. Kurtoses were calculated to assess the dispersion of these parameters within the healthy and carcinoma tissues. RESULTS Blood and lipid volume fractions as well as tissue oxygenation and reduced scattering amplitude showed to be significantly different between the healthy part of the liver and the hepatic carcinoma (P < 0.05) being higher in normal liver tissue. A decrease in blood and lipid volume fractions and tissue oxygenation as well as an increase in scattering amplitude were observed when the tip of the needle crossed the margin from the healthy liver tissue to the carcinoma. The kurtosis for each derived clinical parameter was high in the hepatic tumor as compared with that in the healthy liver indicating intracarcinoma variability. CONCLUSIONS Tissue blood content, oxygenation level, lipid content, and tissue density all showed significant differences when the needle tip was guided from the healthy tissue to the carcinoma and can therefore be used to identify tissue boundaries during percutaneous image-guided interventions.
Resumo:
La realtà aumentata (AR) è una nuova tecnologia adottata in chirurgia prostatica con l'obiettivo di migliorare la conservazione dei fasci neurovascolari (NVB) ed evitare i margini chirurgici positivi (PSM). Abbiamo arruolato prospetticamente pazienti con diagnosi di cancro alla prostata (PCa) sul base di biopsia di fusione mirata con mpMRI positiva. Prima dell'intervento, i pazienti arruolati sono stati indirizzati a sottoporsi a ricostruzione del modello virtuale 3D basato su mpMRI preoperatoria immagini. Infine, il chirurgo ha eseguito la RARP con l'ausilio del modello 3D proiettato in AR all'interno della console robotica (RARP guidata AR-3D). I pazienti sottoposti a AR RARP sono stati confrontati con quelli sottoposti a "RARP standard" nello stesso periodo. Nel complesso, i tassi di PSM erano comparabili tra i due gruppi; I PSM a livello della lesione indice erano significativamente più bassi nei pazienti riferiti al gruppo AR-3D (5%) rispetto a quelli nel gruppo di controllo (20%; p = 0,01). La nuova tecnica di guida AR-3D per l'analisi IFS può consentono di ridurre i PSM a livello della lesione dell'indice
Resumo:
To compare time and risk to biochemical recurrence (BR) after radical prostatectomy of two chronologically different groups of patients using the standard and the modified Gleason system (MGS). Cohort 1 comprised biopsies of 197 patients graded according to the standard Gleason system (SGS) in the period 1997/2004, and cohort 2, 176 biopsies graded according to the modified system in the period 2005/2011. Time to BR was analyzed with the Kaplan-Meier product-limit analysis and prediction of shorter time to recurrence using univariate and multivariate Cox proportional hazards model. Patients in cohort 2 reflected time-related changes: striking increase in clinical stage T1c, systematic use of extended biopsies, and lower percentage of total length of cancer in millimeter in all cores. The MGS used in cohort 2 showed fewer biopsies with Gleason score ≤ 6 and more biopsies of the intermediate Gleason score 7. Time to BR using the Kaplan-Meier curves showed statistical significance using the MGS in cohort 2, but not the SGS in cohort 1. Only the MGS predicted shorter time to BR on univariate analysis and on multivariate analysis was an independent predictor. The results favor that the 2005 International Society of Urological Pathology modified system is a refinement of the Gleason grading and valuable for contemporary clinical practice.
Resumo:
Background. Benign prostatic hyperplasia (BPH) pharmacological treatment may promote a decrease in prostate vascularization and bladder neck relaxation with theoretical improvement in prostate biopsy morbidity, though never explored in the literature. Methods. Among 242 consecutive unselected patients who underwent prostate biopsy, after excluding those with history of prostate biopsy/surgery or using medications not for BPH, we studied 190 patients. On the 15th day after procedure patients were questioned about symptoms lasting over a week and classified according to pharmacological BPH treatment. Results. Thirty-three patients (17%) were using alpha-blocker exclusively, five (3%) 5-alpha-reductase inhibitor exclusively, twelve (6%) patients used both medications, and 140 (74%) patients used none. There was no difference in regard to age among groups (P = 0.5). Postbiopsy adverse effects occurred as follows: hematuria 96 (50%), hematospermia 53 (28%), hematochezia 22 (12%), urethrorrhagia 19 (10%), fever 5 (3%), and pain 20 (10%). There was a significant negative correlation between postbiopsy hematuria and BPH pharmacological treatment with stronger correlation for combined use of 5-alpha-reductase inhibitor and alpha-blocker over 6 months (P = 0.0027). Conclusion. BPH pharmacological treatment, mainly combined for at least 6 months seems to protect against prostate biopsy adverse effects. Future studies are necessary to confirm our novel results.
Resumo:
The diagnosis of intraductal carcinoma (IDC) of the prostate remains subjective because 3 sets of diagnostic criteria are in use. An internet survey was compiled from 38 photomicrographs showing duct proliferations: 14 signed out as high-grade prostatic intraepithelial neoplasia (HGPIN), 17 IDC, and 7 invasive cribriform/ductal carcinoma. Each image was assessed for the presence of 9 histologic criteria ascribed to IDC. Thirty-nine respondents were asked to rate images as (1) benign/reactive, (2) HGPIN, (3) borderline between HGPIN and IDC, (4) IDC, or (5) invasive cribriform/ductal carcinoma. Intraclass correlation coefficient was 0.68. There was 70% overall agreement with HGPIN, 43% with IDC, and 73% with invasive carcinoma (P < .001, χ(2)). Respondents considered 19 (50%) of 38 cases as IDC candidates, of which 5 (26%) had a two-thirds consensus for IDC; two-thirds consensus for either borderline or IDC was reached in 9 (47%). Two-thirds consensus other than IDC was reached in the remaining 19 of 38 cases, with 15 supporting HGPIN and 4 supporting invasive carcinoma. Findings that differed across diagnostic categories were lumen-spanning neoplastic cells (P < .001), 2× benign duct diameters (P < .001), duct space contours (round, irregular, and branched) (P < .001), papillary growth (P = .048), dense cribriform or solid growth (both P = .023), and comedonecrosis (P = .015). When the 19 of 38 images that attained consensus for HGPIN or invasive carcinoma were removed from consideration, lack of IDC consensus was most often attributable to only loose cribriform growth (5/19), central nuclear maturation (5/19), or comedonecrosis (3/19). Of the 9 histologic criteria, only 1 retained significant correlation with a consensus diagnosis of IDC: the presence of solid areas (P = .038). One case that attained IDC consensus had less than 2× duct enlargement yet still had severe nuclear atypia and nucleomegaly. Six fold nuclear enlargement was not significant (P = .083), although no image had both 6× nuclei and papillary or loose cribriform growth: a combination postulated as sufficient criteria for IDC. Finally, 20.5% of respondents agreed that an isolated diagnosis of IDC on needle biopsy warrants definitive therapy, 20.5% disagreed, and 59.0% considered the decision to depend upon clinicopathologic variables. Although IDC diagnosis remains challenging, we propose these criteria: a lumen-spanning proliferation of neoplastic cells in preexisting ducts with a dense cribriform or partial solid growth pattern. Solid growth, in any part of the duct space, emerges as the most reproducible finding to rule in a diagnosis of IDC. Comedonecrosis is a rarer finding, but in most cases, it should rule in IDC. Duct space enlargement to greater than 2× the diameter of the largest, adjacent benign spaces is usually present in IDC, although there may be rare exceptions.
Resumo:
The objectives of the study were to evaluate the performance of sentinel lymph node biopsy (SLNB) in detecting occult metastases in papillary thyroid carcinoma (PTC) and to correlate their presence to tumor and patient characteristics. Twenty-three clinically node-negative PTC patients (21 females, mean age 48.4 years) were prospectively enrolled. Patients were submitted to sentinel lymph node (SLN) lymphoscintigraphy prior to total thyroidectomy. Ultrasound-guided peritumoral injections of (99m)Tc-phytate (7.4 MBq) were performed. Cervical single-photon emission computed tomography and computed tomography (SPECT/CT) images were acquired 15 min after radiotracer injection and 2 h prior to surgery. Intra-operatively, SLNs were located with a gamma probe and removed along with non-SLNs located in the same neck compartment. Papillary thyroid carcinoma, SLNs and non-SLNs were submitted to histopathology analysis. Sentinel lymph nodes were located in levels: II in 34.7 % of patients; III in 26 %; IV in 30.4 %; V in 4.3 %; VI in 82.6 % and VII in 4.3 %. Metastases in the SLN were noted in seven patients (30.4 %), in non-SLN in three patients (13.1 %), and in the lateral compartments in 20 % of patients. There were significant associations between lymph node (LN) metastases and the presence of angio-lymphatic invasion (p = 0.04), extra-thyroid extension (p = 0.03) and tumor size (p = 0.003). No correlations were noted among LN metastases and patient age, gender, stimulated thyroglobulin levels, positive surgical margins, aggressive histology and multifocal lesions. Sentinel lymph node biopsy can detect occult metastases in PTC. The risk of a metastatic SLN was associated with extra-thyroid extension, larger tumors and angio-lymphatic invasion. This may help guide future neck dissection, patient surveillance and radioiodine therapy doses.