945 resultados para Filters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel filter based on e-plane metal-dielectric insert in rectangular waveguide is proposed. Properties of the structure containing metallic septa, C- and I-shaped resonators placed in waveguide are investigated. Pseudo-elliptic cross-coupled filter with direct source-load coupling is designed, simulated and fabricated. Experimental results are presented to prove feasibility of the filter. Significant size reduction is achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an ultra compact waveguide bandpass filter that exhibits a pseudo-elliptic response. The transmission zero created in the upper stopband to form a rapid roll off is produced through a bypass coupling with higher order modes. A 3rd order filter is designed at the centre frequency of 9.4 GHz with a 5.3% fractional bandwidth. The proposed structure's size is 38% smaller than one of a 3rd order E-plane extracted pole filter with comparable response. Additionally, this configuration allows larger span of different bandwidths. The filter has been fabricated and tested using E-plane waveguide technology, which has benefits of being inexpensive and having mass producible capabilities. Measurements of such a fabricated filter validate the simulated results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter presents an ultra compact extracted pole E-plane filter. The proposed structure can achieve up to 65% size reduction in comparison with a standard extracted pole filter designed at 9.5 GHz centre frequency with a 3% fractional bandwidth. The filter has been fabricated and tested using E-plane waveguide technology. Measurements on a fabricated filter confirm the accuracy of the design method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an optically reconfigurable E-plane waveguide resonator and filter. N-type silicon dice doped with phosphorus is used as the switching element and is connected to the edge of a metallic fin. Illumination of the silicon dice allows realization of a different length of the fin, thus creating a shift in resonant frequency of the structure. Frequency tuning range up to about 5.2% is achieved for the resonator as well as the filter. Measurements on a fabricated optically reconfigurable resonator confirm the accuracy of the design procedure. Measured responses show good agreement with simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel compact tunable bandstop filter using Defected Microstrip Structure (DMS) is presented in this paper. The structure utilizes a modified T shaped DMS which helps in miniaturization of the filter. To verify the concept, one such filter was simulated, designed, fabricated and tested. Measurements on a fabricated tunable filter confirm the accuracy of the design procedure. The tuning range of 20% is achieved, ranging from 2.26 GHz to 2.747 GHz. Tuning is achieved by using NXP BB179 varactor diode. A nonlinear distortion evaluation in a tunable filter was experimentally verified. Experimental verification shows the filter is highly linear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a low complexity high efficiency decimation filter which can be employed in EletroCardioGram (ECG) acquisition systems. The decimation filter with a decimation ratio of 128 works along with a third order sigma delta modulator. It is designed in four stages to reduce cost and power consumption. The work reported here provides an efficient approach for the decimation process for high resolution biomedical data conversion applications by employing low complexity two-path all-pass based decimation filters. The performance of the proposed decimation chain was validated by using the MIT-BIH arrhythmia database and comparative simulations were conducted with the state of the art.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Constrained nonlinear optimization problems are usually solved using penalty or barrier methods combined with unconstrained optimization methods. Another alternative used to solve constrained nonlinear optimization problems is the lters method. Filters method, introduced by Fletcher and Ley er in 2002, have been widely used in several areas of constrained nonlinear optimization. These methods treat optimization problem as bi-objective attempts to minimize the objective function and a continuous function that aggregates the constraint violation functions. Audet and Dennis have presented the rst lters method for derivative-free nonlinear programming, based on pattern search methods. Motivated by this work we have de- veloped a new direct search method, based on simplex methods, for general constrained optimization, that combines the features of the simplex method and lters method. This work presents a new variant of these methods which combines the lters method with other direct search methods and are proposed some alternatives to aggregate the constraint violation functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potential risks of a secondary formation of polychlorinated dibenzodioxins/furans (PCDD/Fs) were assessed for two cordierite-based, wall-through diesel particulate filters (DPFs) for which soot combustion was either catalyzed with an iron- or a copper-based fuel additive. A heavy duty diesel engine was used as test platform, applying the eight-stage ISO 8178/4 C1 cycle. DPF applications neither affected the engine performance, nor did they increase NO, NO2, CO, and CO2 emissions. The latter is a metric for fuel consumption. THC emissions decreased by about 40% when deploying DPFs. PCDD/F emissions, with a focus on tetra- to octachlorinated congeners, were compared under standard and worst case conditions (enhanced chlorine uptake). The iron-catalyzed DPF neither increased PCDD/F emissions, nor did it change the congener pattern, even when traces of chlorine became available. In case of copper, PCDD/F emissions increased by up to 3 orders of magnitude from 22 to 200 to 12 700 pg I-TEQ/L with fuels of < 2, 14, and 110 microg/g chlorine, respectively. Mainly lower chlorinated DD/Fs were formed. Based on these substantial effects on PCDD/F emissions, the copper-catalyzed DPF system was not approved for workplace applications, whereas the iron system fulfilled all the specifications of the Swiss procedures for DPF approval (VERT).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The advent of retrievable caval filters was a game changer in the sense, that the previously irreversible act of implanting a medical device into the main venous blood stream of the body requiring careful evaluation of the pros and cons prior to execution suddenly became a "reversible" procedure where potential hazards in the late future of the patient lost most of their weight at the time of decision making. This review was designed to assess the rate of success with late retrieval of so called retrievable caval filters in order to get some indication about reasonable implant duration with respect to relatively "easy" implant removal with conventional means, i.e., catheters, hooks and lassos. A PubMed search (www.pubmed.gov) was performed with the search term "cava filter retrieval after 30 days clinical", and 20 reports between 1994 and 2013 dealing with late retrieval of caval filters were identified, covering approximately 7,000 devices with 600 removed filters. The maximal duration of implant reported is 2,599 days and the maximal implant duration of removed filters is also 2,599 days. The maximal duration reported with standard retrieval techniques, i.e., catheter, hook and/or lasso, is 475 days, whereas for the retrievals after this period more sophisticated techniques including lasers, etc. were required. The maximal implant duration for series with 100% retrieval accounts for 84 days, which is equivalent to 12 weeks or almost 3 months. We conclude that retrievable caval filters often become permanent despite the initial decision of temporary use. However, such "forgotten" retrievable devices can still be removed with a great chance of success up to three months after implantation. Conventional percutaneous removal techniques may be sufficient up to sixteen months after implantation whereas more sophisticated catheter techniques have been shown to be successful up to 83 months or more than seven years of implant duration. Tilting, migrating, or misplaced devices should be removed early on, and replaced if indicated with a device which is both, efficient and retrievable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Doctor en Ingeniería Eléctrica) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a seminal contribution, Hansson (1976) demonstrates that the collection of decisive coalitions associated with an Arrovian social welfare function forms an ultrafilter. He goes on to show that if transitivity is weakened to quasi-transitivity as the coherence property imposed on a social relation, the set of decisive coalitions is a filter. We examine the notion of decisiveness with acyclical or Suzumura consistent social preferences and without assuming that the social relation is complete. This leads to a new set-theoretic concept applied to product spaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives In April 2010, the Université de Montréal’s Health Sciences Library has implemented shared filters in its institutional PubMed account. Most of these filters are designed to highlight resources for evidence-based practice, such as Clinical Queries, Systematic Reviews and Evidence-based Synopsis. We now want to measure how those filters are perceived and used by our users. Methods For one month, data was gathered through an online questionnaire proposed to users of Université de Montréal’s PubMed account. A print version was also distributed to participants in information literacy workshops given by the health sciences librarians. Respondents were restricted to users affiliated to Université de Montréal’s faculties of Medicine, Dentistry, Veterinary Sciences, Nursing and Pharmacy. Basic user information such as year/program of study or department affiliation was also collected. The questionnaire allowed users to identify the filters they use, assess the relevance of filters, and also suggest new ones. Results Survey results showed that the shared filters of Université de Montreal’s PubMed account were found useful by the majority of respondents. Filters allowing rapid access to secondary resources ranked among the most relevant (Reviews, Systematic Reviews, Cochrane Database of Systematic Reviews, Practice Guidelines and Clinical Evidence). For Clinical Study Queries, Randomized Controlled Trial (Therapy/Narrow) was considered the most useful. Some new shared filters have been suggested by respondents. Finally, 18% of the respondents indicated that they did not quite understand the relevance of filters. Conclusion Based on the survey results, shared filters considered most useful will be kept, some will be enhanced and others removed so that suggested ones could be added. The fact that some respondents did not understand well the relevance of filters could potentially be addressed through our PubMed workshops, online library guides or by renaming some filters in a more meaningful way.