1000 resultados para Espectroscopia de prótons


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho foi realizado o estudo do comportamento fotoquímico e fotofísico de complexos mononucleares de rênio do tipo fac-[Re(CO)3(N N)(L)]+(N N = 1,10-fenantrolina, phen, dipirido[3,2-a:2,3-c]fenazina, dppz, L= trans-1,2bis(4-piridil)etileno, trans-bpe, trans-4-estirilpiridina. trans-stpy) e dos complexos binucleares [(CO)3(phen)Re(trans-bpe)Re(phen)(CO)3]2+, [(CO)3(phen)Re(trans-bpe)Fe(CN5]2- e [(phen)(CO)3Re(trans-bpe)Os(terpy)(bpy)]3+. O enfoque principal deste trabalho é a investigação das propriedades fotoquímicas dos complexos fac-[ Re(CO)3(phen)(trans-bpe)]+, fac-[Re(CO)3(phen)(trans-stpy)]+ fac-[Re(CO)3(dppz)(trans-bpe)+ e [(CO)3(phen)Re(trans-bpe)Re(phen)(CO)3]2+. Observou-se que os compostos em solução de acetonitrila, sob irradiação a 313, 334 ou 365 nm, apresentam variação espectral com definição de pontos isosbésticos, resultante do processo de fotoisomerização trans→cis do ligante coordenado trans-piridil etileno. Os rendimentos quânticos, Φ, da reação de fotoisomerização foram calculados com base no decaimento espectral das bandas de absorção das transições eletrônicas. Os valores médios determinados para a fotoisomeriação dos complexos em solução de CH3CN variam de 0,15 - 0,39 sob excitação a 313 nm e de 0,12 - 0,33 sob excitação a 365 nm. As reações de fotoisomerização foram monitoradas também por medidas de emissão e por RMN de 1H. Observou-se um aumento da intensidade de luminescência com o tempo de irradiação dos complexos, consistente com o estado emissivo 3MLCT dπ[(Re)→π*(α-diimina). Após irradiação, as reações de fotoisomerização dos complexos foram monitoradas por RMN de 1H. Os sinais de prótons do isômero trans tiveram um decréscimo gradual, enquanto que a intensidade dos sinais referentes aos prótons da espécie cis aumentaram. Os rendimentos quânticos para o processo de fotoisomerização dos complexos foram calculados através da integração das áreas dos sinais de prótons. Os valores obtidos foram maiores, pelo menos o dobro, que aqueles valores obtidos via espectroscopia UV-Vis. O comportamento fotoquímico dos complexos incorporados em polimetacrilato de metila, PMMA, foi também investigado. A fotólise cios complexos em filmes de PMMA conduz à variação espectral, de absorção e emissão, similar àquela observada em solução de acetonitrila, atribuícla ao processo de fotoisomerização trans → cis do ligante coordenado. Este estudo mostra que a fotoisomerização do ligante coordenado trans-piridil etileno pode ser promovida também em meio rígido. Essa característica. típica de um dispositivo molecular, pode ser convenientemente explorada no desenvolvimento de fotossensores. As medidas de TRIR mostram que o estado excitado de menor energia para o fac-[Re(CO)3(phen)(trans-bpe)+ é o 3ππ*. Para o fac-[Re(CO)3(phen)(cis-bpe)]+ a ordem dos estados excitados aparecem invertidas com o 3MLCT <3ππ*, evidenciado pela emissão do complexo cis à temperatura ambiente. Nas espécies binucleares, [(phen) Re(CO)3(trans-bpe)Os(terpy)(bpy)]3+ e [(CO)3(phen)Re(trans-bpe)Fe(CN)5]2-, a fotoisomerização trans → cis do ligante coordenado trans-bpe, característica da subunidade fac-[Re(CO)3(phen)(trans-bpe)]+, é inibida pela competição de transferência de energia intramolecular. Em meio rígido, em PMMA ou em EPA a 77 K, os máximos de emissão dos complexos fac-[Re(CO)3(phen)(cis-bpe)]+, fac-[Re(CO)3(phen)(cis-stpy)r e [(CO)3(phen)Re(cis-bpe)Re(phen)(CO)3]2+ sofrem um deslocamento hipsocrômico com o aumento da rigidez do meio. As mudanças nas propriedades emissivas, em termos de energia e tempo de vida do estado excitado, são discutidas baseadas no efeito rigidocrômico luminescente. O trabalho mostra uma forma interessante de fotos sensibilizar um substrato orgâmco usando o fato de que a coordenação estende a absorção do ligante a uma região de comprimento de onda maior e promove a fotoisomerização assistida por complexos metálicos em energias menores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudou-se o processo de absorção e dessorção de CO2 em solução aquosa da mistura de metildietanolamina (MDEA) e piperazina (PZ). Os ensaios de absorção foram realizados numa coluna de parede molhada com promotor de película, e, os ensaios de dessorção num sistema de semibatelada, ambos em escala de laboratório. Os testes experimentais de absorção foram realizados a 298 K e pressão atmosférica, com vazão de gás (CO2 e ar atmosférico) de 2,2.10-4 m3 s-1 e as seguintes vazões de líquido: 1,0.10-6; 1,3.10-6 e 1,7.10-6 m3 s-1. O sistema de absorção foi caracterizado através da determinação da área interfacial, a, o coeficiente volumétrico de transferência de massa, kGa, e o coeficiente volumétrico global médio de transferência de massa, KGa. No caso dos ensaios de dessorção, estes foram realizados nas temperaturas de 353, 363 e 368 K, onde empregou-se uma solução carbonatada de 10% PZ-20% MDEA e uma corrente de ar atmosférico nas vazões de 1,1.10-5 m3 s-1 e 2,7.10-5 m3 s-1. Este sistema foi caracterizado através da determinação do coeficiente volumétrico global de transferência de massa, KLa. Os resultados experimentais da área interfacial mostram que este é função da vazão do líquido, sugerindo uma maior área de irrigação como o aumento desta, onde teve-se uma maior área de transferência de massa. O resultado do parâmetro, KGa, indica uma dependência da vazão de líquido, a qual está associada à variação da área interfacial e à dependência do parâmetro KG com o perfil das concentrações da MDEA e PZ ao longo da coluna. A partir da teoria do duplo filme e pelo conhecimento dos parâmetros KGa, a e kGa, estimou-se um parâmetro cinético-difusivo associado à fase líquida, (( ) ) . Os resultados experimentais mostram que esse parâmetro varia pouco com a vazão de líquido, indicando tratar-se de um processo independente da hidrodinâmica do líquido, característico de sistemas com reação rápida. A concentração das aminas e carbamatos, nos ensaios de absorção e dessorção, foi determinada através dos modelos de calibração obtidas pela técnica de espectroscopia no infravermelho. Nos ensaios de absorção, foram observados que a concentração de PZ teve uma variação considerável (4 a 5% massa massa-1), entanto que a de MDEA variou pouco (0,3 a 0,5% massa massa-1), sugerindo que o processo de absorção de CO2 na mistura MDEA-PZ é controlado principalmente pela PZ, e supõe-se que a MDEA tem um papel de receptor de prótons procedentes da reação entre a PZ e o CO2. Nos ensaios de dessorção, observou-se que esse processo é afetado pela temperatura, sendo que, em temperaturas perto da ebulição (372 K), a taxa de dessorção de CO2 é maior do que em temperaturas menores, em certa forma é devido à dependência da velocidade de reação química com a temperatura. Os resultados do parâmetro KLa indicam que este diminui em função da concentração de carbamato de PZ (por exemplo, na temperatura de 368 K, de 7,5.10-4 a 1,0.10-4 s-1), devido a que este componente é decomposto em altas temperaturas gerando o CO2 e as aminas, sugerindo uma diminuição na velocidade de dessorção de CO2. Assim também, os resultados experimentais do parâmetro KLa indicam que este aumenta ligeiramente com a vazão do gás.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work was developed with the objective of proposing a simple, fast and versatile methodological routine using near-infrared spectroscopy (NIR) combined with multivariate analysis for the determination of ash content, moisture, protein and total lipids present in the gray shrimp (Litopenaeus vannamei ) which is conventionally performed gravimetrically after ashing at 550 ° C gravimetrically after drying at 105 ° C for the determination of moisture gravimetrically after a Soxhlet extraction using volumetric and after digestion and distillation Kjedhal respectively. Was first collected the spectra of 63 samples processed boiled shrimp Litopenaeus vannamei species. Then, the determinations by conventional standard methods were carried out. The spectra centered average underwent multiplicative scattering correction of light, smoothing Saviztky-Golay 15 points and first derivative, eliminated the noisy region, the working range was from 1100,36 to 2502,37 nm. Thus, the PLS models for predicting ash showed R 0,9471; 0,1017 and RMSEP RMSEC 0,1548; Moisture R was 0,9241; 2,5483 and RMSEP RMSEC 4,1979; R protein to 0,9201; 1,9391 and RMSEP RMSEC 2,7066; for lipids R 0,8801; 0,2827 and RMSEP RMSEC 0,2329 So that the results showed that the relative errors found between the reference method and the NIR were small and satisfactory. These results are an excellent indication that you can use the NIR to these analyzes, which is quite advantageous, since conventional techniques are time consuming, they spend a lot of reagents and involve a number of professionals, which requires a reasonable runtime while after the validation of the methodology execution using NIR reduces all this time to a few minutes, saving reagents, time and without waste generation, and that this is a non-destructive technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, it was developed and validated methodologies that were based on the use of Infrared Spectroscopy Mid (MIR) combined with multivariate calibration Square Partial Least (PLS) to quantify adulterants such as soybean oil and residual soybean oil in methyl and ethyl palm biodiesels in the concentration range from 0.25 to 30.00 (%), as well as to determine methyl and ethyl palm biodiesel content in their binary mixtures with diesel in the concentration range from 0.25 to 30.00 (%). The prediction results showed that PLS models constructed are satisfactory. Errors Mean Square Forecast (RMSEP) of adulteration and content determination showed values of 0.2260 (%), with mean error (EM) with values below 1.93 (%). The models also showed a strong correlation between actual and predicted values, staying above 0.99974. No systematic errors were observed, in accordance to ASTM E1655- 05. Thus the built PLS models, may be a promising alternative in the quality control of this fuel for possible adulterations or to content determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biodiesel is a renewable fuel derived from vegetable oils or animal fats, which can be a total or partial substitute for diesel. Since 2005, this fuel was introduced in the Brazilian energy matrix through Law 11.097 that determines the percentage of biodiesel added to diesel oil as well as monitoring the insertion of this fuel in market. The National Agency of Petroleum, Natural Gas and Biofuels (ANP) establish the obligation of adding 7% (v/v) of biodiesel to diesel commercialized in the country, making crucial the analytical control of this content. Therefore, in this study were developed and validated methodologies based on the use of Mid Infrared Spectroscopy (MIR) and Multivariate Calibration by Partial Least Squares (PLS) to quantify the methyl and ethyl biodiesels content of cotton and jatropha in binary blends with diesel at concentration range from 1.00 to 30.00% (v/v), since this is the range specified in standard ABNT NBR 15568. The biodiesels were produced from two routes, using ethanol or methanol, and evaluated according to the parameters: oxidative stability, water content, kinematic viscosity and density, presenting results according to ANP Resolution No. 45/2014. The built PLS models were validated on the basis of ASTM E1655-05 for Infrared Spectroscopy and Multivariate Calibration and ABNT NBR 15568, with satisfactory results due to RMSEP (Root Mean Square Error of Prediction) values below 0.08% (<0.1%), correlation coefficients (R) above 0.9997 and the absence of systematic error (bias). Therefore, the methodologies developed can be a promising alternative in the quality control of this fuel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se investiga la concentración de cationes (Ca,Fe,K,Mg),en el frijol negro,(Phaseolus vulgaris L. var. Tineco), usando un analizador de absorción atómica. Para tal efecto se procede a secar la muestra y luego se digiere en un medio acido. Se preparan las soluciones standard correspondiente a los cationes que se quiere investigar y luego se comparan estas concentraciones con las concentraciones de los iones en la muestra. El cálculo de la concentración (desconocida), de los cationes en la muestra, se hace por medio de simple aritmética. En este trabajo se reporta la cantidad en p. p. m. de los elementos arriba mencionados, presente en un gramo de la muestra original. Los resultados obtenidos fueron: Fe = 337.5 p. p. m. ; Ca = 150 p. p. m. ; Mg = 150 p. p. m. y K = 4X104p. p. m.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the social and economic importance that the milk has, the objective of this study was to evaluate the incidence and quantifying antimicrobial residues in the food. The samples were collected in dairy industry of southwestern Paraná state and thus they were able to cover all ten municipalities in the region of Pato Branco. The work focused on the development of appropriate models for the identification and quantification of analytes: tetracycline, sulfamethazine, sulfadimethoxine, chloramphenicol and ampicillin, all antimicrobials with health interest. For the calibration procedure and validation of the models was used the Infrared Spectroscopy Fourier Transform associated with chemometric method based on Partial Least Squares regression (PLS - Partial Least Squares). To prepare a work solution antimicrobials, the five analytes of interest were used in increasing doses, namely tetracycline from 0 to 0.60 ppm, sulfamethazine 0 to 0.12 ppm, sulfadimethoxine 0 to 2.40 ppm chloramphenicol 0 1.20 ppm and ampicillin 0 to 1.80 ppm to perform the work with the interest in multiresidues analysis. The performance of the models constructed was evaluated through the figures of merit: mean square error of calibration and cross-validation, correlation coefficients and offset performance ratio. For the purposes of applicability in this work, it is considered that the models generated for Tetracycline, Sulfadimethoxine and Chloramphenicol were considered viable, with the greatest predictive power and efficiency, then were employed to evaluate the quality of raw milk from the region of Pato Branco . Among the analyzed samples by NIR, 70% were in conformity with sanitary legislation, and 5% of these samples had concentrations below the Maximum Residue permitted, and is also satisfactory. However 30% of the sample set showed unsatisfactory results when evaluating the contamination with antimicrobials residues, which is non conformity related to the presence of antimicrobial unauthorized use or concentrations above the permitted limits. With the development of this work can be said that laboratory tests in the food area, using infrared spectroscopy with multivariate calibration was also good, fast in analysis, reduced costs and with minimum generation of laboratory waste. Thus, the alternative method proposed meets the quality concerns and desired efficiency by industrial sectors and society in general.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The routine analysis for quantization of organic acids and sugars are generally slow methods that involve the use and preparation of several reagents, require trained professional, the availability of special equipment and is expensive. In this context, it has been increasing investment in research whose purpose is the development of substitutive methods to reference, which are faster, cheap and simple, and infrared spectroscopy have been highlighted in this regard. The present study developed multivariate calibration models for the simultaneous and quantitative determination of ascorbic acid, citric, malic and tartaric and sugars sucrose, glucose and fructose, and soluble solids in juices and fruit nectars and classification models for ACP. We used methods of spectroscopy in the near infrared (Near Infrared, NIR) in association with the method regression of partial least squares (PLS). Were used 42 samples between juices and fruit nectars commercially available in local shops. For the construction of the models were performed with reference analysis using high-performance liquid chromatography (HPLC) and refractometry for the analysis of soluble solids. Subsequently, the acquisition of the spectra was done in triplicate, in the spectral range 12500 to 4000 cm-1. The best models were applied to the quantification of analytes in study on natural juices and juice samples produced in the Paraná Southwest Region. The juices used in the application of the models also underwent physical and chemical analysis. Validation of chromatographic methodology has shown satisfactory results, since the external calibration curve obtained R-square value (R2) above 0.98 and coefficient of variation (%CV) for intermediate precision and repeatability below 8.83%. Through the Principal Component Analysis (PCA) was possible to separate samples of juices into two major groups, grape and apple and tangerine and orange, while for nectars groups separated guava and grape, and pineapple and apple. Different validation methods, and pre-processes that were used separately and in combination, were obtained with multivariate calibration models with average forecast square error (RMSEP) and cross validation (RMSECV) errors below 1.33 and 1.53 g.100 mL-1, respectively and R2 above 0.771, except for malic acid. The physicochemical analysis enabled the characterization of drinks, including the pH working range (variation of 2.83 to 5.79) and acidity within the parameters Regulation for each flavor. Regression models have demonstrated the possibility of determining both ascorbic acids, citric, malic and tartaric with successfully, besides sucrose, glucose and fructose by means of only a spectrum, suggesting that the models are economically viable for quality control and product standardization in the fruit juice and nectars processing industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação (Mestrado em Tecnologia Nuclear)