924 resultados para Equipment, laryngeal mask


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors studied the utility of the physical test of laryngeal movement in swallowing disorders of the oropharyngeal region. Measurement and palpation of the larynx during deglutition were performed in the neck of 14 dysphagic patients and in two normal control groups. The normal groups were used to establish the pattern of the movement and the normal values of laryngeal elevation. Control elevation ranged from 1.80 to 2.50 cm. In eight patients laryngeal motion was defective and presented values ranging from zero to 1.50 cm. Palpation during laryngeal movement also revealed unexpected anomalous displacement such as lateral shifting and lowering of the larynx. In six patients with defective laryngeal motion, pharyngeal and upper esophageal sphincter function were also impaired. Direct measurement and palpation of laryngeal mobility during deglutition is a noninvasive method that can be used to evaluate dysphagia and the risk for aspiration. Also, it allows physical assessment of the evolution of the disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative analysis of normal values of motor unit action potentials duration and amplitude of muscles tireoaritenoideus (TA), cricotireoideus (CT), cricoaritenoideus lateralis (CAL), and cricoaritenoideus posterioris (CAP) was performed in 14 adult normal Brazilian volunteers. The recordings were obtained by percutaneously inserted concentric needle electrode. Different motor unit action potentials were manually selected in each muscle for quantitative computerized analysis of duration and amplitude. The mean values for duration and amplitude were respectively 3.8 ms and 413 μV for TA, 4.9 ms and 585 μV for CT, 4.1 ms and 388 μV for CAL and 4.5 ms and 475 μV in CAP. There were no similar reports of normal values of motor unit action potentials in Brazilian subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laryngeal Electromyography (LEMG) is an auxiliary diagnostic method used for the comprehension and diagnosis of different neurological diseases that compromise laryngeal function. The most common LEMG technique is the percutaneous insertion of needle electrodes guided by surface anatomical references. We describe techniques for inserting needle electrodes into the tireoaritenoideus (TA), cricotireoideus (CT), cricoaritenoideus lateralis (CAL) and cricoaritenoideus posterioris (CAP) muscles; these are used at UNICAMP laryngology ambulatory; we discuss difficulties found and their proposed solutions. All patients were submitted to otorhinolaryngological, phonoaudiological and laryngeal endoscopy before LEMG. The CAP approach, by digital rotation of the thyroid cartilage was found to be the most difficult, followed by the CAL approach. TA and CT approaches gave no major problems, except with some older and obese patients. A significant complication of the TA approach via thyroid cartilage was a hematoma in one patient which partially obstructed the laryngeal lumen.