997 resultados para ELECTRICAL-RESISTIVITY TOMOGRAPHY


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polymer films, deposited from acetylene and argon plasma mixtures, were bombarded with 150 keV He+ ions, varying the fluence, Phi, from 10(18) to 10(21) ions/m(2). Molecular structure and optical gap of the samples were investigated by infrared and ultraviolet-visible spectroscopies, respectively. Two-point probe was employed to determine the electrical resistivity while hardness was measured by nanoindentation technique. It was verified modification of the molecular structure and composition of the films. There was loss of H and increment in the concentration of unsaturated carbon bonds with Phi. Optical gap and electrical resistivity decreased while hardness increased with Phi. Interpretation of these results is proposed in terms of chain crosslinking and unsaturation. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O etanol é utilizado de forma extensiva como combustível para veículos automotores no Brasil, devido tanto a características como ao clima favorável ao cultivo de cana-de-açúcar em uma cadeia produtiva bastante desenvolvida quanto à eficiência energética e ao teor quase inexistente de poluentes emitidos emsua combustão. A ampla rede de distribuição para atendimento ao consumidor final representa um risco constante de vazamentos e contaminação de rios, solo e água subterrânea. Este trabalho discute os resultados do monitoramento geofísico num experimento em escala de laboratório, resultante do vazamento controlado de etanol em sedimentos parcialmente saturados em água. A extensa aplicação de métodos elétricos em estudos ambientais e alterações significativas em termos de resistividade elétrica, provocada no ambiente geológico pela presença de compostos exógenos, justifica a seleção do método. Houve um aumento dos valores no início do experimento até o máximo em torno de 52h, seguido por queda acentuada até 342h e sucedido por crescimento lento e constante dos valores até 2.742h, quando comparados a valores prévios sem adição de etanol. Os dados sugerem uma relação temporal entre variações de resistividade elétrica e o comportamento geoquímico do etanolno ambiente geológico.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the results of electrical resistivity methods in the area delineation that was potentially contaminated by liquefaction products, which are also called putrefactive liquids in Vila Rezende municipal cemetery, Piracicaba, So Paulo, Brazil. The results indicate a depth of water table between 3.1 and 5.1 m, with two groundwater direction flows, one to the SW and another to the SE. Due to the contamination plumes, which have the same groundwater direction flow, as well the conductive anomalies observed in the geoelectric sections, the contamination suspicions in the area were confirmed. The probable plume to the SE extends beyond the limits of the cemetery. The location of the conductive anomalies and the probable contamination plumes showed that the contamination is linked with the depth of the water table and the burial time. Mapping using the geostatistical method of ordinary kriging applied to the work drew structural characteristics of the regional phenomenon and spatial behavior of the electrical resistivity data, resulting in continued surfaces. Thus, this method has proved to be an important tool for mapping contamination plumes in cemeteries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The order-disorder transformation in the Ni-4.49 at.% Al alloy was studied using electrical resistivity measurements, microhardness measurements, differential scanning calorimetry (DSC) and transmission electron microscopy (TEM). The results confirmed the ordering behavior expected for Ni-Al dilute alloys and the suggested relation between resistivity changes and microhardness changes with antiferromagnetic spin ordering. The higher value obtained for the activation energy of vacancy migration was associated with a decrease in the Al concentration gradient near solute-depleted regions. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Estudos de pesquisa mineral são fundamentais para o reconhecimento e a incorporação de novas reservas. Esse trabalho apresenta os resultados de aplicação do método geofísico da eletrorresistividade numa ocorrência mineralizada em carbonatos de cobre, por meio da técnica de caminhamento elétrico em arranjo azimutal. A área de estudos está inserida na bacia sedimentar do Camaquã, formada por um conjunto de unidades estratigráficas sedimentares e vulcanogênicas, onde são descritas diversas ocorrências cupríferas. A presença de azurita e malaquita em fraturas e zonas de maior porosidade em arenito encaixante define a geologia local. Os modelos de inversão revelam anomalias circulares de resistividade moderada para até 25m abaixo da ocorrência aflorante e anomalias de baixa resistividade em profundidades abaixo de 25m, além de áreas adjacentes com alta resistividade. Indicadores de mineralização descritos para ocorrências de cobre estudadas, no âmbito da bacia sedimentar do Camaquã, ocorrem na área de estudos e permitem caracterização em termos de resistividade elétrica. Áreas com silicificação apresentam alta resistividade, enquanto que valores intermediários são atribuídos a zonas com carbonatação e, finalmente, áreas de baixa resistividade, provavelmente, indicam concentrações de sulfetos disseminados.