871 resultados para Dyes in medical diagnosis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Meta-analysis, the statistical combination of results from several studies to produce a single estimate of a treatment effect or size of an association, continues to attract controversy. We illustrate and discuss the promises and limitations of meta-analysis. Meta-analysis of clinical trials can prevent delays in the introduction of effective treatments or lead to the timely identification of adverse effects. However, meta-analyses are liable to numerous biases, both at the level of the individual study and the selection of studies for inclusion in meta-analysis. The biases and confounding factors that threaten the validity of individual studies will also affect meta-analyses of observational studies. We argue that meta-analyses should only be performed within the framework of systematic reviews that have been prepared using methods that minimize bias and address the combinability of studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Medical microdevices have gained popularity in the past few decades because they allow the medical laboratory to be taken out into the field and for disease diagnostics to happen with a smaller sample volume, at a lower cost and much faster. Blood is the human body's most readily available and informative diagnostic fluid because of the wealth of information it provides about the body's general health including enzymatic, proteomic and immunological states. The purpose of this project is to optimize operating conditions and study ABO-Rh erythrocytes dielectrophoretic responses to alternating current electric signals. The end goal of this project is the creation of a relatively inexpensive microfluidic device, which can be used for the ABO-Rh typing of a blood sample. This dissertation presents results showing how blood samples of a known ABO- Rh blood type exhibit differing behavior to the same electrical stimulus based on their blood type. The first panel of donors and experiments, presented in Chapter 4 occurred when a sample of known blood type was injected into a microdevice with a T-shaped electrode configuration and the erythorcytes were found to rupture at a rate specific to their ABO-Rh blood type. The second set of experiments, presented in Chapter 5, were originally published in Electrophoresis in 20111. Novel in this work was the discovery that treatment of human erythrocytes with β-galactosidase successfully removed ABO surface antigens such that native A and B blood no longer agglutinated with the proper antibodies. This work was performed in a medium of conductivity 0.9S/m which is close to the measured conductivity of pooled plasma (~1.1S/m). The ability to perform dielectrophoresis experiments at physiological conductivities conditions is advantageous for future portable devices because the device/instrument would not need to store dilution buffers. The final results of this project, presented in Chapter 6, explore the entire dielectrophoretic spectra of the ABO-Rh erythrocytes including the cross-over frequency and the magnitudes of the positive or negative dielectrophoretic response. These were completed at lower medium conductivities of 0.1S/m and 0.01-0.04S/m. These results show that by using the sweep function built into the Agilent alternating current generator it is possible to explore how a single group of blood cells will react to rapid changes in frequency and will provide the user with curve that can be matched the theoretical dielectrophoretic response curves. As a whole this project shows that it is possible to distinguish human erythrocytes by their ABO-Rh blood type via three different dielectrophoretic methods. This work builds on the foundation of that it is possible to distinguish healthy from infected cells2-7, similar cell types1,7-14 and other work regarding the dielectrophoresis of human erythrocytes1,10,11. This work has implications in both medical diagnostics and future dielectrophoretic work because it has shown that ABO-Rh blood type is now a factor, which must be identified when working with a human blood sample. It also shows that the creation of a microfluidic device that subjects human erythrocytes to a dielectrophoretic impulse and then exports an ABO-Rh blood type is a near future possibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXT: Magnetic resonance imaging (MRI) combined with magnetic resonance spectroscopy imaging (MRSI) emerged as a promising test in the diagnosis of prostate cancer and showed encouraging results. OBJECTIVE: The aim of this systematic review is to meta-analyse the diagnostic accuracy of combined MRI/MRSI in prostate cancer and to explore risk profiles with highest benefit. EVIDENCE ACQUISITION: The authors searched the MEDLINE and EMBASE databases and the Cochrane Library, and the authors screened reference lists and contacted experts. There were no language restrictions. The last search was performed in August 2008. EVIDENCE SYNTHESIS: We identified 31 test-accuracy studies (1765 patients); 16 studies (17 populations) with a total of 581 patients were suitable for meta-analysis. Nine combined MRI/MRSI studies (10 populations) examining men with pathologically confirmed prostate cancer (297 patients; 1518 specimens) had a pooled sensitivity and specificity on prostate subpart level of 68% (95% CI, 56-78%) and 85% (95% CI, 78-90%), respectively. Compared with patients at high risk for clinically relevant cancer (six studies), sensitivity was lower in low-risk patients (four studies) (58% [46-69%] vs 74% [58-85%]; p>0.05) but higher for specificity (91% [86-94%] vs 78% [70-84%]; p<0.01). Seven studies examining patients with suspected prostate cancer at combined MRI/MRSI (284 patients) had an overall pooled sensitivity and specificity on patients level of 82% (59-94%) and 88% (80-95%). In the low-risk group (five studies) these values were 75% (39-93%) and 91% (77-97%), respectively. CONCLUSIONS: A limited number of small studies suggest that MRI combined with MRSI could be a rule-in test for low-risk patients. This finding needs further confirmation in larger studies and cost-effectiveness needs to be established.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Textbooks, across all disciplines, are prone to contain errors; grammatical, editorial, factual, or judgemental. The following is an account of one of the possible effects of such errors; how an error becomes entrenched and even exaggerated as later textbooks fail to correct the original error. The example considered here concerns the origins of one of the most basic and important tools of to­ day's medical research, the randomised controlled trial. It is the result of a systematic study of 26 British, French and German history of medicine textbooks since 1996.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IMPORTANCE Because effective interventions to reduce hospital readmissions are often expensive to implement, a score to predict potentially avoidable readmissions may help target the patients most likely to benefit. OBJECTIVE To derive and internally validate a prediction model for potentially avoidable 30-day hospital readmissions in medical patients using administrative and clinical data readily available prior to discharge. DESIGN Retrospective cohort study. SETTING Academic medical center in Boston, Massachusetts. PARTICIPANTS All patient discharges from any medical services between July 1, 2009, and June 30, 2010. MAIN OUTCOME MEASURES Potentially avoidable 30-day readmissions to 3 hospitals of the Partners HealthCare network were identified using a validated computerized algorithm based on administrative data (SQLape). A simple score was developed using multivariable logistic regression, with two-thirds of the sample randomly selected as the derivation cohort and one-third as the validation cohort. RESULTS Among 10 731 eligible discharges, 2398 discharges (22.3%) were followed by a 30-day readmission, of which 879 (8.5% of all discharges) were identified as potentially avoidable. The prediction score identified 7 independent factors, referred to as the HOSPITAL score: h emoglobin at discharge, discharge from an o ncology service, s odium level at discharge, p rocedure during the index admission, i ndex t ype of admission, number of a dmissions during the last 12 months, and l ength of stay. In the validation set, 26.7% of the patients were classified as high risk, with an estimated potentially avoidable readmission risk of 18.0% (observed, 18.2%). The HOSPITAL score had fair discriminatory power (C statistic, 0.71) and had good calibration. CONCLUSIONS AND RELEVANCE This simple prediction model identifies before discharge the risk of potentially avoidable 30-day readmission in medical patients. This score has potential to easily identify patients who may need more intensive transitional care interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bovine besnoitiosis is considered an emerging chronic and debilitating disease in Europe. Many infections remain subclinical, and the only sign of disease is the presence of parasitic cysts in the sclera and conjunctiva. Serological tests are useful for detecting asymptomatic cattle/sub-clinical infections for control purposes, as there are no effective drugs or vaccines. For this purpose, diagnostic tools need to be further standardized. Thus, the aim of this study was to compare the serological tests available in Europe in a multi-centred study. A coded panel of 241 well-characterized sera from infected and non-infected bovines was provided by all participants (SALUVET-Madrid, FLI-Wusterhausen, ENV-Toulouse, IPB-Berne). The tests evaluated were as follows: an in-house ELISA, three commercial ELISAs (INGEZIM BES 12.BES.K1 INGENASA, PrioCHECK Besnoitia Ab V2.0, ID Screen Besnoitia indirect IDVET), two IFATs and seven Western blot tests (tachyzoite and bradyzoite extracts under reducing and non-reducing conditions). Two different definitions of a gold standard were used: (i) the result of the majority of tests ('Majority of tests') and (ii) the majority of test results plus pre-test information based on clinical signs ('Majority of tests plus pre-test info'). Relative to the gold standard 'Majority of tests', almost 100% sensitivity (Se) and specificity (Sp) were obtained with SALUVET-Madrid and FLI-Wusterhausen tachyzoite- and bradyzoite-based Western blot tests under non-reducing conditions. On the ELISAs, PrioCHECK Besnoitia Ab V2.0 showed 100% Se and 98.8% Sp, whereas ID Screen Besnoitia indirect IDVET showed 97.2% Se and 100% Sp. The in-house ELISA and INGEZIM BES 12.BES.K1 INGENASA showed 97.3% and 97.2% Se; and 94.6% and 93.0% Sp, respectively. IFAT FLI-Wusterhausen performed better than IFAT SALUVET-Madrid, with 100% Se and 95.4% Sp. Relative to the gold standard 'Majority of test plus pre-test info', Sp significantly decreased; this result was expected because of the existence of seronegative animals with clinical signs. All ELISAs performed very well and could be used in epidemiological studies; however, Western blot tests performed better and could be employed as a posteriori tests for control purposes in the case of uncertain results from valuable samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: This study addresses how to best approach the instruction and evaluation of clinical ethics with preclinical medical students. [See PDF for complete abstract]

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces an extended hierarchical task analysis (HTA) methodology devised to evaluate and compare user interfaces on volumetric infusion pumps. The pumps were studied along the dimensions of overall usability and propensity for generating human error. With HTA as our framework, we analyzed six pumps on a variety of common tasks using Norman’s Action theory. The introduced method of evaluation divides the problem space between the external world of the device interface and the user’s internal cognitive world, allowing for predictions of potential user errors at the human-device level. In this paper, one detailed analysis is provided as an example, comparing two different pumps on two separate tasks. The results demonstrate the inherent variation, often the cause of usage errors, found with infusion pumps being used in hospitals today. The reported methodology is a useful tool for evaluating human performance and predicting potential user errors with infusion pumps and other simple medical devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

QUESTION UNDER STUDY Handling emergency telephone consultations (ETCs) is a challenging and very important task for doctors. The aims of the study were to document insecurity in medical students during ETCs and to identify the reasons for that insecurity. We hypothesised that insecurity is associated with advising more urgent action (e.g. advice to call for an ambulance) in ETCs. METHODS We used ETCs with simulated patients (SPs), with each student randomly allocated two of four possible cases. After the training, 137 students reported on any insecurity that they had in the various ETC phases. We analysed the reasons for insecurity using descriptive statistics. The association between the students' advice that urgent action was needed and their insecurity was analysed with Spearman rank correlation. RESULTS Overall, 95% of the students felt insecure in at least one phase of their ETC. History taking was the phase in which students felt most insecure (63.1%), followed by the phase of analysing the information given by the patient (44.9%). Perceived insecurity was associated with more urgent advice in one case scenario (abdominal pain; correlation r = 0.46; p <0.01). The other two cases (child with fever; chest pain) also had a positive, but not statistically significant, correlation trend (p <0.12; p <0.08). CONCLUSIONS Insecurity is highly prevalent among medical students in their ETC decision-making. ETC training in medical schools, with a focus on structured history taking and formulating discriminating questions, might help decrease insecurity in ETCs. Medical education should also teach management of insecurity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The immotile cilia syndrome (ICS) comprises a range of congenital defects of the ciliary apparatus most probably transmitted by autosomal recessive inheritance. Because cilia occur mainly in the respiratory and genital tract, the clinical symptoms of ICS are most commonly chronic sinusitis, bronchitis, bronchiectasis and male sterility. The syndrome can be associated with a situs inversus and is then called Kartagener's syndrome. We studied the ciliary ultrastructure in airway biopsies of 5 patients suffering from chronic upper and lower respiratory tract infections. With the single exception of one female patient with confirmed ICS diagnosis (Kartagener's syndrome) the etiology of the recurrent infections was unknown. The following ciliary defects were observed: missing dynein arms, radial spoke defects, missing nexin links, microtubular transpositions, compound cilia, supernumerary, absent, or incomplete microtubules, lack of ciliary orientation and various abnormal patterns of microtubular arrangement. In no instance did a patient show only a single anomaly; defects were always combined. Missing dynein arms, radial spoke defects and microtubular transpositions have frequently been described as lesions specific for ICS. Whenever these lesions were found simultaneously in both the respiratory and genital tracts, their genetic origin cannot be doubted. In our confirmed ICS patient the outer dynein arms were not missing but were reduced in number and length in a large number of cilia. The biopsy was, however, obtained from the heavily infected maxillary sinus and it is known that inflammation can lead to a loss of dynein arms. In the light of our investigations and of a review of the published cases of ciliary anomalies, it is concluded that none of the above defects in itself is specific for ICS. They may all occur as secondary lesions or sporadically as varieties in otherwise healthy subjects. It therefore appears questionable whether ICS can be diagnosed from the ciliary ultrastructure of a single airway biopsy. Assessment of ICS cannot be based simply on the ultrastructural demonstration of a particular ciliary defect, but necessitates additional considerations particularly regarding the origin of the biopsy, the sampling procedures and quantitation of defects. It appears necessary to investigate samples from different parts of the airways and quantitatively analyze the prominent lesions.