997 resultados para Double Strap Joint
Resumo:
Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a double colour laser scanned photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the colour detection process are analysed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.
Resumo:
Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a Double Color Laser Scanned Photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the color detection process are analyzed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.
Resumo:
O documento em anexo encontra-se na versão post-print (versão corrigida pelo editor).
Resumo:
DESIGN: A randomized controlled trial.OB JECTIVE: To investigate the immediate effects on pressure pain thresholds over latent trigger points (TrPs) in the masseter and temporalis muscles and active mouth opening following atlanto-occipital joint thrust manipulation or a soft tissue manual intervention targeted to the suboccipital muscles. BACKGROUND : Previous studies have described hypoalgesic effects of neck manipulative interventions over TrPs in the cervical musculature. There is a lack of studies analyzing these mechanisms over TrPs of muscles innervated by the trigeminal nerve. METHODS: One hundred twenty-two volunteers, 31 men and 91 women, between the ages of 18 and 30 years, with latent TrPs in the masseter muscle, were randomly divided into 3 groups: a manipulative group who received an atlanto-occipital joint thrust, a soft tissue group who received an inhibition technique over the suboccipital muscles, and a control group who did not receive an intervention. Pressure pain thresholds over latent TrPs in the masseter and temporalis muscles, and active mouth opening were assessed pretreatment and 2 minutes posttreatment by a blinded assessor. Mixed-model analyses of variance (ANOVA) were used to examine the effects of interventions on each outcome, with group as the between-subjects variable and time as the within-subjects variable. The primary analysis was the group-by-time interaction. RESULTS: The 2-by-3 mixed-model ANOVA revealed a significant group-by-time interaction for changes in pressure pain thresholds over masseter (P<.01) and temporalis (P =.003) muscle latent TrPs and also for active mouth opening (P<.001) in favor of the manipulative and soft tissue groups. Between-group effect sizes were small. CONCLUSIONS: The application of an atlanto-occipital thrust manipulation or soft tissue technique targeted to the suboccipital muscles led to an immediate increase in pressure pain thresholds over latent TrPs in the masseter and temporalis muscles and an increase in maximum active mouth opening. Nevertheless, the effects of both interventions were small and future studies are required to elucidate the clinical relevance of these changes. LEVEL OF EVIDENCE : Therapy, level 1b. J Orthop Sports Phys Ther 2010;40(5):310-317. doi:10.2519/jospt.2010.3257. KEYWORDSDS: cervical manipulation, muscle trigger points, neck, TMJ, upper cervical.
Resumo:
In order to develop a flexible simulator, a variety of models for Ancillary Services (AS) negotiation has been implemented in MASCEM – a multi-agent system competitive electricity markets simulator. In some of these models, the energy and the AS are addressed simultaneously while in other models they are addressed separately. This paper presents an energy and ancillary services joint market simulation. This paper proposes a deterministic approach for solving the energy and ancillary services joint market. A case study based on the dispatch of Regulation Down, Regulation Up, Spinning Reserve, and Non-Spinning Reserve services is used to demonstrate that the use of the developed methodology is suitable for solving this kind of optimization problem. The presented case study is based on CAISO real AS market data considers fifteen bids.
Resumo:
Agência Financiadora: Fundação para a Ciência e a Tecnologia/MCTES (Portugal) - PEst-OE/EQB/UI0702/2012
Resumo:
The purpose of this study is to analyse the interlimb relation and the influence of mechanical energy on metabolic energy expenditure during gait. In total, 22 subjects were monitored as to electromyographic activity, ground reaction forces and VO2 consumption (metabolic power) during gait. The results demonstrate a moderate negative correlation between the activity of tibialis anterior, biceps femoris and vastus medialis of the trailing limb during the transition between midstance and double support and that of the leading limb during double support for the same muscles, and between these and gastrocnemius medialis and soleus of the trailing limb during double support. Trailing limb soleus during the transition between mid-stance and double support was positively correlated to leading limb tibialis anterior, vastus medialis and biceps femoris during double support. Also, the trailing limb centre of mass mechanical work was strongly influenced by the leading limbs, although only the mechanical power related to forward progression of both limbs was correlated to metabolic power. These findings demonstrate a consistent interlimb relation in terms of electromyographic activity and centre of mass mechanical work, being the relations occurred in the plane of forward progression the more important to gait energy expenditure.
Resumo:
Component joining is typically performed by welding, fastening, or adhesive-bonding. For bonded aerospace applications, adhesives must withstand high-temperatures (200°C or above, depending on the application), which implies their mechanical characterization under identical conditions. The extended finite element method (XFEM) is an enhancement of the finite element method (FEM) that can be used for the strength prediction of bonded structures. This work proposes and validates damage laws for a thin layer of an epoxy adhesive at room temperature (RT), 100, 150, and 200°C using the XFEM. The fracture toughness (G Ic ) and maximum load ( ); in pure tensile loading were defined by testing double-cantilever beam (DCB) and bulk tensile specimens, respectively, which permitted building the damage laws for each temperature. The bulk test results revealed that decreased gradually with the temperature. On the other hand, the value of G Ic of the adhesive, extracted from the DCB data, was shown to be relatively insensitive to temperature up to the glass transition temperature (T g ), while above T g (at 200°C) a great reduction took place. The output of the DCB numerical simulations for the various temperatures showed a good agreement with the experimental results, which validated the obtained data for strength prediction of bonded joints in tension. By the obtained results, the XFEM proved to be an alternative for the accurate strength prediction of bonded structures.
Resumo:
The investigation which employed the action research method (qualitative analysis)was divided into four fases. In phases 1-3 the participants were six double bass students at Nossa Senhora do Cabo Music School. Pilot exercises in creativity were followed by broader and more ambitious projects. In phase 4 the techniques were tested and amplified during a summer course for twelve double bass students at Santa Cecilia College.
Resumo:
We address the problem of coordinating two non-holonomic mobile robots that move in formation while transporting a long payload. A competitive dynamics is introduced that gradually controls the activation and deactivation of individual behaviors. This process introduces (asymmetrical) hysteresis during behavioral switching. As a result behavioral oscillations, due to noisy information, are eliminated. Results in indoor environments show that if parameter values are chosen within reasonable ranges then, in spite of noise in the robots communi- cation and sensors, the overall robotic system works quite well even in cluttered environments. The robots overt behavior is stable and smooth.
Resumo:
This work addresses both experimental and numerical analyses regarding the tensile behaviour of CFRP single-strap repairs. Two fundamental geometrical parameters were studied: overlap length and patch thickness. The numerical model used ABAQUS® software and a developed cohesive mixed-mode damage model adequate for ductile adhesives, and implemented within interface finite elements. Stress analyses and strength predictions were carried out. Experimental and numerical comparisons were performed on failure modes, failure load and equivalent stiffness of the repair. Good correlation was found between experimental and numerical results, showing that the proposed model can be successfully applied to bonded joints or repairs.
Resumo:
IET Control Theory & Applications, Vol. 1, Nº 1
Resumo:
A double-blind clinical trial involving 120 patients with chronic schistosomiasis was carried out to compare the tolerability and efficacy of praziquantel and oxamniquine. The patients were randomly allocated into two groups. One was treated with praziquantel, 55 mg/kg of body weight CBWT), and the other one with oxamniquine, 15mg/kg bwt, administered in a single oral dose. The diagnosis and the parasitological follow-up was based on stool examinations by quantitative Kato-Katz method and on rectal biopsies. Side-effects mainly dizziness, sleepness, abdominal distress, headache, nausea and diarrhea were observed in 87% of the cases. Their incidence, intensity and duration were similar for both drugs but abdominal pain was significantly more frequent after praziquantel intake and severe dizziness was more commonly reported after oxamniquine. A significant increase of alanine-aminotransferase and y-glutamyltransferase was found with the latter drug and of total bilirubin with the former one. A total of 48 patients treated with praziquantel and 46 with oxamniquine completed with negative findings the required three post-treatment parasitological controls three slides of each stool sample on the first, third and sixth month. The achieved cure rates were 79.2% and 84.8%, respectively, a difference without statistical significance. The non-cured cases showed a mean reduction in the number of eggs per gram of feces of 93.5% after praziquantel and of 84.1% after oxamniquine. This diference also was not significant. Five patients retreated with praziquantel were cured but only one out of three treated a second time with oxamniquine. These findings show that both drugs despite their different chemical structures, pharmacological properties and mechanisms-of-action induce similar side-effects as well as a comparable therapeutical efficacy, in agreement with the results reported from analogous investigations.
Resumo:
This article studies several Fractional Order Control algorithms used for joint control of a hexapod robot. Both Padé and series approximations to the fractional derivative are considered for the control algorithm. The walking performance is evaluated through two indices: The mean absolute density of energy used per unit distance travelled, and the control effort. A set of simulation experiments reveals the influence of the different approximations upon the proposed indices. The results show that the fractional proportional and derivative algorithm, implemented using the Padé approximation with a small number of terms, gives the best results.
Resumo:
Este trabalho descreve a abordagem abrangente sobre a melhoria do sistema de gestão da qualidade na Unidade de Imagiologia do Hospital da Boavista através da implementação das normas de acreditação da Joint Commission International (JCI). Fundamental para a melhoria geral da qualidade é a redução contínua de riscos para os doentes e para os profissionais da Unidade. Tais riscos podem existir ao nível do ambiente físico assim como no circuito dos exames e dos doentes. A acreditação em Saúde é uma das prioridades estratégicas do Ministério da Saúde e tem como objetivo fortalecer a confiança dos cidadãos nos profissionais de saúde bem como nas instituições de saúde. É importante que Portugal cultive a melhoria da qualidade e segurança nas instituições de saúde mantendo uma relação adequada custo/benefício. A União Europeia tem feito um esforço para que a acreditação seja harmoniosa nos seus princípios, no entanto é respeitada sempre a prevalência da legislação de cada país, bem como as suas especificações culturais e religiosas (Shaw, 2006), responsabilizando-o pelo seu sistema de saúde O trabalho aqui apresentado tem como objetivo principal fundamentar a escolha do modelo de acreditação da JCI para o Hospital da Boavista, nomeadamente para a Unidade de Imagiologia, ver se os padrões estão de acordo com os procedimentos da Unidade, identificar falhas e apontar possiveis melhorias. Pretende-se ainda mostrar a importância da implementação dos sistemas de certificação e acreditação da gestão da qualidade, documentada pela experiência profissional, bem como o know-how do Hospital da Boavista, assim como a complementaridade dos programas da gestão da qualidade, certificação e acreditação. A escolha do modelo de acreditação da JCI, foi uma opção do Hospital da Boavista baseada na credibilidade e no grau de exigência que a entidade impõe. Foi imperativo que a Unidade de Imagiologia realizasse as suas funções de forma válida e fiável e que disponibilizasse produtos / serviços de qualidade. A monitorização e consequente controlo de qualidade do serviço prestado pela Unidade de Imagiologia, foi difícil mas simplificado, em parte, devido ao sistema de gestão da qualidade ISO 9001:2008 já implementado, tendo este sido consolidado com a implementação da acreditação da JCI, com padrões específicos bem definidos na gestão do controlo de qualidade na Unidade de Imagiologia do Hospital da Boavista.