943 resultados para Digital processing
Resumo:
Digital pathology and the adoption of image analysis have grown rapidly in the last few years. This is largely due to the implementation of whole slide scanning, advances in software and computer processing capacity and the increasing importance of tissue-based research for biomarker discovery and stratified medicine. This review sets out the key application areas for digital pathology and image analysis, with a particular focus on research and biomarker discovery. A variety of image analysis applications are reviewed including nuclear morphometry and tissue architecture analysis, but with emphasis on immunohistochemistry and fluorescence analysis of tissue biomarkers. Digital pathology and image analysis have important roles across the drug/companion diagnostic development pipeline including biobanking, molecular pathology, tissue microarray analysis, molecular profiling of tissue and these important developments are reviewed. Underpinning all of these important developments is the need for high quality tissue samples and the impact of pre-analytical variables on tissue research is discussed. This requirement is combined with practical advice on setting up and running a digital pathology laboratory. Finally, we discuss the need to integrate digital image analysis data with epidemiological, clinical and genomic data in order to fully understand the relationship between genotype and phenotype and to drive discovery and the delivery of personalized medicine.
Resumo:
O objetivo deste trabalho foi efetuar um estudo de otimização dos parâmetros de exposição do mamógrafo digital da marca GE, modelo Senographe DS instalado no Instituto Português de Oncologia de Coimbra (IPOC) baseado numa análise contraste detalhe e avaliar o impacto do resultado obtido na melhoria da capacidade de detecção clínica das estruturas da mama. O mamógrafo em estudo dispõe de um sistema de controle automático da exposição designado por sistema AOP (Automatic Optimization of Parameters) que foi otimizado pelo fabricante a partir da razão contraste ruído. O sistema AOP é usado na prática clínica na quase totalidade dos exames de mamografia realizados no IPOC. Tendo em conta o tipo de estrutura que se pretende visualizar na mamografia, nomeadamente estruturas de baixo contraste como as massas e estruturas de dimensão submilimétrica como as microcalcificações, a análise contraste detalhe poderia constituir uma abordagem mais adequada para o estudo de otimização dos parâmetros de exposição uma vez que permitiria uma avaliação conjunta do contraste, da resolução espacial e do ruído da imagem. Numa primeira fase do trabalho foi efetuada a caracterização da prática clínica realizada no mamógrafo em estudo em termos de espessura de mama comprimida “típica”, dos parâmetros técnicos de exposição e das opções de processamento das imagens aplicadas pelo sistema AOP (combinação alvo/filtro, tensão aplicada na ampola - kVp e produto corrente-tempo da ampola - mAs). Numa segunda fase foi realizado um estudo de otimização da qualidade da imagem versus dose na perspectiva dos parâmetros físicos. Para tal foi efetuada uma análise contrastedetalhe no objeto simulador de mama CDMAM e usada uma figura de mérito definida a partir do IQFinv (inverted image quality figure) e da dose glandular média. Os resultados apontaram para uma diferença entre o ponto ótimo resultante do estudo de otimização e o ponto associado aos parâmetros de exposição escolhidos pelo sistema AOP, designadamente no caso da mama pequena. Sendo a qualidade da imagem na perspectiva clínica um conceito mais complexo cujo resultado da apreciação de uma imagem de boa qualidade deve ter em conta as diferenças entre observadores, foi efetuado na última parte deste trabalho um estudo do impacto clínico da proposta de otimização da qualidade de imagem. A partir das imagens realizadas com o objeto simulador antropomórfico TOR MAM simulando uma mama pequena, seis médicos(as) radiologistas com mais de 5 anos de experiência em mamografia avaliaram as imagens “otimizadas” obtidas utilizando-se os parâmetros técnicos de exposição resultantes do estudo de otimização e a imagem resultante da escolha do sistema AOP. A análise estatística das avaliações feitas pelos médicos indica que a imagem “otimizada” da mama pequena apresenta uma melhor visualização das microcalcificações sem perda da qualidade da imagem na deteção de fibras e de massas em comparação com a imagem “standard”. Este trabalho permitiu introduzir uma nova definição da figura de mérito para o estudo de otimização da qualidade da imagem versus dose em mamografia. Permitiu também estabelecer uma metodologia consistente que pode facilmente ser aplicada a qualquer outro mamógrafo, contribuindo para a área da otimização em mamografia digital que é uma das áreas mais relevantes no que toca à proteção radiológica do paciente.
Resumo:
Optical networks are under constant evolution. The growing demand for dynamism require devices that can accommodate different types of traffic. Thus the study of transparent optical networks arises. This approach makes optical networks more "elegant" , due to a more efficient use of network resources. In this thesis, the author proposes devices that intend to form alternative approaches both in the state of art of these same technologies both in the fitting of this technologies in transparent optical networks. Given that full transparency is difficult to achieve with current technology (perhaps with more developed optical computing this is possible), the author proposes techniques with different levels of transparency. On the topic of performance of optical networks, the author proposes two techniques for monitoring chromatic dispersion with different levels of transparency. In Chapter 3 the proposed technique seems to make more sense for long-haul optical transmission links and high transmission rates, not only due to its moderate complexity but also to its potential moderate/high cost. However it is proposed to several modulation formats, particularly those that have a protruding clock component. In Chapter 4 the transparency level was not tested for various modulation formats, however some transparency is achieved by not adding any electrical device after the receiver (other than an analog-digital converter). This allows that this technique can operate at high transmission rates in excess of 100 Gbit / s, if electro-optical asynchronous sampling is used before the optical receiver. Thus a low cost and low bandwidth photo-detector can be used. In chapter 5 is demonstrated a technique for simultaneously monitoring multiple impairments of the optical network by generating novel performance analysis diagrams and by use of artificial neural networks. In chapter 6 the author demonstrates an all-optical technique for controlling the optical state of polarization and an example of how all-optical signal processing can fully cooperate with optical performance monitoring.
Resumo:
Phase and gain mismatches between the I and Q analog signal processing paths of a quadrature receiver are responsible for the generation of image signals which limit the dynamic range of a practical receiver. In this paper we analyse the effects these mismatches and propose a low-complexity blind adaptive algorithm to minimize this problem. The proposed solution is based on two, 2-tap adaptive filters, arranged in Adaptive Noise Canceller (ANC) set-up. The algorithm lends itself to efficient real-time implementation with minimal increase in modulator complexity.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial
Resumo:
This dissertation analyzes the possibilities of utilizing speech-processing technologies to transform the user experience of ActivoBank’s customers while using remote banking solutions. The technologies are examined through different criteria to determine if they support the bank’s goals and strategy and whether they should be incorporated in the bank’s offering. These criteria include the alignment with ActivoBank’s values, the suitability of the technology providers, the benefits these technologies entail, potential risks, appeal to the customers and impact on customer satisfaction. The analysis suggests that ActivoBank might not be in a position to adopt these technologies at this point in time.
Resumo:
Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.
Resumo:
Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.
Resumo:
The goal of this work was developing a query processing system using software agents. Open Agent Architecture framework is used for system development. The system supports queries in both Hindi and Malayalam; two prominent regional languages of India. Natural language processing techniques are used for meaning extraction from the plain query and information from database is given back to the user in his native language. The system architecture is designed in a structured way that it can be adapted to other regional languages of India. . This system can be effectively used in application areas like e-governance, agriculture, rural health, education, national resource planning, disaster management, information kiosks etc where people from all walks of life are involved.
Resumo:
International School of Photonics, Cochin University of Science and Technology
Resumo:
Interfacings of various subjects generate new field ofstudy and research that help in advancing human knowledge. One of the latest of such fields is Neurotechnology, which is an effective amalgamation of neuroscience, physics, biomedical engineering and computational methods. Neurotechnology provides a platform to interact physicist; neurologist and engineers to break methodology and terminology related barriers. Advancements in Computational capability, wider scope of applications in nonlinear dynamics and chaos in complex systems enhanced study of neurodynamics. However there is a need for an effective dialogue among physicists, neurologists and engineers. Application of computer based technology in the field of medicine through signal and image processing, creation of clinical databases for helping clinicians etc are widely acknowledged. Such synergic effects between widely separated disciplines may help in enhancing the effectiveness of existing diagnostic methods. One of the recent methods in this direction is analysis of electroencephalogram with the help of methods in nonlinear dynamics. This thesis is an effort to understand the functional aspects of human brain by studying electroencephalogram. The algorithms and other related methods developed in the present work can be interfaced with a digital EEG machine to unfold the information hidden in the signal. Ultimately this can be used as a diagnostic tool.