908 resultados para DRY STORAGE
Integration of an automatic storage and retrieval system (ASRS) in a discrete-part automation system
Resumo:
This technical report describes the work carried out in a project within the ERASMUS programme. The objective of this project was the Integration of an Automatic Warehouse in a Discrete-Part Automation System. The discrete-part automation system located at the LASCRI (Critical Systems) laboratory at ISEP was extended with automatic storage and retrieval of the manufacturing parts, through the integration of an automatic warehouse and an automatic guided vehicle (AGV).
Resumo:
O armazenamento de energia pode ser efetuado sobre cinco categorias, designadamente, elétrica, eletromecânica, mecânica, térmica e química. Contudo, o assunto aqui debatido é sobre meios de armazenamento de energia elétrica, sendo que o armazenamento de eletricidade é usualmente efetuado recorrendo a outros géneros de energia, tais como, química, mecânica, térmica ou, até, em energia potencial. [1]. Há nos dias de hoje uma crescente preocupação na forma como é gerido o setor elétrico, uma vez que este implica um elevado impacto ambiental. Neste sentido tem havido algumas alterações, nomeadamente, no que diz respeito à produção de energia elétrica. A utilização de energias renováveis estão cada vez mais presentes na produção de eletricidade (Figura 1), pois permitem diminuir de forma indireta a utilização dos combustíveis fósseis, sendo esta a principal vantagem face às centrais de produção convencionais.
Resumo:
The study analyzes the trend in frequency of adults who drive under the influence of alcohol in major Brazilian cities after the passing of laws, which prohibit drunk driving. Data from the Surveillance System for Risk and Protective Factors for Chronic Diseases by Telephone Survey (VIGITEL) between 2007 and 2013 were analyzed. The frequency of adults who drove after abusive alcohol consumption was reduced by 45.0% during this period (2.0% in 2007 to 1.1% in 2013). Between 2007 and 2008 (-0.5%) and between 2012 and 2013 (-0.5%), significant reductions were observed in the years immediately after the publication of these laws that prohibit drunk driving. These improvements towards the control of drunk driving show a change in the Brazilian population’s lifestyle.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, Perfil Gestão e Sistemas Ambientais
Impact of a price-maker pumped storage hydro unit on the integration of wind energy in power systems
Resumo:
The increasing integration of larger amounts of wind energy into power systems raises important operational issues, such as the balance between power generation and demand. The pumped storage hydro (PSH) units are one possible solution to mitigate this problem, once they can store the excess of energy in the periods of higher generation and lower demand. However, the behaviour of a PSH unit may differ considerably from the expected in terms of wind power integration when it operates in a liberalized electricity market under a price-maker context. In this regard, this paper models and computes the optimal PSH weekly scheduling in a price-taker and price-maker scenarios, either when the PSH unit operates in standalone and integrated in a portfolio of other generation assets. Results show that the price-maker standalone PSH will integrate less wind power in comparison with the price-taker situation. Moreover, when the PSH unit is integrated in a portfolio with a base load power plant, the role of the price elasticity of demand may completely change the operational profile of the PSH unit. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
The integration of large amounts of wind energy in power systems raises important operation issues such as the balance between power demand and generation. The pumped storage hydro (PSH) units are seen as one solution for this issue, avoiding the need for wind power curtailments. However, the behavior of a PSH unit might differ considerably when it operates in a liberalized market with some degree of market power. In this regard, a new approach for the optimal daily scheduling of a PSH unit in the day-ahead electricity market was developed and presented in this paper, in which the market power is modeled by a residual inverse demand function with a variable elasticity. The results obtained show that increasing degrees of market power of the PSH unit correspond to decreasing levels of storage and, therefore, the capacity to integrate wind power is considerably reduced under these circumstances.
Resumo:
A 70Co-30Ni dendritic alloy was produced on stainless steel by pulse electrodeposition in the cathodic domain, and oxidized by potential cycling. X-ray diffraction (XRD) identified the presence of two phases and scanning electron microscopy (SEM) evidenced an open 3D highly branched dendritic morphology. After potential cycling in 1 M KOH, SEM and X-ray photoelectron spectroscopy (XPS) revealed, respectively, the presence of thin nanoplates, composed of Co and Ni oxi-hydroxides and hydroxides over the original dendritic film. Cyclic voltammetry tests showd the presence of redox peaks assigned to the oxidation and reduction of Ni and Co centres in the surface film. Charge/discharge measurements revealed capacity values of 121 mAh g(1) at 1 mA cm(2). The capacity retention under 8000 cycles was above 70%, stating the good reversibility of these redox materials and its suitability to be used as charge storage electrodes. Electrochemical impedance spectroscopy (EIS) spectra, taken under different applied bias, showed that the capacitance increased when the electrode was fully oxidized and decreased when the electrode was reduced, reflecting different states-of-charge of the electrode. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
Electrochemically-reduced graphene oxide (Er-GO) and cobalt oxides (CoOx) were co-electrodeposited by cyclic voltammetry, from an electrolyte containing graphene oxide and cobalt nitrate, directly onto a stainless steel substrate to produce composite electrodes presenting high charge storage capacity. The electrochemical response of the composite films was optimized by studying the parameters applied during the electrodeposition process, namely the number of cycles, scan rate and ratio between GO/Co(NO3)(2) concentrations in the electrolyte. It is shown that, if the appropriate conditions are selected, it is possible to produced binder-free composite electrodes with improved electrochemical properties using a low-cost, facile and scalable technique. The optimized Er-GO/CoOx developed in this work exhibits a specific capacitance of 608 F g(-1) at a current density of 1 A g(-1) and increased reversibility when compared to single CoOx. (C) 2015 Elsevier B.V. All rights reserved.
Resumo:
Accumulation of microcystin-LR (MC-LR) in edible aquatic organisms, particularly in bivalves, is widely documented. In this study, the effects of food storage and processing conditions on the free MC-LR concentration in clams (Corbicula fluminea) fed MC-LR-producing Microcystisaeruginosa (1 × 105 cell/mL) for four days, and the bioaccessibility of MC-LR after in vitro proteolytic digestion were investigated. The concentration of free MC-LR in clams decreased sequentially over the time with unrefrigerated and refrigerated storage and increased with freezing storage. Overall, cooking for short periods of time resulted in a significantly higher concentration (P < 0.05) of free MC-LR in clams, specifically microwave (MW) radiation treatment for 0.5 (57.5%) and 1 min (59%) and boiling treatment for 5 (163.4%) and 15 min (213.4%). The bioaccessibility of MC-LR after proteolytic digestion was reduced to 83%, potentially because of MC-LR degradation by pancreatic enzymes. Our results suggest that risk assessment based on direct comparison between MC-LR concentrations determined in raw food products and the tolerable daily intake (TDI) value set for the MC-LR might not be representative of true human exposure.
Resumo:
The most preferred containers by Aedes aegypti were studied April and July (rainy and dry periods) in two Manaus neighbourhoods. In all, 2,700 premises and 13,912 containers were examined, most (87%) recorded outdoors. Out of the 13,100 inspected premises, only 1.6% showed to be positive for Aedes aegypti, summing up to 7,916 collected samples. Most frequently found containers outdoors in either neighbourhood regardless of rain or dry period were Bottles flasks and Storage, and indoors, Fixed, Flowerpots, and buckets. Productivity was estimated according to the number of premises and positive containers investigated, showing the actual container groups productivity. Considering both rainy and dry periods outdoors at Praça 14 the groups of Tyre, Flask, Bottle, Construction Equipment and Fixed, had the highest averages respectively. Construction Equipment and Flask groups were the most productive in Coroado in April. Flask, Construction Equipment and Storage groups stood out in July.
Resumo:
In-network storage of data in wireless sensor networks contributes to reduce the communications inside the network and to favor data aggregation. In this paper, we consider the use of n out of m codes and data dispersal in combination to in-network storage. In particular, we provide an abstract model of in-network storage to show how n out of m codes can be used, and we discuss how this can be achieved in five cases of study. We also define a model aimed at evaluating the probability of correct data encoding and decoding, we exploit this model and simulations to show how, in the cases of study, the parameters of the n out of m codes and the network should be configured in order to achieve correct data coding and decoding with high probability.
Resumo:
Demo in Workshop on ns-3 (WNS3 2015). 13 to 14, May, 2015. Castelldefels, Spain.
Resumo:
A cidade do Porto é uma das regiões do país onde é importante uma gestão sustentável e integrada dos recursos hídricos. A (re) utilização de água surge neste contexto como uma possível resposta na sua utilização como um recurso hídrico passível de ser usado beneficamente, permitindo a poupança de fontes de água convencionais e aumentando a disponibilidade dos recursos hídricos existentes para finalidades que requerem padrões de qualidade mais exigentes. O potencial desta prática no nosso país é enorme, considerando que o volume de água tratada descarregada no ano 2000 era suficiente para suprir 10% das necessidades em água para rega num ano seco, sem necessidade de armazenamento sazonal. Por outro lado, um sistema de rega, quando devidamente projetado e funcionando adequadamente, permite que a água seja aplicada com um caudal, duração e frequência que maximizam o consumo da água e nutrientes pela planta. Este projeto consiste no desenvolvimento de um Sistema de Gestão Técnica para o controlo do sistema de rega dos jardins do ISEP – Instituto Politécnico de Engenharia do Porto com recurso a um autómato programável (PLC). Pretende-se otimizar os consumos energéticos do sistema de rega tendo em conta os parâmetros de humidade, temperatura e velocidade do vento característicos do local a regar. Outros dos objetivos é controlar o processo de enchimento e de rega. Esta operação consiste no controlo das bombas e respetivos débitos e conhecimento dos caudais necessários. Pretende-se, igualmente, definir e colocar em marcha todo o equipamento necessário para a realização do projeto. Os dados coletados devem ser tratados de tal modo que possam ser realizadas análises diárias, mensais e/ou anuais. Neste trabalho foram efetuados os cálculos de dimensionamentos relativamente às necessidades hídricas da planta e necessidades de rega, entre outros.
Resumo:
A cidade do Porto é uma das regiões do país onde é importante uma gestão sustentável e integrada dos recursos hídricos. A (re) utilização de água surge neste contexto como uma possível resposta na sua utilização como um recurso hídrico passível de ser usado beneficamente, permitindo a poupança de fontes de água convencionais e aumentando a disponibilidade dos recursos hídricos existentes para finalidades que requerem padrões de qualidade mais exigentes. O potencial desta prática no nosso país é enorme, considerando que o volume de água tratada descarregada no ano 2000 era suficiente para suprir 10% das necessidades em água para rega num ano seco, sem necessidade de armazenamento sazonal. Por outro lado, um sistema de rega, quando devidamente projetado e funcionando adequadamente, permite que a água seja aplicada com um caudal, duração e frequência que maximizam o consumo da água e nutrientes pela planta. Este projeto consiste no desenvolvimento de um Sistema de Gestão Técnica para o controlo do sistema de rega dos jardins do ISEP – Instituto Politécnico de Engenharia do Porto com recurso a um autómato programável (PLC). Pretende-se otimizar os consumos energéticos do sistema de rega tendo em conta os parâmetros de humidade, temperatura e velocidade do vento característicos do local a regar. Outros dos objetivos é controlar o processo de enchimento e de rega. Esta operação consiste no controlo das bombas e respetivos débitos e conhecimento dos caudais necessários. Pretende-se, igualmente, definir e colocar em marcha todo o equipamento necessário para a realização do projeto. Os dados coletados devem ser tratados de tal modo que possam ser realizadas análises diárias, mensais e/ou anuais. Neste trabalho foram efetuados os cálculos de dimensionamentos relativamente às necessidades hídricas da planta e necessidades de rega, entre outros.
Resumo:
The integration of wind power in eletricity generation brings new challenges to unit commitment due to the random nature of wind speed. For this particular optimisation problem, wind uncertainty has been handled in practice by means of conservative stochastic scenario-based optimisation models, or through additional operating reserve settings. However, generation companies may have different attitudes towards operating costs, load curtailment, or waste of wind energy, when considering the risk caused by wind power variability. Therefore, alternative and possibly more adequate approaches should be explored. This work is divided in two main parts. Firstly we survey the main formulations presented in the literature for the integration of wind power in the unit commitment problem (UCP) and present an alternative model for the wind-thermal unit commitment. We make use of the utility theory concepts to develop a multi-criteria stochastic model. The objectives considered are the minimisation of costs, load curtailment and waste of wind energy. Those are represented by individual utility functions and aggregated in a single additive utility function. This last function is adequately linearised leading to a mixed-integer linear program (MILP) model that can be tackled by general-purpose solvers in order to find the most preferred solution. In the second part we discuss the integration of pumped-storage hydro (PSH) units in the UCP with large wind penetration. Those units can provide extra flexibility by using wind energy to pump and store water in the form of potential energy that can be generated after during peak load periods. PSH units are added to the first model, yielding a MILP model with wind-hydro-thermal coordination. Results showed that the proposed methodology is able to reflect the risk profiles of decision makers for both models. By including PSH units, the results are significantly improved.