991 resultados para Crowns (Dentistry)
Resumo:
Objective Bacterial species have been found harboring the internal surface of dental implants as consequence of their failed connections. The aim of the present study was to compare the detection frequency of bacterial leakage from human saliva through the implantabutment interface, under non-loading conditions, using either DNA Checkerboard or culture method. Materials and methods Thirty dental implants with hexagonal platforms were connected to pre-machined abutments according to the manufacturers specifications. The assemblies were individually incubated in human saliva under anaerobic conditions for 7 similar to days at 37 degrees C. Afterward, contents from the inner parts of the implants were collected and evaluated with either DNA Checkerboard (s similar to=similar to 15) or culture (n similar to=similar to 15). Subsequently, identification and quantitation of bacterial species from saliva and implants were carried out for the group evaluated with the DNA Checkerboard method. Results Both DNA Checkerboard and culture showed positive signals of bacterial leakage in 6 of the 15 evaluated samples. Capnocytophaga gingivalis and Streptococcus mutans were the most frequently detected species harboring the internal surface of the implants followed by Veillonella parvula. Conclusion Occurrence of bacterial leakage along the implantabutment interface is comparably detected with both DNA Checkerboard hybridization and conventional culture methods.
Resumo:
Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05). Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)
Resumo:
Objectives: The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. Material and methods: Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: ( 1) abutments without hexagon at the base and ( 2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. Results: Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that ( 1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, ( 2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and ( 3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws.
Resumo:
The purpose of this study was to warn the dental community about a possible problem in function with partial implant-supported prostheses used for long periods. The misalignment between natural teeth and the implant-supported prosthesis on teeth 11 and 12, observed in a 14-year clinical follow-up, illustrates the fact. The metal-ceramic crowns were placed in 1995 after a rigorous occlusal adjustment. Evaluations were made at 4, 6, 9, and 14 years, when it was noticed that the restorations were positioned palatally and extruded in comparison with the natural teeth. After 9 years, a greater discrepancy was noticed, with anterior occlusion and esthetic changes. The possible causes have been discussed: occlusal problems, parafunctional habits, and natural movement. The first 2 options were discarded after clinical analysis and diagnosis. Therefore, the natural movement probably deriving from an interaction of mechanical and genetic factors might have been the cause. The implants do not have periodontal ligaments but rather ankylosis, so they do not suffer those movements. This case emphasizes the need to inform patients that implants can last more than 10 years in function, but this is not the case with restorations, which lose function and esthetics and must be replaced.
Resumo:
Purpose: To evaluate whether Nd:YAG laser irradiation of etched and unetched dentin through an uncured adhesive affected the microtensile bond strength (pTBS). Materials and Methods: Flat dentin surfaces were created in 19 extracted human third molars. Adper Single Bond (SB) adhesive was applied over etched (groups 1 to 3) or unetched dentin (groups 4 to 6). The dentin was then irradiated with a Nd:YAG laser through the uncured adhesive, using 0.75 or 1 W power settings, except for the control groups (groups 1 and 4). The adhesive was light cured and composite crowns were built up. After 24 h, the teeth were sectioned into beams, with cross-sectional areas of 0.49 mm(2), and were stressed under tension. Data were statistically analyzed using two-way ANOVA and Tukey's test (alpha = 5%). Dentin surfaces of fractured specimens and the interfaces of untested beams were observed under scanning electron microscopy (SEM). Results: Acid etching, laser irradiation, and their interaction significantly affected bonding (p < 0.05). Laser irradiation did not improve bonding of etched dentin to resin (p > 0.05). However, higher pTBS means were found on unetched lased dentin (groups 5 and 6), but only in comparison to group 4, where neither lasing nor etching was performed. Groups 4 to 6 showed the lowest pTBS means among all groups tested (p < 0.05). Laser irradiation did not change the characteristics of the hybrid layers created, while solidification globules were observed on lased dentin surfaces under SEM. Conclusion: Laser irradiation of dentin through the uncured adhesive did not significantly improve the pTBS in comparison to the suggested manufacturer's technique.
Resumo:
The aim of this article is to present the pediatric dentistry and orthodontic treatment protocol of rehabilitation of cleft lip and palate patients performed at the Hospital for Rehabilitation of Craniofacial Anomalies - University of So Paulo (HRAC-USP). Pediatric dentistry provides oral health information and should be able to follow the child with cleft lip and palate since the first months of life until establishment of the mixed dentition, craniofacial growth and dentition development. Orthodontic intervention starts in the mixed dentition, at 8-9 years of age, for preparing the maxillary arch for secondary bone graft procedure (SBGP). At this stage, rapid maxillary expansion is performed and a fixed palatal retainer is delivered before SBGP. When the permanent dentition is completed, comprehensive orthodontic treatment is initiated aiming tooth alignment and space closure. Maxillary permanent canines are commonly moved mesially in order to substitute absent maxillary lateral incisors. Patients with complete cleft lip and palate and poor midface growth will require orthognatic surgery for reaching adequate anteroposterior interarch relationship and good facial esthetics.
Resumo:
Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.
Resumo:
Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)
Resumo:
Objective. To test the hypothesis that the difference in the coefficient of thermal contraction of the veneering porcelain above (˛liquid) and below (˛solid) its Tg plays an important role in stress development during a fast cooling protocol of Y-TZP crowns. Methods. Three-dimensional finite element models of veneered Y-TZP crowns were developed. Heat transfer analyses were conducted with two cooling protocols: slow (group A) and fast (groups B–F). Calculated temperatures as a function of time were used to determine the thermal stresses. Porcelain ˛solid was kept constant while its ˛liquid was varied, creating different ˛/˛solid conditions: 0, 1, 1.5, 2 and 3 (groups B–F, respectively). Maximum ( 1) and minimum ( 3) residual principal stress distributions in the porcelain layer were compared. Results. For the slowly cooled crown, positive 1 were observed in the porcelain, orientated perpendicular to the core–veneer interface (“radial” orientation). Simultaneously, negative 3 were observed within the porcelain, mostly in a hoop orientation (“hoop–arch”). For rapidly cooled crowns, stress patterns varied depending on ˛/˛solid ratios. For groups B and C, the patterns were similar to those found in group A for 1 (“radial”) and 3 (“hoop–arch”). For groups D–F, stress distribution changed significantly, with 1 forming a “hoop-arch” pattern while 3 developed a “radial” pattern. Significance. Hoop tensile stresses generated in the veneering layer during fast cooling protocols due to porcelain high ˛/˛solid ratio will facilitate flaw propagation from the surface toward the core, which negatively affects the potential clinical longevity of a crown.
Resumo:
OBJECTIVES: The aim of this study was to investigate the internal fit (IF) of glass-infiltrated alumina (ICA - In-Ceram Alumina), yttria-stabilized tetragonal zirconia polycrystals (Y-TZP - IPS e.max ZirCAD), and metal-ceramic (MC - Ni-Cr alloy) crowns. MATERIAL AND METHODS: Sixty standardized resin-tooth replicas of a maxillary first molar were produced for crown placement and divided into 3 groups (n=20 each) according to the core material used (metal, ICA or Y-TZP). The IF of the crowns was measured using the replica technique, which employs a light body polyvinyl siloxane impression material to simulate the cement layer thickness. The data were analyzed according to the surfaces obtained for the occlusal space (OS), axial space (AS) and total mean (TM) using two-way ANOVA with Tukey s multiple comparison test (p<0.05). RESULTS: No differences among the different areas were detected in the MC group. For the Y-TZP and ICA groups, AS was statistically lower than both OS and TM. No differences in AS were observed among the groups. However, OS and TM showed significantly higher values for ICA and Y-TZP groups than MC group. Comparisons of ICA and Y-TZP revealed that OS was significantly lower for Y-TZP group, whereas no differences were observed for TM. CONCLUSIONS: The total mean achieved by all groups was within the range of clinical acceptability. However, the metal-ceramic group demonstrated significantly lower values than the all-ceramic groups, especially in OS.
Resumo:
The above factors emphasize the scope of this thesis for further investigations on zirconia, the improvement of all-ceramic zirconia restorations, and especially the interaction of zirconia and veneering and its influence on the performance of the whole restoration. The introduction, chapter 1, gave a literature overview on zirconia ceramics. In chapter 2, the objective of the study was to evaluate the effect of abrading before and after sintering using alumina-based abrasives on the surface of yttria-tetragonal zirconia polycrystals. Particular attention was paid to the amount of surface stress–assisted phase transformation (tetragonal→monoclinic) and the presence of microcracks. Chapter 3 is based on the idea that the conventional sintering techniques for zirconia based materials, which are commonly used in dental reconstruction, may not provide a uniform heating, with consequent generation of microstructural flaws in the final component. As a consequence of the sintering system, using microwave heating, may represent a viable alternative. The purpose of the study was to compare the dimensional variations and physical and microstructural characteristics of commercial zirconia (Y-TZP), used as a dental restoration material, sintered in conventional and microwave furnaces. Chapter 4 described the effect of sandblasting before and after sintering on the surface roughness of zirconia and the microtensile bond strength of a pressable veneering ceramic to zirconia.
Resumo:
Chromosomal and genetic syndromes are frequently associated with dental and cranio-facial alterations. The aim of our study is to identify and describe the dental and craniofacial alterations typical of six genetic and chromosomal syndromes examined. Materials and Methods- A dental visit was performed to 195 patients referred from Sant’Orsola Hospital of Bologna, University of Bologna, to Service of Special Need Dentistry, Dental Clinic, Department of Biomedical and Neuromotor Science, University of Bologna. The patients recruited were 137 females and 58 males, in an age range of 3-49 years (mean age of 13.8±7.4). The total sample consisted of subjects affected with Down Syndrome (n=133), Familiar Hypophosphatemic Ricket (n=10), Muscular Dystrophies (n=12), Noonan Syndrome (n=13), Turner Syndrome (n=17), Williams Syndrome(n=10). A questionnaire regarding detailed medical and dental history, oral health and dietary habits, was filled by parents/caregivers, or patients themselves when possible. The intra-oral and extra-oral examination valued the presence of facial asymmetries, oral habits, dental and skeletal malocclusions, dental formula, dental anomalies, Plaque Index (Silness&LÖe Index), caries prevalence (dmft/DMFT index), gingivitis and periodontal disease, and mucosal lesions. Radiographic examinations (Intraoral radiographies, Orthopanoramic, Skull teleradiography) were executed according to patient’s age and treatment planning. A review of literature about each syndrome and its dental and cranio-facial characteristics and about caries, hygiene status and malocclusion prevalence on syndromic and non-syndromic population was performed. Results - The data of all the patients were collected in the “Data Collection Tables” created for each syndrome. General anamnesis information, oral hygiene habits and dmft/DMFT, PI, malocclusion prevalence were calculated and compared to syndromic and non-syndromic population results found in literature. Discussions and conclusions - Guidelines of Special Care dentistry were indicated for each syndrome, in relation to each syndrome features and individual patient characteristics.
Resumo:
Objectives: To assess the biological and technical complication rates of single crowns on vital teeth (SC-V), endodontically treated teeth without post and core (SC-E), with a cast post and core (SC-PC) and on implants (SC-I). Material and methods: From 392 patients with chronic periodontitis treated and documented by graduate students during the period from 1978 to 2002, 199 were reexamined during 2005 for this retrospective cohort study, and 64 of these patients were treated with SCs. Statistical analysis included Kaplan–Meier survival functions and event rates per 100 years of object-time. Poisson regression was used to compare the four groups of crowns with respect to the incidence rate ratio of failures, and failures and complications combined over 10 years and the entire observation period. Results: Forty-one (64%) female and 23 (36%) male patients participated in the reexamination. At the time of seating the crowns, the mean patient age was 46.8 (range 24–66.3) years. One hundred and sixty-eight single unit crowns were incorporated. Their mean follow-up time was 11.8 (range 0.8–26.4) years. During the time of observation, 22 biological and 11 technical complications occurred; 19 SC were lost. The chance for SC-V (56) to remain free of any failure or complication was 89.3% (95% confidence interval [CI] 76.1–95.4) after 10 years, 85.8% (95% CI 66–94.5) for SC-E (34), 75.9% for SC-PC (39), (95% CI 58.8–86.7) and 66.2% (95% CI 45.1–80.7) for SC-I (39). Over 10 years, 95% of SC-I remained free of failure and demonstrated a cumulative incidence of failure or complication of 34%. Compared with SC-E, SC-I were 3.5 times more likely to yield failures or complications and SC-PC failed 1.7 times more frequently than did SC-E. SC-V had the lowest rate of failures or complications over the 10 years. Conclusions: While SCs on vital teeth have the best prognosis, those on endodontically treated teeth have a slightly poorer prognosis over 10 years. Crowns on teeth with post and cores and implant-supported SCs displayed the highest incidence of failures and complications.
Resumo:
Early implant placement is one of the treatment options after tooth extraction. Implant surgery is performed after a healing period of 4 to 8 weeks and combined with a simultaneous contour augmentation using the guided bone regeneration technique to rebuild stable esthetic facial hard- and soft-tissue contours.
Resumo:
In dentistry the restoration of decayed teeth is challenging and makes great demands on both the dentist and the materials. Hence, fiber-reinforced posts have been introduced. The effects of different variables on the ultimate load on teeth restored using fiber-reinforced posts is controversial, maybe because the results are mostly based on non-standardized in vitro tests and, therefore, give inhomogeneous results. This study combines the advantages of in vitro tests and finite element analysis (FEA) to clarify the effects of ferrule height, post length and cementation technique used for restoration. Sixty-four single rooted premolars were decoronated (ferrule height 1 or 2 mm), endodontically treated and restored using fiber posts (length 2 or 7 mm), composite fillings and metal crowns (resin bonded or cemented). After thermocycling and chewing simulation the samples were loaded until fracture, recording first damage events. Using UNIANOVA to analyze recorded fracture loads, ferrule height and cementation technique were found to be significant, i.e. increased ferrule height and resin bonding of the crown resulted in higher fracture loads. Post length had no significant effect. All conventionally cemented crowns with a 1-mm ferrule height failed during artificial ageing, in contrast to resin-bonded crowns (75% survival rate). FEA confirmed these results and provided information about stress and force distribution within the restoration. Based on the findings of in vitro tests and computations we concluded that crowns, especially those with a small ferrule height, should be resin bonded. Finally, centrally positioned fiber-reinforced posts did not contribute to load transfer as long as the bond between the tooth and composite core was intact.