333 resultados para Cromo hexavalente
Resumo:
The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology
Resumo:
The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O presente trabalho avaliou a influência da suplementação com cromo em algumas variáveis sanguíneas em 11 equinos machos, adultos, usados em atividade de policiamento. Cada animal recebeu 11mg de cromo/400kg de peso corpóreo, via oral, durante 30 dias. Nos dias 0 (antes) e 30 (após), os animais foram avaliados e amostras de sangue foram obtidas antes e após o exercício. Glicose e lactato plasmáticos e cortisol e insulina séricas foram determinados. No dia 0, as concentrações de glicose plasmática foram 68,4±5,6mg/dL e 78,7±6,5mg/dL; de lactato plasmático, 6,2±0,6mg/dL e 13,1±7,6mg/dL; de cortisol sérico, 48,5±7,9ng/mL e 42,6±19,7ng/mL; e de insulina sérica, 3,0±6,4µUI/m L e 1,9±1,7µUI/mL, respectivamente, antes e após o exercício. No dia 30, as concentrações de glicose plasmática foram 73,3±5,7mg/dL e 78,4±6,7mg/dL; de lactato plasmático, 7,3±0,9mg/dL e 7,6±1,2mg/dL; de cortisol sérico, 62,9±21,8ng/mL e 40,3±17,0ng/mL; e de insulina sérica, 1,4±1,3µUI/mL e 1,7±1,4µUI/mL, respectivamente, antes e após o exercício. Como efeito do exercício, foi demonstrado redução na concentração sérica de insulina e aumento no lactato e glicose plasmáticas. A suplementação com cromo resulto u em redução dos valores de lactato após a atividade física, possivelmente indicando que o cromo contribuiu para a melhor utilização da glicose plasmática e melhor adaptação ao exercício físico realizado.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objetivou-se com este estudo determinar os coeficientes de digestibilidade aparente (CDA) da proteína bruta e dos aminoácidos de duas espécies de macrófitas aquáticas flutuantes (Eichhornia crassipes e Pistia stratiotes) pela tilápia-do-nilo (Oreochromis niloticus) e verificar a qualidade da água dos aquários de digestibilidade em relação às concentrações de nitrogênio e fósforo. Foram elaboradas três rações, marcadas com 0,10% de óxido de cromo-III, sendo uma ração-referência (purificada) e as demais contendo 30% de cada uma das macrófitas aquáticas. As tilápias-do-nilo (58,8 + 18,5 g) foram alimentadas até a saciedade aparente e a coleta de fezes foi feita pelo sistema Guelph modificado. Os CDA médios da proteína e dos aminoácidos foram, respectivamente, 93,17 e 93,32% para a ração-referência; 59,23 e 60,35% para E. crassipes; e 52,24 e 57,40% para P. stratiotes. Não foram constatadas diferenças significativas entre os valores de CDA da proteína e dos aminoácidos dos ingredientes vegetais. Os resultados obtidos demonstraram reduzida eficiência da tilápia-do-nilo em assimilar a maioria dos aminoácidos de E. crassipes e P. stratiotes. As excretas das tilápias-do-nilo contribuíram para o aumento das concentrações de nitrogênio e fósforo na água dos aquários, independentemente da ração fornecida.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The Thermal Corridor of Uruguay River is located in the triple border of Argentine, Brazil and Uruguay, and shows an intense economic thermal tourism activity, mainly based on groundwaters from Guarani Aquifer System (GAS). Recent studies have pointed out the occurrence of high concentrations of arsenic (>10 μg/L) in GAS groundwater in this area. The complex geological and hydrogeological framework in the area is associated to the Paraná Basin geological evolution south of the Assuncion-Rio Grande Arch; it encompass paleozoic marine sequences and continental sequences permian/eotriassic to mesozoic in age, which are covered by basaltic lavas of Serra Geral Formation. Iron oxide coatings have been described in sandstones of Buena Vista and Sanga do Cabral formations, which underlie GAS units. Arsenic occurrence is associated to sodium bicarbonate groundwater with pH values over 8.0. Arsenic is released to groundwater by desorption from iron oxides/hydroxides, as result of the higher pH of these waters, indicating that arsenic is released from the units that underlie GAS units. Increase in chromium and uranium concentrations are also related to high pH groundwaters, thus indicating special care on using groundwater from this region.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Caracterização química da farinha de vísceras de avestruz e seu valor nutritivo para tilápia-do-Nilo
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)