974 resultados para Control-flow Analysis


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A on-line thermostatization system that use simples materials, for flow injection and continuous flow analysis is described. The proposed system showed good performance between 10 to 40ºC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this report is to classify analytical methods based on flowing media and to define (standardize) terminology. After the classification and a discussion of terms describing the systems and component parts, a section is devoted to terms describing the performance of flow systems. The list of terms included is restricted to the most relevant ones; especially "self-explanatory" terms are left out. It is emphasised that the usage of terms or expressions that do not adequately describe the processes or procedures involved should be strongly discouraged. Although belonging to the category of methods based on flowing media, chromatographic methods are not comprised in the present document. However, care has been taken that the present text is not in conflict with definitions in that domain. In documents in which flow methods are described, it should be clearly indicated how the sample and/or reagent is introduced and how the sample zone is transported. When introducing new techniques in the field, or variants of existing techniques, it is strongly recommended that descriptive terms rather than trivial or elaborate names are used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple and low cost flow cell is proposed for measurements by solid-phase spectrophotometry employing a conventional spectrophotometer. The flow cell geometry allows the employment of a large amount of the solid support without causing both excessive attenuation of the radiation beam and increasing of the back-pressure. The adaptation of the flow cell in the optical path of the spectrophotometer in order to increase the precision is discussed. The flow cell characteristics were demonstrated by measurements of Co(II), employing 1-(2-tiazolylazo)-2-naphthol (TAN) immobilized on C18 bonded silica as solid support. The apparent molar absorptivity and coefficient of variation were estimated as 1.86 x 10(5) L mol-1 cm-1 and 1.4 % (n=15). A sample throughput of 40 determinations per hour and a detection limit of 15 mug L-1 (99.7 % confidence level) were achieved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A spectrophotometric flow injection analysis (FIA) procedure employing natural urease enzyme source for the determination of urea in animal blood plasma was developed. Among leguminous plants used in the Brazilian agriculture, the Cajanus cajan specie was selected as urease source considering its efficiency and availability. A minicolumn was filled with leguminous fragments and coupled to the FIA manifold, where urea was on-line converted to ammonium ions and subsequently it was quantified by spectrophotometry. The system was employed to determine urea in animal plasma samples without any prior treatment. Accuracy was assessed by comparison results with those obtained employing the official procedure and no significant difference at 90 % confidence level was observed. Other profitable features such as an analytical throughput of 30 determinations per hour, a reagent consumption of 19.2 mg sodium salicylate, 0.5 mg sodium hipochloride and a relative standard deviation of 1.4 % (n= 12) were also obtained.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A low cost spectrophotometric cell for use in flow analysis was manufactured in acrylic and adapted to a commercial spectrophotometer. The application of this cell was performed in the determination of chromium (VI) in steel samples using the reaction with the alkaloid brucine in presence of oxalic acid and 0.6 mol L-1 sulfuric acid. The cell allows an enlarged analytical range, diminishing the extension of dilutions, which is useful for on-line monitoring of industrial processes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An important component for the automation of flow injection analysis (FIA) systems is the sample injection valve. A simple and inexpensive commutator with 16 pinch valves (8 normally open and 8 closed) was developed and configured as a multichannel injection valve. It is activated by a single solenoid of 3 Kgf, powered by a pulsed driver circuit, controlled by a microcomputer or a switch. FIA with spectrophometric detection of potassium dichromate solution was used for the evaluation of the new injection valve and its comparison with other valves, for sample loops of 50, 100, 200, 300 and 500 muL. The repeatability was favorable (RSD 1.0% for 15 injections at each loop volume) compared to a manual injector, an electropneumatic injector and an injector configured with three mini solenoid valves (RSD 1.1, 1.3 and 1.0%, respectively, for15 injections at each loop volume).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquarium air pumps are proposed and evaluated as pneumatic liquid propulsion devices for flow injection and continuos flow analysis (FIA and CFA) systems. This kind of pump is widely available at a very low cost and it can sustain a pressure around of 4 psi (0.28 bar) indefinitely. By applying this air pressure onto a solution contained in a reservoir flask, it is possible to reach flow rates of up to 12.5 mL min-1 for circuits comprising reactors, made from 0.8 i.d. tubing with a length of 100 cm. The precise adjustment of flow rate below the maximum one can be made with a simplified needle valve or inserting in series a short length of capillary tube. The absence of flow pulsation is a definite advantage in comparison with peristaltic pumps, especially when amperometric detection is elected, as confirmed experimentally in FIA and CF applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple and low cost device (ca. US$ 150) that comprises two photodiodes fixed in lab-made Perspex flow cell is proposed for chemiluminescence measurements. The characteristics of the device (large observation window and reduced thickness) allow maximizing the amount of the emitted radiation detected. A sensitivity improvement of ca. 50 % was observed by employing two photodiodes for signal measurements. The performance of the device was assessed by the oxidation of luminol by hydrogen peroxide, yielding a linear response within the range of 2.50 to 500 µmol L-1 H2O2. The detection limit was estimated as 0.8 µmol L-1 hydrogen peroxide which is comparable with those obtained by using equipments based on photomultipliers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää Transpoint Cargon kuljetussuunnittelun nykytila ja kuljetussuunnittelijoiden välisten vastuiden jakaantuminen. Työn tavoitteena oli lisäksi rakentaa kuljetussuunnittelulle alueellinen toimintamalli yrityksen asettamien rajoitteiden mukaisesti. Kuljetussuunnittelun tilaa tutkittiin haastatteluiden, visuaalisen analysoinnin, oman työkokemuksen ja tuotevirta-analyysin avulla. Kuljetussuunnittelun suurimmat kehitystarpeet löytyivät vastuiden loogisemmasta jakamisesta ja suunnittelijoiden tavasta ohjata autoja. Kehitysehdotuksena nykytilanteen parantamiseksi työssä esitetään kuljetussuunnittelijoiden työtehtävien jakaminen klusteri mallin mukaisesti. Klusteri malliin perustuen työssä esitetään kolme eri vaihtoehtoa kuljetussuunnittelun alueellisen toimintamallin toteuttamiseksi.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work a micro-heater device to be used as an integral part of the flow analysis manifold is described. The usefulness of the device was demonstrated using it in the development of a multicommutated flow analysis procedure for the spectrophotometric determination of manganese in plant digest. The method was based on the manganese oxidation by periodate in phosphoric acid medium to form the permanganate anion. The reaction development is dependent on the temperature and it was observed that at 25 °C a time interval of ca. 15 min was necessary for the reaction to attain equilibrium. Setting the temperature to 70 ºC, this time interval could be decreased to ca. 30 s. This condition was easily attained employing the proposed micro-heater device coupled to the manifold. The procedure was applied to manganese determination in soybean digests and results compared with those obtained by inductively coupled argon plasma optical emission spectrometry (ICP-OES). No significant difference at 90% confidence level was observed. A linear response for sample concentrations ranging from 5.0 to 30.00 mg L-1 Mn2+; a relative standard deviation of 1.3% (n = 6) for a typical sample containing 6.3 mg L-1 Mn2+; a sampling rate of 22 determinations per hour; a low reagent consumption, of 12.0 mg NaIO4 per determination; and a detection limit of 1.2 mg L-1 were achieved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A digital multimeter (~U$ 240.00 on the national market) connected to a microcomputer by a RS-232 serial interface is proposed for data acquisition in equipment with analog output. Data are measured at the rate of 2 points per second and stored in text files by the software that accompanies the device, running in a Windows environment. The performance of the multimeter was verified by monitoring the transient signals generated in flow injection systems associated with fluorimetric, spectrophotometric and flame photometric detection. In addition, the performance of the proposed device was similar to that attained by employing an interface card with a 12-bit analog-to-digital converter for acquisition of the signals generated by a capillary electrophoresis equipment with oscillometric detection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An experiment is proposed to introduce some fundamentals of flow analysis, chemiluminescence and kinetic monitoring of enzymatic reactions in undergraduate courses. Chemiluminescence detection is performed with a simple spectrophotometer equipped with a lab-made spiral flow cell constructed from a polyethylene tube. The hydrogen peroxide produced by the glucose oxidation in the presence of glucose oxidase is continuously monitored by the reaction with luminol in alkaline media in a flow injection system. The exercise allows also the discussion of important analytical features and the comparison with different optical methods of analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Spectrophotometry is one of the most widespread analytical techniques due to its simplicity, reliability, and low-cost instrumentation for both direct measurements and coupled to other techniques or processes such as chromatography, electrophoresis and flow analysis. However, the application is often limited by sensitivity. This article describes some advances that greatly improve the performance of spectrophotometric measurements, especially in order to increase sensitivity, including the employment of liquid-core waveguides and solid-phase spectrophotometry.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Essential aspects for characterization of a flow-based analytical procedure or system are discussed in order to permit the composition of a checklist that will lead to a protocol for reporting results and systems in flow analysis. Aspects more related to chromatographic procedures are not considered. The intent is to present normalized proposals in the field of flow analysis for practitioners and developers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The behaviour of Nafion® polymeric membranes containing acid-base dyes, bromothymol blue (BB) and methyl violet (MV), were studied aiming at constructing an optical sensor for pH measurement. BB revealed to be inadequate for developing sensing phases due to the electrostatic repulsion between negative groups of their molecules and the negative charge of the sulfonate group of the Nafion®, which causes leaching of the dye from the membrane. On the other hand, MV showed to be suitable due to the presence of positive groups in its structure. The membrane prepared from a methanolic solution whose Nafion®/dye molar ratio was 20 presented the best analytical properties, changing its color from green to violet in the pH range from 0.6 to 3.0. The membrane can be prepared with good reproducibility, presenting durability of ca. 6 months and response time of 22 s, making possible its use for pH determination in flow analysis systems.