1000 resultados para Contabilidade Analítica
Resumo:
The development of liquid chromatography-mass spectrometric (LC-MS) techniques in the last few decades has made possible the analysis of trace amounts of analytes from complex matrices. With LC, the analytes of interest can be separated from each other as well as from the interfering matrix, after which they can be reliably identified thanks to the sensitivity and specificity of MS. LC-MS has become an irreplaceable tool for many applications, ranging from the analysis of proteins or pharmaceuticals in biological fluids to the analysis of toxic substances in environmental samples. In different segments of Brazilian Industry mass spectrometry has an important role, e.g. in the pharmaceutical industry in the development of generic formulations, contributing to the growth of Industry and social inclusion. However, the Brazilian chemists until this moment don't have an effective role in this new segment of the analytical chemistry in Brazil. The present paper shows the actual scenario for mass spectrometry in the pharmaceutical industry, emphasizing the need of a revision of graduation courses to attend the needs of this growing market.
Resumo:
The results of a survey of institutions offering undergraduate studies, with the objective of evaluating the importance of Qualitative Analytical Chemistry for Chemistry courses in Brazil, are presented and discussed. Judging by the data, the content of the course of Qualitative Analytical Chemistry is considered by the Brazilian institutions offering undergraduate studies to be a body of knowledge essential for the formation of the chemist. This aspect is deemed valid for both baccalaureate and teaching license studies.
Resumo:
The first two papers in this series described the basic theory involved in supercritical fluid chromatography (SFC), how the technique evolved from gas and liquid chromatography and how the instrumentation was developed. Over the last two years, a commercial, dedicated packed-column SFC/MS instrument appeared on the market. The SFC continues to grow in use, with fundamental developments, coupled with a steady rise in the number of industrial users and applications.
Resumo:
The aim of this work was to develop and to validate a methodology using HPLC for the simultaneous determination of folates and folic acid in foods. The limits of detection and the recovery rates for the vitamins in the certified reference materials were respectively 5 pg/mL and 94-108% for 5-MTHF, 7 pg/mL and 97-102% for THF, 30 pg/mL and 97.9-104% for 5-FTHF, 30 pg/mL and 95-107 for 10-FFA, 5 ng/mL and 97-102% for FA and 5 ng/mL and 98-103% for 10-MFA. Repeatability showed a coefficient of variation below 3.9% for all the vitamins. The proposed methodology was shown to be efficient when applied to different certified reference materials, namely pig's liver (BCR487), powdered milk (BCR421) and a vegetable mixture (BCR485).
Resumo:
The environmental impact of detergents and other consumer products is behind the continued interest in the chemistry of the surfactants used. Of these, linear alkylbenzene sulfonates (LASs) are most widely employed in detergent formulations. The precursors to LASs are linear alkylbenzenes (LABs). There is also interest in the chemistry of these hydrocarbons, because they are usually present in commercial LASs (due to incomplete sulfonation), or form as one of their degradation products. Additionally, they may be employed as molecular tracers of domestic waste in the aquatic environment. The following aspects are covered in the present review: The chemistry of surfactants, in particular LAS; environmental impact of the production of LAS; environmental and toxicological effects of LAS; mechanisms of removal of LAS in the environment, and methods for monitoring LAS and LAB, the latter in domestic wastes. Classical and novel analytical methods employed for the determination of LAS and LAB are discussed in detail, and a brief comment on detergents in Brazil is given.
Resumo:
Nanomaterials make up an emerging area in Chemistry and in the science of materials. This area constitutes the development of methods for synthesizing nanoscopic particles of a given material used for scientific investigation. Nanomaterials have a wide range of commercial possibilities and technological applications, including their use in analytical chemistry, as well as in electronics, optics, engineering, medicine, devices for liberation of drugs, bioencapsulation, among others. This paper presents a summary about nanoelectrodes, devices built from nanoparticles, which show great potential as electrochemical tools in many different types of analysis. The purpose of this paper is to review the construction methodologies of nanoelectrodes, and to point out their successful applicability in the various fields of immune assays and other analytical procedures with quantitative purposes.
Resumo:
Process Analytical Chemistry (PAC) is an important and growing area in analytical chemistry, that has received little attention in academic centers devoted to the gathering of knowledge and to optimization of chemical processes. PAC is an area devoted to optimization and knowledge acquisition of chemical processes, to reducing costs and wastes and to making an important contribution to sustainable development. The main aim of this review is to present to the Brazilian community the development and state of the art of PAC, discussing concepts, analytical techniques currently employed in the industry and some applications.
Resumo:
In recent years, because of the need for a more flexible curriculum established by the Curriculum Guidelines of the National Brazilian Education (law 9394/96), the pedagogical project of the Chemistry course of FFCLRP/USP has undergone alterations, amongst them the gradual reduction of the hours devoted to the discipline Qualitative Analytical Chemistry. In this context, this discipline has been carefully analyzed and reorganized in order to allow the elimination of redundancies and the introduction of activities considered important for the professional formation of both chemists and chemistry teachers. In this work, we will discuss the main strategies adopted in this reorganization with the objective of making the teaching/learning process more dynamic and efficient.
Resumo:
Itraconazole is a synthetic antifungal drug administered orally with a broad spectrum of activity against mycotic infections. The present work consists of the development and validation of analytical methodology for evaluation of itraconazole in pharmaceutical products by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/diethylamine 0.05% v/v, 60:40 v/v, pH 8.0 as mobile phase, methanol as solvent and detection and quantification at 254 nm. The results here obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 8.0-12.0 µg/mL of itraconazole. The method was applied to pharmaceutical capsules containg itraconazole pellets and showed to be efficient, yielding good results.
Resumo:
Pantoprazole is a proton pump inhibitor used in the treatment of digestive ulcers, gastro-esophageal reflux disease and in the eradication of Helicobacter pylori. In this work, an analytical method was developed and validated for the quantification of sodium pantoprazole by HPLC. The method was specific, linear, precise and exact. In order to verify the stability of pantoprazole during dissolution assays, pantoprazole solution in phosphate buffer pH 7.4 was kept at room temperature and protected from light for 22 days. Pantoprazole presented less than 5% of degradation in 6 hours and the half live of the degradation was 124 h.
Resumo:
The aim of this work was to develop and validate an analytical methodology for simultaneous determination of mebendazole and thiabendazole, two benzimidazoles used as anthelmintics. The method was based on high performance liquid chromatography, using a C18 column, a mobile phase composed of KH2PO4 0.05 mol L-1 and methanol 40:60 (v/v) and UV detection at 312 nm. The results showed that the method presented linearity from 60.0 to 140.0 µg mL-1 for mebendazole and from 99.6 to 232.4 g µL-1 for thiabendazole and it was considered selective, accurate, precise and robust according to the specific resolution from ANVISA, the Brazilian regulatory agency.
Resumo:
Considered the best substitute for diesel, biodiesel can be blended with diesel in any ratio, bringing lots of environmental, economic and social advantages. Brazilian law Nº 11097/2005, proposes the introduction of biodiesel in to the Brazilian energy matrix, mixed with diesel at a minimum percentage of 2%. For consumers and sellers to be sure that the commercialized mixture of biodiesel:diesel contains the correct percentage, it is necessary to develop analytical methodologies to quantify the amount of biodiesel added. This work presents a fast, low-cost and simple methodology to determine the biodiesel proportion in mixtures of biodiesel:diesel, based on infrared spectroscopy.
Resumo:
This paper is a translation of an IUPAC document by K. Danzer, M. Otto and L. A. Currie (Pure Appl. Chem., 2004, 76(6), 1215-1225). Its goal is to establish a uniform and meaningful standard for terminology (in Portuguese), notation, and formulation concerning multispecies calibration in analytical chemistry. Calibration in analytical chemistry refers to the relation between sample domain and measurement domain (signal domain) expressed by an analytical function x = f s (Q) representing a pattern of chemical species Q and their amounts or concentrations x in a given test sample and a measured function y = f (z) that may be a spectrum, chromatogram, etc. Simultaneous multispecies analyses are carried out mainly by spectroscopic and chromatographic methods in a more or less selective way. For the determination of n species Qi (i=1,2, ..., n), at least n signals must be measured which should be well separated in the ideal case. In analytical practice, the situation can be different.
Resumo:
A chromatographic method was developed for cholesterol determination in feed for ruminants using response surface methodology. Among the five approaches of sample preparation methods tested, the saponification of the sample without heating presented less interference in the gas chromatography. The method presented a relative standard deviation (RSD) of 4.3%, recoveries between 84 and 87% and detection limit of 0.001 mg of cholesterol per g of feed.