978 resultados para Compact Wideband Antenna
Resumo:
Modern fully integrated receiver architectures, require inductorless circuits to achieve their potential low area, low cost, and low power. The low noise amplifier (LNA), which is a key block in such receivers, is investigated in this thesis. LNAs can be either narrowband or wideband. Narrowband LNAs use inductors and have very low noise figure, but they occupy a large area and require a technology with RF options to obtain inductors with high Q. Recently, wideband LNAs with noise and distortion cancelling, with passive loads have been proposed, which can have low NF, but have high power consumption. In this thesis the main goal is to obtain a very low area, low power, and low-cost wideband LNA. First, it is investigated a balun LNA with noise and distortion cancelling with active loads to boost the gain and reduce the noise figure (NF). The circuit is based on a conventional balun LNA with noise and distortion cancellation, using the combination of a common-gate (CG) stage and common-source (CS) stage. Simulation and measurements results, with a 130 nm CMOS technology, show that the gain is enhanced by about 3 dB and the NF is reduced by at least 0.5 dB, with a negligible impact on the circuit linearity (IIP3 is about 0 dBm). The total power dissipation is only 4.8 mW, and the active area is less than 50 x 50 m2 . It is also investigated a balun LNA in which the gain is boosted by using a double feedback structure.We propose to replace the load resistors by active loads, which can be used to implement local feedback loops (in the CG and CS stages). This will boost the gain and reduce the noise figure (NF). Simulation results, with the same 130 nm CMOS technology as above, show that the gain is 24 dB and NF is less than 2.7 dB. The total power dissipation is only 5.4 mW (since no extra blocks are required), leading to a figure-of-merit (FoM) of 3.8 mW
Resumo:
The regeneration of soft biological tissues requires new substitutes that exhibit mechanical properties similar to the native tissue. Herein, thin saloplastic membranes with tunable physical properties are prepared by complexation of chitosan and alginate solutions containing different concentrations of sodium chloride. Polyelectrolyte complexes (PECs) are transferred to flat Petri dishes for compaction into membrane shapes by sedimentation and solvent evaporation. All membranes are resistant to degradation by lysozyme and are stable in solutions with pH values between 1 and 13. Immersing the different membranes in new doping solutions of increasing salt concentrations triggers the typical saloplastic behavior, with a high water absorption and decrease of the rigidity and ultimate tensile strength. The range of such variations is tuned by the sodium chloride amount used in the synthesis: high salt concentrations increase water uptake and tensile moduli, while decreasing the ultimate strength. Cellular assays demonstrate high proliferation rates and viability of L929 fibroblasts seeded onto the most rigid membranes. The results validate the use of saloplastic membranes as soft tissue substitutes for future biomedical applications.
Resumo:
El presente proyecto de investigación solicitado es continuacion de una línea de trabajo con insumos de desecho agroindustrial regional en la provincia de Cordoba. Prevé aportes que contribuyan a la sustentabilidad económica y social, y ambiental. Se trata de aportar valor agregado a importantes cantidades residuales de cascaras de mani. Además promueve la produccion de materiales y componentes de construcción de viviendas saludables y accesibles para sectores con necesidades sociohabitacionales.El deshecho de cáscara de maní constituye hoy en la provincia de Córdoba, un recurso sobre abundante no aprovechado en la escala en que se dispone. Existen desarrollos para su aprovechamiento - camadas de aves, alimento de ganado, carbon activado- , que no alcanzan a consumir las enormes cantidades de cascaras que se disponen hoy: alrededor de 250 000 Tn/ año. (La produccion anual de mani en caja en la provincia de Cordoba es estimada en 700.000 Tn/año)A partir de los resultados ya obtenidos con paneles livianos termoaislantes, utilizados en cielorrasos y tabiques divisorios, el nuevo trabajo de investigación y desarrollo se propone avanzar sobre las condiciones de produccion de tableros compactos, similares a los producidos comercialmente con residuos de la industria de la madera. Se estudiaran y experimentaran las propiedades de uso de resinas poliester, ureaformaldehido y fenolformaldehido, bajo condiciones de alta presion y temperatura. En la primera etapa (1º año) buscamos obtener nuevos materiales en escala de probetas.En una etapa siguiente (2º año), los nuevos materiales obtenidos serán aplicados al diseño de componentes de vivienda. Se estudiarán las posibilidades alternativas de empleo en relación a los parámetros de evaluación : peso, resistencia mecánica, aislación térmica, resistencia a la humedad, y al envejecimiento acelerado.En la última etapa (3º año) los resultados obtenidos serán aplicados en modelos de escala real y/o prototipos demostrativos para evaluar su puesta en servicio.
Resumo:
Surgical procedures such as osteotomy and hip replacement involve the cutting of bone with the aid of various manual and powered cutting instruments including manual and powered bone saws. The basic mechanics of bone sawing processes are consistent with most other material sawing processes such as for wood or metal. Frictional rubbing between the blade of the saw and the bone results in the generation of localised heating of the cut bone. Research studies have been carried out which consider the design of the bone saw which deals with specifics of the saw teeth geometry and research which examines the effect of drilling operations on heating of the bone has shown that elevated temperatures will occur from frictional overheating. This overheating in localised areas is known to have an impact on the rate of healing of the bone post operation and the sharpness life of the blade. The purpose of this study was to measure the temperature at three zones at fixed intervals of 3mm, 6mm, and 9mm away from the cutting zone. It should be noted that it was the first time that this measurement technique was used to measure the temperature gradient through the bone specimen thereby establishing the extent to which clinicians are experiencing thermal injury during sawing of bone while using a reciprocating saw. The effect of various cutting feed rate on temperature elevation was also investigated in this research. The results showed that there will be a region of bone at least 9mm either side of the cutting blade experiencing thermal injury as temperatures in this region exceeded the threshold temperature of 44°C for necrosis (cell death).
Resumo:
Surgeons may use a number of cutting instruments such as osteotomes and chisels to cut bone during an operative procedure. The initial loading of cortical bone during the cutting process results in the formation of microcracks in the vicinity of the cutting zone with main crack propagation to failure occuring with continued loading. When a material cracks, energy is emitted in the form of Acoustic Emission (AE) signals that spread in all directions, therefore, AE transducers can be used to monitor the occurrence and development of microcracking and crack propagation in cortical bone. In this research, number of AE signals (hits) and related parameters including amplitude, duration and absolute energy (abs-energy) were recorded during the indentation cutting process by a wedge blade on cortical bone specimens. The cutting force was also measured to correlate between load-displacement curves and the output from the AE sensor. The results from experiments show AE signals increase substantially during the loading just prior to fracture between 90% and 100% of maximum fracture load. Furthermore, an amplitude threshold value of 64dB (with approximate abs-energy of 1500 aJ) was established to saparate AE signals associated with microcracking (41 – 64dB) from fracture related signals (65 – 98dB). The results also demonstrated that the complete fracture event which had the highest duration value can be distinguished from other growing macrocracks which did not lead to catastrophic fracture. It was observed that the main crack initiation may be detected by capturing a high amplitude signal at a mean load value of 87% of maximum load and unsteady crack propagation may occur just prior to final fracture event at a mean load value of 96% of maximum load. The author concludes that the AE method is useful in understanding the crack initiation and fracture during the indentation cutting process.
Resumo:
Theoretische Elektrotechnik, Elektromagnetische Verträglichkeit, Antennentheorie, Elektrodynamik, Mathematische Methoden der Physik, Leitungstheorie, Mikrowellentechnik, Hohlraumresonatoren
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2009
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2010
Resumo:
We study of noncompact Euclidean cone manifolds with cone angles less than c&2π and singular locus a submanifold. More precisely, we describe its structure outside a compact set. As a corol lary we classify those with cone angles & 2π/3 and those with cone angles = 2π/3.
Resumo:
Estudi elaborat a partir d’una estada a l’ Imperial College London, entre juliol i novembre de 2006. En aquest treball s’ha investigat la geometria més apropiada per a la caracterització de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. L’objectiu és assegurar la propagació de l’esquerda sense que la proveta falli abans per cap altre mecanisme de dany per tal de permetre la caracterització experimental de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. Amb aquesta fi, s’ha dut a terme l’anàlisi paramètrica de diferents tipus de provetes mitjançant el mètode dels elements finits (FE) combinat amb la virtual crack closure technique (VCCT). Les geometries de les provetes analitzades corresponen a la proveta de l’assaig compact tension (CT) i diferents variacions com la extended compact tension (ECT), la proveta widened compact tension (WCT), tapered compact tension (TCT) i doubly-tapered compact tension (2TCT). Com a resultat d’aquestes anàlisis s’han derivat diferents conclusions per obtenir la geometria de proveta més apropiada per a la caracterització de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. A més, també s’han dut a terme una sèrie d’assaigs experimentals per tal de validar els resultats de les anàlisis paramètriques. La concordança trobada entre els resultats numèrics i experimentals és bona tot i la presència d’efectes no previstos durant els assaigs experimentals.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
Given the urgence of a new paradigm in wireless digital trasmission which should allow for higher bit rate, lower latency and tigher delay constaints, it has been proposed to investigate the fundamental building blocks that at the circuital/device level, will boost the change towards a more efficient network architecture, with high capacity, higher bandwidth and a more satisfactory end user experience. At the core of each transciever, there are inherently analog devices capable of providing the carrier signal, the oscillators. It is strongly believed that many limitations in today's communication protocols, could be relieved by permitting high carrier frequency radio transmission, and having some degree of reconfigurability. This led us to studying distributed oscillator architectures which work in the microwave range and possess wideband tuning capability. As microvave oscillators are essentially nonlinear devices, a full nonlinear analyis, synthesis, and optimization had to be considered for their implementation. Consequently, all the most used nonlinear numerical techniques in commercial EDA software had been reviewed. An application of all the aforementioned techniques has been shown, considering a systems of three coupled oscillator ("triple push" oscillator) in which the stability of the various oscillating modes has been studied. Provided that a certain phase distribution is maintained among the oscillating elements, this topology permits a rise in the output power of the third harmonic; nevertheless due to circuit simmetry, "unwanted" oscillating modes coexist with the intenteded one. Starting with the necessary background on distributed amplification and distributed oscillator theory, the design of a four stage reverse mode distributed voltage controlled oscillator (DVCO) using lumped elments has been presented. All the design steps have been reported and for the first time a method for an optimized design with reduced variations in the output power has been presented. Ongoing work is devoted to model a wideband DVCO and to implement a frequency divider.
Resumo:
We present a compact portable biosensor to measure arsenic As(III) concentrations in water using Escherichia coli bioreporter cells. Escherichia coli expresses green fluorescent protein in a linearly dependent manner as a function of the arsenic concentration (between 0 and 100 μg/L). The device accommodates a small polydimethylsiloxane microfluidic chip that holds the agarose-encapsulated bacteria, and a complete optical illumination/collection/detection system for automated quantitative fluorescence measurements. The device is capable of sampling water autonomously, controlling the whole measurement, storing and transmitting data over GSM networks. We demonstrate highly reproducible measurements of arsenic in drinking water at 10 and 50 μg/L within 100 and 80 min, respectively.