952 resultados para Chromatography liquid with fluorescence detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, folates were evaluated in the main species of mushroom cultivated in Brazil. The species analysed were Agaricus bisporus (button mushroom), Lentinula edodes (shiitake) and Pleorotus ostreatus (shimeji). The five main forms of folate found in foods were determined: tetrahydrofolic acid (THFA), 10-methyl folic acid (10MFA), 5-methyl tetrahydrofolic acid (5MTHFA), 10-formyl folic acid (10FFA) and 5-formy tetrahydrofolic acid (5FTHFA). The methodology employed used extraction with phosphate buffer, clean up with trichloroacetic acid and separation of the vitamins by high-performance liquid chromatography, with simultaneous ultraviolet and fluorescence detection. The results obtained for total folate were 551 to 1404 µg.100 g -1 for the button mushroom, 606 to 727 µg.100 g -1 for shiitake and 460 to 1325 µg.100 g-1 for shimeji. The data showed that mushrooms could be considered as sources of folates and that their contribution of these vitamins to the diet was meaningful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Factors involved in the determination of PAHs (16 priority PAHs as an example) and PCBs (10 PCB congeners, representing 10 isomeric groups) by capillary gas chromatography coupled with mass spectrometry (GC/MS, for PAHs) and electron capture detection (GC/ECD , for PCBs) were studied, with emphasis on the effect of solvent. Having various volatilities and different polarities, solvent studied included dichloromethane, acetonitrile, hexan e, cyclohexane, isooctane, octane, nonane, dodecane, benzene, toluene, p-xylene, o-xylene, and mesitylene. Temperatures of the capillary column, the injection port, the GC/MS interface, the flow rates of carrier gas and make-up gas, and the injection volume were optimized by one factor at a time method or simplex optimization method. Under the optimized conditions, both peak height and peak area of 16 PAHs, especially the late-eluting PAHs, were significantly enhanced (1 to 500 times) by using relatively higher boiling point solvents such as p-xylene and nonane, compared with commonly used solvents like benzene and isooctane. With the improved sensitivity, detection limits of between 4.4 pg for naphthalene and 30.8 pg for benzo[g,h,i]perylene were obtained when p-xylene was used as an injection solvent. Effect of solvent on peak shape and peak intensity were found to be greatly dependent on temperature parameters, especially the initial temperature of the capillary column. The relationship between initial temperature and shape of peaks from 16 PAHs and 10 PCBs were studied and compared when toluene, p-xylene, isooctane, and nonane were used as injection solvents. If a too low initial temperature was used, fronting or split of peaks was observed. On the other hand, peak tailing occurred at a too high initial column temperature. The optimum initial temperature, at which both peak fronting and tailing were avoided and symmetrical peaks were obtained, depended on both solvents and the stationary phase of the column used. On a methyl silicone column, the alkane solvents provided wider optimum ranges of initial temperature than aromatic solvents did, for achieving well-shaped symmetrical GC peaks. On a 5% diphenyl: 1% vinyl: 94% dimethyl polysiloxane column, when the aromatic solvents were used, the optimum initial temperature ranges for solutes to form symmetrical peaks were improved to a similar degree as those when the alkanes were used as injection solvents. A mechanism, based on the properties of and possible interactions among the analyte, the injection solvent, and the stationary phase of the capillary column, was proposed to explain these observations. The effect of initial temperature on peak height and peak area of the 16 PAHs and the 10 PCBs was also studied. The optimum initial temperature was found to be dependent on the physical properties of the solvent used and the amount of the solvent injected. Generally, from the boiling point of the solvent to 10 0C above its boiling point was an optimum range of initial temperature at which cthe highest peak height and peak area were obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La protéomique est un sujet d'intérêt puisque l'étude des fonctions et des structures de protéines est essentiel à la compréhension du fonctionnement d'un organisme donné. Ce projet se situe dans la catégorie des études structurales, ou plus précisément, la séquence primaire en acides aminés pour l’identification d’une protéine. La détermination des protéines commence par l'extraction d'un mélange protéique issu d'un tissu ou d'un fluide biologique pouvant contenir plus de 1000 protéines différentes. Ensuite, des techniques analytiques comme l’électrophorèse en gel polyacrylamide en deux dimensions (2D-SDS-PAGE), qui visent à séparer ce mélange en fonction du point isoélectrique et de la masse molaire des protéines, sont utilisées pour isoler les protéines et pour permettre leur identification par chromatographie liquide and spectrométrie de masse (MS), typiquement. Ce projet s'inspire de ce processus et propose que l'étape de fractionnement de l'extrait protéique avec la 2D-SDS-PAGE soit remplacé ou supporté par de multiples fractionnements en parallèle par électrophorèse capillaire (CE) quasi-multidimensionnelle. Les fractions obtenues, contenant une protéine seule ou un mélange de protéines moins complexe que l’extrait du départ, pourraient ensuite être soumises à des identifications de protéines par cartographie peptidique et cartographie protéique à l’aide des techniques de séparations analytiques et de la MS. Pour obtenir la carte peptidique d'un échantillon, il est nécessaire de procéder à la protéolyse enzymatique ou chimique des protéines purifiées et de séparer les fragments peptidiques issus de cette digestion. Les cartes peptidiques ainsi générées peuvent ensuite être comparées à des échantillons témoins ou les masses exactes des peptides enzymatiques sont soumises à des moteurs de recherche comme MASCOT™, ce qui permet l’identification des protéines en interrogeant les bases de données génomiques. Les avantages exploitables de la CE, par rapport à la 2D-SDS-PAGE, sont sa haute efficacité de séparation, sa rapidité d'analyse et sa facilité d'automatisation. L’un des défis à surmonter est la faible quantité de masse de protéines disponible après analyses en CE, due partiellement à l'adsorption des protéines sur la paroi du capillaire, mais due majoritairement au faible volume d'échantillon en CE. Pour augmenter ce volume, un capillaire de 75 µm était utilisé. Aussi, le volume de la fraction collectée était diminué de 1000 à 100 µL et les fractions étaient accumulées 10 fois; c’est-à-dire que 10 produits de séparations étaient contenu dans chaque fraction. D'un autre côté, l'adsorption de protéines se traduit par la variation de l'aire d'un pic et du temps de migration d'une protéine donnée ce qui influence la reproductibilité de la séparation, un aspect très important puisque 10 séparations cumulatives sont nécessaires pour la collecte de fractions. De nombreuses approches existent pour diminuer ce problème (e.g. les extrêmes de pH de l’électrolyte de fond, les revêtements dynamique ou permanent du capillaire, etc.), mais dans ce mémoire, les études de revêtement portaient sur le bromure de N,N-didodecyl-N,N-dimethylammonium (DDAB), un surfactant qui forme un revêtement semi-permanent sur la paroi du capillaire. La grande majorité du mémoire visait à obtenir une séparation reproductible d'un mélange protéique standard préparé en laboratoire (contenant l’albumine de sérum de bovin, l'anhydrase carbonique, l’α-lactalbumine et la β-lactoglobulin) par CE avec le revêtement DDAB. Les études portées sur le revêtement montraient qu'il était nécessaire de régénérer le revêtement entre chaque injection du mélange de protéines dans les conditions étudiées : la collecte de 5 fractions de 6 min chacune à travers une séparation de 30 min, suivant le processus de régénération du DDAB, et tout ça répété 10 fois. Cependant, l’analyse en CE-UV et en HPLC-MS des fractions collectées ne montraient pas les protéines attendues puisqu'elles semblaient être en-dessous de la limite de détection. De plus, une analyse en MS montrait que le DDAB s’accumule dans les fractions collectées dû à sa désorption de la paroi du capillaire. Pour confirmer que les efforts pour recueillir une quantité de masse de protéine étaient suffisants, la méthode de CE avec détection par fluorescence induite par laser (CE-LIF) était utilisée pour séparer et collecter la protéine, albumine marquée de fluorescéine isothiocyanate (FITC), sans l'utilisation du revêtement DDAB. Ces analyses montraient que l'albumine-FITC était, en fait, présente dans la fraction collecté. La cartographie peptidique a été ensuite réalisée avec succès en employant l’enzyme chymotrypsine pour la digestion et CE-LIF pour obtenir la carte peptidique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El glifosat, N-(fosfonometil) glicina, és un dels herbicides més utilitzats arreu del món a causa de la seva baixa toxicitat i al seu ampli espectre d'aplicació. A conseqüència del gran ús que se'n fa, és necessari monitoritzar aquest compost i el seu principal metabòlit, l'àcid aminometilfosfònic (AMPA), en el medi ambient. S'han descrit diversos mètodes instrumentals basats en cromatografia de gasos (GC) i de líquids (HPLC), sent aquesta darrera l'opció més favorable a causa del caràcter polar dels anàlits. Per assolir nivells de concentració baixos cal, però, la preconcentració dels anàlits. En aquest treball s'estudien diferents alternatives amb aquest objectiu. S'ha avaluat la tècnica de membrana líquida suportada (SLM) on la membrana consisteix en una dissolució orgànica, que conté un transportador (en el nostre cas, un bescanviador d'anions comercial, Aliquat 336), que impregna un suport polimèric microporós que se situa entre dues solucions aquoses: la de càrrega, que conté els anàlits inicialment, i la receptora, on es retenen els anàlits després del seu transport a través de la membrana. Les condicions d'extracció més adequades s'obtenen treballant en medi bàsic amb NaOH on els anàlits estan en forma aniònica i les majors recuperacions s'obtenen amb HCl 0,1 M o NaCl 0,5 M, la qual cosa indica que l'ió clorur és la força impulsora del transport. Un cop dissenyat el sistema, es duen a terme experiments de preconcentració amb dues geometries diferents: un sistema de membrana laminar (LSLM) on recircula la fase receptora i un sistema de fibra buida (HFSLM). Els millors resultats s'obtenen amb el mòdul de fibra buida, amb factors de concentració de 25 i 3 per a glifosat i AMPA, respectivament, fent recircular durant 24 hores 100 ml de solució de càrrega i 4 ml de solució receptora. També s'aplica una tècnica més selectiva, la cromatografia d'afinitat amb ió metàl·lic immobilitzat (IMAC), basada en la interacció entre els anàlits i un metall immobilitzat en una resina a través d'un grup funcional d'aquesta. En aquest estudi s'immobilitza pal·ladi al grup funcional 8-hidroxiquinoleïna de la resina amb matriu acrílica Spheron Oxine 1000 i s'avalua per a l'extracció i preconcentració de glifosat i AMPA. Per a ambdós anàlits l'adsorció és del 100 % i les recuperacions són superiors al 80 % i al 60 % per a glifosat i AMPA, respectivament, utilitzant HCl 0,1 M + NaCl 1 M com a eluent. Aquests resultats es comparen amb els obtinguts amb dues resines més, també carregades amb pal·ladi: Iontosorb Oxin 100, que té el mateix grup funcional però matriu de cel·lulosa, i Spheron Thiol 1000, on el grup funcional és un tiol i la matriu també és acrílica. Per al glifosat els resultats són similars amb totes les resines, però per a l'AMPA la resina Spheron Thiol és la única que proporciona recuperacions superiors al 93 %. Finalment, una altra opció estudiada és l'acoblament de dues columnes de cromatografia líquida (LC-LC). En l'estudi l'objectiu és millorar el mètode existent per a glifosat i AMPA en aigües naturals on el LOD era de 0,25 ug/l. El mètode consisteix en la derivatització precolumna amb el reactiu fluorescent FMOC i l'anàlisi amb l'acoblament LC-LC-fluorescència. Variant lleugerament les condicions de derivatització s'aconsegueix quantificar 0,1 ug/l de glifosat i AMPA. Es fortifiquen aigües naturals amb 0,1, 1 i 10 ug/l dels anàlits per validar el mètode. S'obtenen recuperacions d'entre el 85 % i el 100 %, amb desviacions estàndard relatives inferiors al 8 %. Aplicant una tècnica de preconcentració prèvia a la derivatització i anàlisi utilitzant una resina de bescanvi aniònic, Amberlite IRA-900, es millora la sensibilitat del mètode i s'assoleix un LOD per al glifosat de 0,02 ug/l.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a RP-HPLC method for the simultaneous quantification of free amino acids and biogenic amines in liquid food matrices and the results of the application to honey and wine samples obtained from different production processes and geographic origins. The developed methodology is based on a pre-column derivatization with o-phthaldialdehyde carried out in the sample injection loop. The compounds were separated in a Nova-Pack RP-C18 column (150 mm × 3.9 mm, 4 μm) at 35 °C. The mobile phase used was a mixture of phase A: 10 mM sodium phosphate buffer (pH 7.3), methanol and tetrahydrofuran (91:8:1); and phase B: methanol and phosphate buffer (80:20), with a flow rate of 1.0 ml/min. Fluorescence detection was used at an excitation wavelength of 335 nm and an emission wavelength of 440 nm. The separation and quantification of 19 amino acids and 6 amines was carried out in a single run as their OPA/MCE derivatives elute within 80 min, ensuring a reproducible quantification. The method showed to be adequate for the purpose, with an average RSD of 2% for the different amino acids; detection limits varying between 0.71 mg/l (Asn) and 8.26 mg/l (Lys) and recovery rates between 63.0% (Cad) and 98.0% (Asp). The amino acids present at the highest concentration in honey and wine samples were phenylalanine and arginine, respectively. Only residual levels of biogenic amines were detected in the analysed samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tomato (Lycopersicon esculentum L.) is one of the main constituents of the Mediterranean diet. Its consumption has been proposed to reduce the risk of cardiovascular diseases and certain types of cancer. It is therefore one of the most popular and extensively consumed vegetable crop worldwide. To gain insights on the potential of Lycopersicon esculentum L. as bioactive food, two analytical methodologies were developed to determine the levels of the lipophilic -tocopherol, α-tocopherol, β-carotene, lycopene; and hydrophilic antioxidants ascorbic acid. The quantification of total carotenoids (β-carotene and lycopene) was assessed through a liquidliquid ultrasound assisted extraction (LL-USAE) in combination with ultraviolet-visible spectroscopy (UV-Vis), according to method of mean, for total carotenoids (λmáx = 450 nm. The ultra-high performance liquid chromatographic using both photodiode array and fluorescence detection (UHPLC-PDA/FLR), allows the identification and quantification of the target lipophilic and hydrophilic antioxidants. This methodology UHPLC-PDA/FLR is fast, simple and revealed a high sensitivity for the compounds under study. The limits of detection (LODs) and quantification (LOQs) obtained were much lower (about 10 times) than the reported in literature. The method LL-USAE/UV-Vis was validated and applied to different tomato foodstuffs. The results reveal a small increase of carotenoids content during maturation, reaching the maximum level when ripe. These results complement those obtained by the ORAC and TBARS assays that show an increase of antioxidant capacity during maturation. The LODs ans LOQs obtained were also about 10 times lower than reported in literature. The carotenoid content was also evaluated by LL-USAE/UV-Vis in different tomatoes varieties. Regional variety present the high carotenoid level, followed by campari and gordal, and at last grape. This methodology was also applied to different processed food samples containing tomatoes derivatives. Highest carotenoids content were obtained in concentrated tomato foodstuffs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method was developed to determine simazine, atrazine and their metabolite, 2-chloro-4,6-diamino-1,3,5-triazine, in urine. The presence of these herbicides in urine may reflect possible exposure to pesticides. Sample preparation involved protein precipitation and solid-phase extraction. The samples were analyzed by high-performance liquid chromatography-mass spectrometry. The detection limits were 0.4 mug/l and the analytes have a linear response in the interval 6-800 mug/l. The precision of the method was reflected in the RSD of <2.4% for the herbicides studied. Based on the detectable herbicide levels from spiked urine samples collected from unexposed volunteers, this method can be used to determine the low levels necessary for establishing reference values of the selected herbicides and the metabolite. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 2,4-dichlorophenoxyacetic acid (2,4-D) is one of the most applied herbicides around the world to control broad leave herbs in many crops: In this study, a method was developed for simultaneous extraction and determination of 2,4D and its major transformation product, i.e., the 2,4-dichlorophenol (2,4-DCP), in soil samples. The herbicide and its degradation product were extracted twice from soil samples, after acidification, by dichloromethane on ultrasound system for 1 h. Both extracts were combined and filtrated in qualitative filter paper and Celitee. The total extract was concentrated in rotatory evaporator, dried under N-2 and finally dissolved in 1 ml of methanol. High Performance Liquid Chromatography with UV detection at 230 nm was used for analysis. Recoveries were obtained from soil samples fortified at 0.1, 1.0, 2.0, 3.0 and 4.0 mg kg(-1) levels and the results varied from 85 to 111% (for 2,4-D) and from 95 to 98% (for 2,4-DCP). For both compounds, the limits of quantification were 0.1 mg kg(-1), which were the loss level at which the accuracy and the precision were studied. Nevertheless, the limits of detection, calculated by considering the blank standard deviation and the minimum concentration level, were 0.03 and 0.02 mg kg for 2,4-D and 2,4-DCP, respectively. This proposed method was applied to soil samples of eucalyptus crops, which was previously treated with the herbicide. Despite that, neither 2,4-D nor its degradation product were detected 30 days after the herbicide application. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste estudo foi determinada a relação entre as concentrações plasmáticas e eritrocitárias de quinina em crianças com malária falciparum não complicada, oriundas de área endêmica da Região Amazônica. A quinina foi detrminada por cromatografia líquida de alta eficiência. No estado de equilíbrio, a relação foi 1,89 ± 1,25 variando de 1,05 a 2,34. Estes resultados demonstraram que a quinina não se concentra nos eritrócitos das crianças e caracterizaram a ausência de diferença racial nesta relação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente estudo descreve um método eficiente e simples utilizando cromatografia líquida de alta eficiência (CLAE) acoplada a detector de fluorescência para determinação dos parâmetros cinéticos da captação de glutamato (glu) no sistema nervoso central (SNC). O tecido retiniano embrionário de ave com sete dias de desenvolvimento foi incubado com concentrações conhecidas de glu (50-500 μM) por dez minutos. Os níveis do aminoácido derivado a partir de ortoftaldeído (OPA) no meio de incubação foram mensurados. Após avaliar a diferença entre a concentração de glu inicial e a final no meio, foi determinada a saturação do mecanismo de captação (Km = 8,2 e Vmax = 9,8 nmol/mg proteína/minuto). Estas determinações foram dependentes e independentes de sódio e temperatura, indicando que o mecanismo que regula a diminuição dos níveis de glu no SNC, é a captação via transportadores de alta afinidade. Além disso, o cloreto de zinco (ZnCl) (um inibidor do transportador glu/aspartato) foi utilizado em diversas concentrações e evocou diminuição da captação de glu. Com isto, destaca-se a elevada aplicabilidade desta metodologia. Além deste trabalho caracterizar metodologia alternativa para avaliar captação de glu no SNC usando CLAE, também pode ser importante ferramenta para estudos relacionados à caracterização do transporte do neurotransmissor durante injúrias no SNC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive method using solid phase microextraction (SPME) and liquid chromatography (LC) with heated online desorption (SPME-LC) was developed and validated to analyze anticonvulsants (AEDs) in human plasma samples. A heated lab-made interface chamber was used in the desorption procedure, which allowed the transference of the whole extracted sample. The SPME conditions were optimized by applying an experimental design. Important factors are discussed such as fiber coating types, pH, extraction time and desorption conditions. The drugs were analyzed by LC, using a C18 column (150 mm 4.6 mm 5 mm); and 50 mmol L1 , pH ¼ 5.50 ammonium acetate buffer : acetonitrile : methanol (55 : 22 : 23 v/v) as the mobile phase with a flow rate of 0.8 mL min1 . The suggested method presented precision (intra-assay and inter-assay), linearity and limit of quantification (LOQ) all adequate for the therapeutic drug monitoring (TDM) of AEDs in plasma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zebrafish are currently used at various stages of the drug discovery process and can be a useful and cost-effective alternative to some mammalian models. Nitric oxide (NO) plays an important role in physiology of zebrafish. The availability of appropriate analytical techniques to quantify the NO is crucial for studying its role in physiological and pathological conditions. This work aimed at establishing a high-performance liquid chromatography method for determination of NO levels in zebrafish larvae. Attempts were also made to assess the normal levels of NO at the first days postfertilization and the possible changes under pathological conditions. The method validation was quantitatively evaluated in terms of sensitivity, specificity, precision, accuracy, linearity, and recovery. NO levels from zebrafish larvae at the first days postfertilization and larvae challenged to N(G)-nitro-L-arginine methyl ester, sodium nitroprusside, Escherichia coil lipopolysaccharide, and copper sulfate were analyzed. The samples were derivatized with 2,3-diaminonaphthalene, and fluorescence detection was used for the indirect determination of NO. The method showed a good performance for all validation parameters evaluated and was efficient to monitor changes in NO concentration under physiological and pathophysiological conditions. This method might represent a powerful tool to be applied in NO studies with zebrafish larvae. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study describes the enantioselective analysis of unbound and total concentrations of tramadol and its main metabolites O-desmethyltramadol (M1) and N-desmethyltramadol (M2) in human plasma. Sample preparation was preceded by an ultrafiltration step to separate the unbound drug. Both the ultrafiltrate and plasma samples were submitted to liquid/liquid extraction with methyl t-butyl ether. Separation was performed on a Chiralpak (R) AD column and tandem mass spectrometry consisting of an electrospray ionization source, positive ion mode and multiple reaction monitoring was used as the detection system. Linearity was observed in the following ranges: 0.2-600 and 0.5-250 ng/mL for analysis of total and unbound concentrations of the tramadol enantiomers, respectively, and 0.1-300 and 0.25-125 ng/mL for total and unbound concentrations of the M1 and M2 enantiomers, respectively. The lower limits of quantitation were 0.2 and 0.5 ng/mL for analysis of total and unbound concentration of each tramadol enantiomer, respectively, and 0.1 and 0.25 ng/mL for total and unbound concentrations of M1 and M2 enantiomers, respectively. Intra- and interassay reproducibility and inaccuracy did not exceed 15%. Clinical application of the method to patients with neuropathic pain showed plasma accumulation of (+)-tramadol and (+)-M2 after a single oral dose of racemic tramadol. Fractions unbound of tramadol, M1 or M2 were not enantioselective in the patients investigated. (C) 2011 Elsevier B.V. All rights reserved.