962 resultados para Cfd


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Use of high albedo materials reduces the amount of solar radiation absorbed through building envelops and urban structures and thus keeping their surfaces cooler. The cooling energy savings by using high albedo materials have been well documented. Higher surface temperatures add to increasing the ambient temperature as convection intensity is higher. Such temperature increase has significant impacts on the air conditioning energy utilization in hot climates. This study makes use of a parametric approach by varying the temperature of building facades to represent commonly used materials and hence analyzing its effect on the air temperature through a series of CFD (Computational Fluid Dynamics) simulations. A part of the existing CBD (Central Business District) area of Singapore was selected for the study. Series of CFD simulations have been carried out using the software CFX-5.6. Wind tunnel experiments were also conducted for validation. It was found that at low wind speeds, the effect of materials on the air temperature was significant and the temperature at the middle of a narrow canyon increased up to 2.52°C with the façade material having lowest albedo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bubble characteristics such as shape, size, and trajectory control the hydrodynamics and therefore heat transfer in fluidized bed reactors. Thus understanding these characteristics is very important for the design and scaleup of fluidized beds. An earlier developed Eulerian-Eulerian two-fluid model for simulating dense gas–solid two-phase flow has been used to compare the experimental data in a pseudo-two-dimensional (2-D) bed. Bubbles are injected asymmetrically by locating the nozzle at proximity to the wall, thus presenting the effect wall has on asymmetrical injection as compared to symmetrical injection. In this work, a digital image analysis technique was developed to study the bubble behaviour in a two-dimensional bubbling bed. The high-speed photography reveals an asymmetric wake formation during detachment indicating an early onset of mixing process. The wall forces acts tangentially on thebubble and has a significant impact on the bubble shape, neck formation during detachment and its trajectory through the bed. Larger bubbles drifting away from the centre with longer paths are observed. This qualitative behaviour is well predicted by CFD modelling. Asymmetric injection can significantly influence the heat and mass transfer characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate estimation of pressure drop due to vehicles inside an urban tunnel plays a pivotal role in tunnel ventilation issue. The main aim of the present study is to utilize computational intelligence technique for predicting pressure drop due to cars in traffic congestion in urban tunnels. A supervised feed forward back propagation neural network is utilized to estimate this pressure drop. The performance of the proposed network structure is examined on the dataset achieved from Computational Fluid Dynamic (CFD) simulation. The input data includes 2 variables, tunnel velocity and tunnel length, which are to be imported to the corresponding algorithm in order to predict presure drop. 10-fold Cross validation technique is utilized for three data mining methods, namely: multi-layer perceptron algorithm, support vector machine regression, and linear regression. A comparison is to be made to show the most accurate results. Simulation results illustrate that the Multi-layer perceptron algorithm is able to accurately estimate the pressure drop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fluidização de partículas é amplamente utilizada na indústria, principalmente devido às altas taxas de transferência de calor e massa entre as fases. O acoplamento entre a Dinâmica dos Fluidos Computacional (CFD – Computational Fluid Dynamics) e o Método dos Elementos Discretos (DEM – Discrete Element Method) tem se tornado atrativo para a simulação de fluidização, já que nesse caso o movimento das partículas é analisado de forma mais direta do que em outros tipos de abordagens. O grande problema do acoplamento CFD-DEM é a alta exigência computacional para rastrear todas as partículas do sistema, o que leva ao uso de estratégias de redução do tempo de simulação que em caso de utilização incorreta podem comprometer os resultados. O presente trabalho trata da aplicação do acoplamento CFD-DEM na análise de fluidização de alumina, que é um problema importante para o setor mineral. Foram analisados diversos parâmetros capazes de influenciar os resultados e o tempo de simulação como os passos de tempo, os modelos de arrasto, a distribuição granulométrica das partículas, a constante de rigidez, a utilização de partículas representativas com tamanho maior que o das partículas reais, etc. O modelo de força de interação DEM utilizado foi o modelo de mola e amortecedor lineares (LSD – Linear Spring Dashpot). Todas as simulações foram realizadas com o software ANSYS FLUENT 14.5 e os resultados obtidos foram comparados com dados experimentais e da literatura. Tais resultados permitiram comprovar a capacidade do modelo linear LSD em predizer o comportamento global de leitos de alumina e reduzir o tempo de simulação, desde que os parâmetros do modelo sejam definidos de forma adequada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a computational fluid dynamics (CFD) application about the axial fan design used in an agricultural spraying system with a theoretical and experimental analysis of comparative results between the characteristic curves of a fan for several rotations and numerical results for the influence of blade attack angle variation and optimization of the spraying system, both for a same rotation. Flow was considered three-dimensional, turbulent, isothermal, viscous and non-compressible in a steady state, disregarding any influence of the gravity field. The average turbulent field was obtained from the application of time average where the turbulence model required for closing the set of equations was the k-E model. Resolution of all connected phenomena was achieved with the help of a fluid dynamics computer, CFX, which uses the finite volumes technique as a numerical method. In order to validate the theoretical analysis, an experiment was conducted in a circular section of a horizontal wind tunnel, using a Pitot tube for pressure readings. The main results demonstrate that the methodology used, based on CFD techniques, is able to reproduce the phenomenological behavior of an axial fan in a spraying system because results were very reliable and similar to experimentally measured ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wall film model has been implemented in a customized version of KIVA code developed at University of Bologna. Under the hypothesis of `thin laminar ow' the model simulates the dynamics of a liquid wall film generated by impinging sprays. Particular care has been taken in numerical implementation of the model. The major phenomena taken into account in the present model are: wall film formation by impinging spray; body forces, such as gravity or acceleration of the wall; shear stress at the interface with the gas and no slip condition on the wall; momentum contribution and dynamic pressure generated by the tangential and normal component of the impinging drops; film evaporation by heat exchange with wall and surrounding gas. The model doesn't consider the effect of the wavy film motion and suppose that all the impinging droplets adhere to the film. The governing equations have been integrated in space by using a finite volume approach with a first order upwind differencing scheme and they have been integrated in time with a fully explicit method. The model is validated using two different test cases reproducing PFI gasoline and DI Diesel engine wall film conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this thesis was to improve the commercial CFD software Ansys Fluent to obtain a tool able to perform accurate simulations of flow boiling in the slug flow regime. The achievement of a reliable numerical framework allows a better understanding of the bubble and flow dynamics induced by the evaporation and makes possible the prediction of the wall heat transfer trends. In order to save computational time, the flow is modeled with an axisymmetrical formulation. Vapor and liquid phases are treated as incompressible and in laminar flow. By means of a single fluid approach, the flow equations are written as for a single phase flow, but discontinuities at the interface and interfacial effects need to be accounted for and discretized properly. Ansys Fluent provides a Volume Of Fluid technique to advect the interface and to map the discontinuous fluid properties throughout the flow domain. The interfacial effects are dominant in the boiling slug flow and the accuracy of their estimation is fundamental for the reliability of the solver. Self-implemented functions, developed ad-hoc, are introduced within the numerical code to compute the surface tension force and the rates of mass and energy exchange at the interface related to the evaporation. Several validation benchmarks assess the better performances of the improved software. Various adiabatic configurations are simulated in order to test the capability of the numerical framework in modeling actual flows and the comparison with experimental results is very positive. The simulation of a single evaporating bubble underlines the dominant effect on the global heat transfer rate of the local transient heat convection in the liquid after the bubble transit. The simulation of multiple evaporating bubbles flowing in sequence shows that their mutual influence can strongly enhance the heat transfer coefficient, up to twice the single phase flow value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, a multi physics simulation of an innovative safety system for light water nuclear reactor is performed, with the aim to increase the reliability of its main decay heat removal system. The system studied, denoted by the acronym PERSEO (in Pool Energy Removal System for Emergency Operation) is able to remove the decay power from the primary side of the light water nuclear reactor through a heat suppression pool. The experimental facility, located at SIET laboratories (PIACENZA), is an evolution of the Thermal Valve concept where the triggering valve is installed liquid side, on a line connecting two pools at the bottom. During the normal operation, the valve is closed, while in emergency conditions it opens, the heat exchanger is flooded with consequent heat transfer from the primary side to the pool side. In order to verify the correct system behavior during long term accidental transient, two main experimental PERSEO tests are analyzed. For this purpose, a coupling between the mono dimensional system code CATHARE, which reproduces the system scale behavior, with a three-dimensional CFD code NEPTUNE CFD, allowing a full investigation of the pools and the injector, is implemented. The coupling between the two codes is realized through the boundary conditions. In a first analysis, the facility is simulated by the system code CATHARE V2.5 to validate the results with the experimental data. The comparison of the numerical results obtained shows a different void distribution during the boiling conditions inside the heat suppression pool for the two cases of single nodalization and three volume nodalization scheme of the pool. Finaly, to improve the investigation capability of the void distribution inside the pool and the temperature stratification phenomena below the injector, a two and three dimensional CFD models with a simplified geometry of the system are adopted.