526 resultados para Centrifugal compressor
Resumo:
We present a weakly nonlinear analysis of the interface dynamics in a radial Hele-Shaw cell driven by both injection and rotation. We extend the systematic expansion introduced in [E. Alvarez-Lacalle et al., Phys. Rev. E 64, 016302 (2001)] to the radial geometry, and compute explicitly the first nonlinear contributions. We also find the necessary and sufficient condition for the uniform convergence of the nonlinear expansion. Within this region of convergence, the analytical predictions at low orders are compared satisfactorily to exact solutions and numerical integration of the problem. This is particularly remarkable in configurations (with no counterpart in the channel geometry) for which the interplay between injection and rotation allows that condition to be satisfied at all times. In the case of the purely centrifugal forcing we demonstrate that nonlinear couplings make the interface more unstable for lower viscosity contrast between the fluids.
Resumo:
We introduce a modification to Hele-Shaw flows consisting of a rotating cell. A viscous fluid (oil) is injected at the rotation axis of the cell, which is open to air. The morphological instability of the oil-air interface is thus driven by centrifugal force and is controlled by the density (not viscosity) difference. We derive the linear dispersion relation and verify the maximum growth rate selection of initial patterns within experimental uncertainty. The nonlinear growth regime is studied in the case of vanishing injection rate. Several characteristic lengths are studied to quantify the patterns obtained. Experimental data exhibit good collapse for two characteristic lengths, namely, the radius of gyration and the radial finger length, which in the nonlinear regime appear to grow linearly in time.
Resumo:
The radial displacement of a fluid annulus in a rotating circular Hele-Shaw cell has been investigated experimentally. It has been found that the flow depends sensitively on the wetting conditions at the outer interface. Displacements in a prewet cell are well described by Darcy's law in a wide range of experimental parameters, with little influence of capillary effects. In a dry cell, however, a more careful analysis of the interface motion is required; the interplay between a gradual loss of fluid at the inner interface, and the dependence of capillary forces at the outer interface on interfacial velocity and dynamic contact angle, result in a constant velocity for the interfaces. The experimental results in this case correlate in the form of an empirical scaling relation between the capillary number Ca and a dimensionless group, related to the ratio of centrifugal to capillary forces, which spans about three orders of magnitude in both quantities. Finally, the relative thickness of the coating film left by the inner interface, alpha i, is obtained as a function of Ca.
Resumo:
We have studied the interfacial instabilities experienced by a liquid annulus as it moves radially in a circular Hele-Shaw cell rotating with angular velocity Omega. The instability of the leading interface (oil displacing air) is driven by the density difference in the presence of centrifugal forcing, while the instability of the trailing interface (air displacing oil) is driven by the large viscosity contrast. A linear stability analysis shows that the stability of the two interfaces is coupled through the pressure field already at a linear level. We have performed experiments in a dry cell and in a cell coated with a thin fluid layer on each plate, and found that the stability depends substantially on the wetting conditions at the leading interface. Our experimental results of the number of fingers resulting from the instability compare well with the predictions obtained through a numerical integration of the coupled equations derived from a linear stability analysis. Deep in the nonlinear regime we observe the emission of liquid droplets through the formation of thin filaments at the tip of outgrowing fingers.
Resumo:
Fertilization and/or the accumulation of organic matter from plant residues can influence the composition of soil and litter community. The goal of this study was to evaluate the effects of P and K fertilization on total faunal and nematode faunal composition and richness in plant litter and soil for 360 days in an area reforested with Acacia auriculiformis (A. Cunn), located in the municipality of Conceição de Macabu in the State of Rio de Janeiro. For each treatment (fertilized and unfertilized plots), samples of litter and soil (to a depth of 5 cm) were collected and transferred into a Berlese-Tüllgren funnels for the extraction of fauna. Mesofauna and macrofauna were quantified, and the major taxa identified. Nematodes were extracted by centrifugal flotation in sucrose solution and identified according to feeding habits. Density (number of individuals m-2) of total fauna, microphages, social insects and saprophages varied significantly per treatment and sampling time in both litter and soil. The total number of individuals collected was 5,127, and the total number of nematodes 894. Phosphorus and potassium fertilization resulted in an increase in total fauna density and richness in the litter due to an increased abundance of social insects, saprophages and herbivores. In the soil, fertilization increased the saprophage and predator densities. Saprophages were the predominant taxa in the litter, while social insects (Formicidae) prevailed in the soil. Litter nematode populations were favored by mineral fertilization. Bacteriophages were the predominant nematode group in both litter and soil.
Resumo:
BACKGROUND: In an experimental setting, the performance of the LifeBox, a new portable extracorporeal membrane oxygenator (ECMO) system suitable for patient transport, is presented. Standard rectilinear percutaneous cannulae are normally employed for this purpose, but have limited flow and pressure delivery due to their rigid structure. Therefore, we aimed to determine the potential for flow increase by using self-expanding venous cannulae. METHODS: Veno-arterial bypass was established in three pigs (40.6+/-5.1 kg). The venous line of the cardiopulmonary bypass was established by cannulation of the external jugular vein. The arterial side of the circulation was secured by cannulation of the common carotid artery. Two different venous cannulae (SmartCanula 18/36F 430mm and Biomedicus 19F) were examined for their functional integrity when used in conjunction with the centrifugal pump (500-3000 RPM) of the LifeBox system. RESULTS: At 1500, 2000, 2500, and 3000 RPM, the blood flow increased steadily for each cannula, but remained higher in the self-expanding cannula. That is, the 19F rectilinear cannula achieved a blood flow of 0.93+/-0.14, 1.47+/-0.37, 1.9+/-0.68, and 1.5+/-0.9 l/min, respectively, and the 18/36F self-expanding cannula achieved 1.1+/-0.1, 1.9+/-0.33, 2.8+/-0.39 and 3.66+/-0.52 l/min. However, when tested for venous line pressure, the standard venous cannula achieved -29+/-10.7mmHg while the self-expanding cannula achieved -13.6 +/-4.3mmHg at 1500 RMP. As the RPM increased from 2500 to 3000, the venous line pressure accounted for -141.9+/-20 and -98+/-7.3mmHg for the 19F rectilinear cannula and -30.6+/-6.4 and -45+/-11.6mmHg for the self-expanding cannula. CONCLUSION: The self-expanding cannula exhibited superior venous drainage ability when compared to the performance of the standard rectilinear cannula with the use of the LifeBox. The flow rate achieved was approximately 40% greater than the standard drainage device, with a maximal pump flow recorded at 4.3l/min.
Resumo:
To develop the understanding of innovation processes conceptualized in terms of asso- ciation through the "sociology of translation" (cf. actor-network theory) studies, this article analyses innovation processes in terms of dissociation and detachment mechanisms, exami- ning innovation through "withdrawal;" that is, innovation based on reducing or withdrawing use of a practice-"subtracting," "detaching"-a given artefact. Specifically, it focuses on the shift to farming techniques that have eliminated ploughing, bringing to light four major mechanisms constitutive of dissociation: centrifugal association; making entities and asso- ciations visible; making other entities and associations invisible; bringing together or "asso- ciating" new entities. The study helps refine our understanding of the detachment processes at work in innovation, shedding light in this particular case on transfers between public research institutes, industrial companies, farmers and citizens seeking to develop new farm production models.
Resumo:
Direction-selective retinal ganglion cells show an increased activity evoked by light stimuli moving in the preferred direction. This selectivity is governed by direction-selective inhibition from starburst amacrine cells occurring during stimulus movement in the opposite or null direction. To understand the intrinsic membrane properties of starburst cells responsible for direction-selective GABA release, we performed whole-cell recordings from starburst cells in mouse retina. Voltage-clamp recordings revealed prominent voltage-dependent K+ currents. The currents were mostly blocked by 1 mm TEA, activated rapidly at voltages more positive than -20 mV, and deactivated quickly, properties reminiscent of the currents carried by the Kv3 subfamily of K+ channels. Immunoblots confirmed the presence of Kv3.1 and Kv3.2 proteins in retina and immunohistochemistry revealed their expression in starburst cell somata and dendrites. The Kv3-like current in starburst cells was absent in Kv3.1-Kv3.2 knock-out mice. Current-clamp recordings showed that the fast activation of the Kv3 channels provides a voltage-dependent shunt that limits depolarization of the soma to potentials more positive than -20 mV. This provides a mechanism likely to contribute to the electrical isolation of individual starburst cell dendrites, a property thought essential for direction selectivity. This function of Kv3 channels differs from that in other neurons where they facilitate high-frequency repetitive firing. Moreover, we found a gradient in the intensity of Kv3.1b immunolabeling favoring proximal regions of starburst cells. We hypothesize that this Kv3 channel gradient contributes to the preference for centrifugal signal flow in dendrites underlying direction-selective GABA release from starburst amacrine cells.
Resumo:
BACKGROUND: Recently, a compact cardiopulmonary support (CPS) system designed for quick set-up for example, during emergency cannulation, has been introduced. Traditional rectilinear percutaneous cannulas are standard for remote vascular access with the original design. The present study was designed to assess the potential of performance increase by the introduction of next-generation, self-expanding venous cannulas, which can take advantage of the luminal width of the venous vasculature despite a relatively small access orifice. METHODS: Veno-arterial bypass was established in three bovine experiments (69+/-10 kg). The Lifebridge (Lifebridge GmbH, Munich, Germany) system was connected to the right atrium in a trans-jugular fashion with various venous cannulas; and the oxygenated blood was returned through the carotid artery with a 17 F percutaneous cannula. Two different venous cannulas were studied, and the correlation between the centrifugal pump speed (1500-3900 RPM), flow and the required negative pressure on the venous side was established: (A) Biomedicus 19 F (Medtronic, Tolochenaz, Switzerland); (B) Smart canula 18 F/36 F (Smartcanula LLC, Lausanne, Switzerland). RESULTS: At 1500 RPM, the blood flow was 0.44+/-0.26 l min(-1) for the 19 F rectilinear cannula versus 0.73+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 2500 RPM the blood flow was 1.63+/-0.62 l min(-1) for the 19F rectilinear cannula versus 2.13+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 3500 RPM, the blood flow was 2.78+/-0.47 l min(-1) for the 19 F rectilinear cannula versus 3.64+/-0.39 l min(-1) for the 18/36 F self-expanding cannula (p<0.01 for 18/36 F vs 19 F). At 1500 RPM, the venous line pressure was 18+/-8 mmHg for the 19F rectilinear cannula versus 19+/-5 mmHg for the 18/36 F self-expanding cannula. At 2500 RPM the venous line pressure accounted for -22+/-32 mmHg for the 19 F rectilinear cannula versus 2+/-5 mmHg for the 18/36 F self-expanding cannula. At 3500 RPM, the venous line pressure was -112+/-42 mmHg for the rectilinear cannula versus 28+/-7 mmHg for the 18/36 F self-expanding cannula (p<0.01 for 18 F/36 F vs 19 F). Conclusions: The negative pressure required to achieve adequate venous drainage with the self-expanding venous cannula accounts for approximately 31% of the pressure necessary with the 19 F rectilinear cannula. In addition, a pump flow of more than 4 l min(-1) can be achieved with the self-expanding design and a well-accepted negative inlet pressure for minimal blood trauma of less than 50 mmHg.
Resumo:
The integration of electric motors and industrial appliances such as pumps, fans, and compressors is rapidly increasing. For instance, the integration of an electric motor and a centrifugal pump provides cost savings and improved performance characteristics. Material cost savings are achieved when an electric motor is integrated into the shaft of a centrifugal pump, and the motor utilizes the bearings of the pump. This arrangement leads to a smaller configuration that occupies less floor space. The performance characteristics of a pump drive can be improved by using the variable-speed technology. This enables the full speed control of the drive and the absence of a mechanical gearbox and couplers. When using rotational speeds higher than those that can be directly achieved by the network frequency the structure of the rotor has to be mechanically durable. In this thesis the performance characteristics of an axial-flux solid-rotor-core induction motor are determined. The motor studied is a one-rotor-one-stator axial-flux induction motor, and thus, there is only one air-gap between the rotor and the stator. The motor was designed for higher rotational speeds, and therefore a good mechanical strength of the solid-rotor-core rotor is required to withstand the mechanical stresses. The construction of the rotor and the high rotational speeds together produce a feature, which is not typical of traditional induction motors: the dominating loss component of the motor is the rotor eddy current loss. In the case of a typical industrial induction motor instead the dominating loss component is the stator copper loss. In this thesis, several methods to decrease the rotor eddy current losses in the case of axial-flux induction motors are presented. A prototype motor with 45 kW output power at 6000 min-1 was designed and constructed for ascertaining the results obtained from the numerical FEM calculations. In general, this thesis concentrates on the methods for improving the electromagnetic properties of an axial-flux solid-rotor-core induction motor and examines the methods for decreasing the harmonic eddy currents of the rotor. The target is to improve the efficiency of the motor and to reach the efficiency standard of the present-day industrial induction motors equipped with laminated rotors.
Resumo:
Tässä diplomityössä käsitellään erään tuotekehitysprojektissa tehdyn turbokoneen prototyypin takuumittauksia. Takuumittauksilla on tarkoitus varmistaa alustavasti valmistetun prototyypin toimivuus. Mittauksista saatuja arvoja on lopuksi tarkoitus verrata suunnitteluarvoihin, jolloin nähdäänkuinka hyvin suunnitelmat ja alustavat suunnittelulaskelmat ovat onnistuneet koskien tätä turbokonetta. Työssä esitellään pääpiirteissään laitteen toiminta. Takuumittauksia varten tarpeelli-set mitattavat suureet ja vaihtoehtoiset mittausmenetelmät on esitelty. Lisäksi on suunniteltu mittausjärjestelmä PI-kaavioineen, jolla pystytään saamaan riittävän kat-tava mittaustulos laajuus. Työssä on myös esitelty miten mittaustuloksista saadaan tarvittavat vertailuarvot verrattavaksi alustaviin suunnittelulaskelmiin. Tämä diplomityö on tehty, että alustavat mittaussuunnitelmat olisi valmiina olemassa jotta varsinainen takuumittauslaitteisto pystytään rakentamaan nopeasti turbokoneen prototyypin valmistuttua. Lopuksi saadun mittausotannan käsitteleminen on myös selvempää, koska riittävät teoreettiset perusteet mittausaineiston käsittelemiseen on myös kerätty tähän työhön. Työssä käsiteltävän mittausjärjestelmän pääpaino on virtaus ja lämpöteknisillä mitta-uksilla. Myös sähköteknisiä mittauksia ja turbokoneen rakenteellisen toimivuuden mittauksia on käsitelty tässä työssä. Tässä diplomityö antaa kattavat perustiedot tarvittaviin mittausmenetelmiin ja miten varsinainen mittaustieto saadaan jalostettua vertailtavaan muotoon. Siinä käsitellään myös vaikeuksia joita toimivanmittausjärjestelmän kehittämisessä on otettava huo-mioon.
Resumo:
Tämän diplomityön tavoitteena on kartoittaa Vaahto Oy:n Hollolan tehtaan energiankulutus ja energiansäästökohteet. Ensin tutkittiin tehtaan energiankulutus ja energiankulutuksen jakautuminen. Tutkimuksessa käytettiin saatavilla olevia kulutustietoja, luettiin konekirjoja sekä haastateltiin tehtaan työntekijöitä. Lisäksi tehdashallien lämmityslaitteiden hyötysuhteet mitattiin. Tutkimuksen päätavoite oli selvittää, miksi tehtaan lämmitysenergiankulutus on kasvanut ja kannattaisiko rakennusten lämmittämiseen käyttää vaihtoehtoista lämmitysmuotoa öljylämmitykselle. Potentiaalisista energiansäästökohteista tehtiin investointilaskelmat ja toimenpide-ehdotukset. Kannattaviksi toimenpiteiksi tutkimuksessa todettiin: lämmityspolttoaineen vaihtaminen maakaasuun, nosto-ovien hankkiminen, paineilmaverkon huolto, paineilmakompressorin lämmöntalteenotto, tehdastilojen sisälämpötilan tarkastus ja työnjohtotilojen ilmanvaihdon käyntiaikojen muutos. Toimenpiteillä arvioidaan vuotuisten energiakustannusten pienenevän noin 34 000 euroa. Toimenpiteiden toteuttamisen arvioidaan maksavan 135 000 ¤, mistä lämmitysjärjestelmän vaihdon osuus on 100 000 ¤.
Resumo:
Diplomityössä kehitetään malli tiheän kaksifaasivirtauksen aiheuttaman eroosiokulumi-sen mallintamiseksi, ratkaistaan virtauskenttä kahdessa erilaisessa keskipakopumpussa, sovelletaan kehitettyä mallia, sekävertaillaan mallin antamia tuloksia käytännön kokeissa saavutettuihin tuloksiin. Työssä on erityisenä mielenkiinnon kohteena savukaasupesurin pumppu. Työn alkuosa sisältää tarkemman kuvauksen savukaasupesurin toi-minnasta. Numeerinen ratkaisu ja laskentahilan generointi suoritetaan ANSYS CFX- ja Turbo-Grid-ohjelmistoilla. Laskennassa virtauksen Navier-Stokesin yhtälöt on aikakeskiarvo-tettu ja ratkaistu käyttäen kontrollitilavuusmenetelmää. Tiheiden kaksifaasivirtausten eroosiokulumista on mallinnettu tekijän kehittämällä mallilla, jonka käytännön toteutus-ta ei kuitenkaan saateta julkiseksi, koodin kehittämisessä käytetty teoria on kuitenkin esitetty työssä. Työn piirissä tehtiin myös kulumiskokeita Sulzer Pumps Finlandin Karhulan tehtailla, sekä vertailtiin simuloinnin tuloksia aikaisemmissa kokeissa saavutettuihin. Koejärjestelyt kuvataan työssä.
Resumo:
Suuritehoisissa pumppu- ja puhallinkäytöissä käytetään usein suurnopeusmoottoria,jota syötetään välijännitteellä. Suurjännitetaajuudenmuuttajat ovat kalliita, eikä niitä ole aina edes mahdollista valmistaa. Tutkimuksen kohteena on rinnakkaisilla pienjännitetaajuudenmuuttajilla toteutettu sähkökäyttö, jossa pienjännite nostetaan moniensiöisellä muuntajalla suurjännitteeksi (6,6 kV) ja syötetään edelleen kuormana olevalle suurnopeusmoottorille. Opinnäytetyössä tutkitaan moniensiöisen muuntajan syöttöä rinnakkaisilla taajuudenmuuttajilla sekä niiden aiheuttamia häiriöitä toisilleen. Työssä tutkitaan myös harmonisten yliaaltojen vaikutuksia muuntajan häviöihin ja magnetointiominaisuuksiin. Taajuudenmuuttajan lähtöjännite ja -virta suodatetaan sinisuotimella, jonka parametreja simuloidaan Simulink- ohjelmistolla. Tavoite on löytää optimaaliset parametrit taajuudenmuuttajanlähtösuotimelle käyrämuotojen ja suotimeen jäävän tehon suhteen. Työssä tarkasteltiin sinisuodinta, johon jää 3 prosenttia syöttöjännitteestä. LC-suodin kompensoi sähkökäytön loistehon lähes kokonaan, joten taajuudenmuuttajien antotehon kannalta suotimet ovat perusteltuja. Taajuudenmuuttajan näennäisteho putoaa 22 prosenttia, joten taajuudenmuuttajat voidaan vastaavasti mitoittaa pienemmiksi.
Resumo:
Työn tavoitteena oli kartoittaa Lappeenrannan sementtitehtaan paineilmajärjestelmä, tehdä järjestelmän kehittämissuunnitelma ja arvioida suunnitelman mukaisen investoinnin kannattavuus investointilaskelmilla. Kartoituksesta selviää paineilman hankinnan toteutus, järjestelmään kuuluvien laitteiden selvitys ja energiankulutus sekä jakeluverkon ja paineilman käytön kartoitus. Kartoituksen ja aineiston pohjalta laadittiin suunnitelma järjestelmän kehittämiseksi. Aineistoa kerättiin haastattelemalla laitetoimittajia sekä muiden sementtitehtaiden johtoa. Paineilman käyttöä tehostettiin ja tehtaan matalapaine- eli kuumailmaverkon osalta tehtiin suunnitelmat sen täydellisestä uusimisesta. Tehtaan korkeapaine- eli yleisilmaverkkoon päätettiin olla investoimatta työssä esiteltävien käytännön syiden vuoksi. Investoinnin taloudellinen kannattavuus arvioitiin työhön rakennetulla investointilaskentamallilla. Sen avulla laskettiin investoinnin kannattavuus annuiteettimenetelmällä. Laskelmien tulokseen liittyvä epävarmuus arvioitiin myös malliin rakennetulla herkkyysanalyysillä. Lisäksi mallilla vertailtiin investoinnin eri hankintavaihtoehtojen kannattavuutta. Investointi osoittautui kannattavaksi.