993 resultados para Cassia rugosa


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dopamine (DA) is known as a primary regulator of prolactin secretion (PRL) and angiotensin II (Ang II) has been recognized as one brain inhibitory factor of this secretion. In this work, estrogen-primed or unprimed ovariectornized rats were submitted to the microinjection of saline or Ang II after previous microinjection of saline or of da antagonist (haloperidol, sulpiride or SCH) both in the medial preoptic area (MPOA). Our study of these interactions has shown that 1) estrogen-induced PRL secretion is mediated by Ang II and da actions in the MPOA, i.e. very high plasma PRL would be prevented by inhibitory action of Ang II, while very low levels would be prevented in part by stimulatory action of da through D-2 receptors, 2) the inhibitory action of Ang II depends on estrogen and is mediated in part by inhibitory action of da through D, receptors and in other part by inhibition of stimulatory action of da through D2 receptors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The objective of this study was to histologically analyze the influence of the platelet-rich plasma (PRP) on bone healing in surgically created critical-size defects (CSD) in the calvaria of diabetic rats.Study design. A total of 20 diabetic rats were divided into 2 groups: C (control) and PRP. A 5-mm diameter CSD was created in the calvarium of each animal. In Group C, the defect was filled by blood clot only. In Group PRP, 0.35 mL of PRP was placed in the defects. All animals were humanely killed 30 days postoperatively. Histometric and histologic analyses were performed. Data were statistically analyzed (t test, P < .05).Results. No defect completely regenerated with bone. Group PRP had a statistically greater amount of bone formation than Group C (37.22% +/- 6.00% and 21.68% +/- 11.35%, respectively).Conclusion. PRP placed in the defects significantly enhanced bone healing in CSD in the calvaria of diabetic rats both qualitatively and quantitatively. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 72-78)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present retrospective study was to evaluate the influence of age and gender on upper and lower airway width and upper lip length. In this study, 390 lateral cephalograms were divided into 13 age groups (ranging from 6 to 18 years) and were analyzed. The inter-group differences were analyzed using a MANOVA (Multivariate Analysis of the Variance), and the intragroup differences were analyzed using an ANOVA (Analysis of the Variance) and Tukey's test. The results of the present study indicated that although the airway width and the upper lip length increased with age, the lower airway width exhibited variable growth between the ages of six and eighteen years. The airway width was significantly greater in females than males, whereas the upper airway width was similar between these two genders. The lip length was significantly shorter in females than males. The lower airway width and upper lip length were significantly different between males and females, whereas the upper airway width was similar for the genders. The upper airway width and upper lip exhibited incremental growth between the ages of six and eighteen years. The upper lip closely followed the growth pattern of the upper airway width; the growth plateaued between the ages of 6 and 9 years, increased from 9 to 16 years and plateaued from 16 to 18 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this in vivo study was to evaluate the performance of laser fluorescence (LF) comparing different cut-off limits for occlusal caries detection. One hundred and thirty first permanent molars were selected. Visual examination and LF assessments were performed independently. The extent of caries was assessed after operative intervention. New cut-off limits were established and compared with those proposed by the manufacturer and by Lussi et al. (Eur J Oral Sci 109:14-19, 2001). Similar sensitivity and higher specificity was found at D(2) (considering as disease only dentin caries) when the LF cut-off limits proposed by Lussi et al. and the new one were compared. At the D(3) threshold (considering as disease only deep dentin caries), no statistically significant difference among the cut-off limits for sensitivity was found. However, the new cut-off limits showed higher specificity. The LF device provided good ability to detect dentin caries lesions. Furthermore, the new cut-off limits and the values proposed by Lussi et al. could be suggested for the in vivo detection of occlusal caries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives:The aim of this in vitro study was to assess the inter- and intra-examiner reproducibility and the accuracy of the International Caries Detection and Assessment System-II (ICDAS-II) in detecting occlusal caries.Methods:One hundred and sixty-three molars were independently assessed twice by two experienced dentists using the 0- to 6-graded ICDAS-II. The teeth were histologically prepared and classified using two different histological systems [Ekstrand et al. (1997) Caries Research vol. 31, pp. 224-231; Lussi et al. (1999) Caries Research vol. 33, pp. 261-266] and assessed for caries extension. Sensitivity, specificity, accuracy and area under the ROC curve (A(z)) were obtained at D(2) and D(3) thresholds. Unweighted kappa coefficient was used to assess inter- and intra-examiner reproducibility.Results:For the Ekstrand et al. histological classification the sensitivity was 0.99 and 1.00, specificity 1.00 and 0.69 and accuracy 0.99 and 0.76 at D(2) and D(3), respectively. For the Lussi et al. histological classification the sensitivity was 0.91 and 0.75, specificity 0.47 and 0.62 and accuracy 0.86 and 0.68 at D(2) and D(3), respectively. The A(z) varied from 0.54 to 0.73. The inter- and intra-examiner kappa values were 0.51 and 0.58, respectively.Conclusions:ICDAS-II presented good reproducibility and accuracy in detecting occlusal caries, especially caries lesions in the outer half of the enamel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background.The prevalence of molar incisor hypomineralization (MIH) varies considerably around the world; however, few studies have examined MIH in South American countries.Objective.To evaluate the prevalence, severity, and clinical consequences of MIH in Brazilian children residing in rural and urban areas of the municipality of Botelhos, Minas Gerais, Brazil.Methods.Children aged 6 to 12 years (n = 918) with all four-first permanent molars erupted had these teeth evaluated according to the European Academy of Paediatric Dentistry (EAPD) criteria. The examinations were conducted by two previously trained examiners, and the dental impact caused by MIH was evaluated with the Decayed, Missing and Filled Teeth (DMFT) index (WHO).Results.Molar incisor hypomineralization was present in 19.8% of the 918 children, with a higher prevalence in rural areas. The majority of the defects presented were demarcated opacities without post-eruptive structural loss, which has been considered as mild defects. Children with MIH had higher DMFT values.Conclusion.Despite the high prevalence of MIH, the severity of the defects was mild. The results indicate a positive association between MIH and the presence of dental caries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to assess the influence of cleaning pits and fissures with on aluminum oxide air abrasion system on the detection of occlusal caries in primary teeth using laser fluorescence (LF) and visual examination. Methods. The sample comprised 65 pit and fissure sites on extracted primary teeth suspected to be carious. The sites were submitted to 2 visual examinations (examiner JAR) and 2 LF readings (examiner TMV). Next, the occlusal surfaces were air-abraded and re-examined thereafter using both methods. The teeth were sectioned, and the histological analysis of the sites with a stereoscopic magnifying lens at X32 magnification was used as the gold standard Results. Cohen's kappa statistic for LF and visual examination were, respectively, 0.282/0.884 before and 0.896/0.905 after air abrasion. LF showed a sensitivity of 0.28 increasing to 0.49 and 0 specificity of 0.50 increasing to 0.92. Visual examination showed sensitivity of 0.78 and specificity of 0.73. Both increased after air abrasion. Conclusion: The findings suggest that cleaning pits and fissures with aluminum oxide air abrasion increased the accuracy of LF and visual examination for detection of occlusal caries in primary teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the efficacy of the laser fluorescence (LF) device in detecting in vitro demineralization and remineralization of smooth surface caries-like lesions. Background Data: The early detection of smooth surface caries-like lesions is important to provide proper management of carious lesions, and allows monitoring of them over time. Also, some authors suggest that LF could be useful in monitoring the caries pathological process. Materials and Methods: Seventy-eight blocks of bovine teeth were obtained, and then submitted to artificial caries lesion induction and to a pH-cycling process. Superficial microhardness (SMH) and laser fluorescence analysis were performed at baseline, after induction of caries-like lesions, and after the pH-cycling regimen to promote remineralization. Results: Friedman's and multiple comparison tests were performed for all variables. SMH analysis showed significant differences (p < 0.05) between baseline (286.77 +/- 1.49 Vickers hardness number [VHN] units), before (38.48 +/- 0.85 VHN), and after remineralization (131.93 +/- 2.63 VHN). Baseline values for LF were extremely low (2.71 +/- 0.05), and a statistically significant difference was observed only after remineralization (3.61 +/- 0.08), as demonstrated by the increase in LF values. Conclusion: The LF device did not show efficacy for monitoring in vitro demineralization and remineralization of smooth enamel surfaces.