941 resultados para Calibrador de dose


Relevância:

20.00% 20.00%

Publicador:

Resumo:

20 patients with liver metastases from colorectal carcinoma undergoing laparotomy received 15-60 mg intravenously, either intact or fragments of, anti-carcinoembryonic antigen (anti-CEA) monoclonal antibodies labelled with 0.55-1.48 GBq (15-40 mCi) of 131I, 3-8 days prior to operation. The uptake measured per gram of metastases ranged from 0.33 to 6.6 x 10(-3%) of injected dose. Tumour to liver uptake ratios ranged from 2 to 33. The radiation dose, estimated in 6 patients (3 of each group), for an extrapolated dose of 3.7 GBq (100 mCi) of 131I ranged from 0.3 to 0.8 Gy in normal liver or spleen (an acceptable estimate for bone marrow radiation dose) and from 3.4 to 8.2 Gy to the hepatic metastases, indicating that probably other therapeutic modalities should be associated with radioimmunotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compositional random vectors are fundamental tools in the Bayesian analysis of categorical data.Many of the issues that are discussed with reference to the statistical analysis of compositionaldata have a natural counterpart in the construction of a Bayesian statistical model for categoricaldata.This note builds on the idea of cross-fertilization of the two areas recommended by Aitchison (1986)in his seminal book on compositional data. Particular emphasis is put on the problem of whatparameterization to use

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In this study we compared the immunogenicity of influenza vaccine administered intradermally to the standard intramuscular vaccination in lung transplant recipients. METHODS: Patients were randomized to receive the trivalent inactivated seasonal 2008-9 influenza vaccine containing either 6 μg (intradermal) or 15 μg (intramuscular) of hemagglutinin per viral strain. Immunogenicity was assessed by measurement of geometric mean titer of antibodies using the hemagglutination-inhibition (HI) assay. Vaccine response was defined as a 4-fold or higher increase of antibody titers to at least one vaccine antigen. RESULTS: Eighty-five patients received either the intradermal (n = 41) or intramuscular (n = 44) vaccine. Vaccine response was seen in 6 of 41 patients (14.6%) in the intradermal vs 8 of 43 (18.6%) in the intramuscular group (p = 0.77). Seroprotection (HI ≥1:32) was 39% for H1N1, 83% for H3N2 and 29% for B strain in the intradermal group vs 28% for H1N1, 98% for H3N2 and 58% for B strain in the intramuscular group (p = 0.36 for H1N1, p = 0.02 for H3N2, p < 0.01 for B). Mild adverse events were seen in 44% of patients in the intradermal group and 34% in the intramuscular group (p = 0.38). CONCLUSIONS: Immunogenicity of the 2008-9 influenza vaccine given intradermally or intramuscularly was overall poor in lung transplant recipients. Novel strategies for influenza vaccination in this population are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND. Either higher levels of initial DNA damage or lower levels of radiation-induced apoptosis in peripheral blood lymphocytes have been associated to increased risk for develop late radiation-induced toxicity. It has been recently published that these two predictive tests are inversely related. The aim of the present study was to investigate the combined role of both tests in relation to clinical radiation-induced toxicity in a set of breast cancer patients treated with high dose hyperfractionated radical radiotherapy. METHODS. Peripheral blood lymphocytes were taken from 26 consecutive patients with locally advanced breast carcinoma treated with high-dose hyperfractioned radical radiotherapy. Acute and late cutaneous and subcutaneous toxicity was evaluated using the Radiation Therapy Oncology Group morbidity scoring schema. The mean follow-up of survivors (n = 13) was 197.23 months. Radiosensitivity of lymphocytes was quantified as the initial number of DNA double-strand breaks induced per Gy and per DNA unit (200 Mbp). Radiation-induced apoptosis (RIA) at 1, 2 and 8 Gy was measured by flow cytometry using annexin V/propidium iodide. RESULTS. Mean DSB/Gy/DNA unit obtained was 1.70 ± 0.83 (range 0.63-4.08; median, 1.46). Radiation-induced apoptosis increased with radiation dose (median 12.36, 17.79 and 24.83 for 1, 2, and 8 Gy respectively). We observed that those "expected resistant patients" (DSB values lower than 1.78 DSB/Gy per 200 Mbp and RIA values over 9.58, 14.40 or 24.83 for 1, 2 and 8 Gy respectively) were at low risk of suffer severe subcutaneous late toxicity (HR 0.223, 95%CI 0.073-0.678, P = 0.008; HR 0.206, 95%CI 0.063-0.677, P = 0.009; HR 0.239, 95%CI 0.062-0.929, P = 0.039, for RIA at 1, 2 and 8 Gy respectively) in multivariate analysis. CONCLUSIONS. A radiation-resistant profile is proposed, where those patients who presented lower levels of initial DNA damage and higher levels of radiation induced apoptosis were at low risk of suffer severe subcutaneous late toxicity after clinical treatment at high radiation doses in our series. However, due to the small sample size, other prospective studies with higher number of patients are needed to validate these results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model of skin infection with Leishmania amazonensiswith low doses of parasites is compared to infection with high doses of L. amazonensis and low and high doses of Leishmania major. C57BL/6 mice were infected with 10³ or 10(6) parasites in the ear and the outcome of infection was assessed. The appearance of lesions in mice infected with 10³ parasites was delayed compared to mice infected with 10(6) Leishmania and parasites were detectable at the infection site before lesions became apparent. Mice infected with L. amazonensisdisplayed persistent lesions, whereas infection with L. major spontaneously healed in all groups, although lymphocytes persisted at the site of infection after healing. Macrophages persisted only in L. amazonensis-infected mice. High-dose L. amazonensis-infected mice produced lower levels of IFN-γ and TNF than mice infected with L. major. No correlation between the persistence of parasites and IL-10 levels and the production of nitric oxide or urea by macrophages was found. We conclude that infection with low doses of L. amazonensisin the dermis changes the course of infection by delaying the appearance of lesions. However, low-dose infection does not change the outcomes of susceptibility and cytokine production described for subcutaneous infection with high numbers of parasites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Data on which to base definitive recommendations on the doses and duration of therapy for genotype 3 HCV/HIV-coinfected patients are scarce. We evaluated the efficacy of a lower peginterferon-α 2a dose and a shorter duration of therapy than the current standard of care in genotype 3 HCV/HIV-coinfected patients. METHODS AND FINDINGS Pilot, open-label, single arm clinical trial which involved 58 Caucasian HCV/HIV-coinfected patients who received weekly 135 µg peginterferon-α 2a plus ribavirin 400 mg twice daily during 20 weeks after attaining undetectable viremia. The relationships between baseline patient-related variables, including IL28B genotype, plasma HCV-RNA, ribavirin dose/kg, peginterferon-α 2a and ribavirin levels with virological responses were analyzed. Only 4 patients showed lack of response and 5 patients dropped out due to adverse events related to the study medication. Overall, sustained virologic response (SVR) rates were 58.3% by intention-to-treat and 71.4% by per protocol analysis, respectively. Among patients with rapid virologic response (RVR), SVR and relapses rates were 92.6% and 7.4%, respectively. No relationships were observed between viral responses and ribavirin dose/kg, peginterferon-α 2a concentrations, ribavirin levels or rs129679860 genotype. CONCLUSIONS Weekly 135 µg pegIFN-α 2a could be as effective as the standard 180 µg dose, with a very low incidence of severe adverse events. A 24-week treatment duration appears to be appropriate in patients achieving RVR, but extending treatment up to just 20 weeks beyond negativization of viremia is associated with a high relapse rate in those patients not achieving RVR. There was no influence of IL28B genotype on the virological responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Cabazitaxel is approved in patients with metastatic hormone-refractory prostate cancer previously treated with a docetaxel-containing regimen. This study evaluated a weekly cabazitaxel dosing regimen. Primary objectives were to report dose-limiting toxicities (DLTs) and to determine the maximum tolerated dose (MTD). Efficacy, safety and pharmacokinetics were secondary objectives. METHODS Cabazitaxel was administered weekly (1-hour intravenous infusion at 1.5-12 mg/m2 doses) for the first 4 weeks of a 5-week cycle in patients with solid tumours. Monitoring of DLTs was used to determine the MTD and the recommended weekly dose. RESULTS Thirty-one patients were enrolled. Two of six patients experienced DLTs at 12 mg/m2, which was declared the MTD. Gastrointestinal disorders were the most common adverse event. Eight patients developed neutropenia (three ≥ Grade 3); one occurrence of febrile neutropenia was reported. There were two partial responses (in breast cancer) and 13 patients had stable disease (median duration of 3.3 months). Increases in Cmax and AUC0-t were dose proportional for the 6-12 mg/m2 doses. CONCLUSION The MTD of weekly cabazitaxel was 12 mg/m2 and the recommended weekly dose was 10 mg/m2. The observed safety profile and antitumour activity of cabazitaxel were consistent with those observed with other taxanes in similar dosing regimens. TRIAL REGISTRATION The study was registered with ClinicalTrials.gov as NCT01755390.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Unexplained fatigue is often left untreated or treated with antidepressants. This randomized, placebo-controlled, single-blinded study evaluated the efficacy and tolerability of single-dose intravenous ferric carboxymaltose (FCM) in iron-deficient, premenopausal women with symptomatic, unexplained fatigue. METHODS: Fatigued women (Piper Fatigue Scale [PFS] score ≥5) with iron deficiency (ferritin <50 µg/L and transferrin saturation <20%, or ferritin <15 µg/L) and normal or borderline hemoglobin (≥115 g/L) were enrolled in 21 sites in Austria, Germany, Sweden and Switzerland, blinded to the study drug and randomized (computer-generated randomization sequence) to a single FCM (1000 mg iron) or saline (placebo) infusion. Primary endpoint was the proportion of patients with reduced fatigue (≥1 point decrease in PFS score from baseline to Day 56). RESULTS: The full analysis included 290 women (FCM 144, placebo 146). Fatigue was reduced in 65.3% (FCM) and 52.7% (placebo) of patients (OR 1.68, 95%CI 1.05-2.70; p = 0.03). A 50% reduction of PFS score was achieved in 33.3% FCM- vs. 16.4% placebo-treated patients (p<0.001). At Day 56, all FCM-treated patients had hemoglobin levels ≥120 g/L (vs. 87% at baseline); with placebo, the proportion decreased from 86% to 81%. Mental quality-of-life (SF-12) and the cognitive function scores improved better with FCM. 'Power of attention' improved better in FCM-treated patients with ferritin <15 µg/L. Treatment-emergent adverse events (placebo 114, FCM 209; most frequently headache, nasopharyngitis, pyrexia and nausea) were mainly mild or moderate. CONCLUSION: A single infusion of FCM improved fatigue, mental quality-of-life, cognitive function and erythropoiesis in iron-deficient women with normal or borderline hemoglobin. Although more side effects were reported compared to placebo, FCM can be an effective alternative in patients who cannot tolerate or use oral iron, the common treatment of iron deficiency. Overall, the results support the hypothesis that iron deficiency can affect women's health, and a normal iron status should be maintained independent of hemoglobin levels. TRIAL REGISTRATION: ClinicalTrials.gov NCT01110356.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Iterative reconstruction (IR) techniques reduce image noise in multidetector computed tomography (MDCT) imaging. They can therefore be used to reduce radiation dose while maintaining diagnostic image quality nearly constant. However, CT manufacturers offer several strength levels of IR to choose from. PURPOSE: To determine the optimal strength level of IR in low-dose MDCT of the cervical spine. MATERIAL AND METHODS: Thirty consecutive patients investigated by low-dose cervical spine MDCT were prospectively studied. Raw data were reconstructed using filtered back-projection and sinogram-affirmed IR (SAFIRE, strength levels 1 to 5) techniques. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at C3-C4 and C6-C7 levels. Two radiologists independently and blindly evaluated various anatomical structures (both dense and soft tissues) using a 4-point scale. They also rated the overall diagnostic image quality using a 10-point scale. RESULTS: As IR strength levels increased, image noise decreased linearly, while SNR and CNR both increased linearly at C3-C4 and C6-C7 levels (P < 0.001). For the intervertebral discs, the content of neural foramina and dural sac, and for the ligaments, subjective image quality scores increased linearly with increasing IR strength level (P ≤ 0.03). Conversely, for the soft tissues and trabecular bone, the scores decreased linearly with increasing IR strength level (P < 0.001). Finally, the overall diagnostic image quality scores increased linearly with increasing IR strength level (P < 0.001). CONCLUSION: The optimal strength level of IR in low-dose cervical spine MDCT depends on the anatomical structure to be analyzed. For the intervertebral discs and the content of neural foramina, high strength levels of IR are recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of hypertension remains a difficult task despite the availability of different types of medications lowering blood pressure by different mechanisms. In order to reach the target blood pressures recommended today combination therapy is required in most patients. The co-administration of two drugs with different impacts on the cardiovascular system markedly increases the antihypertensive effectiveness without altering adversely tolerability. Fixed low-dose combinations are becoming a valuable option not only as second-line, but also as first-line therapy. In this respect the co-administration of thiazide diuretic with an AT(1)-receptor blocker is particularly appealing. The diuretic-induced decrease in total body sodium activates the renin-angiotensin system, thus rendering blood pressure maintenance angiotensin II-dependent. During blockade of the renin-angiotensin system low doses of thiazides generally suffice, allowing the prevention of undesirable metabolic effects. Also, blockade of the AT(1)-receptor, particularly when angiotensin II production is enhanced in response to diuretic therapy, is expected to be beneficial, since angiotensin II seems to contribute importantly to the pathogenesis of cardiovascular and renal complications of hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Au cours des deux dernières décennies, la technique d'imagerie arthro-scanner a bénéficié de nombreux progrès technologiques et représente aujourd'hui une excellente alternative à l'imagerie par résonance magnétique (IRM) et / ou arthro-IRM dans l'évaluation des pathologies de la hanche. Cependant, elle reste limitée par l'exposition aux rayonnements ionisants importante. Les techniques de reconstruction itérative (IR) ont récemment été mis en oeuvre avec succès en imagerie ; la littérature montre que l'utilisation ces dernières contribue à réduire la dose d'environ 40 à 55%, comparativement aux protocoles courants utilisant la rétroprojection filtrée (FBP), en scanner de rachis. A notre connaissance, l'utilisation de techniques IR en arthro-scanner de hanche n'a pas été évaluée jusqu'à présent. Le but de notre étude était d'évaluer l'impact de la technique ASIR (GE Healthcare) sur la qualité de l'image objective et subjective en arthro-scanner de hanche, et d'évaluer son potentiel en terme de réduction de dose. Pour cela, trente sept patients examinés par arthro-scanner de hanche ont été randomisés en trois groupes : dose standard (CTDIvol = 38,4 mGy) et deux groupes de dose réduite (CTDIvol = 24,6 ou 15,4 mGy). Les images ont été reconstruites en rétroprojection filtrée (FBP) puis en appliquant différents pourcentages croissants d'ASIR (30, 50, 70 et 90%). Le bruit et le rapport contraste sur bruit (CNR) ont été mesurés. Deux radiologues spécialisés en imagerie musculo-squelettique ont évalué de manière indépendante la qualité de l'image au niveau de plusieurs structures anatomiques en utilisant une échelle de quatre grades. Ils ont également évalué les lésions labrales et du cartilage articulaire. Les résultats révèlent que le bruit augmente (p = 0,0009) et le CNR diminue (p = 0,001) de manière significative lorsque la dose diminue. A l'inverse, le bruit diminue (p = 0,0001) et le contraste sur bruit augmente (p < 0,003) de manière significative lorsque le pourcentage d'ASIR augmente ; on trouve également une augmentation significative des scores de la qualité de l'image pour le labrum, le cartilage, l'os sous-chondral, la qualité de l'image globale (au dede ASIR 50%), ainsi que le bruit (p < 0,04), et une réduction significative pour l'os trabuculaire et les muscles (p < 0,03). Indépendamment du niveau de dose, il n'y a pas de différence significative pour la détection et la caractérisation des lésions labrales (n=24, p = 1) et des lésions cartilagineuses (n=40, p > 0,89) en fonction du pourcentage d'ASIR. Notre travail a permis de montrer que l'utilisation de plus de 50% d'ASIR permet de reduire de manière significative la dose d'irradiation reçue par le patient lors d'un arthro-scanner de hanche tout en maintenant une qualité d'image diagnostique comparable par rapport à un protocole de dose standard utilisant la rétroprojection filtrée.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction et objectif: Lors d'essais cliniques, le pharmacien est responsable de la préparation et de la dispensation des médicaments à évaluer. Un article récent a toutefois montré que les aspects pharmaceutiques liés au contrôle de la dose administrée in fine étaient souvent mal contrôlés. Il peut exister une différence entre la dose nominale fournie par le certificat d'analyse du fabricant et la dose réellement administrée au sujet, biais qui se reporte en cascade sur l'estimation des paramètres pharmaco¬cinétiques (PK), comme la clairance ou le volume de distribution. Ce travail visait à évaluer les biais entachant la quantité de médicament réellement injectée (iv/sc) aux volontaires d'un essai clinique étudiant la PK et la relation dose-réponse d'un nouveau produit biotechnologique. Méthode: La dose de médicament administrée lors de l'essai clinique (D) a été calculée de la manière suivante: D = C ? V - pertes. La concentration du produit (C; titre nominal du fabricant) a été vérifiée par immuno-essai. Le volume de médicament injecté (V) a été déterminé pour chaque injection par pesée (n=72), en utilisant la masse de la seringue avant et après injection et la densité du produit. Enfin, une analyse in vitro a permis d'évaluer les pertes liées à l'adsorption du produit dans les lignes de perfusion et de choisir le dispositif adéquat in vivo. Résultats: La concentration du médicament s'est révélée proche du titre nominal (96 ± 7%), et a été utilisée comme référence. Le volume injecté était quant à lui entaché d'un biais systématique par rapport à la valeur théorique correspondant à 0.03 mL pour la dose minimale (i.e. 75% du volume à injecter à cette dose). Une analyse complémentaire a montré que cela s'expliquait par une réaspiration partielle de la solution médica-menteuse avant le retrait de la seringue après injection sc, due à l'élasticité du piston. En iv, le biais était par contre provoqué par une réaspiration du soluté de perfusion co-administré. Enfin, la mesure des quantités de médicament récupérées après injection dans le dispositif de perfusion a démontré des pertes minimales par adsorption. Discussion-conclusion: Cette étude confirme l'existence de biais inversement corrélés au volume et à la concentration du médicament administré, pouvant provoquer des erreurs importantes sur les paramètres PK. Ce problème est négligé ou insuffisamment considéré dans les protocoles de Phase I et nécessiterait une planification rigoureuse. Les procédures opératoires devraient attirer l'attention sur ce point crucial.