215 resultados para BRAKING


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis develops and tests various transient and steady-state computational models such as direct numerical simulation (DNS), large eddy simulation (LES), filtered unsteady Reynolds-averaged Navier-Stokes (URANS) and steady Reynolds-averaged Navier-Stokes (RANS) with and without magnetic field to investigate turbulent flows in canonical as well as in the nozzle and mold geometries of the continuous casting process. The direct numerical simulations are first performed in channel, square and 2:1 aspect rectangular ducts to investigate the effect of magnetic field on turbulent flows. The rectangular duct is a more practical geometry for continuous casting nozzle and mold and has the option of applying magnetic field either perpendicular to broader side or shorter side. This work forms the part of a graphic processing unit (GPU) based CFD code (CU-FLOW) development for magnetohydrodynamic (MHD) turbulent flows. The DNS results revealed interesting effects of the magnetic field and its orientation on primary, secondary flows (instantaneous and mean), Reynolds stresses, turbulent kinetic energy (TKE) budgets, momentum budgets and frictional losses, besides providing DNS database for two-wall bounded square and rectangular duct MHD turbulent flows. Further, the low- and high-Reynolds number RANS models (k-ε and Reynolds stress models) are developed and tested with DNS databases for channel and square duct flows with and without magnetic field. The MHD sink terms in k- and ε-equations are implemented as proposed by Kenjereš and Hanjalić using a user defined function (UDF) in FLUENT. This work revealed varying accuracies of different RANS models at different levels. This work is useful for industry to understand the accuracies of these models, including continuous casting. After realizing the accuracy and computational cost of RANS models, the steady-state k-ε model is then combined with the particle image velocimetry (PIV) and impeller probe velocity measurements in a 1/3rd scale water model to study the flow quality coming out of the well- and mountain-bottom nozzles and the effect of stopper-rod misalignment on fluid flow. The mountain-bottom nozzle was found more prone to the longtime asymmetries and higher surface velocities. The left misalignment of stopper gave higher surface velocity on the right leading to significantly large number of vortices forming behind the nozzle on the left. Later, the transient and steady-state models such as LES, filtered URANS and steady RANS models are combined with ultrasonic Doppler velocimetry (UDV) measurements in a GaInSn model of typical continuous casting process. LES-CU-LOW is the fastest and the most accurate model owing to much finer mesh and a smaller timestep. This work provided a good understanding on the performance of these models. The behavior of instantaneous flows, Reynolds stresses and proper orthogonal decomposition (POD) analysis quantified the nozzle bottom swirl and its importance on the turbulent flow in the mold. Afterwards, the aforementioned work in GaInSn model is extended with electromagnetic braking (EMBr) to help optimize a ruler-type brake and its location for the continuous casting process. The magnetic field suppressed turbulence and promoted vortical structures with their axis aligned with the magnetic field suggesting tendency towards 2-d turbulence. The stronger magnetic field at the nozzle well and around the jet region created large scale and lower frequency flow behavior by suppressing nozzle bottom swirl and its front-back alternation. Based on this work, it is advised to avoid stronger magnetic field around jet and nozzle bottom to get more stable and less defect prone flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cranial cruciate ligament (CCL) deficiency is the leading cause of lameness affecting the stifle joints of large breed dogs, especially Labrador Retrievers. Although CCL disease has been studied extensively, its exact pathogenesis and the primary cause leading to CCL rupture remain controversial. However, weakening secondary to repetitive microtrauma is currently believed to cause the majority of CCL instabilities diagnosed in dogs. Techniques of gait analysis have become the most productive tools to investigate normal and pathological gait in human and veterinary subjects. The inverse dynamics analysis approach models the limb as a series of connected linkages and integrates morphometric data to yield information about the net joint moment, patterns of muscle power and joint reaction forces. The results of these studies have greatly advanced our understanding of the pathogenesis of joint diseases in humans. A muscular imbalance between the hamstring and quadriceps muscles has been suggested as a cause for anterior cruciate ligament rupture in female athletes. Based on these findings, neuromuscular training programs leading to a relative risk reduction of up to 80% has been designed. In spite of the cost and morbidity associated with CCL disease and its management, very few studies have focused on the inverse dynamics gait analysis of this condition in dogs. The general goals of this research were (1) to further define gait mechanism in Labrador Retrievers with and without CCL-deficiency, (2) to identify individual dogs that are susceptible to CCL disease, and (3) to characterize their gait. The mass, location of the center of mass (COM), and mass moment of inertia of hind limb segments were calculated using a noninvasive method based on computerized tomography of normal and CCL-deficient Labrador Retrievers. Regression models were developed to determine predictive equations to estimate body segment parameters on the basis of simple morphometric measurements, providing a basis for nonterminal studies of inverse dynamics of the hind limbs in Labrador Retrievers. Kinematic, ground reaction forces (GRF) and morphometric data were combined in an inverse dynamics approach to compute hock, stifle and hip net moments, powers and joint reaction forces (JRF) while trotting in normal, CCL-deficient or sound contralateral limbs. Reductions in joint moment, power, and loads observed in CCL-deficient limbs were interpreted as modifications adopted to reduce or avoid painful mobilization of the injured stifle joint. Lameness resulting from CCL disease affected predominantly reaction forces during the braking phase and the extension during push-off. Kinetics also identified a greater joint moment and power of the contralateral limbs compared with normal, particularly of the stifle extensor muscles group, which may correlate with the lameness observed, but also with the predisposition of contralateral limbs to CCL deficiency in dogs. For the first time, surface EMG patterns of major hind limb muscles during trotting gait of healthy Labrador Retrievers were characterized and compared with kinetic and kinematic data of the stifle joint. The use of surface EMG highlighted the co-contraction patterns of the muscles around the stifle joint, which were documented during transition periods between flexion and extension of the joint, but also during the flexion observed in the weight bearing phase. Identification of possible differences in EMG activation characteristics between healthy patients and dogs with or predisposed to orthopedic and neurological disease may help understanding the neuromuscular abnormality and gait mechanics of such disorders in the future. Conformation parameters, obtained from femoral and tibial radiographs, hind limb CT images, and dual-energy X-ray absorptiometry, of hind limbs predisposed to CCL deficiency were compared with the conformation parameters from hind limbs at low risk. A combination of tibial plateau angle and femoral anteversion angle measured on radiographs was determined optimal for discriminating predisposed and non-predisposed limbs for CCL disease in Labrador Retrievers using a receiver operating characteristic curve analysis method. In the future, the tibial plateau angle (TPA) and femoral anteversion angle (FAA) may be used to screen dogs suspected of being susceptible to CCL disease. Last, kinematics and kinetics across the hock, stifle and hip joints in Labrador Retrievers presumed to be at low risk based on their radiographic TPA and FAA were compared to gait data from dogs presumed to be predisposed to CCL disease for overground and treadmill trotting gait. For overground trials, extensor moment at the hock and energy generated around the hock and stifle joints were increased in predisposed limbs compared to non predisposed limbs. For treadmill trials, dogs qualified as predisposed to CCL disease held their stifle at a greater degree of flexion, extended their hock less, and generated more energy around the stifle joints while trotting on a treadmill compared with dogs at low risk. This characterization of the gait mechanics of Labrador Retrievers at low risk or predisposed to CCL disease may help developing and monitoring preventive exercise programs to decrease gastrocnemius dominance and strengthened the hamstring muscle group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction : Les nourrissons, vu la grande compliance de leur cage thoracique, doivent maintenir activement leur volume pulmonaire de fin d’expiration (VPFE). Ceci se fait par interruption précoce de l’expiration, et par le freinage expiratoire au niveau laryngé et par la persistance de la contraction des muscles inspiratoires. Chez les nourrissons ventilés mécaniquement, notre équipe a montré que le diaphragme est activé jusqu’à la fin de l’expiration (activité tonique). Il n’est pas clair si cette activité tonique diaphragmatique compense pour l’absence de freinage laryngé liée à l’intubation endotrachéale. Objectif : Notre objectif est de déterminer si l’activité tonique diaphragmatique persiste après l’extubation chez les nourrissons et si elle peut être observée chez les enfants plus âgés. Méthode : Ceci est une étude observationnelle longitudinale prospective de patients âgés de 1 semaine à 18 ans admis aux soins intensifs pédiatriques (SIP), ventilés mécaniquement pour >24 heures et avec consentement parental. L’activité électrique du diaphragme (AEdi) a été enregistrée à l’aide d’une sonde nasogastrique spécifique à 4 moments durant le séjour aux SIP : en phase aigüe, pré et post-extubation et au congé. L’AEdi a été analysée de façon semi-automatique. L’AEdi tonique a été définie comme l’AEdi durant le dernier quartile de l’expiration. Résultats : 55 patients avec un âge médian de 10 mois (écart interquartile: 1-48) ont été étudiés. Chez les nourrissons (<1an, n=28), l’AEdi tonique en pourcentage de l’activité inspiratoire était de 48% (30-56) en phase aigüe, 38% (25-44) pré-extubation, 28% (17-42) post-extubation et 33% (22-43) au congé des SIP (p<0.05, ANOVA, avec différence significative entre enregistrements 1 et 3-4). Aucun changement significatif n’a été observé pré et post-extubation. L’AEdi tonique chez les patients plus âgés (>1an, n=27) était négligeable en phases de respiration normale (0.6mcv). Par contre, une AEdi tonique significative (>1mcv et >10%) a été observée à au moins un moment durant le séjour de 10 (37%) patients. La bronchiolite est le seul facteur indépendant associé à l’activité tonique diaphragmatique. Conclusion : Chez les nourrissons, l’AEdi tonique persiste après l’extubation et elle peut être réactivée dans certaines situations pathologiques chez les enfants plus âgés. Elle semble être un indicateur de l’effort du patient pour maintenir son VPFE. D’autres études devraient être menées afin de déterminer si la surveillance de l’AEdi tonique pourrait faciliter la détection de situations de ventilation inappropriée.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction : Les nourrissons, vu la grande compliance de leur cage thoracique, doivent maintenir activement leur volume pulmonaire de fin d’expiration (VPFE). Ceci se fait par interruption précoce de l’expiration, et par le freinage expiratoire au niveau laryngé et par la persistance de la contraction des muscles inspiratoires. Chez les nourrissons ventilés mécaniquement, notre équipe a montré que le diaphragme est activé jusqu’à la fin de l’expiration (activité tonique). Il n’est pas clair si cette activité tonique diaphragmatique compense pour l’absence de freinage laryngé liée à l’intubation endotrachéale. Objectif : Notre objectif est de déterminer si l’activité tonique diaphragmatique persiste après l’extubation chez les nourrissons et si elle peut être observée chez les enfants plus âgés. Méthode : Ceci est une étude observationnelle longitudinale prospective de patients âgés de 1 semaine à 18 ans admis aux soins intensifs pédiatriques (SIP), ventilés mécaniquement pour >24 heures et avec consentement parental. L’activité électrique du diaphragme (AEdi) a été enregistrée à l’aide d’une sonde nasogastrique spécifique à 4 moments durant le séjour aux SIP : en phase aigüe, pré et post-extubation et au congé. L’AEdi a été analysée de façon semi-automatique. L’AEdi tonique a été définie comme l’AEdi durant le dernier quartile de l’expiration. Résultats : 55 patients avec un âge médian de 10 mois (écart interquartile: 1-48) ont été étudiés. Chez les nourrissons (<1an, n=28), l’AEdi tonique en pourcentage de l’activité inspiratoire était de 48% (30-56) en phase aigüe, 38% (25-44) pré-extubation, 28% (17-42) post-extubation et 33% (22-43) au congé des SIP (p<0.05, ANOVA, avec différence significative entre enregistrements 1 et 3-4). Aucun changement significatif n’a été observé pré et post-extubation. L’AEdi tonique chez les patients plus âgés (>1an, n=27) était négligeable en phases de respiration normale (0.6mcv). Par contre, une AEdi tonique significative (>1mcv et >10%) a été observée à au moins un moment durant le séjour de 10 (37%) patients. La bronchiolite est le seul facteur indépendant associé à l’activité tonique diaphragmatique. Conclusion : Chez les nourrissons, l’AEdi tonique persiste après l’extubation et elle peut être réactivée dans certaines situations pathologiques chez les enfants plus âgés. Elle semble être un indicateur de l’effort du patient pour maintenir son VPFE. D’autres études devraient être menées afin de déterminer si la surveillance de l’AEdi tonique pourrait faciliter la détection de situations de ventilation inappropriée.