914 resultados para Angle of rotation


Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To investigate how distance visual acuity in the presence of defocus and astigmatism is affected by age and whether aberration properties of young and older eyes can explain any differences. METHODS: Participants were 12 young adults (mean [±SD] age, 23 [±2] years) and 10 older adults (mean [±SD] age, 57 [±4] years). Cyclopleged right eyes were used with 4-mm effective pupil sizes. Thirteen blur conditions were used by adding five spherical lens conditions (-1.00 diopters [D], -0.50 D, plano/0.00 D, +0.50 D, and +1.00 D) and adding two cross-cylindrical lenses (+0.50 DS/-1.00 DC and +1.00 D/-2.00 DC, or 0.50 D and 1.00 D astigmatism) at four negative cylinder axes (45, 90, 135, and 180 degrees). Targets were single lines of high-contrast letters based on the Bailey-Lovie chart. Successively smaller lines were read until a participant could no longer read any of the letters correctly. Aberrations were measured with a COAS-HD Hartmann-Shack aberrometer. RESULTS: There were no significant differences between the two age groups. We estimated that 70 to 80 participants per group would be needed to show significant effects of the trend of greater visual acuity loss for the young group. Visual acuity loss for astigmatism was twice that for defocus of the same magnitude of blur strength (0.33 logMAR [logarithm of the minimum angle of resolution]/D compared with 0.18 logMAR/D), contrary to the geometric prediction of similar loss. CONCLUSIONS: Any age-related differences in visual acuity in the presence of defocus and astigmatism were swamped by interparticipant variation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyondd max and to find ways to mitigate this dependence for measurements in phantoms. Methods Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam (“edge on,” 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. Results For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al2O3) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusions The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinicalin vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Asymmetric tri-bridged diruthenium(III) complexes, [Ru2O(O(2)CR)(3)(en) (PPh(3))(2)](ClO4) (R = C6H4-p-X: X = OMe (1a), Me (1b); en=1,2-diaminoethane), were prepared and structurally characterized. Complex 1a 3CHCl(3), crystallizes in the triclinic space group P (1) over bar with a = 14.029(5), b = 14.205(5), c = 20.610(6) Angstrom, alpha= 107.26(3), beta = 101.84(3), gamma= 97.57(3)degrees, V= 3756(2) Angstrom(3) and Z = 2. The complex has an {Ru-2(mu-O)(mu-O(2)CR)(2)(2+)} core and exhibits [O4PRu(mu-O)RuPO2N2](+) coordination environments for the metal centers. The novel structural feature is the asymmetric arrangement of ligands at the terminal sites of the core which shows an Ru... Ru separation of 3.226(3) Angstrom and an Ru-O-Ru angle of 119.2(5)degrees. An intense visible band observed near 570 nm is assigned to a charge transfer transition involving the d pi-Ru(III) and p pi-mu-O Orbitals. Cyclic voltammetry of the complexes displays a reversible Ru-2(III,III) reversible arrow Ru-2(III,IV) couple near 0.8 V (versus SCE) in MeCN-0.1 M TBAP.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The undesirable effects of roll motion of ships (rocking about the longitudinal axis) became noticeable in the mid-nineteenth century when significant changes were introduced to the design of ships as a result of sails being replaced by steam engines and the arrangement being changed from broad to narrow hulls. The combination of these changes led to lower transverse stability (lower restoring moment for a given angle of roll) with the consequence of larger roll motion. The increase in roll motion and its effect on cargo and human performance lead to the development several control devices that aimed at reducing and controlling roll motion. The control devices most commonly used today are fin stabilizers, rudder, anti-roll tanks, and gyrostabilizers. The use of different types of actuators for control of ship roll motion has been amply demonstrated for over 100 years. Performance, however, can still fall short of expectations because of difficulties associated with control system design, which have proven to be far from trivial due to fundamental performance limitations and large variations of the spectral characteristics of wave-induced roll motion. This short article provides an overview of the fundamentals of control design for ship roll motion reduction. The overview is limited to the most common control devices.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

M r= 470.46, rhombohedral, R3, a =8.710(4)A, a=91.10(3) o, V= 660.4 (9) A 3, Z= 1,D m= 1.170 (flotation in KI solution), D x=1.183 Mg m -a, Mo Kct, 2 = 0.7107/~,, /t =0.033 mm -1, F(000) - 248.0, T= 293 K, R -- 4.6%(481 unique reflections). The molecule has C a symmetry and is propeller shaped, the angle of twist about the B-C bond being 41.5 (7) °. The space group being chiral, this is yet another example of spontaneous resolution. The results of a thermal-motion analysis are discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Crystals growing from solution, the vapour phase and from supercooled melt exhibit, as a rule, planar faces. The geometry and distribution of dislocations present within the crystals thus grown are strongly related to the growth on planar faces and to the different growth sectors rather than the physical properties of the crystals and the growth methods employed. As a result, many features of generation and geometrical arrangement of defects are common to extremely different crystal species. In this paper these commoner aspects of dislocation generation and configuration which permits one to predict their nature and distribution are discussed. For the purpose of imaging the defects a very versatile and widely applicable technique viz. x-ray diffraction topography is used. Growth dislocations in solution grown crystals follow straight path with strongly defined directions. These preferred directions which in most cases lie within an angle of ±15° to the growth normal depend on the growth direction and on the Burger's vector involved. The potential configuration of dislocations in the growing crystals can be evaluated using the theory developed by Klapper which is based on linear anisotropic elastic theory. The preferred line direction of a particular dislocation corresponds to that in which the dislocation energy per unit growth length is a minimum. The line direction analysis based on this theory enables one to characterise dislocations propagating in a growing crystal. A combined theoretical analysis and experimental investigation based on the above theory is presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The non-linear equations of motion of a rotating blade undergoing extensional and flapwise bending vibration are derived, including non-linearities up to O (ε3). The strain-displacement relationship derived is compared with expressions derived by earlier investigators and the errors and the approximations made in some of those are brought out. The equations of motion are solved under the inextensionality condition to obtain the influence of the amplitude on the fundamental flapwise natural frequency of the rotating blade. It is found that large finite amplitudes have a softening effect on the flapwise frequency and that this influence becomes stronger at higher speeds of rotation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Both the semi-similar and self-similar flows due to a viscous fluid rotating with time dependent angular velocity over a porous disk of large radius at rest with or without a magnetic field are investigated. For the self-similar case the resulting equations for the suction and no mass transfer cases are solved numerically by quasilinearization method whereas for the semi-similar case and injection in the self-similar case an implicit finite difference method with Newton's linearization is employed. For rapid deceleration of fluid and for moderate suction in the case of self-similar flow there exists a layer of fluid, close to the disk surface where the sense of rotation is opposite to that of the fluid rotating far away. The velocity profiles in the absence of magnetic field are found to be oscillatory except for suction. For the accelerating freestream, (semi-similar flow) the effect of time is to reduce the amplitude of the oscillations of the velocity components. On the other hand the effect of time for the oscillating case is just the opposite.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thioacetamide has a dipole moment substantially higher than the vector sum of the normal characteristic moments of its constituent bonds. However, the effect can reasonably be accounted for on the scheme of alterations in charge distribution and hence of bond moments proposed by Smith, Ree, Magee and Eyring. The same is probably true for chloroacetamide even though the problem of rotation about the C-C single bond renders the conclusion less certain. For cyanoacetamide, the observed moment cannot be accounted for satisfactorily on this basis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A modified conventional direct shear device was used to measure unsaturated shear strength of two silty soils at low suction values (0 ~ 50 kPa) that were achieved by following drying and wetting paths of soil water characteristic curves (SWCCs). The results revealed that the internal friction angle of the soils was not significantly affected by either the suction or the drying wetting SWCCs. The apparent cohesion of soil increased with a decreasing rate as suction increased. Shear stress-shear displacement curves obtained from soil specimens subjected to the same net normal stress and different suction values showed a higher initial stiffness and a greater peak stress as suction increased. A soil in wetting exhibited slightly higher peak shear stress and more contractive volume change behavior than that of soil in drying at the same net normal stress and suction.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Experimental results pertaining to the initiation, dynamics and mechanism of cavitation erosion on poly(methyl methacrylate) specimens tested in a rotating disk device are described in detail. Erosion normally starts at the location nearest to the center of rotation (CR). As the exposure time to cavitation increases, additional erosion areas or sites appear away from the CR and secondary erosion (induced by eroded pits) spreads upstream and merges with the main pit. The microcracks increase in density towards the end of the incubation period and transform into macrocracks in most cases. A study of light optical photographs and scanning electron micrographs of the eroded area shows that material particles are removed from the network of cracks because of crack joining and pits indicate particle debris. Optical degradation (loss of transmittance) is observed to be greater on the back of the specimen than on the front.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

M r = 438.45, trigonal, P32, a = b = 13.385 (4), c = 9.900 (5) A,, V = 1536.0 A 3, Z = 3, D x = 1.42, D m = 1.42 Mg m -3, 2(Cu Ka) = 1.5418 A,,g(CuKa) = .800mm -], T=290K, F(000)=690, R=6.0% for 1222 unique reflections with F o>_2o(Fo). This is the first 2',3'-O-isopropylidene pyrimidine nucleoside with the base in a syn orientation with respect to the ribose [Xcy= 116.0(7)°]. The ribose has a C(3')-endo conformation with the phase angle of pseudorotation P = 16.36 (2) °. The dioxolane ring assumes an envelope conformation with 0(2') displaced from the best four-atom plane by 0.50 (1) k. The crystal structure is possibly stabilized by a bifurcated hydrogen bond between N(3) and the 0(2) and 0(4) atoms of screw-related molecules.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Traction is recognised as an important component of the overall playability and safety of a sportsfield. It relates to the "grip", or footing, provided through an athlete's shoe when in contact with the surface, and is normally measured by the torque generated when a weighted studded disc apparatus is dropped onto the turf and twisted manually. This paper describes the development of an automated traction tester, which mechanises the dropping and twisting of the weighted studded disc. By standardising these operational stages, more repeatable and reliable results can be expected than from the original hand-operated design where positioning of the disc and speed of rotation are controlled manually and so can vary from one measurement to the next. As well as measuring the maximum torque reached during rotation of the studded disc, the automated traction tester generates a profile of torque showing changes over time and calculates the angle through which the studded disc moved before reaching maximum torque. These aspects are now covered by a utility patent (PAT/AU/2004270767). Use of the automated traction tester is illustrated by comparative data for a range of warm-season turfgrasses, by comparisons of traction under different surface conditions generated by wear on Cynodon dactylon cultivars, and by the effects of environment, management and playing patterns on traction across a multi-use sports stadium.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A blunt-nosed hypersonic missile mounted with a forward-facing cavity is a good alternative to reduce the stagnation heating rates. The effects of a forward-racing cavity on heat transfer and aerodynamic coefficients are addressed in this paper. Tests were carried out in hypersonic shock tunnel HST2, at a hypersonic Mach number of 8 using a 41 deg apex-angle blunt cone. The aerodynamic forces on the test model with and without a forward-facing cavity at various angles of attack are measured by using an internally mountable accelerometer force balance system. Heat flux measurements have been carried out on the test model with and without a forward-facing cavity of the entire surface at zero degree angle of attack with platinum sensors. A numerical simulation was also carried out using the computational fluid dynamics code (CFX-Ansys 5.7). An important result of this study is that the smaller cavity diameter has the highest lift-to-drag ratio, whereas the medium cavity has the highest heat flux reduction. Theshock structure around the test model has also been visualized using the Schlieren flow visualization technique. The visualized shock structure and the measured aerodynamic forces on the missile-shaped body with cavity configurations agree well with the axisymmetric numerical simulations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Three oxo-bridged diiron(III) complexes of L-histidine and heterocyclic bases [Fe-2(mu-O)(L-his)(2)(B)(2)](ClO4)(2) (1-3), where B is 2,2'-bipyridine (bpy),1,10-phenanthroline (phen), dipyrido[3,2-d:2',3'-f]quinoxaline (dpq), were prepared and characterized. The bpy complex 1 was structurally characterized by X-ray crystallography. The molecular structure showed a {Fe-2(mu-O)} core in which iron(III) in a FeN4O2 coordination is bound to tridentate monoanionic L-histidine and bidentate bpy ligands. The Fe center dot center dot center dot Fe distance is similar to 3.5 angstrom. The Fe-O-Fe unit is essentially linear, giving a bond angle of similar to 172 degrees. The complexes showed irreversible cyclic voltammetric cathodic response near -0.1 V vs. SCE in H2O-0.1 M KCl. The binuclear units displayed antiferromagnetic interaction between two high-spin (S = 5/2) iron(III) centers giving a -J value of -110 cm(-1). The complexes showed good DNA binding propensity giving a binding constant value of similar to 10(5) M-1. Isothermal titration calorimetric data indicated single binding mode to the DNA. The binding was found to be driven by negative free energy change and enthalpy. The dpq complex 3 showed oxidative double-strand DNA cleavage on exposure to UV-A and visible light. The phen complex 2 displayed single-strand photocleavage of DNA. The DNA double-strand breaks were rationalized from theoretical molecular docking calculations. Mechanistic investigations showed formation of hydroxyl radicals as the reactive species through photodecarboxylation of the L-histidine ligand. The complexes exhibited good binding propensity to bovine serum albumin (BSA) protein in Tris-HCl/NaCl buffer medium. The dpq complex 3 showed UV-A light-induced site-specific oxidative BSA cleavage forming fragments of similar to 45 kDa and similar to 20 kDa molecular weights via SOH pathway.