951 resultados para Air quality Standards Australia
Resumo:
Mode of access: Internet.
Resumo:
Swine production represents an important segment of Brazilian economy, and the possibility of increasing production is eminent mainly if considered the low pork consumption when compared to other meat and the consumption of other countries. The increasing need in the international market demands show that in a near future the commercial barriers will be based on welfare, in the protection of the environment as well as in the worker's legislation. Little knowledge is available in the subject of worker's standards in the environmental agents in rural activities as well as the air quality under Brazilian conditions. The objectives of this research were to apply the main used standards related to noise and gases and to estimate occupational risk using measurements of noise level, hydrogen sulfide, methane and oxygen in swine housing, in piglet's nursery and finishing. The results showed that the continuous noise level were below the one found in the standards, however there were observed differences (P < 0.05) in relation to the noise level measured in piglet's nursing cages and in semi-slatted floor. The respective concentrations of hydrogen sulfide and methane were less than 1 ppm and less than 0,1% by volume, which was lower than the recommended limits in NR-15, CIGR and ACGIH. The oxygen level was 21% in average.
Resumo:
Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency's technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.
Resumo:
Background: Since establishing universal free access to antiretroviral therapy in 1996, the Brazilian Health System has increased the number of centers providing HIV/AIDS outpatient care from 33 to 540. There had been no formal monitoring of the quality of these services until a survey of 336 AIDS health centers across 7 Brazilian states was undertaken in 2002. Managers of the services were asked to assess their clinics according to parameters of service inputs and service delivery processes. This report analyzes the survey results and identifies predictors of the overall quality of service delivery. Methods: The survey involved completion of a multiple-choice questionnaire comprising 107 parameters of service inputs and processes of delivering care, with responses assessed according to their likely impact on service quality using a 3-point scale. K-means clustering was used to group these services according to their scored responses. Logistic regression analysis was performed to identify predictors of high service quality. Results: The questionnaire was completed by 95.8% (322) of the managers of the sites surveyed. Most sites scored about 50% of the benchmark expectation. K-means clustering analysis identified four quality levels within which services could be grouped: 76 services (24%) were classed as level 1 (best), 53 (16%) as level 2 (medium), 113 (35%) as level 3 (poor), and 80 (25%) as level 4 (very poor). Parameters of service delivery processes were more important than those relating to service inputs for determining the quality classification. Predictors of quality services included larger care sites, specialization for HIV/AIDS, and location within large municipalities. Conclusion: The survey demonstrated highly variable levels of HIV/AIDS service quality across the sites. Many sites were found to have deficiencies in the processes of service delivery processes that could benefit from quality improvement initiatives. These findings could have implications for how HIV/AIDS services are planned in Brazil to achieve quality standards, such as for where service sites should be located, their size and staffing requirements. A set of service delivery indicators has been identified that could be used for routine monitoring of HIV/AIDS service delivery for HIV/AIDS in Brazil (and potentially in other similar settings).
Resumo:
We analyzed the impact of chronic exposure to urban air pollution on the development of atherosclerosis. Hyperlipemic mice (LDLR(-/-)) were submitted to a high fat diet and air pollution for four months. We measured the susceptibility of LDL to oxidative modifications (TBARS), the presence of anti-oxLDL and an apoB-derived peptide (apoB-D) in blood and the degree of atherosclerosis in the aortic arch. Air pollution increased the susceptibility of LDL to oxidation as well as anti-oxLDL and anti-apo-B levels. These levels were even higher than in mice submitted to a high fat diet and non-polluted air. The lipid content of the atherosclerotic plaques in the aorta was increased in groups with a high cholesterol diet independently of the air quality. However, the thickness of the arterial wall was greater in mice fed a high lipid diet with polluted air. Thus, we conclude that urban air pollution exacerbates the susceptibility of LDL to oxidation, atherogenesis and vascular remodeling in hyperlipemic mice and that an immune response accompanies this process. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.
Resumo:
Lisbon is the largest urban area in the Western European coast. Due to this geographical position the Atlantic Ocean serves as an important source of particles and plays an important role in many atmospheric processes. The main objectives of this study were to (1) perform a chemical characterization of particulate matter (PM2.5) sampled in Lisbon, (2) identify the main sources of particles, (3) determine PM contribution to this urban area, and (4) assess the impact of maritime air mass trajectories on concentration and composition of respirable PM sampled in Lisbon. During 2007, PM2.5 was collected on a daily basis in the center of Lisbon with a Partisol sampler. The exposed Teflon filters were measured by gravimetry and cut into two parts: one for analysis by instrumental neutron activation analysis (INAA) and the other by ion chromatography (IC). Principal component analysis (PCA) and multilinear regression analysis (MLRA) were used to identify possible sources of PM2.5 and determine mass contribution. Five main groups of sources were identified: secondary aerosols, traffic, calcium, soil, and sea. Four-day backtracking trajectories ending in Lisbon at the starting sampling time were calculated using the HYSPLIT model. Results showed that maritime transport scenarios were frequent. These episodes were characterized by a significant decrease of anthropogenic aerosol concentrations and exerted a significant role on air quality in this urban area.
Resumo:
This study aimed to characterize air pollution and the associated carcinogenic risks of polycyclic aromatic hydrocarbon (PAHs) at an urban site, to identify possible emission sources of PAHs using several statistical methodologies, and to analyze the influence of other air pollutants and meteorological variables on PAH concentrations.The air quality and meteorological data were collected in Oporto, the second largest city of Portugal. Eighteen PAHs (the 16 PAHs considered by United States Environment Protection Agency (USEPA) as priority pollutants, dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were collected daily for 24 h in air (gas phase and in particles) during 40 consecutive days in November and December 2008 by constant low-flow samplers and using polytetrafluoroethylene (PTFE) membrane filters for particulate (PM10 and PM2.5 bound) PAHs and pre-cleaned polyurethane foam plugs for gaseous compounds. The other monitored air pollutants were SO2, PM10, NO2, CO, and O3; the meteorological variables were temperature, relative humidity, wind speed, total precipitation, and solar radiation. Benzo[a]pyrene reached a mean concentration of 2.02 ngm−3, surpassing the EU annual limit value. The target carcinogenic risks were equal than the health-based guideline level set by USEPA (10−6) at the studied site, with the cancer risks of eight PAHs reaching senior levels of 9.98×10−7 in PM10 and 1.06×10−6 in air. The applied statistical methods, correlation matrix, cluster analysis, and principal component analysis, were in agreement in the grouping of the PAHs. The groups were formed according to their chemical structure (number of rings), phase distribution, and emission sources. PAH diagnostic ratios were also calculated to evaluate the main emission sources. Diesel vehicular emissions were the major source of PAHs at the studied site. Besides that source, emissions from residential heating and oil refinery were identified to contribute to PAH levels at the respective area. Additionally, principal component regression indicated that SO2, NO2, PM10, CO, and solar radiation had positive correlation with PAHs concentrations, while O3, temperature, relative humidity, and wind speed were negatively correlated.
Resumo:
A Qualidade do Ar Interior (QAI) é um fator de grande preocupação. A importância de manter um ambiente salubre é mais acentuada em estabelecimentos escolares (EE), tendo em conta, que no interior destes permanecem crianças durante um elevado período de tempo. É fundamental garantir uma boa QAI nos edifícios escolares, de forma a salvaguardar a saúde, o bem-estar e o conforto dos ocupantes, bem como, não comprometer o seu desempenho escolar. Recentemente, foram construídos novos edifícios escolares e alguns dos existentes foram alvo de obras de remodelação. Contudo, a crescente tendência em construir edifícios cada vez mais herméticos, com vista à diminuição dos gastos de energia, origina problemas como a reduzida ventilação dos espaços. Vários estudos têm demonstrado a influência das atividades de limpeza na QAI. No entanto, verifica-se que na maioria das escolas não existem ainda procedimentos de limpeza padronizados. A falta de instruções de trabalho e a ausência de formação às assistentes operacionais pode comprometer a eficácia dos procedimentos de higienização, o que poderá ter influência na QAI dos espaços. Este estudo teve como principal objetivo avaliar a QAI em escolas básicas de 1.º ciclo. Foram contemplados no estudo fatores como a tipologia do edifício, a ocupação das salas e as atividades de limpeza. Procedeu-se à caracterização dos EE e à monitorização de parâmetros ambientais, como a temperatura do ar, a humidade relativa, a velocidade do ar, o dióxido de carbono, o monóxido de carbono, as partículas, os microrganismos mesófilos totais e os fungos. Estes parâmetros foram avaliados nas salas com ocupação, sem ocupação e durante a implementação de um plano de higienização. A ventilação inadequada parece ser o fator que mais condiciona a QAI das salas de aula avaliadas. Registaram-se elevadas concentrações de dióxido de carbono e de microrganismos mesófilos totais, que parecem estar relacionados com a permanência dos ocupantes nos locais e com a falta de ventilação adequada dos espaços. A concentração de dióxido de carbono foi mais elevada em edifícios recentes. Os picos elevados na concentração de partículas parecem estar associados com as atividades dos ocupantes. Obtiveram-se concentrações menores de fungos e de microrganismos mesófilos totais ao longo da implementação do plano de higienização, o que poderá significar que os procedimentos de limpeza contribuem para reduzir os níveis de contaminação dos espaços interiores. No entanto, tendo em conta, que a concentração de microrganismos mesófilos totais permaneceu elevada, as operações de limpeza parecem não ser suficientes para garantir uma boa QAI. O aumento da ventilação dos espaços poderia contribuir significativamente para a melhoria da QAI dos espaços avaliados.
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
Aims: The main aims of this work were the study of cork slabs moulds colonization and the evaluation of the moulds diversity during cork processing steps, in different cork stoppers factories. Simultaneously, it was envisaged to perform an evaluation of the air quality. Methods and Results: Moulds were isolated and identified from cork slabs and cork samples in four cork stoppers factories. The identification was based on morphological characters and microscopic observation of the reproductive structures. Airborne spore dispersion was assessed using a two stage Andersen sampler. It was observed that Chrysonilia sitophila was always present on cork slabs during the maturing period, but mould diversity appeared to be associated to the different factory configurations and processing steps. Conclusions: Spatial separation of the different steps of the process, including physical separation of the maturation step, is essential to guarantee high air quality and appropriate cork slabs colonization, i.e. C. sitophila dominance. The sorting and cutting of the edges of cork slabs after boiling and before the maturing step is also recommended. Significance and Impact of the Study: This study is very important for the cork stopper industry as it gives clear indications on how to keep high quality manufacturing standards and how to avoid occupational health problems.
Resumo:
Aims: The main aims of this work were the study of cork slabs moulds colonization and the evaluation of the moulds diversity during cork processing steps, in different cork stoppers factories. Simultaneously, it was envisaged to perform an evaluation of the air quality. Methods and Results: Moulds were isolated and identified from cork slabs and cork samples in four cork stoppers factories. The identification was based on morphological characters and microscopic observation of the reproductive structures. Airborne spore dispersion was assessed using a two stage Andersen sampler. It was observed that Chrysonilia sitophila was always present on cork slabs during the maturing period, but mould diversity appeared to be associated to the different factory configurations and processing steps. Conclusions: Spatial separation of the different steps of the process, including physical separation of the maturation step, is essential to guarantee high air quality and appropriate cork slabs colonization, i.e. C. sitophila dominance. The sorting and cutting of the edges of cork slabs after boiling and before the maturing step is also recommended. Significance and Impact of the Study: This study is very important for the cork stopper industry as it gives clear indications on how to keep high quality manufacturing standards and how to avoid occupational health problems.
Resumo:
RESUMO - O ozono é o principal componente da poluição fotoquímica do ar. Como agente irritante do aparelho respiratório, os seus efeitos sobre a saúde caracterizam-se, essencialmente, por tosse, dispneia, desconforto torácico e alterações da função pulmonar, encontrando-se também associadas à exposição ambiental a O3 tanto uma maior frequência e gravidade de crises de asma como a ocorrência de quadros clínicos de irritação conjuntival. É sobretudo a partir dos anos 50, com a descoberta de concentrações elevadas de ozono em ambientes de trabalho respeitantes à actividade de soldadura «a arco», que aquele gás passa a ser encarado como factor profissional de risco. No início dos anos 60 surgem os primeiros estudos de exposição a O3 em cabinas de avião, suscitados pela ocorrência, em tripulantes e passageiros, de queixas clínicas de irritação do tracto respiratório. Esta sintomatologia era, até então, atribuída à acção de outros factores, designadamente o sistema de ventilação e o baixo teor de humidade do ar. Posteriormente, alguns estudos revelaram que, em voos comerciais subsónicos, os teores elevados de O3 observados no interior das cabinas poderiam ser provocados pela sua insuficiente destruição nos sistemas de entrada de ar.O presente estudo, efectuado em voos de longo curso realizados em aeronaves Airbus A340-300 numa única rota comercial, teve por objectivo avaliar a exposição a ozono no ar interior em cabina de avião. Os teores médios de concentração de ozono observados foram inferiores aos valores susceptíveis de provocarem efeitos adversos sobre o aparelho respiratório. Como valor máximo instantâneo, foi atingida a concentração de 152 ppb. Adicionalmente, foi constatada a influência das estações do ano nos teores de O3. O conjunto dos resultados obtidos permite concluir que as concentrações de ozono no ar interior nas cabinas de avião estudadas são inferiores às correspondentes concentrações máximas admissíveis, tendo, em todos os voos, sido observado o cumprimento da norma da FAA respeitante à protecção da exposição ao ozono em cabinas de aeronaves de aviação comercial.